首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
高效液相色谱法快速检测猪组织中泰妙菌素残留   总被引:4,自引:1,他引:3  
应用高效液相色谱法测定猪组织中泰妙菌素残留.试样经磷酸盐缓冲液(pH 8.0)-乙酸乙酯混合提取,离心后加0.1%酒石酸,40 ℃旋转蒸发,除尽有机相,加正已烷除脂,HLB柱净化后,氮气吹干,0.0125%甲酸溶解后HPLC检测.流动相为乙腈-0.0125%甲酸(42∶ 58,V/V).紫外检测波长为210 nm.对猪肉(猪肝)进行15(25)~500 μg/kg的药物添加回收实验,结果表明,泰妙菌素的平均回收率为80.1%~92.7%; 日内相对标准偏差为2.0%~10.2%;日间相对标准偏差为5.9%~13.9%.按信噪比S/N=3计算,猪肉和猪肝中泰妙菌素的检出限(LOD)分别为4.5和7.5 μg/kg.  相似文献   

2.
利用高效液相色谱-电喷雾串联四极杆质谱(HPLC-MS/MS)联用技术,建立了一种在28 min内快速分离和测定鸡肉、猪肉、牛肉、羊肉、蜂蜜、牛奶中24种磺胺类药物残留的方法.方法检出限(LOD)为0.27~7.45μg/kg,定量限(LOQ)0.957~9.89 μg/kg;在5~300μg/L范围内线性关系良好,在10、20、50μg/kg 3个添加浓度上回收率为60.8%~122.9%,相对标准偏差(PSD)为0.01%~19%.  相似文献   

3.
建立了高效液相色谱-串联质谱(HPLC-MS/MS)法同时测定鸡蛋中头孢噻肟及其代谢物去乙酰头孢噻肟残留量的检测方法.样品经乙腈-水(9∶1, V/V)提取,正己烷除脂,C18固相分散萃取除杂,Agilent Eclipse Plus C18色谱柱(100 mm×2.1 mm, 3.5 μm)分离,以0.2%(V/V)甲酸-乙腈为流动相,进行梯度洗脱,目标物采用电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式检测,基质匹配标准溶液外标法定量.结果表明,头孢噻肟和去乙酰头孢噻肟分别在1.0~143.0 μg/L和1.0~120.0 μg/L浓度范围内线性关系良好(R.2>0.999).方法检出限(LOD, S/N=3)分别为0.07和0.14 μg/kg,定量限(LOQ, S/N=10)分别为0.23和0.99 μg/kg. 在5.0、50.0和100.0 μg/kg 3个添加水平下,头孢噻肟和去乙酰头孢噻肟的回收率分别为83.1%~103.0%和88.2%~101.0%,相对标准偏差(RSD, n=6)均介于2.0%~6.2%.实际样品测定结果表明,本方法简便、快速、灵敏、准确, 可用于鸡蛋中头孢噻肟及去乙酰头孢噻肟的残留分析检测.  相似文献   

4.
采用超高效液相色谱-四极杆串联质谱仪(UPLC-MS/MS)同时测定了猪肝中18种非甾体类抗炎药(NSAIDs)的残留量.对NSAIDs多残留同时提取、净化技术进行了研究,对UPLC-MS/MS检测参数进行了优化.均质后的猪肝样品采用酸化乙腈提取,正己烷液-液分配(LLP)脱脂,经硅胶固相萃取(SPE)柱净化后,采用UPLC-MS/MS电喷雾电离(ESI),多反应监测(MRM)模式检测,以保留时间和子离子比定性,外标法定量.方法检出限(LOD)为0.2~10 μg/kg;定量限(LOQ)为1.0~50 μg/kg.在添加浓度在1.0~200 μg/kg范围内,NSAIDs的回收率在53.8%~92.7%之间,相对标准偏差(RSD)小于10.3%.方法操作简便,对动物肌肉、内脏、鸡蛋及牛奶中NSAIDs残留的检测具有普遍适用性.  相似文献   

5.
建立了水产品中喹哪啶麻醉剂残留量的高效液相色谱荧光法检测方法。样品采用1%三氯乙酸-乙腈混合溶液提取,经混合型阳离子交换固相萃取柱净化,0.02 mol/L NH_4H_2PO_4溶液-乙腈(65:35,V:V)为流动相,ZORBAX Eclipse XDB-C_(18)色谱柱分离,荧光检测器,激发波长为238 nm,发射波长为417 nm,外标法定量。结果表明,喹哪啶麻醉剂在10~500μg/L范围内呈现良好线性关系,相关系数(R~2)为0.9999,回收率为74.5%~100.6%,相对标准偏差为1.6%~7.5%,方法检出限(LOD)为0.015 mg/kg,定量限(LOQ)为0.050 mg/kg。该方法可满足水产品中喹哪啶麻醉剂残留分析的要求。  相似文献   

6.
建立一种用超高效液相色谱-电喷雾质谱联用技术测定乳制品中三聚氰胺残留量的方法.样品经含5%乙酸铅的三氯乙酸溶液提取,离心分离后经PCX-C18混合填料固相萃取柱净化.色谱分离采用Agilent ZORBAX-CN柱(250 mm×4.6 mm i.d.,5 μm),以10 mmol/L V(乙酸铵)∶V(乙腈)=10∶90混合溶液为流动相.采用电喷雾离子源,正离子多反应监测(MRM)模式检测.该方法在1~1000 ng/mL范围内线性关系良好.在添加水平为10,30,45 μg/kg时,回收率在78.5%~92.6%之间,相对标准偏差在3.5%~8.6%之间,检出限为10 μg/kg.该方法适合于乳制品中三聚氰胺残留量的检测.  相似文献   

7.
液相色谱-串联质谱同时测定动物组织中22种同化激素   总被引:8,自引:2,他引:6  
采用高效液相色谱-电喷雾串联质谱仪(LC-ESI-MS-MS),在多反应监测(MRM)模式下建立了动物组织中甾体类和1,2-二苯乙烯类22种同化激素(睾酮、甲基睾酮、丙酸睾酮、苯丙酸诺龙、勃地龙、康力龙、群勃龙、醋酸群勃龙、丙酸诺龙、大力补、醋酸甲羟孕酮、诺龙、孕酮、甲炔诺酮、甲羟孕酮、雌酮、雌二醇、雌三醇、炔雌醇、己烷雌酚、己烯雌酚、双烯雌酚)的快速确认测定方法.试样中的药物经叔丁基甲醚提取后,过C18固相萃取柱净化,氮吹至干,用1 mL乙腈/水(1:1,V/V)定容后测定.采用正离子扫描和负离子扫描的方式进行仪器方法学研究,确定丰度比最高的2对离子作为监测离子,进行MRM模式定性定量分析.该方法的检出限(LOD)为0.2~0.5 μg/kg,定量限(LOQ)为0.5~1.0 μg/kg;在2.0~200.0 μg/L的线性范围,相关系数r均大于0.998.在1.0 μg/kg的添加水平上,上述22种激素的平均回收率为56.2%~112.3%,相对标准偏差为2.6%~13.2%.本法操作简单,灵敏度高,可用于动物组织中22种同化激素的残留测定.  相似文献   

8.
应用快速高分离液相色谱-串联质谱仪(RRLC-MS/MS),建立了植物组织中玉米赤霉醇类化合物(α-玉米赤霉醇、β-玉米赤霉醇、α-玉米赤霉烯醇、β-玉米赤霉烯醇、玉米赤霉酮、玉米赤霉烯酮)的检测方法.植物组织样品采用乙腈提取,碱性水溶液反萃取,经混合阴离子(MAX)固相萃取柱进行净化和富集后,用RRLC-MS/MS检测,多反应监测(MRM)模式下进行定性与定量分析.结果表明:玉米赤霉醇类化合物在0~20 μg/kg的线性范围内均具有良好的线性关系,方法检出限(LOD)为0.5 μg/kg,定量限(LOQ)为1.0 μg/kg,6种玉米赤霉醇类化合物的平均回收率为75.8%~105.4%,相对标准偏差为2.4%~12.1%.本方法可用于植物组织中玉米赤霉醇类化合物含量的测定.  相似文献   

9.
高效液相色谱-电喷雾串联质谱法测定蜂蜜中5种头孢菌素   总被引:2,自引:0,他引:2  
建立了用高效液相色谱-电喷雾串联质谱(LC-MS-MS)测定蜂蜜中5种头孢菌素残留量的方法.蜂蜜样品用磷酸盐缓冲溶液溶解,经Oasis HLB固相萃取柱净化.5种头孢菌素在C18柱上以乙腈-水为流动相梯度洗脱条件下完成分离,电喷雾电离串联质谱在正离子多反应监测模式下进行测定.添加浓度在2~100 μg/kg范围时,回收率为84.2%~103.6%; 相对标准偏差为3.89%~9.08%.本方法头孢唑啉的定量限为10 μg/kg, 头孢匹林、头孢氨苄、头孢洛宁、头孢喹肟的定量限为2.0 μg/kg.  相似文献   

10.
建立了同时测定蔬菜中氯吡苯脲、除虫脲、灭幼脲、杀铃脲、氟铃脲、氟丙氧脲、氟苯脲、氟啶蜱脲、氟虫脲、丁醚脲、氟啶脲11种苯甲酰脲类农药残留的液相色谱-串联质谱分析方法.试样经乙腈提取,N-丙基乙二胺(PSA)和C18填料分散固相萃取净化,C18柱反相液相色谱分离,以甲醇-0.005 mol/L醋酸铵溶液为流动相梯度洗脱,电喷雾负离子模式离子化,多反应监测方式监测,三重四极杆质谱测定.结果表明:试样中添加10、20、50 μg/kg的11种苯甲酰脲类农药,回收率为69% ~109%,相对标准偏差小于16%(n=5).该方法操作简便、稳定性好、灵敏度高,检出限(LOD)为3 μg/kg,定量下限(LOQ)为10 μg/kg.  相似文献   

11.
建立了固相萃取-高效液相色谱-串联质谱法测定禽畜和水产品中沃尼妙林、泰妙菌素残留量的分析方法。匀浆样品用乙腈水提取,经盐析和乙腈饱和正己烷除脂后过Oasis MCX SPE小柱净化,采用LC-MS/MS电喷雾电离(ESI)和多反应监测模式(MRM)检测,外标法定量。沃尼妙林和泰妙菌素的检出限均为1.0μg/kg,在1.0~100μg/kg范围内线性关系良好,相关系数r均大于0.99。在1.0~50.0μg/kg的加标水平内的回收率为80.9%~104.3%,RSD为4.7%~7.8%。  相似文献   

12.
液相色谱-串联质谱法同时检测饲料中7种精神类药物   总被引:1,自引:0,他引:1  
建立了液相色谱-串联质谱同时检测饲料样品中7种精神类药物(硝西泮、奥沙西泮、氯丙嗪、异丙嗪、地西泮、奋乃静、硫利达嗪)的方法.通过对提取溶剂、净化等预处理条件及LC-MS/MS 分析条件的优化,可以同时检测饲料中7种违禁精神类药物.饲料样品经乙腈/水(9:1, V/V)提取后,过MCX固相萃取柱净化,氮吹至干,用1 mL乙腈/水(2:8, V/V)溶解后测定,采用SRM模式进行定性与定量分析.7种精神类药物在饲料中的回收率为53.9%~110.2%; 相对标准偏差为3.4%~18.4%;硝西泮、奥沙西泮、氯丙嗪、异丙嗪的检出限为1.0 ng/g;对地西泮、奋乃静、硫利达嗪的检出限为5.0 ng/g.结果表明,本方法可用于饲料中7种精神类药物的测定.  相似文献   

13.
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 μl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01–0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.  相似文献   

14.
液相色谱串联质谱法测定蔬菜中四聚乙醛残留量   总被引:2,自引:0,他引:2  
建立了测定蔬菜中四聚乙醛残留量的液相色谱串联质谱方法.蔬菜样品经乙腈提取,盐析后吹干乙腈提取液,再用氟罗里硅土固相萃取小柱净化,用正已烷/丙酮(80:20,V/V)混合溶剂洗脱,氮吹后用乙腈-20mmol/L,乙酸铵溶液(70:30,V/V)溶解后进行仪器分析.分析采用XBridgeTM C18色谱柱分离,乙腈-20m...  相似文献   

15.
在3种不同的纤维素手性柱上,对亚砜类手性杀虫剂乙虫腈对映体进行了反相高效液相色谱拆分研究,通过优化手性色谱柱和流动相,实现了乙虫腈对映体基线分离,结合液相色谱-圆二色检测器分析,柱流出顺序为(+)-、(-)-对映体,并在此基础上建立了稻米中乙虫腈对映异构体残留量的高效液相色谱-串联质谱分析方法.稻米样品加水浸润,乙腈高速匀浆、盐析,上清液旋转浓缩后经氨基固相萃取柱净化,洗脱液经氮气吹干后定容.采用纤维素-三(3-氯-4-甲基苯基氨基甲酸酯)(Lux Cellulose-2)手性色谱柱,以甲醇-水(60∶40,V/V)为流动相,液相色谱-串联质谱电喷雾负离子扫描进行分析,外标法定量.以精米和糙米为基质进行3个添加水平和5次重复性实验,结果表明:添加浓度为0.01~0.2 mg/kg,样品中乙虫腈单一对映体平均添加回收率为87.4%~97.8%,相对标准偏差(RSD,n=5)为3.1%~9.3%,方法检出限(LOD)为0.001 mg/kg,定量限(LOQ)为0.003 mg/kg.  相似文献   

16.
液相色谱-串联质谱法测定水产品中麻醉剂MS-222残留   总被引:3,自引:0,他引:3  
建立了液相色谱-串联质谱法测定水产品中麻醉剂3-氨基苯甲酸乙酯甲基磺酸盐(MS-222)残留量的方法。提取液为50%的甲醇及乙酸-乙酸钠缓冲溶液,提取液经C18固相萃取柱净化处理后用液相色谱-串联质谱仪进行测定,外标法定量。流动相为0.5%的甲酸溶液和乙腈(V:V=60:40),流速为0.2 mL/min。该方法的线性范围为0.001~1.0 mg/L,相关系数大于0.999,检出限为1μg/kg,定量限为2μg/kg。加标回收率可以达到80%~110%。  相似文献   

17.
采用液相色谱-串联质谱法(LC-MS/MS)测定了水产品中结晶紫以及它的隐色代谢物残留。匀质后的水产品样品用乙腈和乙酸铵缓冲液提取,合并提取液,用二氯甲烷反提取,经中性氧化铝柱和PRS柱固相萃取净化,且不使用氧化铅柱在线氧化,色谱分离后直接进入串联质谱检测器。采用电喷雾正离子,多反应监测(MRM)模式检测。方法的检出限可达0.5 ng/g,线性方程的相关系数r大于0.99,添加样品平均回收率为77.6%~93.8%,相对标准偏差均小于8.2%。  相似文献   

18.
建立了动物源食品中粘杆菌素和多粘菌素B残留的高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品用V(10%三氯乙酸水溶液):V(乙腈)=30:70提取,Oasis WCX SPE柱净化,LC-MS/MS电喷雾正离子多反应监测模式(ESI+-MRM)检测。分析物在0~250μg/kg的浓度范围内呈良好线性,线性相关系数>0.995。方法的定量限为10μg/kg。方法在三个添加水平的平均回收率在71.6%~78.9%之间,相对标准偏差在6.2%~12%之间。方法适用于动物源食品中粘杆菌素和多粘菌素B的定量及确证检测。  相似文献   

19.
建立了谷物及其制品中脱氧雪腐镰刀菌烯醇、3-乙酰脱氧雪腐镰刀菌烯醇、15-乙酰脱氧雪腐镰刀菌烯醇、去环氧脱氧雪腐镰刀菌烯醇的同位素稀释-超高效液相色谱-线性离子阱串联质谱( UHPLC-QTRAP-MS/MS)定性确证和定量测定方法。样品经乙腈-水(84:16, V/V)混合溶液提取,乙腈饱和的正己烷除脂,HLB固相萃取柱净化,Waters Atlantis? T3色谱柱分离,以乙腈-0.02%氨水溶液为流动相进行梯度洗脱,在负离子模式下,采用多反应监测( MRM)-信息依赖性采集( IDA)-增强子离子扫描( EPI)模式检测,在线EPI谱库定性分析,同位素内标定量,在1~300μg/L 浓度范围内,4种目标物的线性相关系数均大于0.999,检出限为0.1μg/kg,定量限为0.3μg/kg,添加5,50和200μg/kg的3个浓度水平,4种目标物的平均回收率均在81.3%~101.7%之间,相对标准偏差均小于5%,将该技术应用于FAPAS阳性玉米质控样品和5种代表性的样品进行测试,结果表明,本方法简单、准确、快速,适用于谷物及其制品中呕吐毒素及其衍生物和代谢物的快速确证和定量测定。  相似文献   

20.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for determining the residues of malachite green (MG) and leucomalachite green (LMG) in a number of aquatic species. MG and its metabolite were extracted from homogenized tissues with a perchloric acid-acetonitrile solution; the extract was centrifuged; and an aliquot was taken, concentrated, and passed through a chemically bonded octadecyl C18 solid-phase extraction column. The compounds of interest were eluted with acetonitrile, and the eluate was evaporated to dryness. The residue was dissolved in acetonitrile and diluted with water in preparation for analysis by LC/MS/MS. MG and its metabolite were determined by reversed-phase LC using a Luna C18 column with an ammonium hydroxide-formic acid buffer in acetonitrile gradient and MS/MS detection using multiple reaction monitoring. Calibration curves were linear for all analyses between 5 and 500 pg injected for both analytes, with recoveries ranging from 81% for LMG to 98% for MG in salmon spiked at the 1 ng/g level. Detection limits of 0.1 ng/g for both MG and LMG were easily obtainable using the recommended method. The operational errors, interferences, and recoveries for spiked samples compared favorably with those obtained by established methodology. The recommended method is simple, rapid, and specific for monitoring residues of MG and LMG in a number of aquatic species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号