首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
  国内免费   8篇
物理学   11篇
  2014年   2篇
  2012年   2篇
  2011年   4篇
  2008年   1篇
  2003年   1篇
  2002年   1篇
排序方式: 共有11条查询结果,搜索用时 31 毫秒
1.
The THGEM detector without and with a CsI has been tested successfully. The optimal parameters of THGEM have been determined from eight samples. The UV photoelectric effect of the CsI photocathode is observed. The changing tendency related to the extraction efficiency (εextr) versus the extraction electric field is measured, and several electric fields influencing the anode current are adjusted to adapt to the THGEM detector with a reflective CsI photocathode.  相似文献   
2.
In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, which is very suitable for application in neutron detection. In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is achieved from 720 V to 770 V, with a plateau slope of 2.4%/100 V, and an excellent energy resolution of about 22% is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.  相似文献   
3.
In this paper, the performance of a type of domestic THGEM (THick Gaseous Electron Multiplier) working in Ar/CO2 mixtures is reported in detail. This kind of single THGEM can provide a gain range from 100 to 1000, which is very suitable for application in neutron detection. In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector, the counting rate plateau, the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields. For the Ar/CO2(90%/10%) gas mixture, a wide counting rate plateau is achieved from 720 V to 770 V, with a plateau slope of 2.4%/100 V, and an excellent energy resolution of about 22% is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.  相似文献   
4.
The J/ψ hadronic decays provide good laboratory to search for the hybrid states with exotic quantum numbers. A full Partial Wave Analysis (PWA) is performed to the generated Monte Carlo J/ψ→ρηπ data, based on the design of BESⅢ detector, to study the sensitivity of searching for a possible exotic state at BESⅢ.  相似文献   
5.
THGEM with resistive Kapton electrodes (RETGEM) has been developed to make the THGEM more tolerant to discharges. At higher gains with resistive electrodes, serious discharges may travel to the streamer mode, in contrast to violent sparks in conventional GEMs. These streamers are mild and less dangerous to the detector and the front-end electronics. RETGEM looks very promising, and its basic properties are being studied. Recently we developed and tested the THGEM with electrodes using 20 um thick resistive kapton foils. The new RETGEM performs at a lower discharge current, has a lower discharge probability, and has a good energy resolution of 27% and a high effective gas gain and long-term stability.  相似文献   
6.
Silicon photomultipliers (SiPMs) are a new generation of semiconductor-based photon counting devices with the merits of low weight, low power consumption and low voltage operation, promising to meet the needs of space particle physics experiments. In this paper, comparative studies of SiPMs and traditional vacuum photomultiplier tubes (PMTs) have been performed regarding the basic properties of dark currents, dark counts and excess noise factors. The intrinsic optical crosstalk effect of SiPMs was evaluated.  相似文献   
7.
A micro-pattern gas detector named leak microstructure (LM) has been studied. A new chemical electrolytic technique is introduced to make perfect shaped LM needles with very sharp tips, and this method may be developed to make LM array detectors in batches. The experimental results are presented for both a single needle LM detector and a small LM array detector. The gas gain is up to 105 by calculation from the waveform. Good gain stability and uniformity are achieved. The light emission from the needle tip is also measured in Ar/CF4(95/5) gas mixture. The result shows a promising application for imaging.  相似文献   
8.
The gas gain and energy resolution of single and double THGEM detectors (5 cm×5 cm effective area) with mini-rims (rim less than 10 μm) were studied. The maximum gain was found to reach 5×103 and 2×105 for single and double THGEMs respectively, while the energy resolution for 5.9 keV X-rays varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses. Different combinations were also investigated of noble gases (argon, neon) mixed with a quantity of other gases (isobutane, methane) at atmospheric pressure.  相似文献   
9.
The BEPCⅡ Luminosity Monitor (BLM) monitors relative luminosity per bunch. The counting rates of gamma photons, which are proportional to the luminosities from the BLM at the center of mass system energy of the ψ(3770) resonance, are obtained with a statistical error of 0.01% and a systematic error of 4.1%. Absolute luminosities are also determined by the BESⅢ End-cap Electro-Magnetic Calorimeter (EEMC) using Bhabha events with a statistical error of 2.3% and a systematic error of 3.5%. The calibration constant between the luminosities obtained with the EEMC and the counting rates of the BLM are found to be 0.84±0.03 (×1026 cm-2·count-1). With the calibration constant, the counting rates of the BLM can be scaled up to absolute luminosities.  相似文献   
10.
依据大学物理实验教学管理的发展需要 ,利用计算机数据库开发技术和网络技术 ,建立实验教学管理信息系统 ,包括系统结构模型、主要功能模块和工作流程的设计。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号