首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The production and transportation of fluorescent light produced in wavelength-shifting fibers (WSFs) coupled to YAP scintillation crystal is simulated using the GEANT4 codes. An advantage of the wavelength-shifting fiber readout technique over a direct readout with a position-sensitive photo-sensor is the reduced requirement for position sensitive photomultiplier tube photocathode area. With this gamma-ray detector, the gamma camera is small and flexible and has larger effective field of view and low cost. Simulation results show that a) a mean 12 of photons per 59.5 keV gamma ray interaction is produced in the WSF located nearest to the incident gamma ray, and a spatial resolution of 3.6 mm FWHM is obtained, b) a mean 27 of photons per 140 keV gamma ray interaction is produced and a spatial resolution of 3.1 mm FWHM is obtained. Results demonstrate the feasibility of this concept of a compact gamma-ray detector based on wavelength-shifting fibers readout. However, since the very low photoelectron levels, it is very important to use a photon counting device with good single photo-electron response to readout the WSFs.  相似文献   

2.
祝杰  刘成  汪兆民 《光子学报》2006,35(10):1497-1500
基于波长位移光纤(WSF)耦合YAP晶体中的光子传输特性,用GEANT4软件包建立了一个蒙特卡罗模拟程序.对采用波长位移光纤耦合平板式YAP晶体的小型单管γ相机的性能进行了计算机模拟.采用波长位移光纤耦合光电倍增管光阴极面的读出方式,和晶体直接耦合光电倍增管光阴极面相比,在相同的晶体面积大小条件下,PSPMT光阴极面积可大大缩小,使费用降低.模拟结果表明:γ射线与晶体发生作用的地方所对应的光纤输出的平均光子数最少为15个,位置灵敏光电倍增管完全可以探测到.说明采用闪烁晶体-WSF-位置灵敏光电倍增管的读出方式是可行的;在用硅油耦合波长位移光纤和YAP晶体的情况下,获得的空间分辨率为1.28 mm(FWHM).模拟结果也说明了增加平均光子数对提高空间分辨率的重要性.  相似文献   

3.
新型微结构气体探测器,如气体电子倍增器(gas electron multiplier,GEM)等,具有非常好的位置分辨率潜力(σ100μm),但是需要匹配大规模高密度的读出电子学,给探测器的建设、造价、功耗、空间利用等带来极大压力.阻性阳极读出方法可以在保持较高位置分辨率的前提下,大幅节省电子学.基于厚膜电阻工艺,一种新的阻性单元阵列结构被成功开发和应用于三级级联GEM探测器的读出阳极.该阻性阳极包括6×6个6 mm×6 mm的基本阻性单元,仅需匹配49路读出电子学.~(55)Fe放射源(5.9 keV)和X光机(8 keV)实验的结果显示探测器的位置分辨率(σ)可好于80μm,位置非线性好于1.5%.同时,探测器还获得了很好的实物成像效果.探测器的优良性能表明这种阻性阳极读出方法适用于大面积二维成像气体探测器的读出,并可用于其他探测器的读出.  相似文献   

4.
本研究采用双层150 mm×150 mm闪烁条阵列定位宇宙线的入射和出射位置. 阵列信号光使用波移光纤吸收传输,在ICCD相机前插入前置像增强器,使信号光延迟大于200 ns, 使ICCD可以由外部高速触发信号控制,有效记录随机触发事例.该宇宙线定位系统可以同时多点密集测量 通用探测器测试平台的时间分辨和闪烁光的渡越时间.该新方法与传统时间分辨测量方法相比提高了30倍以上 的效率.实验结果显示:时间探测器的时间分辨好于200 ps,满足通用探测器测试平台的设计要求.  相似文献   

5.
A prototype of time-of-flight positron emission computed tomography(TOF-PET)has been developed for acquiring the coincident detection of 511 keV γ-rays produced from positron annihilation.It consists of two 80.5 mm×80.5 mm LYSO scintillator arrays(composed of 35 ×35 pixel finger crystals)with the position sensitive photomultiplier tubes R2487 as the readout.Each array is composed of 2 mm ×2 mm× 15 mm finger crystals and the average pixel pitch is 2.30 mm.The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction.The best spatial resolution(FWHM)of the prototype for the pairs of 511 keV γ-rays is 1.98 mm and 2.16 mm in the x and y directions,respectively,which are smaller than the average pixel pitch of 2.30 mm.  相似文献   

6.
由于受激元素所辐射的光子能量范围主要集中在100 keV~6 MeV之间,因此通过基于此能量范围的射线源模拟实验研究了采用锗酸铋(BGO)阵列相邻信号叠加实现能量高分辨率的新方法并分析比较了其性能。结果显示:对于较高能的光子,若仅使用单根BGO晶体产生的信号时不可能得到较好的能量分辨率;而当使用BGO阵列将该单晶体产生的信号与相邻晶体产生信号相加,则能谱质量会变得更佳。对于能量分辨率为90 keV的能量窗,通过模拟得到平均固有空间分辨率为3.938 mm (FWHM)。  相似文献   

7.
Jianjin Zhou 《中国物理 B》2022,31(5):50702-050702
In recent years, gas electron multiplier (GEM) neutron detectors have been developing towards high spatial resolution and high dynamic counting range. We propose a novel concept of an Al stopping layer to enable the detector to achieve sub-millimeter (sub-mm) spatial resolution. The neutron conversion layer is coated with the Al stopping layer to limit the emission angle of ions into the drift region. The short track projection of ions is obtained on the signal readout board, and the detector would get good spatial resolution. The spatial resolutions of the GEM neutron detector with the Al stopping layer are simulated and optimized based on Geant4GarfieldInterface. The spatial resolution of the detector is 0.76 mm and the thermal neutron detection efficiency is about 0.01% when the Al stopping layer is 3.0 μ m thick, the drift region is 2 mm thick, the strip pitch is 600 μ m, and the digital readout is employed. Thus, the GEM neutron detector with a simple detector structure and a fast readout mode is developed to obtain a high spatial resolution and high dynamic counting range. It could be used for the direct measurement of a high-flux neutron beam, such as Bragg transmission imaging, very small-angle scattering neutron detection and neutron beam diagnostic.  相似文献   

8.
介绍了一种基于THGEM的X射线光斑寻迹探测器,用于X射线单光子计量技术研究和测量,探测器有效面积200 mm×200 mm,采用128路基于ASIC和FPGA的高速读出电子学,探测器分为中间高分辨区和外围低分辨区两部分,两部分共用一套读出电子学。实验在中国计量科学研究院利用X光机产生的束线,测试光斑位置、光斑精细分布以及探测器的位置分辨。实验结果表明,探测器实现了同时对光斑寻迹和光斑的精细测量,探测器中间高分辨区x方向的位置分辨率为0.63 mm(FWHM),y方向位置分辨率为0.62mm(FWHM),探测器各项性能指标均达到了预期目标。This paper introduces the detector of X-ray spot tracing based on the THGEM. It is used for X ray single photon measurement technology research and measurement with an effective area of 200 mm×200 mm. The circuit board has 128 array of high speed readout electronics based on ASIC and FPGA. And it is divided into two parts:the middle area of high sensitive and the peripheral area of low sensitive. The two parts share a set of readout electronics. The experiment tests the position and the fine structure of the beam line produced by X ray machine in National Institute of Metrology. The results of the experimental show that the detector realizes both the spot tracing and the fine structure of the spot. The position resolution is 0.63 mm in x direction and 0.62 mm in y direction in high sensitive of the detector, which achieve the desired goal of preliminary design.  相似文献   

9.
Muon tomography is a promising method in the detection and imaging of high Z material. In general, considering the quality of track reconstruction in imaging, a detector of good position resolution, high efficiency and large area is required. This paper presents the design and study of a prototype of position sensitive MRPC with 0.15 mm narrow gas gap and 2.54 mm strip readout. Through a cosmic-ray experiment, the performance of MRPC module is carefully observed and each channel is calibrated. Through an X ray experiment with a narrow slit, the position resolution is studied. The results show that the time resolution of the module can reach 61ps and the spatial resolution can reach 0.36 mm.  相似文献   

10.
A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mmx200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector.  相似文献   

11.
激光驱动X射线单色背光照相系统优化设计   总被引:2,自引:0,他引:2  
 基于球面几何光学对激光驱动X射线单色背光照相系统的空间分辨力和成像效率等关键性能参数进行了理论推导,分析了当系统光学参数发生变化时,系统空间分辨力和成像效率互为制约的关系,由此提出了在保证能探测到图像的前提下,尽量提高系统空间分辨能力的优化设计方法。按照此方法具体设计了光子能量分别为5.07 keV和5.41 keV的两套背光照相系统,并用光线追迹模拟实验进行了验证。结果表明:设计的两套系统都能够在大约1 cm2的视场范围内,具有优于10 μm的空间分辨力。  相似文献   

12.
采用新型室温碲锌镉(CdZnTe)辐射探测器,通过厚针孔系统对137Cs高能662 keV伽玛射线辐射源进行成像探测,得到了能谱图和放射源图像。计算分析了高能射线穿透效应对空间分辨力的影响,并对不同偏压下得到的图像进行比较与讨论。实验表明,当放大倍率不大时(小于3),高能射线对准直器材料的穿透效应增大是限制图像空间分辨力的主要因素,探测器像素尺寸的大小对图像空间分辨力的影响并不明显。随偏置电压升高,探测器得到的图像会得到改善,但过大的偏压(大于1 000 V)会使晶体内部的电场不均匀性增大,降低信噪比从而降低图像品质。  相似文献   

13.
PET用新型深度编码探测器设计   总被引:1,自引:0,他引:1  
平行性问题或作用深度问题影响着正电子放射层析系统(PET)的成象分辨率。本文提出和评价了一种二阶深度编码探测器,这个探测器是由两层LSO晶体和位置灵敏型光电倍增管(PS-PMT)组成,上层的晶体相对于下层的晶体的位置在XY方向上都有半个晶体阵列单元的错位,因为每个晶体的输出光的重心位置分布在PS-PMT上不同的位置,所以通过计算其重心位置就可在象平面上区别开每个晶体。根据PET系统的应用要求,我们验证了探测器的性能。伽马射线垂直入射时,上层晶体阵列的固有空间分辨率为1.15mmFWHM,下层晶体列阵为1.34mm FWHM.钠伽马辐射源的511keV能量峰处的平均能量分辨率对于下层晶体为19.7%,上层为23.6%.通过类似的技术亦可实现3阶、4阶深度编码探测器。  相似文献   

14.
S S Desai  J N Joshi  A M Shaikh 《Pramana》2002,59(4):611-619
A 2-D multi-wire position sensitive detector for X-ray diffraction and small angle X-ray scattering studies is described. The detector has an active area of 100 mm × 100 mm and consists of an anode plane with 10 μm SS wires at 3 mm spacing and a pair of orthogonal cathode readout planes with 25 μm SS wires placed at 1.5 mm spacing. The position information is obtained using charge division method and recorded using a laboratory built data acquisition system. The resolution and gas gain was measured for 5.9 keV X-rays (55Fe-source) as a function of the anode wire voltage and gas pressure. It was observed that the proportional region of the PSD at 100 kPa pressure extended up to a high voltage value of around 1.5 kV and it shifted to high values up to 2 kV for gas pressure of 300 kPa. The energy resolution improved from 18% (FWHM) to 12% with increase in pressure. The spatial resolution of the PSD also showed improvement, with a value of 1.2 mm × 1.4 mm at 300 kPa gas pressure. A maximum gain of 5 × 104 is obtained.  相似文献   

15.
A three‐dimensional X‐ray detector for imaging 30–200 keV photons is described. It comprises a set of semi‐transparent structured scintillators, where each scintillator is a regular array of waveguides in silicon, and with pores filled with CsI. The performance of the detector is described theoretically and explored in detail through simulations. Based on available hardware, a spatial resolution of 1 µm is obtainable. The resolution of a single screen is shown to be determined only by the pitch, at least up to 100 keV. In comparison with conventional homogeneous screens, an improvement in efficiency by a factor of 5–15 is obtainable. The cross‐talk between screens in the three‐dimensional detector is shown to be negligible. The three‐dimensional concept enables ray‐tracing and super‐resolution algorithms to be applied.  相似文献   

16.
The first application of a pnCCD detector for X‐ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two‐dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse‐resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution ΔE/E? 10?2, a three‐dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so‐called single‐photon‐counting mode. A full dataset was evaluated taking into account all photons recorded within 105 detector frames at a readout rate of 200 Hz. By representing the data in reciprocal‐space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.  相似文献   

17.
In the Large High Altitude Air Shower Observatory (LHAASO) project, the one kilometer square extensive air shower array (KM2A) is the the largest detector array in terms of effective area. It consists of 5635 electromagnetic particle detectors (EDs) and 1221 muon detectors (MDs). Each ED is composed of 16 scintillator tiles readout by wavelength-shifting fibers that are bundled and attached by a 25 mm PMT. The design of the unit and its performances, such as photoelectron yield, time resolution and uniformity, are discussed in detail. An assembling scheme for the whole ED is established to guarantee the uniformity throughout all 16 tiles in a single ED and all EDs in mass production.  相似文献   

18.
The implementation of a laser pump/X‐ray probe scheme for performing picosecond‐resolution X‐ray diffraction at the 1W2B wiggler beamline at Beijing Synchrotron Radiation Facility is reported. With the hybrid fill pattern in top‐up mode, a pixel array X‐ray detector was optimized to gate out the signal from the singlet bunch with interval 85 ns from the bunch train. The singlet pulse intensity is ~2.5 × 106 photons pulse?1 at 10 keV. The laser pulse is synchronized to this singlet bunch at a 1 kHz repetition rate. A polycapillary X‐ray lens was used for secondary focusing to obtain a 72 µm (FWHM) X‐ray spot. Transient photo‐induced strain in BiFeO3 film was observed at a ~150 ps time resolution for demonstration.  相似文献   

19.
席发元  宋凤军 《强激光与粒子束》2018,30(9):096006-1-096006-5
实验采用并联方法制备了叠层(双层)碲锌镉探测器,并利用241Am@59.54 keV和57Co@122 keV γ射线源测试了其γ能谱特性。相比单层探测器,对于较高能量的57Co@122 keV γ射线,叠层碲锌镉探测器表现出较高的探测效率和光峰值效率,较好地改善了康普顿连续统一体。叠层CZT探测器较之单层探测器,能谱分辨率发生轻微恶化。实验初步表明,通过并联叠加方法制备叠层碲锌镉探测器是可行的,并可推断制备更大厚度的叠层探测器将有利于中高能γ射线能谱测量。  相似文献   

20.
中子小角散射探测器是小角散射(SANS)谱仪的关键设备之一,探测器要求有足够大的探测面积、较高的探测效率及较好的空间分辨率,能够在真空腔中稳定地工作并可在腔体内前后移动。综合考虑,SANS探测器采用120只8 mm直径位置灵敏3He管,组成有效面积1 000 mm(X)×1 020 mm(Y)的二维探测器阵列。探测器阵列分为10个模块,每一个模块功能完全独立,包括12只3He管及其对应的读出电子学和数据获取系统。读出电子学位于探测器背面的回字形密闭腔体内,由CSNS电子学组自主研发。SANS探测器从设计、选型、样机、调试到安装历时三年,中子束流实验结果显示探测器探测效率大于50%(@2Å),空间分辨率好于10 mm(FWHM),完全达到设计要求,目前正在中国散裂中子源小角散射谱仪运行使用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏