首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 750 毫秒
1.
于胜良  杨桂朋  付萌 《色谱》2007,25(4):581-585
建立了用凝胶渗透色谱净化-气相色谱/串联质谱分析蘑菇中36种农药残留的方法。蘑菇中的待测农药组分在30 ℃条件下用乙酸乙酯提取,高速匀浆后通过凝胶渗透色谱净化;选用填料为中性多孔的聚苯乙烯二乙烯基苯微球体的S-X3玻璃柱(22 g,19 cm×2 cm)作为凝胶渗透色谱净化柱,流动相为乙酸乙酯-环己烷(体积比为1∶1)溶液,流速5 mL/min;收集第7~15 min流出的液体用气相色谱-三重四极杆串联质谱仪测定。在0.01~1.0 mg/L的质量浓度范围内,各种农药标准溶液的线性相关系数均大于0.99。在样品中添加36种农药(添加水平为0.01,0.05,0.10 mg/kg)的混合标准溶液,平均回收率为72.6%~117.1%,相对标准偏差为2.0%~10.8%(n=5),最低检出限为 0.1~0.7 μg/kg,最低定量限为 0.2~2 μg/kg。  相似文献   

2.
建立了气相色谱-串联质谱法(GC-MS-MS)同时测定动物脂肪中164种农药的多残留分析方法。样品经乙腈均质提取2次,合并提取液并在45℃水浴中旋转浓缩至1 mL,加入5 mLV(环己烷)∶V(乙酸乙酯)=1∶1进行溶剂交换2次后,用V(环己烷)∶V(乙酸乙酯)=1∶1稀释至10 mL,用凝胶渗透色谱(GPC)净化,GC-MS-MS多反应监测模式(MRM)测定,内标法定量。本方法研究的164种农药的线性相关系数为0.9438~1.0000,其中有154种在0.9900以上,占总数的93.9%。方法检出限(S/N≥3)为0.1~360.0μg/kg,其中在10.0μg/kg以下的有121种,占研究农药总数的73.8%。用猪、鸡、牛、羊4种不同的脂肪在低、中、高3个添加水平评价了164种农药的方法效率,其中有150种的回收率在70%~120%之间,相对标准偏差(RSDs)在20%以内。本方法适用于不同动物脂肪中150种农药多残留的定量测定和14种农药的定性测定。  相似文献   

3.
结合凝胶渗透色谱净化技术,建立了超高效液相色谱-串联质谱法测定水产品中6种同化激素的残留。样品经叔丁基甲醚提取,以乙酸乙酯-环己烷(1+1)溶液为流动相进行凝胶渗透色谱净化,用C18固体吸附剂净化,以C18色谱柱分离,采用电喷雾正离子源、多反应监测模式检测,外标法定量。6种激素的线性范围均为0.5~50μg·L-1,测定下限(10S/N)在0.20~1.50μg·kg-1之间。对空白样品进行加标回收试验,回收率在81.7%~90.8%之间,日间精密度(n=5)在5.8%~7.9%之间。  相似文献   

4.
黄油中8种类固醇激素的液相色谱/串联质谱检测   总被引:1,自引:0,他引:1  
建立了黄油中雌酮、α-雌二醇、β-雌二醇、雌三醇、睾酮、表睾酮、孕酮和丙酸睾酮8种类固醇激素的凝胶渗透色谱(GPC)-液相色谱/串联质谱(LC-MS/MS)检测方法。样品用乙酸乙酯-环己烷(1∶1,V/V)提取,提取液经GPC柱净化除脂,GPC浓缩液采用C18色谱柱(100 mm×2.0 mm i.d.,3.0μm)分离,以乙腈和水为流动相进行梯度洗脱,电喷雾电离多反应监测模式进行定性和定量分析。8种类固醇激素以基质匹配外标法定量,药物在1.0~20.0μg/kg线性范围内相关系数(r)均大于0.999;方法检出限(S/N=3)为0.04~0.30μg/kg,定量限LOQs(S/N=10)为1.0μg/kg;添加水平为1.0,2.0,4.0μg/kg时,回收率范围在64.1%~110%之间;相对标准偏差(RSD)小于11%。结果表明,本方法准确、可靠,满足黄油中8种类固醇激素的检测分析要求。  相似文献   

5.
应用凝胶色谱/超高效液相色谱-串联三重四极杆质谱建立了饲料中16种脂溶性染料测定的新方法。样品经20 m L乙酸乙酯-环己烷(1∶1)提取,凝胶色谱系统净化后,以0.1%甲酸溶液-甲醇为流动相进行梯度洗脱,各脂溶性染料经C18柱得到良好分离。16种染料在2~100μg/L范围内线性关系良好,相关系数(r2)不小于0.99。其检出限为25μg/kg,定量下限为50μg/kg。饲料样品在低、中、高3个加标浓度下,16种脂溶性染料的回收率为66.4%~108.5%,结果表明方法适用于饲料中16种脂溶性染料的检测。该方法操作简单、准确、杂质干扰少。  相似文献   

6.
凝胶柱净化-高效液相色谱检测食品中的苏丹红   总被引:13,自引:0,他引:13  
谢维平  黄盈煜  傅晖蓉  胡桂莲 《色谱》2005,23(5):542-544
建立了凝胶柱净化-高效液相色谱同时检测食品中苏丹红Ⅰ,Ⅱ,Ⅲ和Ⅳ的方法。样品用乙醇提取,提取液经Bio-Beads SX3凝胶柱(200 mm×10 mm i.d.)净化,用环己烷-乙酸乙酯(体积比为1∶1)洗脱。采用Symmetry Shield RP18柱(250 mm×4.6 mm i.d., 5 μm)分离,以100%甲醇为流动相,流速1.5 mL/min;用二极管阵列检测器检测,检测波长478 nm。上述4种苏丹红组分在其质量浓度为0.1~10.0 mg/L时有良好的线性关系(r>0.999),方法的检测限为7~14 μg/kg;平均加标回收率为80.7%~96.3%(添加水平为0.25,2.5 mg/kg),相对标准偏差为2.4%~5.9%。方法灵敏可靠,能满足食品中苏丹红检测的需要。  相似文献   

7.
建立了用凝胶渗透色谱-高效液相色谱测定茶叶中蒽醌的方法。以乙酸乙酯、乙酸乙酯-正己烷(1∶1,V/V)液液萃取,凝胶渗透色谱净化,收集时间为11~17 min,以甲醇+0.5%H3PO4溶液(65+35,V/V)为流动相,ZORBAX SB-C18分离,外标法定量。蒽醌质量浓度在10~200μg/L范围内线性关系良好,相关系数r为0.9993,检出限为6μg/kg,定量限为10μg/kg。茶叶样品在10,50,180μg/kg 3个加标浓度下,蒽醌的回收率为73.2%~97.5%,相对标准偏差为4.0~7.9%。  相似文献   

8.
高效液相色谱-荧光检测法分析麦类中麦角克列斯汀碱   总被引:1,自引:0,他引:1  
提出了一种采用高效液相色谱-荧光检测法(HPLC-FLD)测定麦类样品中麦角克列斯汀碱的方法。麦类样品经V(乙腈)∶V(0.1 mol/L乙酸铵缓冲溶液)=1∶4提取,以C18小柱净化,C18色谱柱(4.6×250 mm,5μm)分离,V(水)∶V(乙腈)=3∶2作流动相,流速1.0 mL/min,以HPLC-FLD定量测定。标准工作溶液浓度在1.0~50.0μg/L范围内,与峰面积成良好的线性关系,线性相关系数0.9999,样品在10.0、50.0、250.0μg/kg添加水平的回收率为76%~85%,相对标准偏差(RSD)为6.6%~8.8%(n=8),方法检测限为5.0μg/kg(S/N10)。  相似文献   

9.
凝胶色谱-气相色谱-串联质谱法筛查茶叶中27种禁用农药   总被引:1,自引:0,他引:1  
建立了茶叶中27种国家禁用农药的气相色谱-串联质谱分析方法。以27种国家禁用农药为目标分析物,样品经环己烷-乙酸乙酯超声提取、凝胶渗透色谱净化后进行定性和定量分析。方法检出限为0.02~2.82μg/kg,方法定量限为0.07~9.40μg/kg,在0.01~0.20 mg/L范围内方法线性相关系数均大于0.991,75%以上的农药的回收率在70%~110%之间,相对标准偏差在0.53%~7.1%之间。方法适用于茶叶中多种农药残留的检测分析。  相似文献   

10.
称取试样约5g(精确至0.01g),加入1.000 mg·L~(-1)甲萘威-D7同位素内标溶液50μL,加入适量水(肉样加水1.5mL,肉制品加水3mL),加40mL丙酮,均质1min,加氯化钠6g,充分摇匀,再加30mL石油醚,振摇30min,静置30min。取有机层上清液,经无水硫酸钠过滤,旋转蒸发浓缩至约1mL,加2mL乙酸乙酯-环己烷(1+1)混合液,再浓缩至约1mL,如此重复3次。用乙酸乙酯-环己烷(1+1)溶液定容至10.0mL,经0.22μm滤膜过滤,进行凝胶色谱(GPC)净化。GPC条件如下:Bio Beads S-X3凝胶色谱净化柱(400mm×30mm),乙酸乙酯-环己烷(1+1)混合液为流动相,馏分收集段10.0~15.0min,在线浓缩加热温度45℃,真空度2.0×10~4Pa。以乙腈为替换溶剂替换两次后将净化液定容至1.0mL,进行液相色谱-串联质谱分析。采用HSS T3色谱柱(100mm×2.1mm,1.7μm)进行分离,以0.1%(体积分数)甲酸溶液-乙腈(6+4)为流动相,质谱分析中采用电喷雾正离子源和多反应监测模式。甲萘威的质量浓度在0.010~0.500mg·L~(-1)内和其峰面积与内标峰面积之比呈线性关系,测定下限(10S/N)为0.005mg·kg~(-1)。加标回收率在81.0%~105%之间,测定值的相对标准偏差(n=6)在3.8%~16%之间。  相似文献   

11.
A new method using gel permeation chromatography (GPC) cleanup followed by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) has been established for quantitative determination of 437 pesticide residues in animal tissues such as beef, mutton, pork, chicken, and rabbit. Based on an appraisal of the characteristics of both GC-MS and LC-MS-MS, validation experiments were conducted for 660 pesticides. In the method, 10 g animal samples were mixed with 20 g sodium sulfate and extracted with 35 mL of cyclohexane+ethyl acetate (1+1) twice by blender homogenization, centrifugation, and filtration. Evaporation was conducted and an equivalent of 5 g sample was injected into a 400 mm x 25 mm S-X3 GPC column, with cyclohexane+ethyl acetate (1+1) as the mobile phase at a flow rate of 5 mL/min. The 22-40 min fraction was collected for subsequent analysis. For the 368 pesticides determined by GC-MS, the portions collected from GPC were concentrated to 0.5 mL and exchanged with 5 mL hexane twice. For the 69 pesticides by LC-MS-MS, the portions collected from GPC were dissolved with acetonitrile+water (60+40) after taking the extract to dryness with nitrogen gas. In the linear range of each pesticide, the correlation coefficient was r > or = 0.98, exceptions being dinobuton, linuron, and fenamiphos sulfoxide. At the low, medium and high three fortification levels of 0.2-4800 microg/kg, recoveries fell within 40-120%, among which 417 pesticides recoveries between 60% and 120%, accounting for 95%, 20 analytes between 40% and 60%, accounting for 5%. The relative standard deviation was below 28% for all 437 pesticides. The limits of detection for the method were 0.2-600 microg/kg, depending on each pesticide.  相似文献   

12.
雒丽丽  薄海波  毕阳  吴永隆 《色谱》2009,27(2):201-205
建立了多种水果和饮料中氟嘧菌酯和嘧螨酯残留的超高效液相色谱测定方法。样品用乙酸乙酯-环己烷(体积比为1∶1)超声波萃取,凝胶渗透色谱法净化,超高效液相色谱-二极管阵列检测器检测,外标法定量。采用BEH C18色谱柱(50 mm×2.1 mm,1.7 μm),流动相为水-乙腈(体积比为3∶7),流速为0.3 mL/min,柱温为40 ℃,紫外检测波长为251 nm。实验结果表明:氟嘧菌酯和嘧螨酯在0.05~2 mg/L范围内线性关系良好(r>0.999),在不同的基质中添加3个浓度水平(0.01,0.05,0.1 mg/kg)的氟嘧菌酯和嘧螨酯,两者的回收率均在82.60%~101.11%之间,相对标准偏差为5.4%~15.3%;检出限不大于6 μg/kg,定量限不大于20 μg/kg。  相似文献   

13.
杨昌金  覃宁  利红宇  何成建 《色谱》1997,15(5):448-450
报道了用甲醇-水-乙酸(56413,体积比)为流动相,在HypersilODS柱上以愈创木酚甘油醚为内标,采用电化学检测器(ECD)测定人体脑组织中鬼臼甲叉甙含量。回收率92.87%,最低检测浓度为0.1mg/L,鬼臼甲叉甙在0.1~10.0mg/L范围内呈线性,工作电压0.70V。同时还对脑瘤患者脑组织中正常部位和肿瘤部分中鬼臼甲叉甙含量进行了测定。  相似文献   

14.
建立了液相色谱-串联质谱法同时测定动物脂肪中111种农药残留的分析方法.样品经乙腈均质提取2次,旋转蒸发浓缩后经过凝胶渗透色谱净化.111种农药在Atlantis T3柱上以乙腈和0.1%甲酸溶液为流动相,梯度洗脱条件下完成分离,采用电喷雾电离串联质谱在正离子多反应监测模式下进行测定.目标化合物的保留时间为2.4 ~33.8 min,线性相关系数为0.984 5 ~0.999 9;在4种动物脂肪中分别添加1倍、2倍、4倍定量下限3个水平的平均回收率为60% ~120%,相对标准偏差为0.6% ~19.8%;111种农药在动物脂肪中的检出限为0.20 ~960 μg/kg,定量下限为0.40 ~2 400 μg/kg.该方法操作简单、灵敏度高、选择性好,符合农药多残留分析的要求.  相似文献   

15.
采用对氨基苯甲酸乙酯为衍生化试剂,建立柱前衍生化反相高效液相色谱法(RP-HPLC)测定2-去氧葡萄糖的含量.结果表明,最适的衍生化条件为反应温度85℃,反应时间1.5 h,衍生化试剂(ABEE)和单糖(2-DG/Glu)的摩尔比为25∶1;色谱条件为色谱柱Hypersil ODS2 (250 mm×4.6 mm,5μm),流动相为0.02%TFA-乙腈(80∶20,V/V),流速1.0 mL/min,波长307 nm.本方法在1~700 mg/L浓度范围内与峰面积呈良好的线性关系(r-0.9999);定量限(S/N-10)及检出限(S/N-3)分别为450和100 μg/L;平均加标回收率为101.7%;RSD为0.7%;日内及日间精密度均小于0.7%.表明本方法灵敏度高,测定结果准确,重复性好,可用于2-去氧葡萄糖样品的准确定量分析.  相似文献   

16.
高聚物型色谱柱分离乙酰半胱氨酸及其有关物质   总被引:2,自引:0,他引:2  
考察高聚物型色谱柱(聚苯乙烯-二乙烯基苯(PS-DVB)麦科菲反相高效液相色谱柱,MKF-RP-MH)分离乙酰半胱氨酸以及有关物质的适用性。采用MKF-RP-MH色谱柱(4.6×250 mm,5μm),V(0.02 mol/L的磷酸盐缓冲液(pH 3.0))∶V(乙腈)=9∶1为流动相,流速为1 mL/min,检测波长210 nm,柱温为25℃。乙酰半胱氨酸峰与有关物质峰的分离度均大于1.5;乙酰半胱氨酸质量浓度在11~111 mg/L的范围内,具有良好的线性关系,回归方程为A=18.195ρ+0.5229,r=0.9995(n=8);乙酰半胱氨酸的定量限为11 mg/L;最低检测限为0.035μg;进样精密度RSD=0.24%(n=6)。  相似文献   

17.
应用现代提取技术超声-微波协同萃取金线莲中的3-吡啶甲醇,采用固相萃取技术对样品进行前处理,高效液相色谱法-电喷雾电离/离子阱质谱法(HPLC-ESI/MS)对提取物中3-吡啶甲醇进行测定和鉴别.色谱条件:Agilent TC-C18色谱柱(5 μm,4.6×250 mm),流动相:甲醇-0.02 mol/L乙酸铵(5∶95,V/V),流速:1 mL/min,检测波长:260 nm.结果表明峰面积与3-吡啶甲醇在浓度1~10 μg/mL范围内呈良好线性关系.回收率在92.0%~96.2%之间,相对标准偏差为2.36%.该法简便、准确、快速.  相似文献   

18.
闫小燕  靳艳  虞星炬  张卫  金美芳 《色谱》2004,22(6):652-654
采用气相色谱-质谱联用技术(GC-MS)与核磁共振氢谱(1H-NMR)相结合的方法,对中国黄海肾指海绵属新种海绵Reniochalina sp.中的低极性组分进行了研究。实验首先采用环己烷对海绵进行提取,然后将提取液浓缩,用硅胶柱对其进行柱色谱分离。取乙酸乙酯-环己烷(体积比为1∶9)混合液梯度洗脱所得油状物用于连续两次制备色谱分离,得到两个样品,对其进行1H-NMR及GC-MS分析。此次实验共从该海绵中分离鉴定出10种链烃、2种脂肪酸、2种脂肪酸酯、邻苯二甲酸以及3种邻苯二甲酸二酯共18种化学成分。该研  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号