首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 953 毫秒
1.
The design, fabrication and field measurement of 11 DC curved dipole magnets for the PEFP Beam Line have been completed. In this paper, a design method for a complex end chamfer using OPERA-3D is proposed. The conventional method for estimating chamfer shape is extended and applied to a curved dipole magnet by a coordinate transformation. Using the interface with CAD software, the complex end chamfer is modeled and fully determined by 3D simulation to meet the field uniformity requirement. The magnetic field measurement results are in good agreement with the simulation. The design considerations, field simulation results, end chamfer development process and measurement results are presented in detail.  相似文献   

2.
Design and cold test of a rectangular cavity beam position monitor   总被引:1,自引:0,他引:1  
The CBPM is a kind of monitor which is used for the measurement of beam transverse position. It is becoming increasingly popular due to its high potential in resolution performance. In theory, the resolution can reach about 1 nanometer. In this paper, a rectangular CBPM is designed for it has better X-Y isolation than a cylindrical one. It has been simulated and measured, and the results agree with each other very well. The procedures and results for the simulation and the cold test will be shown later and it will be proved that this is a reliable method for the CBPM design.  相似文献   

3.
The Beijing X-ray Energy Recovery Linac (BXERL) test facility is proposed in Institute of High Physics (IHEP). In this proposal, the main linac requires the injector to provide an electron beam with 5 MeV energy and 10 mA average current. An injector based on DC gun technology is the first candidate electron source for BXERL. However, the field emission in the DC gun cavity makes it much more difficult to increase the high voltage to more than 500 kV. Another technology based on a 217 MHz normal conducting RF gun is proposed as the backup injector for this test facility. We have designed this RF gun with 2D SUPERFISH code and 3D MICROWAVE STUDIO code. In this paper, we present the optimized design of the gun cavity, the gun RF parameters and the set-up of the whole injector system. The detailed beam dynamics have been done and the simulation results show that the injector can generate electron bunches with RMS normalized emittance 1.0 uppi mmcdotmrad, bunch length 0.77 mm, beam energy 5.0 MeV and energy spread 0.60%.  相似文献   

4.
IHEP, China is constructing a 100 MeV/100 kW electron Linac for NSC KIPT, Ukraine. This linac will be used as the driver of a neutron source based on a subcritical assembly. In 2012, the injector part of the accelerator was pre-installed as a testing facility in the experimental hall #2 of IHEP. The injector beam and key hardware testing results met the design goal. Recently, the injector testing facility was disassembled and all of the components for the whole accelerator have been shipped to Ukraine from China by the ocean shipping. The installation of the whole machine in KIPT will be started in June, 2013. The construction progress, the design and testing results of the injector beam and key hardware are presented.  相似文献   

5.
IHEP, China is constructing a 100 MeV/100 kW electron Linac for NSC KIPT, Ukraine. This linac will be used as the driver of a neutron source based on a subcritical assembly. In 2012, the injector part of the accelerator was pre-installed as a testing facility in the experimental hall ≠2 of IHEP. The injector beam and key hardware testing results met the design goal. Recently, the injector testing facility was disassembled and all of the components for the whole accelerator have been shipped to Ukraine from China by the ocean shipping. The installation of the whole machine in KIPT will be started in June, 2013. The construction progress, the design and testing results of the injector beam and key hardware are presented.  相似文献   

6.
The China ADS(C-ADS) project proposes to build a 1000 MW Accelerator Driven sub-critical System around 2032. The accelerator will work in CW mode with 10 mA in beam current and 1.5 GeV in final beam energy. The linac is composed of two major sections: the injector section and the main linac section. There are two diferent schemes for the injector section. The Injector-scheme is based on a 325 MHz RFQ and superconducting spoke cavities of the same RF frequency and the Injector-scheme is based on a 162.5 MHz RFQ and superconducting HWR cavities of the same frequency. The main linac design will be diferent for diferent injector choices. The two diferent designs for the main linac have been studied according to the beam characteristics from the diferent injector schemes.  相似文献   

7.
A conception design of the Advanced Proton Therapy Facility (APTF) has been carried out. The system intentionally employs a slow-cycling synchrotron with a maximum energy of 250 MeV, two rotating gantries and two fixed beam nozzles for the treatment. In this paper, we try to compare the strength and weaknesses between the two treatment methods: the beam spreading and the pencil beam scanning. The application of the pencil beam scanning method and the double-scattering method together with the related nozzle design at APTF is also given. The simulation results of employing the double-scattering method have been given during the preliminary design.  相似文献   

8.
The China ADS (C-ADS) project proposes to build a 1000 MW Accelerator Driven sub-critical System around 2032. The accelerator will work in CW mode with 10 mA in beam current and 1.5 GeV in final beam energy. The linac is composed of two major sections: the injector section and the main linac section. There are two different schemes for the injector section. The Injector-Ⅰ scheme is based on a 325 MHz RFQ and superconducting spoke cavities of the same RF frequency and the Injector-Ⅱ scheme is based on a 162.5 MHz RFQ and superconducting HWR cavities of the same frequency. The main linac design will be different for different injector choices. The two different designs for the main linac have been studied according to the beam characteristics from the different injector schemes.  相似文献   

9.
Since the tapered quarter wave resonator (QWR) cavity is proven to have a much lower peak surface magnetic field in the short plate and a lower peak surface electric field near the beam tube compared with the straight outer conductor QWR, it has been recommended for the separated sector cyclotron linac injector system in the heavy ion research facility in Lanzhou. This paper is focused on the multipacting (MP) analysis for the tapered QWR with a frequency of 80.5 MHz and beta of 0.085. Using the Analyst program, MP bands can be simulated and analyzed with the Particle Tracking module to identify potential problems in the cavity design. This paper will present the simulation results of MP for the tapered QWR cavity.  相似文献   

10.
王蕊  孙辉  王杰智  王鲁  王晏超 《中国物理 B》2015,24(2):20501-020501
Modularized circuit designs for chaotic systems are introduced in this paper.Especially,a typical improved modularized design strategy is proposed and applied to a new hyper-chaotic system circuit implementation.In this paper,the detailed design procedures are described.Multisim simulations and physical experiments are conducted,and the simulation results are compared with Matlab simulation results for different system parameter pairs.These results are consistent with each other and they verify the existence of the hyper-chaotic attractor for this new hyper-chaotic system.  相似文献   

11.
A new procedure for the design and simulation of a Radio Frequency Quadrupole (RFQ) accelerator has been developed at the Argonne National Laboratory. This procedure is integrated with the beam dynamics design code DESRFQ and the simulation code TRACK, which are based on three-dimensional field calculations and the particle-in-cell mode beam dynamics simulations. This procedure has been applied to the development of a 162.5 MHz CW RFQ which is capable of delivering a 10 mA proton beam for the Accelerator Driven System (ADS) of the CAS. The simulation results show that this RFQ structure is characterized by the stable values of the beam acceleration efficiency for both the zero current beam and space charge dominated beam. For an average beam current of 10 mA, there is no transverse rms emittance growth, the longitudinal rms emittance at the exit of RFQ is low enough and there is no halo formation. The beam accelerated in the RFQ could be accepted easily and smoothly by the following super-conducting linear accelerator.  相似文献   

12.
The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles at astrophysical energies. The Trojan-horse method (THM) has been introduced to solve the difficulties as a powerful indirect tool. In order to understand experimental spectra better, Geant4 is employed to simulate the method. Validity and reliability of simulation data are examined by comparing the experimental data with simulated results. The Geant4 simulation of THM improves data analysis and is beneficial to the design for future related experiments.  相似文献   

13.
A new compact accelerating structure named Hybrid RFQ is proposed to accelerate a high-intensity low-energy heavy ion beam in HISCL (High Intensive heavy ion SuperConducting Linear accelerator), which is an injector of HIAF (Heavy Ion Advanced Research Facility). It is combined by an alternative series of acceleration gaps and RFQ sections. The proposed structure has a high accelerating ability compared with a conventional RFQ and is more compact than traditional DTLs. A Hybrid RFQ is designed to accelerate 238U34+ from 0.38 MeV/u to 1.33 MeV/u. The operation frequency is described to be 81.25 MHz at CW (continuous wave) mode. The design beam current is 1.0 mA. The results of beam dynamics and RF simulation of the Hybrid RFQ show that the structure has a good performance at the energy range for ion acceleration. The emittance growth is less than 5% in both directions and the RF power is less than 150 kW. In this paper, the results of beam dynamics and RF simulation of the Hybrid RFQ are presented.  相似文献   

14.
As for a flexible horizontal array deployed in the sea, it is difficult to obtain each sensor's precise relative position. Therefore a method of array shape calibration is proposed. The method is described as follows. Firstly two separate auxiliary sources are deployed. Secondly tune delay of each sensor's received signal is estimated. Finally, with the aid of GPS location of the sources and the horizontal array, relative sensor positions of the horizontal array can be determined. The estimation of relative sensor positions is unbiased. Simultaneously, simulation analysis has been done to estimate its standard variance, and the optimal flare angle of the two sources has been derived. Data of 2001 Asian Sea International Experiment have been used to validate the method. After array calibration, measured source azimuth angle agrees with the real one, and measured array gain agrees with the theoretical gain. In conclusion, the theoretical and experimental results both show that the method can determine each sensor's relative position precisely.  相似文献   

15.
This paper presents the first phase of design, analysis, and simulation for the klystron coaxial radio frequency(RF)output window. This study is motivated by 800 kW continuous wave(CW), 650 MHz klystrons for the future plan of circular electron–positron collider(CEPC) project. The RF window which is used in the klystron output section has a function to separate the klystron from the inner vacuum side to the outside, and high RF power propagates through the window with small power dissipation. Therefore, the window is a key component for the high power klystron. However, it is vulnerable to the high thermal stress and multipacting, so this paper presents the window design and analysis for these problems. The microwave design has been performed by using the computer simulation technology(CST) microwave studio and the return loss of the window has been established to be less than-90 d B. The multipacting simulation of the window has been carried out using MultiPac and CST particles studio. Through the multipacting analysis, it is shown that with thin coating of TiN, the multipacting effect has been suppressed effectively on the ceramic surface. The thermal analysis is carried out using ANSYS code and the temperature of alumina ceramic is lower than 310 K with water cooling.The design result successfully meets the requirement of the CEPC 650 MHz klystron. The manufacturing and high power test plan are also described in this paper.  相似文献   

16.
A TTF-type coaxial higher order modes (HOM) coupler has been used in a TESLA 9 cell cavity. It is impossible to measure the stop band characteristics of the HOM coupler with the cavity. A measurement device for the coaxial transmission line type for the HOM coupler has been designed at Peking University. Experimentally it was shown that the average voltage standing wave ratio of the coaxial transmission line is smaller than 1.08. The experimental results of the stop band characteristics of the TTF-type HOM coupler have been fitted for the simulation. This paper describes the design of the measurement device and discusses the experimental and simulation results of stop band characteristics of the HOM coupler.  相似文献   

17.
To perform a kinematically complete measurement of the dissociation reaction for neutron-rich nuclei, a multi-neutron correlation spectrometer is proposed at Peking University. A Monte Carlo simulation code based on GEANT4 is developed for a single scintillation bar which processes not only the energy deposition but also the light propagation in the scintillator and the light collection and conversion to signal at the end of the bar in a realistic way. The simulating method is described in detail in this paper, and the timing and position resolutions and detector efficiency are studied based on the simulation and compared with the experimental results. A new method of crosstalk rejection has been demonstrated to be important for the design of the whole spectrometer.  相似文献   

18.
The SSC-linac (a new injector for the Separated Sector Cyclotron) is being designed in the HIRFL (Heavy Ion Research Facility in Lanzhou) system to accelerate 238U34+ from 3.72 keV/u to 1.008 MeV/u. As a part of the SSC-linac injector, the HEBT (high energy beam transport) has been designed by using the TRACE-3D code and simulated by the 3D PIC (particle-in-cell) Track code. The total length of the HEBT is about 12 meters and a beam line of about 6 meters are shared with the exiting beam line of the HIRFL system. The simulation results show that the particles can be delivered efficiently in the HEBT and the particles at the exit of the HEBT well match the acceptance of the SSC for further acceleration. The dispersion is eliminated absolutely in the HEBT. The space-charge effect calculated by the Track code is inconspicuous. According to the simulation, more than 60 percent of the particles from the ion source can be transported into the acceptance of the SSC.  相似文献   

19.
The Intensity Heavy Ion Superconducting Linear Accelerator as the injector of the High Intensity Heavy-Ion Accelerator Facility, which is a new project proposed in China has been designed. One of the design options in the low energy part is based on Quarter Wave Resonators (QWRs). However, because of the unsymmetrical geometry of the cavity, there are dipole fields near the beam hole, which may steer the beam vertically, thus leading to emittance growth and beam loss. The effect of the dipole mode field is analyzed, and a method to overcome the beam steering effect by placing QWRs with opposite orientation is proposed in this paper. The simulation results show that the beam steering effect is reduced effectively by this method, and the deviation of the beam centroid is decreased from 2.87 mm to 0.1 mm. The emittance growth is also smaller.  相似文献   

20.
A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.  相似文献   