首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
  国内免费   5篇
数学   2篇
物理学   9篇
  2021年   1篇
  2019年   1篇
  2018年   1篇
  2015年   1篇
  2014年   2篇
  2012年   3篇
  2011年   1篇
  1994年   1篇
排序方式: 共有11条查询结果,搜索用时 31 毫秒
1.
教育部印发的《关于全面深化课程改革落实立德树人根本任务的意见》提到:数学核心素养是指学生应具备的,能够适应终身发展和社会发展需要的必备品质和关键能力。小学阶段该怎样培养学生的数学核心素养?我认为,选取适合的内容,采用有效的教学方法是关键。  相似文献   
2.
In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, which is very suitable for application in neutron detection. In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is achieved from 720 V to 770 V, with a plateau slope of 2.4%/100 V, and an excellent energy resolution of about 22% is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.  相似文献   
3.
介绍了一种基于THGEM的X射线光斑寻迹探测器,用于X射线单光子计量技术研究和测量,探测器有效面积200 mm×200 mm,采用128路基于ASIC和FPGA的高速读出电子学,探测器分为中间高分辨区和外围低分辨区两部分,两部分共用一套读出电子学。实验在中国计量科学研究院利用X光机产生的束线,测试光斑位置、光斑精细分布以及探测器的位置分辨。实验结果表明,探测器实现了同时对光斑寻迹和光斑的精细测量,探测器中间高分辨区x方向的位置分辨率为0.63 mm(FWHM),y方向位置分辨率为0.62mm(FWHM),探测器各项性能指标均达到了预期目标。This paper introduces the detector of X-ray spot tracing based on the THGEM. It is used for X ray single photon measurement technology research and measurement with an effective area of 200 mm×200 mm. The circuit board has 128 array of high speed readout electronics based on ASIC and FPGA. And it is divided into two parts:the middle area of high sensitive and the peripheral area of low sensitive. The two parts share a set of readout electronics. The experiment tests the position and the fine structure of the beam line produced by X ray machine in National Institute of Metrology. The results of the experimental show that the detector realizes both the spot tracing and the fine structure of the spot. The position resolution is 0.63 mm in x direction and 0.62 mm in y direction in high sensitive of the detector, which achieve the desired goal of preliminary design.  相似文献   
4.
In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, which is very suitable for application in neutron detection. In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is achieved from 720 V to 770 V, with a plateau slope of 2.4%/100 V, and an excellent energy resolution of about 22% is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.  相似文献   
5.
椭圆     
椭圆武汉市职工医学院许虹【基本概念】椭圆是平面内与两个定点F1、F2的距离的和等于常数(大于F1F2)的点的轨迹,这两个定点叫做椭圆的焦点,它们之间的距离叫做椭圆的焦距,椭圆与两坐标轴的交点叫做椭圆的顶点,在同一坐标轴上的两个交点之间的距离分别叫做椭...  相似文献   
6.
China Spallation Neutron Source (CSNS), one project of the 12th Five-Year-Plan scheme of China, is under construction in Guangdong province. Three neutron spectrometers will be installed during the first phase of the project, and two-dimensional position sensitive thermal neutron detectors are required. Before the construction of the neutron detectors, a prototype of a two-dimensional 200 mm×200 mm Multi-wire Proportional Chamber (MWPC) with Ar/CO2 (90/10) flowing gas has been constructed. In 2009, the prototype was tested with the 55Fe X-ray using part of the electronics, and performed well.  相似文献   
7.
Neutron beam monitor based on a boron-coated GEM   总被引:1,自引:0,他引:1  
A new thermal neutron beam monitor with a Gas Electron Multiplier (GEM) is developed to meet the needs of the next generation of neutron facilities. A prototype chamber has been constructed with two 100 mm×100 mm GEM foils. Enriched boron-10 is coated on one surface of the aluminum cathode plate as the neutron convertor. 96 channel pads with an area of 8 mm×8 mm each are used for fast signal readout. In order to study the basic characteristics of a boron-coated GEM, several irradiation tests were carried out with α source 239Pu and neutron source 241Am(Be). The signal induced by the neutron source has a high signal-to-noise ratio. A clear image obtained from α source 239Pu is presented, which shows that the neutron beam monitor based on a boron-coated GEM has a good two-dimensional imaging ability.  相似文献   
8.
中子小角散射探测器是小角散射(SANS)谱仪的关键设备之一,探测器要求有足够大的探测面积、较高的探测效率及较好的空间分辨率,能够在真空腔中稳定地工作并可在腔体内前后移动。综合考虑,SANS探测器采用120只8 mm直径位置灵敏3He管,组成有效面积1 000 mm(X)×1 020 mm(Y)的二维探测器阵列。探测器阵列分为10个模块,每一个模块功能完全独立,包括12只3He管及其对应的读出电子学和数据获取系统。读出电子学位于探测器背面的回字形密闭腔体内,由CSNS电子学组自主研发。SANS探测器从设计、选型、样机、调试到安装历时三年,中子束流实验结果显示探测器探测效率大于50%(@2Å),空间分辨率好于10 mm(FWHM),完全达到设计要求,目前正在中国散裂中子源小角散射谱仪运行使用。  相似文献   
9.
A new thermal neutron detector with a domestically produced THGEM (Thick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for neutron detection. A detector prototype has been developed and the preliminary experimental tests are presented, including the performance of the Au-coated THGEM working in Ar/CO2 gas mixtures and the neutron imaging test with 252Cf source, which can provide the reference for experimental data for research in the future.  相似文献   
10.
The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号