排序方式: 共有39条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
比较了行波与驻波两种工作方式以及前向波与返波型行波的不同特点;研究了返波型行波电子直线加速结构的工作特性;并针对返波型行波电子直线加速结构的特点,进行工作模式的选择;对工作频率为2856MHz,3π/4模的返波加速结构进行了优化设计;研究了带聚束段的返波型行波加速管的纵向与横向粒子动力学问题;为海关大型集装箱在线检测用加速器设计了一根9MeV返波型行波加速管,并与采用盘荷波导结构的加速管进行了对比.研究结果表明,返波型行波电子直线加速结构具有一定的优势,它把鼻锥型加速结构分流阻抗高及盘荷波导行波工作方式填充时间短,工作稳定性好等优点结合起来,性能明显优越. 相似文献
5.
RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment. Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with further acceleration to 50 MeV, which is under development, are presented. A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned. 相似文献
6.
The tuning method of uniform traveling-wave structures based on the non-resonant perturbation field distribution measurement has been widely used in tuning both constant-impedance and constant-gradient structures. In this paper, the method of tuning nonuniform structures is proposed on the basis of the above theory. The internal reflection coefficient of each cell is obtained from analyzing the normalized voltage distribution. A numerical simulation of tuning process according to the coupled cavity chain theory has been done and the result shows each cell is in right phase advance after tuning. The method will be used in the tuning of a disk-loaded traveling-wave structure which is being developed at the Accelerator Laboratory, Tsinghua University. 相似文献
7.
The CBPM is a kind of monitor which is used for the measurement of beam transverse position. It is becoming increasingly popular due to its high potential in resolution performance. In theory, the resolution can reach about 1 nanometer. In this paper, a rectangular CBPM is designed for it has better X-Y isolation than a cylindrical one. It has been simulated and measured, and the results agree with each other very well. The procedures and results for the simulation and the cold test will be shown later and it will be proved that this is a reliable method for the CBPM design. 相似文献
8.
The external Q (Qext) of the dipole mode is a key parameter of the Cavity Beam Position Monitor (CBPM). It determines the amplitude and length of the dipole mode signal. In this paper, Qext of a CBPM whose waveguides were open to the air was simulated and measured, and the results agreed with each other. Then four waveguide-to-coaxial cable adpaters were adjusted and assembled to the CBPM, and Qext remained unchanged. This progress provides a reliable method to evaluate Qext in the physics design without si... 相似文献
9.
10.
The waveguide to coaxial cable adapter is very important to the cavity beam position monitor (CBPM) because it determines how much of the energy in the cavity could be coupled outside. In this paper, the waveguide to coaxial cable adapter of a CBPM is designed and experiments are conducted. The curve shapes of experiments and simulations are very similar and the difference in reflection is less than 0.1. This progress provides a reliable method for designing the adapter. 相似文献