首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
许旭  肖远灿  耿丹丹  皮立  董琦  胡风祖 《色谱》2016,34(4):422-428
在考察了荧光胺、邻苯二甲醛、异硫氰酸荧光素和2,3-萘二醛等对磺胺类药物衍生效果的基础上,建立了采用改良QuEChERS方法进行样品前处理,荧光胺在线柱后衍生,高效液相色谱-荧光检测法测定牛肉中16种磺胺残留量的方法。牛肉样品经1%(v/v)乙酸乙腈溶液提取,改良QuEChERS方法净化后取上清液进样,与荧光胺柱后在线衍生,荧光检测器检测。实验结果表明,16种磺胺类药物在0.024~2.533 mg/L范围内线性关系良好,相关系数(r)大于0.992,检出限为1.6~8.2 μg/kg,平均加标回收率范围为66.6%~109.5%,相对标准偏差为0.9%~9.9%。该方法快速简便、灵敏度高、净化效果好,可用于牛肉中16种磺胺类药物的快速测定。  相似文献   

2.
建立了一种高效、低成本的固相萃取-高效液相色谱(SPE-HPLC)同时测定鸡粪中6种常见抗生素(2种四环素类、2种喹诺酮类和2种磺胺类)的分析方法。样品经EDTA-McIlvaine缓冲液和有机混合提取液(甲醇-乙腈-丙酮,2:2:1,v/v/v)提取,过HLB固相萃取柱净化,甲醇-二氯甲烷(7:3,v/v)洗脱,高效液相色谱-二极管阵列检测器测定,检测波长λ=270 nm,柱温32℃,流动相为乙腈-0.7%(v/v)磷酸水溶液。该方法在0.5~100 mg/L质量浓度范围内的标准曲线相关系数r2在0.9999~1之间,样品加标回收率在70.0%~116.3%之间,相对标准偏差为1.2%~16.6%。方法检出限为1.3~6.7 μg/kg,定量限为3.5~9.2 μg/kg。应用该方法对辽宁省抚顺市某养鸡场当天的鸡粪进行检测,诺氟沙星和恩诺沙星(喹诺酮类)含量为未检出~9.23 mg/kg和1.57~7.69 mg/kg,磺胺二甲嘧啶(磺胺类)含量为2.02~13.05 mg/kg,磺胺甲恶唑、土霉素和四环素未测出。  相似文献   

3.
刘菁华  孙振中  黄雪玲  郭霞  孙建华 《色谱》2015,33(4):434-440
建立了养殖水体及沉积物中11种磺胺化合物的高效液相色谱-柱后衍生分析方法。养殖水体过滤后采用HLB固相萃取柱进行净化、富集;沉积物采用甲醇/EDTA-Mcllvaine缓冲液(1:1, v/v)提取,HLB固相萃取柱净化富集。经高效液相色谱分离,用荧光胺衍生试剂进行柱后衍生,荧光检测器检测。对柱后衍生系统参数进行了优化,确定了荧光胺溶液的浓度、流速和反应温度分别为0.2 g/L、0.15 mL/min和50 ℃,磺胺化合物在0.01~1.0 mg/L范围内线性显著,其相关系数r2值大于0.99995。11种磺胺类药物在养殖水体和沉积物中的加标回收率分别为79.3%~100.7%和74.6%~95.3%,相对标准偏差为2.2%~11.0%和2.6%~10.3%,检出限(LOD, S/N=3)为0.9~5.5 ng/L和0.3~1.3 μg/kg,定量限(LOQ, S/N=10)为3.0~18.1 ng/L和1.0~4.4 μg/kg。该法可应用于养殖环境中磺胺类药物的定性定量检测,具有较好的实用性。  相似文献   

4.
王韦岗  强敏  端礼钦 《色谱》2018,36(12):1330-1336
建立了复合免疫亲和柱-在线光化学衍生-高效液相色谱同时测定谷物及其制品中9种真菌毒素的检测方法。以乙腈-水(80:20,v/v)混合溶液提取样品中9种真菌毒素,提取液经自制真菌毒素复合免疫亲和柱净化,采用高效液相色谱进行分离,在线光化学衍生后进入荧光检测器测定,外标法定量。结果表明,9种真菌毒素在相应浓度范围内线性关系良好,相关系数均大于0.999;在低、中、高3个不同加标浓度下,9种真菌毒素的回收率均大于80%,相对标准偏差(RSD)为1.0%~5.6%;方法的检出限(LOD)为0.02~5.00 μg/kg,定量限(LOQ)为0.07~16.70 μg/kg。该方法具有重现性好、灵敏度高、结果准确的特点,适用于谷物及其制品中9种真菌毒素残留的分析检测。  相似文献   

5.
动物源性食品中五种氟喹诺酮类药物残留量的同时测定   总被引:4,自引:1,他引:3  
建立了一种测定动物源性食品中5种氟喹诺酮类药物残留量的高效液相色谱法。样品经酸性乙腈提取,正己烷液-液分配净化,0.01 mol/L四丁基溴化铵溶液溶解残渣,过微孔滤膜,采用高效液相色谱附荧光检测器检测,外标法定量。氧氟沙星、环丙沙星、恩诺沙星线性范围为0.002~0.200μg/mL;诺氟沙星、达氟杀星线性范围为0.001~0.100μg/mL,5种氟喹诺酮类药物的相关系数为0.99901~0.99917。在0.002~0.040 mg/kg范围内,样品加标平均回收率在79.6%~97.5%之间,相对标准偏差为2.8%~15.3%。方法的检出限氧氟沙星、环丙沙星、恩诺沙星为0.004 mg/kg,诺氟沙星、达氟沙星为0.002 mg/kg。  相似文献   

6.
采用柱前衍生-超高效液相色谱-串联质谱测定茶叶中草甘膦、草铵膦及其主要代谢物氨甲基膦酸残留。利用正交试验方法,系统研究了提取与净化等前处理条件对茶叶中草甘膦、草铵膦和代谢物氨甲基膦酸检测的影响。实验结果表明,最优的前处理方案为茶叶样品经纯水旋涡提取,阳离子交换柱净化,0.5%(v/v)甲酸水溶液洗脱和9-芴甲基氯甲酸酯衍生,C18色谱柱分离,超高效液相色谱-串联质谱定量分析(电喷雾正离子)。结果表明:在1~100 μ g/L范围内,草甘膦、草铵膦和氨甲基膦酸呈现良好的线性关系,相关系数(R2)均大于0.991,该方法检出限为0.0160~0.0300 mg/kg,定量限为0.0530~0.100 mg/kg。在0.0500、0.400和1.20 mg/kg 3个添加水平下,草甘膦、草铵膦和氨甲基膦酸的平均回收率为78.3%~108%,相对标准偏差为5.46%~9.63%。利用该方法检测837份茶叶中草甘膦、草铵膦和氨甲基磷酸残留,检出率分别为3.46%、0.24%和4.42%,超标率为0.24%。该方法简单、快速、灵敏、准确,能够满足大批量茶叶中草甘膦、草铵膦和氨甲基膦酸残留的检测需要。  相似文献   

7.
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)测定猪肉组织中4种硝基呋喃类代谢物的分析方法.样品经盐酸水解,2-硝基苯甲醛衍生,乙酸乙酯提取净化,在正离子模式下以电喷雾电离串联质谱进行测定,内标法定量.在优化的实验条件下,4种代谢物在0.5~50μg/kg范围内线性良好,相关系数大于0.995,方法检出限为0.2μg/kg,定量限为0.5μg/kg.在0.5、1.0和10.0μg/kg的添加水平下,4种代谢物的平均回收率在74.6%~104.8%之间,相对标准偏差(RSD,n=6)在2.4%~15.6%之间.方法可应用于猪肉中4种硝基呋喃类药物代谢物残留的同时检测.  相似文献   

8.
利用过氧化苯甲酰能够在氯化血红素的催化下将底物对羟基苯乙酸氧化成具有荧光的二聚体的性质,建立了柱后衍生-高效液相色谱-荧光检测法测定面粉中过氧化苯甲酰的方法。优化了色谱分离条件和柱后衍生条件,结果表明:催化剂氯化血红素的浓度为8μmol/L,底物对羟基苯乙酸的浓度为80μmol/L,衍生化试剂的pH 10.5,衍生温度为35℃时衍生效率最高。在优化条件下,过氧化苯甲酰的线性范围为0.5~100 mg/L;样品的检出限为1 mg/kg,样品的加标回收率为98.5%~99.5%。本方法与现有的高效液相色谱法相比,检测面粉中过氧化苯甲酰具有抗干扰能力强,灵敏度高。  相似文献   

9.
建立了低温分配固液萃取(SLE-LTP)技术结合高效液相色谱-质谱(HPLC-MS)测定食用菌中6-苄基腺嘌呤(6-BA)的方法。食用菌样品经乙腈提取和低温分配,采用Hitachi LaChrom C18色谱柱(250 mm×4.6 mm,5 μm)分离,以0.02 mol/L乙酸铵(含0.1%(v/v)冰乙酸)-甲醇(6∶4,v/v)溶液为流动相,等度洗脱,在电喷雾正离子模式下检测,外标法定量。结果表明,6-苄基腺嘌呤在0.05~2.0 mg/L范围内线性关系良好,相关系数为1.0000;方法的检出限和定量限分别为0.006 mg/kg和0.02 mg/kg。加标回收率试验显示在0.1 mg/kg和0.5 mg/kg添加水平下6-苄基腺嘌呤的加标回收率为81.3%~93.7%,相对标准偏差为0.7%~2.4%。该法简单、准确、稳定,可用于食用菌中6-苄基腺嘌呤的检测。  相似文献   

10.
徐敦明  陈燕  周爽  连英杰  陈鹭平  林立毅  周昱  黄志强 《色谱》2013,31(12):1224-1227
建立了测定淀粉及其制品中顺丁烯二酸和顺丁烯二酸酐总含量的高效液相色谱-串联质谱(HPLC-MS/MS)方法。样品经50%(v/v)甲醇提取、碱性条件下水解后,采用液相色谱-串联质谱对其进行分析,外标法定量。质谱分析采用电喷雾电离,负离子扫描,多反应监测模式。实验表明样品无明显的基质效应,添加水平为0.5~1000 mg/kg时,回收率为80.2%~115.3%,相对标准偏差(n=6)小于12%;方法检出限(LOD)为0.1 mg/kg,定量限(LOQ)为0.5 mg/kg。该方法提取效果好,具有良好的灵敏度、回收率和重复性,已被成功用于实际样品中顺丁烯二酸和顺丁烯二酸酐总含量的测定。  相似文献   

11.
Wang T  Chen Y  Hu M  Li X 《色谱》2012,30(2):215-218
建立了一种基于纯水提取的新型烟熏鲣鱼中肌苷酸的提取方法。样品前处理采用95 ℃的纯水作为提取液,提取5 min。采用的色谱条件: 色谱柱为Agilent Zorbax SB-C18柱(150 mm×4.6 mm, 5 μm),柱温为30 ℃,流动相为甲醇-50 mmol/L乙酸铵水溶液(5:95, v/v),流速为1.0 mL/min,检测波长为254 nm。结果表明,该方法测定烟熏鲣鱼中肌苷酸含量的线性范围为1.0~120.0 mg/L;在0.40、2.00、4.00 g/kg (n=3)的添加水平下,回收率为84.6%~100.2%,测定结果的相对标准偏差(RSD)为1.00%~6.12%;检出限(信噪比(S/N)为3)为4 mg/kg;定量限(S/N=10)为12 mg/kg。该方法与常规采用的基于高氯酸的提取方法相比较,提取效率提高了37.0%,并且该方法操作安全、与环境友好,对烟熏鲣鱼中肌苷酸含量测定准确度良好,对其他食品中肌苷酸含量的测定具有借鉴意义,是一种值得推广的样品预处理方法。  相似文献   

12.
An improved sensitive method was developed and validated for the determination of histamine in food samples by using automated on-line pre-column derivatization coupled with high performance liquid chromatography and fluorescence detection (HPLC-FLD). o-Phthaldialdehyde (OPA) was adopted as derivatization reagent, and a "sandwich" (OPA+histamine+OPA) aspiration mode for the automated on-line pre-column derivatization was found to efficiently enhance the method sensitivity and precision. Histamine in food samples was efficiently extracted with a methanol-phosphate buffer solution (50:50, v/v) at 60 degrees C for 30 min, and purified with Waters Oasis MCX solid-phase extraction (SPE) cartridge. The limit of quantification for this method is 0.2 mg/kg, which is very sensitive for histamine determination. With the "sandwich" injection program, 3.7% of relative standard deviation (RSD) was achieved by five replicative determinations of a sample blank spiked with 0.25 mg/kg histamine standard. Histamine in food samples such as fumitory skipjack and mackerel was analyzed with relative recoveries over 95% at spiking level of 150 mg/kg, as well as canned tuna fish and cheese with relative recoveries up to 98% at spiking levels of 0.50 and 5.0 mg/kg, respectively. The proposed method was validated with a sample from the Food Analysis Performance Assessment Scheme (FAPAS) as a standard certified material; and the results (140+/-6 mg/kg) agreed well with the assigned value (139 mg/kg).  相似文献   

13.
气相色谱-质谱法检测食品中残留的丙炔氟草胺   总被引:2,自引:0,他引:2  
林黎  叶刚  谢丽琪  蓝芳  吴卫东  靳保辉 《色谱》2008,26(3):318-321
建立了多种食品中丙炔氟草胺残留量的气相色谱-质谱检测方法。样品采用乙腈或乙酸乙酯提取,经旋转蒸发去除提取液后,用乙腈-甲苯(体积比为3∶1)溶解残渣,经氨基固相萃取柱净化,净化液由气相色谱-选择离子监测质谱测定,外标法定量。方法的线性范围为0.02~1.0 mg/L,多种食品基质中的平均回收率为79.4%~101%,相对标准偏差(RSD)为0.242%~7.15%(n=10),检测限均为0.01 mg/kg。该方法灵敏度高,选择性好,可作为多种食品中丙炔氟草胺残留量的常规检测方法。  相似文献   

14.
建立了液相色谱-串联质谱(LC-MS/MS)测定食品中二甲基黄(DMY)的分析方法。样品经乙酸乙酯提取,二甲基黄专用固相萃取小柱(ProElut DMY SPE)净化,XDB-C18色谱柱(50 mm×4.6 mm,1.8μm)分离,并以5mmol/L乙酸铵水溶液(含0.1%(v/v)甲酸)-乙腈(含0.1%(v/v)甲酸)为流动相,梯度洗脱,电喷雾正离子模式(ESI~+)电离,多反应监测模式(MRM)检测,内标法定量。结果表明,DMY在0~50μg/L范围内线性关系良好,相关系数(r~2)均大于0.999。方法的检出限(LOD,S/N3)和定量限(LOQ,S/N10)分别为2μg/kg和10μg/kg。不同食品基质中,DMY在10、20和100μg/kg的添加水平下的平均加标回收率为93.3%~98.9%,相对标准偏差为1.6%~3.9%(n=6)。该方法有效补偿了液相色谱-串联质谱检测过程中的离子化抑制效应,灵敏度和准确度高,适用于腐乳、辣椒酱、禽蛋、豆干、糖果和火腿中DMY的测定。  相似文献   

15.
陈达炜  苗虹  赵云峰  吴永宁 《色谱》2013,31(12):1206-1210
分析酒精度对高效液相色谱-荧光(HPLC-FLD)法测定白酒中氨基甲酸乙酯(EC)含量的影响,建立了快速检测白酒中EC含量的HPLC-FLD分析方法。通过比较不同酒精度下同一EC含量的峰面积,研究酒精度对EC含量测定的影响。结果表明,在5%~65%(v/v)酒精度范围内,酒精度与EC含量(峰面积)具有良好的线性关系,相关系数R2大于0.98,同时建立了不同酒精度间EC含量换算的相对校正系数。该方法在10~500 μg/L范围内呈良好的线性关系,R2大于0.9999,定量限为10 μg/L,加标回收率为98.9%~108.2%,相对标准偏差为0.6%~4.9%。评价了HPLC-FLD法的可靠性,将该方法与GC-MS方法比较,结果显示两种方法无明显差异。该方法简单、灵敏、准确,适用于白酒中EC含量的快速测定,具有较好的实际应用价值。  相似文献   

16.
高效液相色谱法测定食品中氟啶脲的残留量   总被引:1,自引:0,他引:1  
Du L  Song J  Zhang L  Liu H 《色谱》2011,29(12):1240-1243
建立了高效液相色谱测定食品中氟啶脲残留量的方法.样品中的氟啶脲经正己烷或乙腈提取,弗罗里硅土净化后,以乙腈-水( 85:15,v/v)混合溶液为流动相,经C18色谱柱分离,紫外检测器(260 nm)测定.结果表明:氟啶脲在0 05 ~2.0 mg/L范围内线性良好(相关系数为0 999 8),定量限(以信噪比为10计)...  相似文献   

17.
肖泳  吴海智  袁列江  唐吉旺  王淑霞  王秀  邓航  吴林 《色谱》2020,38(2):218-223
建立了高效液相色谱-串联质谱测定动物源性食品中矮壮素残留的分析方法。样品经含1%(v/v)乙酸的乙腈溶液提取、正己烷脱脂、阳离子固相萃取柱(PCX)净化,采用Venusil MP C18(2)色谱柱(150 mm×2.1 mm,3 μm)分离,以乙腈和0.1%(v/v)甲酸水溶液为流动相进行梯度洗脱,采用电喷雾电离、正离子模式扫描,多反应监测模式(MRM)检测,基质匹配标准曲线内标法定量。结果表明:矮壮素在0.200~500 μg/L范围内呈良好线性,相关系数(r2)均不低于0.9993,方法的定量限为0.500 μg/kg;以猪肉、牛肉、羊肉、鸡肉、鸡蛋、猪肾、牛肝、羊肾、鸡肝、牛奶为基质,矮壮素的平均加标回收率为93.4%~101%,相对标准偏差为2.3%~8.0%。该方法基质干扰小,灵敏度高,准确可靠,适用于动物源性食品中矮壮素残留的定量检测。  相似文献   

18.
刘茜  刘晓宇  邱朝坤  王小宝  任红敏 《色谱》2009,27(4):476-479
建立了鲫鱼肌肉中残留的辛硫磷的基质固相分散-高效液相色谱-二极管阵列检测(MSPD-HPLC-DAD)的分析方法。通过优化样品处理条件,确定选取0.50 g鲫鱼肌肉样品与1.5 g弗罗里硅土、0.5 g无水硫酸钠混合研磨,并采用丙酮-正己烷溶液(体积比为40:60)为洗脱剂,洗脱剂用量为25 mL。优选的最佳色谱条件为:ODS色谱柱(250 mm×4.6 mm,5 μm),流动相为甲醇-水(体积比为50:50),流速0.6 mL/min,检测波长270 nm,进样量为20 μL。在上述条件下,辛硫磷质量浓度在0.01~10 mg/L范围内与响应信号呈良好的线性关系(r20.9994),检出限为3.3 μg/kg;相对标准偏差为1.1%~6.3%(n7);3个添加水平(0.05,0.1,1 mg/kg)下得到的回收率为88%~112%。该方法操作简单,耗时少,精密度高,符合农残分析的要求。  相似文献   

19.
郑熠斌  黄百芬  任一平 《色谱》2016,34(7):692-696
建立了正相高效液相色谱测定食物中8种维生素E异构体及维生素A的方法。样品中的维生素E异构体和维生素A经皂化和液液萃取,Waters ACQUITYTM UPLC BEH Amide色谱柱(150 mm×3.0 mm, 1.7 μm)分离,体积比为90 : 10的正己烷与叔丁基甲基醚-四氢呋喃-甲醇(20:10:1, v/v/v)为流动相,荧光检测器和紫外检测器串联检测。4种生育酚在5.0~60.0 mg/L(r2≥0.9999)、维生素A和4种三烯生育酚在0.5~6.0 mg/L(r2≥0.9996)范围内具有良好的线性,各基质中目标物的检出限在20~60 μg/kg之间;9个组分在各基质中的加标回收率为79.2%~114.2%,相对标准偏差(RSD)为1%~12%。该方法简便、灵敏、可靠、环保,可用于食物中8种维生素E异构体以及维生素A含量的同时测定。  相似文献   

20.
林涛  邵金良  刘兴勇  王静  邹艳虹  李茂萱  刘宏程 《色谱》2018,36(12):1223-1227
采用改进的QuEChERS方法,结合超高效液相色谱-串联质谱法(UPLC-MS/MS),建立了热带水果中杀虫双残留的测定方法。热带水果经含1%(v/v)乙酸的乙腈溶液二次提取,200 mg N-丙基乙二胺(PSA)、100 mg C18、300 mg MgSO4和500 mg柠檬酸氢二钠净化。采用CAPCELL CORE PC亲水色谱柱进行分离,在负离子多反应监测(MRM)模式下检测,外标法定量。结果表明,杀虫双在0.1~10.0 μg/L范围内线性关系良好,相关系数(r2)为0.9993,检出限和定量限分别为0.015 μg/kg和0.05 μg/kg,加标回收率为81.0%~88.3%,相对标准偏差(RSD)为3.9%~6.2%。该法净化效果好,灵敏度高,适于热带水果中杀虫双残留的快速定性和定量分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号