首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
介绍高浓度血清雌二醇标准物质的研制。采集的全血不加任何添加剂和抗凝剂,离心分离出血清,分装。采用同位素稀释–液相色谱串联质谱法(ID–LC–MS/MS)对高浓度血清雌二醇标准物质进行定值及均匀性和稳定性检验,对定值不确定度进行了评定。结果表明,高浓度血清雌二醇标准物质定值结果为3.06 ng/g,扩展不确定度为0.08 ng/g(k=2),均匀性和稳定性符合国家标准物质技术要求。采用IFCC RELA比对样品和欧洲标准局标准物质血清17β-雌二醇标准物质对定值方法进行确认,测量结果的标准偏差在该标准物质量值的不确定度范围内。研制的标准物质量值经过日本计量院验证,测量结果为(3.03±0.1)ng/g。该标准物质的量值具有溯源性和准确性。  相似文献   

2.
通过饲喂牛的方式获得乳粉中黄曲霉毒素M1阳性乳品,经冷冻干燥、混匀、包装、分装、辐照灭菌制备了乳粉中黄曲霉毒素M1标准物质。6家实验室均采用液相色谱-同位素稀释质谱法对乳粉中黄曲霉毒素M1标准物质进行联合定值。分别采用F检验和t检验对标准物质进行均匀性、稳定性检验,结果表明该标准物质均匀性与稳定性良好,均符合标准物质定值技术要求。对定值结果进行不确定度评定,乳粉中黄曲霉毒素M1残留标准物质定值结果为(2.45±0.41)μg/kg,k=2。该标准物质可用于乳品中黄曲霉毒素M1的日常质量控制及定量检测。  相似文献   

3.
皮质醇是一种重要的肾上腺皮质激素,同时也是一种重要的临床诊断标志物,为保证检测结果具有溯源性、可比性和准确性,研制了血清中皮质醇成分分析标准物质。对血清样品进行分离、过滤、混匀、分装,进行均匀性检验、稳定性考察和定值分析。采用超高效液相色谱–同位素稀释串联质谱(UPLC–ID–MS/MS)法进行定值,混合健康男性血清和健康女性血清中皮质醇的定值结果分别为107.63 ng/g(U=1.44 ng/g,k=2),92.24 ng/g(U=1.68 ng/g,k=2)。采用CCQM–K63a比对样品对定值方法进行验证,测量结果在该比对参考值的不确定度范围内。研制的皮质醇成分分析标准物质符合国家一级标准物质技术要求。  相似文献   

4.
采用重量-容量法制备丙酮中除虫脲溶液标准物质。准确称量国家二级标准物质除虫脲溶解到色谱纯丙酮中,通过A级容量瓶定容至500 mL,摇匀后分装到2 mL安瓿瓶内共460瓶,每瓶为1 mL,保持低温迅速封口,配制过程中室温保持在(20±2)℃。采用液相色谱法进行均匀性、稳定性检验和定值结果验证。从样品中随机抽取16瓶进行均匀性检验,经F检验表明,在95%的置信区间范围内该标准物质均匀性良好;采用t检验对标准物质稳定性进行检验,标准物质在12月内稳定性良好。对该标准物质的不确定度进行了评定,研制的丙酮中除虫脲溶液标准物质定值结果为100μg/mL,相对扩展不确定度为2%(k=2)。结果表明,该标准物质均匀性与稳定性良好,量值准确,可用于日常分析检测中的方法评价和仪器校准。  相似文献   

5.
采用重量–容量法制备了液相色谱检定用200μg/m L的甲醇中胆固醇标准物质,分别用F检验和回归曲线法对研制的标准物质进行了均匀性和稳定性检验,对定值结果的不确定度进行了评定。结果表明,研制的甲醇中胆固醇标准物质具有良好的均匀性和稳定性,定值结果的相对扩展不确定度为2%(k=2)。该标准物质可用于液相色谱仪示差折光检测器、蒸发光散射检测器的检定。  相似文献   

6.
研制了一种河鲀毒素(Tetrodotoxin)自然基质阳性质控样品,通过阳性样品稀释和阴性样品标准添加制备,6家协作实验室用液相色谱-串极质谱法(HPLC-MS/MS)进行检验定值和不确定度评估,确定质控样中河鲀毒素的特性值与不确定度为(200.08±0.94)μg/kg。结果表明该质控样的均匀性和稳定性符合要求,可用于水产品中河鲀毒素检测的质量控制。  相似文献   

7.
介绍水中苯甲酸钠标准物质的制备方法。以苯甲酸钠为原料,采用重量–容量法制备溶液标准物质,以液相色谱–紫外可见分光光谱法对标准物质进行均匀性和稳定性检验,并对该标准物质定值结果的不确定度进行评定。结果表明,研制的水中苯甲酸钠标准物质的定值结果为(23.6±0.3) mg/L,有效期为6个月。该标准物质具备良好的均匀性和稳定性,可用于食品防腐剂苯甲酸分析方法的确认与评价。  相似文献   

8.
采用重量–容量法研制了气相色谱–质谱(GC–MS)校准用100.1 pg/μL异辛烷中八氟萘溶液标准物质,分别用F检验和回归曲线法对研制的溶液标准物质进行了均匀性和稳定性检验,对定值结果的不确定度进行了评定。结果表明,研制的异辛烷中八氟萘溶液标准物质具有良好的均匀性和稳定性,定值结果的相对扩展不确定度为3%(k=2)。该标准物质可用于GC–MS联用仪的EI源及负CI源的信噪比校准。  相似文献   

9.
采用称量法制备空气中偏二甲肼气体标准物质,分别用F检验和回归曲线法对研制的标准物质进行均匀性和稳定性检验。结果表明,研制的空气中偏二甲肼气体标准物质具有良好的均匀性和稳定性,定值结果分别为10,500μmol/mol,定值结果的相对扩展不确定度为2%(k=2)。该标准物质可用于偏二甲肼报警器的检定或校准。  相似文献   

10.
以淫羊藿提取物为原料,通过正相硅胶柱色谱和凝胶柱色谱等分离纯化手段,研制了宝藿苷Ι纯度标准物质。采用液相色谱–质谱法和核磁共振技术对宝藿苷Ⅰ纯度标准物质进行定性鉴定,利用高效液相色谱(HPLC)法和胶束电动毛细管色谱(MECC)法对宝藿苷Ι的纯度进行定值分析,同时利用HPLC法对宝藿苷Ι纯度标准物质进行均匀性检验与稳定性考察,通过F检验和t检验法对其均匀性进行检验,表明瓶间和瓶内均匀性一致,12个月稳定性检验结果的相对标准偏差为0.02%,说明宝藿苷Ι纯度标准物质是稳定的。对定值结果的不确定度进行了评价,研制的宝藿苷Ι纯度标准物质的定值结果和扩展不确定度分别为99.7%和0.3%(k=2)。  相似文献   

11.
基于氯离子加速的铜基芬顿反应构建了一种便捷、快速、无标记的比色分析方法并将其应用于多巴胺(DA)的快速检测。Cl^(-)可以加速Cu^(2+)催化过氧化氢(H_(2)O_(2))产生羟基自由基,进而氧化3,3′,5,5′-四甲基联苯胺(TMB)显色,而DA可以与Cu^(2+)配位,使反应速率减慢。基于此,可以利用检测液的颜色及TMB^(2+)在452 nm处吸光度的变化来实现对DA的检测。DA的浓度在0~10μmol/L及10~50μmol/L范围内与TMB^(2+)在452 nm处的吸光度呈线性相关,检出限为0.5μmol/L。本方法已用于实际样品的检测。  相似文献   

12.
建立了水产品中氨苯砜及其代谢产物N-乙酰氨苯砜残留量同时测定的高效液相色谱-紫外检测法(HPLC-UV)。样品经1%氨化乙腈提取,正己烷去脂,MCX阳离子固相萃取柱富集净化,氮吹浓缩,定容过膜后测定。以甲醇和水为流动相,ZORBAX SB-C_(18)色谱柱梯度洗脱分离,采用保留时间定性,外标法定量。在最佳检测条件下,目标化合物质量浓度在5~200 ng/mL范围内线性关系良好(R^(2)> 0.999),检出限(LOD)为10.0μg/kg,定量限(LOQ)为20.0μg/kg。以不同类型的水产品为空白基质,在20,50,100μg/kg加标水平下,氨苯砜的回收率为70.1%~81.7%,N-乙酰氨苯砜的回收率为84.2%~109.5%,相对标准偏差(RSD)均小于10%。该方法能够实现大批量水产品中氨苯砜及其代谢物残留量的检测。  相似文献   

13.
含顺二酚的分子,如糖类、糖苷和糖蛋白等,在糖组学、代谢组学和蛋白质组学等不同领域都有着至关重要的作用。但是这类样品分子通常存在于非常低丰度的环境中且与许多干扰化合物共存,给临床和生物学上的分离检测带来了巨大的困难。因此,开发建立对顺二醇类化合物简单高效的分离方法具有重要意义。分子印迹技术,是基于模拟生物体内抗原与抗体相互作用原理而发展起来的一种新兴技术,近年来因其特定的分子识别能力以及材料的稳定性和重复性而引起了广泛关注,也在顺二醇类化合物的分离方面得到了许多应用。本综述总结了在顺二醇类化合物的分子印迹方面的最新进展,并对其未来发展的方向和前景进行了讨论。  相似文献   

14.
采用L-半胱氨酸经一步湿化学法合成了稳定的铜纳米簇(CuCNs),优化了其制备条件,分别运用XPS和FTIR对其性能进行表征。CuCNs的荧光能被柠檬黄(LY)淬灭,推测其机理主要来自内滤效应。基于此,该荧光探针能选择检测LY,线性范围和检出限分别为3.33~60.0μmol/L和1.90μmol/L。该方法用于矿泉水和饮料中LY检测,回收率为95.5%~104.4%。  相似文献   

15.
通过水溶液法将Fe3O4@SiO2负载到丙烯酸(AA)-丙烯酰胺(AM)-对苯乙烯磺酸钠(SSS)三元共聚水凝胶上,制备了具有高吸附能力的磁性水凝胶P(AA/AM/SSS)/Fe3O4@SiO2。通过傅里叶变换红外光谱,X射线衍射光谱,拉曼光谱和比表面孔径分析表征了磁性水凝胶的微观结构。该磁性水凝胶平均孔径3.1 nm,属于介孔材料,且具有较好的热稳定性。吸附性能研究发现其对重金属离子Pb2+,Cu2+,Co2+,Cd2+和Ni2+均显示出较高的去除率,其中对Pb2+表现出优异的选择性,最大吸附量为497 mg/g。吸附动力学研究表明,吸附过程遵循拟二级动力学模型。再生实验发现该水凝胶经过7次吸附-解吸循环后,磁性水凝胶饱和吸附容量仍保持在265 mg/g。  相似文献   

16.
:The occurrence and development of breast cancer go through multiple processes,and the protein molecular information in its evolution is intricate and complex. The 4D-proteomics technique was used to investigate the tumor progression of MMTV-PyMT transgenic mice. The results of protein identification and differential expression analysis showed that a total of 5819 proteins were identified in 4D-proteomics analysis and 5667 proteins were quantifiable. Compared with 3-week-old tumors,a total of 270 differentially expressed proteins were found in the 5-week-old tumors,while 255 proteins in the 7-week-old tumors. We also detected 23 of proteins (such as,Srpk11 and Tinagl1)with gradual up-regulation and 35 of proteins (such as,Pdgfrb, Col1a2 and Col1a1)with gradual down-regulation during the tumor progression,including 3-,5-and 7-weeks. We also performed bioinformatics analysis,including subcellular localization,GO function analysis and pathway enrichment analysis. The results showed that the biological processes(immune regulation and lipid metabolism) and enrichment pathways (metabolic pathway)involved in differentially expressed proteins remained the same during the tumor progression,but some cellular components and molecular functions changed,such as,protein locations were extracellular region and membrane in 5-weeks-old tumors as well as cytoplasm in 7-weeks-old tumors. And important protein functions were protein binding functions in 5-weeks-old tumors as well as nucleotide binding in 7-weeks-old tumors. The acquired protein biomarkers and pathways could help with the accurate exploration of molecular mechanisms of tumor progression,screening of molecular targets of breast cancer,and evaluation of personalized treatment programs. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

17.
建立了高效液相色谱-串联质谱法测定食品接触材料及制品中8种二苯甲酮类物质迁移量的方法。样品经过食品模拟物浸泡后,水、4%乙酸、10%乙醇、20%乙醇、50%乙醇模拟物直接进样,95%乙醇模拟物用水按照1:4比例稀释后进样,橄榄油和异辛烷模拟物用甲醇-水混合溶液萃取后进样。采用C18柱分离,用甲醇-0.1%甲酸水溶液为流动相梯度洗脱,质谱采用正离子多反应监测(MRM)模式运行。本方法在8种食品模拟物中的定量限为0.01~0.20 mg/kg;在0.04~0.80 mg/kg, 0.2~2.0 mg/kg, 0.6~3.0 mg/kg线性范围内相关系数良好(R≥0.9958);加标实验结果显示相对标准偏差(RSD)为0.61%~7.8%。该方法可用于食品接触材料及制品中二苯甲酮类物质迁移量的测定。  相似文献   

18.
Nitrogen-doped carbon dots (N-CDs) were prepared by one-step hydrothermal synthesis with pomegranate seeds as the carbon source and urea as the nitrogen source. Observed by transmission electron microscopy (TEM), average particle size of N-CDs was 20 nm. Observed by atomic force microscopy (AFM), the thickness of N-CDs was 0. 6-1. 4 nm. Fourier transform infra-red (FT-IR) confirmed the presence of water-soluble functional groups such as amino groups on the surface of N-CDs. With the prepared N-CDs as the target fluorophore, Hg2 + can efficiently bind to the surface of N-CDs to form a complex, and achieve static quenching. The addition of tiopronin can bind the Hg2 + in the complex to make the Hg2 + detach from the surface of N-CDs and realize fluorescence recovery. The nano fluorescence switch constructed in this work is more accurate and sensitive than the traditional detection method. The optimum conditions were determined by optimizing the pH value, reaction time, the dosage of N-CDs and Hg2 +. The relative deviation (RSD) was 4. 7%, and the detection limit was 0. 2 μmol/L. The method was used to determine the content of tiopronin in human serum samples with the recoveries of 97. 2%-101. 3%. © 2022, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

19.
由N-乙酰(R)-四氢噻唑-2-硫酮-4-羧酸在三聚氯氰及三乙胺存在下与四氢噻唑-2-硫酮反应得到标题化合物,[α]^2^0~D +11.18°。用X射线衍射法测得其晶体结构,属单斜晶系,空间群为P2~1/c。晶体学数据:a=0.9959(4)nm,b=1.1469(4)nm,c=1.1108(3)nm,β=92.72(3)°,V=1.2673(8)nm^3,Z=4。分子中两个C=O基,两个C=S基团处于C(1)-N(1)-C(4)及C(6)-N(2)-C(7)键两侧呈反式。用PM3分子轨道方法研究了该化合物的电子结构,电荷和键序分布,得到该化合物前线轨道性质。  相似文献   

20.
由2-(1,2-亚乙二硫)亚甲基-3-羰基-5-芳基-4-戊烯酸与三苯基氢氧化锡反应,合成了九个标题化合物3。用X射线衍射法测定了3b的晶体结构。该晶体属三斜晶系,空间群P1,a=0.9074(2)nm,b=1.6809(3)nm,c=2.1834(4)nm,α=77.57(3)ⅲ,β=88.04(3)ⅲ,γ=89.47(3)ⅲ,V=3.2503nm^3,Z=2;R=0.0592。由锡氧原子间距离可推测,该晶体中羧酸根作为双齿配体与锡原子形成了分子内五配位结构。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号