首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
土壤中多种有机氯及拟除虫菊酯类农药的GC-ECD测定   总被引:1,自引:0,他引:1  
气相色谱法同时测定土壤中多种有机氯及拟除虫菊酯类农药。对土壤的分析结果:有机氯农药的检出限0.001~0、003μg/mL,拟除虫菊酯类农药检出限0.008~0.02μg/mL,线性相关系数0.9978~0.9999。用y(石油醚):V(丙酮)=3:1超声波提取,有机氯农药回收率94.2%~124.0%,相对标准偏差为3.3%~8.8%(n=5);拟除虫菊酯类农药回收率95.2%~118.3%,相对标准偏差为5.7%~7.1%(n=5);方法适用于土壤样品中农药残留测定。  相似文献   

2.
建立了同时测定牡蛎中16种有机氯农药残留量的前处理方法和气相色谱分析方法。在100℃的温度条件下,用加速溶剂提取(ASE)提取样品中的有机氯农药,用凝胶渗透色谱(GPC)结合Florisil柱净化,以RTX-5MS毛细管色谱柱分离、ECD检测器测定。结果表明,样品的加标回收率(n=3)为81%~110%,方法检出限为0.2~0.7ng/g,样品检测的相对标准偏差为2.9%~15.2%。  相似文献   

3.
建立了GC—MS/SIM与大体积进样技术结合测定蔬菜、水果中包括有机磷类、氨基甲酸酯类、有机氯类、菊酯类在内的17种农药的方法。样品经丙酮提取,OASIS HLB固相萃取小柱净化后,采用GC—Ms的选择离子模式和大体积进样技术进行测定,能够使相对检出限降低1~2个数量级。大多数农药的线性范围为0.05~10mg/kg,相关系数为0.9943—0.9996,相对标准偏差为3.5%-10.3%,回收率范围在77%~107%之间.方法能满足果蔬中17种农残限量的的检测要求,具有灵敏、快速、重复性好的特点。  相似文献   

4.
建立了用弗罗里硅土作基质固相分散剂的加速溶剂萃取、并以灭蚁灵(Mirex)为内标的快速、同时测定土壤中16种有机氯农药的气相色谱法。加速溶剂萃取仪在100℃,10.3Mpa用正己烷和丙酮(1:1,V/V)静态提取样品10min,0.01μg/g加标水平回收率为77.3%-101.3%;方法检出限为0.01—0.04ng/g。方法满足了土壤中有机氯农药残留测定的要求。对我国南方不同地域的72个土壤样品进行了测定,大部分有机氯农药在土壤中都有一定检出量,其中环氧七氯最高(2.6~844.5ng/g),甲氧DDT(23.2—219.8ng/g)和P,P’-DDT(4.0—183.1ng/g)次之,而o,P'-DDT在72个土样中都没有检出。  相似文献   

5.
研究利用炭石灰作为反相固定相,萃取水中12种有机氯农药,并用GC/ECD检测。实验表明,炭石灰萃取水中有机氯的效果与商品柱的萃取效果相当,对于200mL添加40ng有机氯农药混合标准溶液水样,其目标化合物的回收率为70%~122%,检出限为0.023~0.124μg/L,多次重复实验测定的相对标准偏差为3.40%~12.9%(n=5)。  相似文献   

6.
中草药中有机氯农药和拟除虫菊酯农药残留量的测定   总被引:31,自引:7,他引:24  
建立了中草药中11种有机氯农药和8种拟除虫菊酯农药的残留气相色谱分析方法。样品用含30%丙酮的乙腈提取,用正己烷进行液液分配,提取液用弗罗里硅土柱净化,采用兰州化物所的农残Ⅱ号毛细管柱分离,用GC-ECD同时检测。在两个水平添加时的回收率(n=5)分别为78.6%~119.7%和86.5%~114.0%,相对标准偏差分别为3.6%~8.7%和4.4%~10.2%。该方法的检出限为:有机氯农药0.005mg/kg,拟除虫菊酯农药0.01mg/kg。方法用于江西中草药样品中农药残留测定,结果满意。  相似文献   

7.
中药材中5种拟除虫菊酯农药残留量的测定   总被引:9,自引:0,他引:9  
王旗  杨彬  刘庆  李晓婷 《分析试验室》2006,25(12):99-102
研究中药材中5种拟除虫菊酯农药残留量的测定方法。用石油醚-丙酮混合溶剂超声提取,固相萃取法净化,用气相色谱-电子捕获检测器(ECD)测定。5种拟除虫菊酯农药在3种代表性中药材的加标回收率为72.6%-135.0%,相对标准偏差为3.6%。27%;方法的检出限为0.001—0.005μg/g。方法灵敏度高,选择性好,操作较为简便,适用于植物性(根、茎类)药材中5种拟除虫菊酯农药残留量的测定。  相似文献   

8.
建立了毛细管气相色谱法同时测定水产品中多氯联苯和有机氯农药的方法,用高氯酸与冰乙酸的混合溶液消化样品,以石油醚提取,浓硫酸净化后,用毛细管气相色谱法测定,方法的回收法为88%-110%,相对标准偏差为8%-19%(n=6),检出限为0.08-0.60ug/kg,方法简便,快速,结果准确。  相似文献   

9.
采用硅藻土柱层析法对样品中的农药进行提取及净化后,用气相色谱—质谱法在选择离子监测模式下进行快速测定,以保留时间和特征离子定性定量;采用此方法测定了包括有机氯农药、有机磷农药、氨基甲酸酯农药、拟除虫菊酯农药、三嗪类农药在内的105种农药,大多数农药的线性范围为0.05~10mg/kg,相关系数大于0.99;90%以上农药在0.2mg/kg添加水平的平均回收率在70%~110%的范围内。  相似文献   

10.
在超声波辅助下,以正己烷-二氯甲烷(1:1,V/V)混合溶剂提取样品,提取液用弗罗里硅土和中性氧化铝混合柱净化,用气相色谱-电子捕获检测器(GC-ECD)同时测定茶叶中18种有机氯和9种拟除虫菊酯类农药残留。有机氯农药在0.001-0.2μg/mL,拟除虫菊酯类农药在0.005-1.0μg/mL范围内线性良好。有机氯农药在0.04、0.01μg/mL两个添加水平的回收率分别为89.5%-113.2%和80.0%-112.7%,相对标准偏差分别为3.82%-9.64%和5.32%-13.8%。拟除虫菊酯在0.2、O.05μg/mL两个添加水平的回收率分别为97.5%-129.6%和87.3%-110.2%,相对标准偏差分别为3.78%-10.72%和3.02%-13.84%。本方法快速、灵敏、准确、可靠,用于江西茶叶样品中有机农药残留测定,获得较好结果。  相似文献   

11.
GC/MS法测定木香挥发油化学成分   总被引:5,自引:0,他引:5  
用气相色谱-质谱法对木香挥发油进行化学成分的分析。采用水蒸气馏法从木香中提取挥发油。试用不同类型的毛细管柱进行分析,找出最佳分析条件,用归一化法测定其含量,并用气相色谱-质谱法对化学成分进行鉴定。共鉴定了38个成分,占挥发油总成分的86%以上。方法稳定可靠。重现性好,适用于中药挥发油的化学成分分析。  相似文献   

12.
气相色谱法分析丙醛加氢制备正丙醇的过程产物   总被引:2,自引:0,他引:2  
利用气相色谱法,选用热导检测器与氢火焰离子化检测器、GDX-102填充柱和OV-1石英毛细管柱,采用外标、内标和校正面积归一化法相结合的定量方法对丙醛加氢制备正丙醇的过程产物中的水分和有机成分进行了定性、定量分析。方法的相对标准偏差为0~1.26%,加标回收率为96.43%~100.48%。  相似文献   

13.
平菇多糖稀溶液行为的研究   总被引:1,自引:0,他引:1  
平菇多糖属生物高分子, 文章对平菇多糖稀溶液性质进行了研究。实验系采用Elias浊点滴定法测定平菇多糖溶液的θ组成, 用快速动态膜渗透计和粘度法测定平菇多糖的数均分子量、维利系数与分子链的构型参数。探讨其在θ条件下的分子形态及用Tung函数法等处理分级数据, 从而获得平菇多糖的分子量分布。  相似文献   

14.
气相色谱法测定蔬菜中有机磷农药的残留量   总被引:8,自引:1,他引:8  
采用DB-1型毛细管柱及氮磷检测器,建立了同时测定蔬菜中有机磷农药甲胺磷、氧化乐果、甲拌磷、甲基对硫磷残留量的气相色谱法,测定4种有机磷农药残留量的线性范围均为0.02-4.00mg/L,相关系数为0.9955~0.9980,检出限为0.0012~0.0020mg/L,加标回收率为89.3%-92.2%,相对标准偏差为2.2%~3.2%。  相似文献   

15.
Summary Gas chromatography with electron capture detection (GC-ECD) for the analysis of methylmercury choloride (MMC) using a packed column and a capillary column has been investigated. The columns were 2% silicone OV-227 Uniport HP glass column and a DB-17 capillary column, each pretreated by about ten injections of HBr-methanol solution. MMC was separated as a sharp peak by the HBr-teated column and determined directly by ECD without derivatisation. The mass spectrum of MMC indicated that halide exchange from chloride to bromide proceeded during separation. The minimum detectable concentrations were approximately 5 ng mL−1 on the packed column, and 2 ng mL−1 on the capillary. Calibration curves showed good linearity between 5–200 ng mL−1 for the packed column, and between 2–200 ng mL−1 for the capillary. Relative standard deviations of peak areas were 0.95% for the packed column and 0.43% for the capillary at the level of 100 ng mL−1 in both cases. The column treatment technique was applicable to determination of methylmercury in fish samples.  相似文献   

16.
以PLOT/Al2O3石英毛细管柱为分析柱,采用氢火焰离子化检测器,建立了测定丙烯中烃类杂质含量的毛细管气相色谱法。丙烯中烃类杂质含量测定结果的相对标准偏差小于5%,分析时间约30min,测定值与国家标准方法基本一致。该方法操作简便,分析速度快,准确度高,重复性好。  相似文献   

17.
气提浓缩仪分析水中痕量挥发性有机物研究   总被引:1,自引:0,他引:1  
本文描述了气提浓缩仪的设计及操作程序用于对水中痕量挥发性有机物的测定。分析物被气提吸附于TenaxGC柱上,然后直接脱附到毛细管气相色谱柱上进行分析,并用FID或MS鉴定。本文除对色谱条件进行优化外,对气提时间和脱附温度等分析操作条件也进行了研究。检测下限为0.01-0.30PPb,峰面积检测精度优于6.9%,对16种化合物的回收率优于74%。  相似文献   

18.
由于燃烧机理和大气化学过程研究的需要,人们对有机化合物分子,如烷烃、烯烃及其衍生物与一些自由基,如O、OH和卤素原子的反应速率常数进行了广泛的测定。但酮类分子与这些自由基的研究则报道得很少,尽管人们早已发现酮类化合物是碳氢化合物被NO_x光氧化过程中产生的中间化合物。就我们所知,除有少量的关于O(~3P))原子与酮类分子反应速率常数测定的文献报道外,我们在前文中报道了用流动微波放电——化学发光方法测  相似文献   

19.
修振佳  程悦生  洪群发 《色谱》1997,15(5):428-430
使用静态涂渍法,在毛细管柱内壁涂渍新型苯撑基色谱固定液,通过原位交联,提高了液膜不可抽提性及稳定性。苯基通常被连接在聚硅氧烷硅原子的侧链上,如果两个硅原子之间通过苯联结而不是通过氧原子联结,则可形成聚苯撑基硅氧烷[1],这种聚硅氧烷的弹性好。采用含50%聚苯撑基硅氧烷研制出交联毛细管柱,并对制备过程重复程度进行了考察,评价了柱子的综合性能,简单介绍了柱子的极性及适用范围。  相似文献   

20.
The screening of agricultural samples to determine 17 synthetic pyrethroids was investigated. Samples were lyophilised without losses of the insecticides, and then extracted with n-hexane. A simple, continuous preconcentration-elution system was developed, which included a silica sorbent column (packed with 50 mg) and used an air stream to carry the eluent (ethyl acetate) which minimised the eluate volume thus increasing the preconcentration factor; so no evaporation step was required. Pyrethroids were determined by gas chromatography-electron capture detection (GC-ECD) by using a 5% phenylmethylpolysiloxane-coated fused-silica capillary column; gas chromatography-mass spectrometry was used to identify the pyrethroids detected by GC-ECD monitoring. Limits of detection varied between 0.1 and 0.8 ng/ml (except for piperonyl butoxide, 25 ng/ml) with linear ranges from 1 to 200 ng/ml; the precision of the method was high (3-6%). Recoveries of 17 insecticides from 14 different agricultural samples fortified at levels of 20-100 ng/g ranged from 66 to 102% (bifenthrin and deltamethrin were those providing the lowest values, 66-87%). Pyrethroids were detected in eight samples (from the 100 unfortified agricultural samples tested) at concentrations lower than the established maximum residue limits (MRLs).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号