首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
HIRFL—CSR实验环电子冷却装置调试   总被引:1,自引:0,他引:1  
HIRFL-CSR实验环电子冷却装置采用了能够产生空心电子束的电子枪。弯曲螺线管内采用了静电偏转电极,冷却段采用了独立的高精度螺线管串联产生纵向磁场的设计。测量了沿离子束运动方向冷却段磁场分布及磁场平行度、电子枪和收集器性能、300kV高压电源相关参数。结果表明,此装置达到了预期的设计目标。: In CSRe electron cooling device, a special electron gun which can produce variable profile electron beam with different size and density distribution was adopted for decreasing ion losses. Electrostatic bending device was used for reducing electron beam losses and improving vacuum condition. The instability of the electron beam is suppressed because the secondary electrons from collector would come back to the collector in the same orbit finally. Longitudinal magnetic field with parallelism better than 10-4 was achieved by adopting of independent high precise solenoid coils at cooling section. In this case, the r.m.s deviations of the transverse magnetic field at cooling section in horizontal and vertical direction are 3.298×10-5 and 2.458×10-5 respectively. The characters of the gun and collector were investigated. The results were presented and indicate that it achieves the design purpose very well.  相似文献   

2.

The six species heavy ion beam was accumulated with the help of electron cooling in the main ring of Cooler Storage Ring of Heavy Ion Research Facility in Lanzhou (HIRFL-CSR). The ion beam accumulation dependence on the parameters of cooler was investigated experimentally. The 400 MeV/u 12C6+ and 200 MeV/u 129Xe54+ were stored and cooled in the experimental ring CSRe, and the cooling force was measured in different conditions.

  相似文献   

3.
A new generation electron cooler has started operation in the heavy ion synchrotron CSRm which is used to increase the intensity of heavy ions. Transverse cooling of the ion beam after horizontal multi-turn injection allows beam accumulation at the injection energy. After optimization of the accumulation process an intensity increase in a synchrotron pulse by more than one order of magnitude has been achieved. In given accumulation time interval of 10 seconds, 108 particles have been accumulated and accelerated to the final energy. The momentum spread after accumulation and acceleration in the 10-4 range has been demonstrated in six species of ion beams. Primary measurements of accumulation process varying with electron energy, electron beam current, electron beam profile, expansion factor and injection interval have been performed. The lifetimes of ion beams in the presence of electron beams were roughly measured with the help of DCCT signal.  相似文献   

4.
Electron cooling is used for damping both transverse and longitudinal oscillations of heavy particle. The cooling of bunch ion beam (with RF voltage on) is important part of experiments with inner target, ion collision system, stacking and RF manipulation. The short length of an ion bunch increases the peak luminosity, gives a start-time point for using of the time-of-flight methods and obtains a short extraction beam pulse. This article describes the review of last experiments with electron cooling carried out on the CSRm, CSRe (China) and COSY (Germany) storage rings. The accumulated experience may be used for the project of electron cooler on 2.5 MeV (NICA) and 0.5 MeV HIAF for obtaining high luminosity, depressing beam-beam effects and RF manipulation.  相似文献   

5.
兰州重离子加速器冷却储存环中电子冷却性能   总被引:1,自引:1,他引:0       下载免费PDF全文
为了在兰州重离子加速器冷却储存环(HIRFL-CSR)上开展一维离子束序化的研究,在CSR主环上,对6.39 MeV/u的58Ni19+离子束进行了冷却累积实验。测量了离子束与电子束之间不同的水平、垂直夹角以及不同电子束剖面的情况下,束流累积及束流寿命变化情况;重点研究了离子束衰减过程中动量分散随离子数的变化规律,拟合计算得到了动量分散随离子数按照幂函数衰减的指数;在给定离子数的情况下,动量分散随夹角、电子束剖面的依赖关系,为下一步在CSR上获得纵向一维有序化离子束的研究做准备。在实验中观测到在较大的夹角情况下,离子束出现纵向振荡和中心频率移动。  相似文献   

6.
HIRFL-CSR, a new heavy ion cooler-storage-ring system at IMP, had been in commissioning since the beginning of 2006. In the two years of 2006 and 2007 the CSR commissioning was finished, including the stripping injection (STI), electron-cooling with hollow electron beam, C-beam stacking with the combination of STI and e-cooling, the wide energy-range synchrotron ramping from 7 MeV/u to 1000 MeV/u by changing the RF harmonic-number at mid-energy, the multiple multi-turn injection (MMI), the beam accumulation with MMI and e-cooling for heavy-ion beams of Ar, Kr and Xe, the fast extraction from CSRm and single-turn injection to CSRe, beam stacking in CSRe and the RIBs mass-spectrometer test with the isochronous mode in CSRe by using the time-of-flight method.  相似文献   

7.
研究了CSRe电子冷却模式下使用线性质量刻度时, 空间电荷效应对测量精度的影响、 CSRe上测量190Ir质量的实验可行性以及估算了电子冷却模式下, 使用非线性刻度法所能达到的测量精度。 理论上的分析表明, CSRe在束流和二极铁磁场稳定的理想情况下, 如果电子冷却对同种离子束的冷却效果能达到δp/p=10-6量级, 采用非线性刻度的方法, 能够对像190Ir这样的重离子达到σ(m)/m≈10-8的测量精度。 Nuclear mass measurement by electron cooling mode in CSRe is discussed, mainly in three related aspects: the systematic error caused by the space charge effect in the case of linear mass calibration; the possibility of mass measurement of 190 Ir in CSRe; the estimation of the attainable precision in the case of non linear mass calibration. Theoretic analysis of the attainable precision shows that a precision of σ(m)/m≈10-8 can be achieved if the momentum spread of each kind of ions can be reduced to 10-6 in CSRe.  相似文献   

8.
HIRFL-CSR主环电子冷却模拟计算   总被引:2,自引:0,他引:2  
16O8+为例,用电子冷却模拟程序计算了冷却时间随离子能量、初始发射度、初始动量分散、离子流强以及离子电荷态的变化规律,研究了储存环在冷却段的β函数和色散函数对冷却时间的影响.  相似文献   

9.
Commissioning of electron cooling in CSRm   总被引:1,自引:0,他引:1  
A new generation electron cooler has started operation in the heavy ion synchrotron CSRm which is used to increase the intensity of heavy ions. Transverse cooling of the ion beam after horizontal multi-turn injection allows beam accumulation at the injection energy. After optimization of the accumulation process an intensity increase in a synchrotron pulse by more than one order of magnitude has been achieved. In given accumulation time interval of 10 seconds, 108 particles have been accumulated and accelerated to the final energy. The momentum spread after accumulation and acceleration in the 10-4 range has been demonstrated in six species of ion beams. Primary measurements of accumulation process varying with electron energy, electron beam current, electron beam profile, expansion factor and injection interval have been performed. The lifetimes of ion beams in the presence of electron beams were roughly measured with the help of DCCT signal.  相似文献   

10.
Laser cooling of Li-like C~(3+)and O~(4+)relativistic heavy ion beams is planned at the experimental Cooler Storage Ring(CSRe). Recently, a preparatory experiment to test important prerequisites for laser cooling of relativistic~(12)C~(3+)ion beams using a pulsed laser system has been performed at the CSRe. Unfortunately, the interaction between the ions and the pulsed laser cannot be detected. In order to study the laser cooling process and find the optimized parameters for future laser cooling experiments, a multi-particle tracking method has been developed to simulate the detailed longitudinal dynamics of laser-cooled ion beams at the CSRe. Simulations of laser cooling of the~(12)C~(3+)ion beams by scanning the frequency of the RF-buncher or continuous wave(CW) laser wavelength have been performed. The simulation results indicate that ion beams with a large momentum spread could be laser-cooled by the combination of only one CW laser and the RF-buncher, and show the requirements of a successful laser cooling experiment. The optimized parameters for scanning the RF-buncher frequency or laser frequency have been obtained.Furthermore, the heating effects have been estimated for laser cooling at the CSRe. The Schottky noise spectra of longitudinally modulated and laser-cooled ion beams have been simulated to fully explain and anticipate the experimental results. The combination of Schottky spectra from the highly sensitive resonant Schottky pick-up and the simulation methods developed in this paper will be helpful to investigate the longitudinal dynamics of RF-bunched and ultra-cold ion beams in the upcoming laser cooling experiments at the CSRe.  相似文献   

11.
考虑储存环内离子的横向振荡和纵向振荡的运动特性,模拟了HIRFL-CSR内重离子束的电子冷却过程.给出了离子束的横向发射度和纵向动量散度随时间连续变化的图象,由此分析了电子束的空间电荷效应,冷却段色散函数和横向电子束温度对冷却过程快慢的影响.  相似文献   

12.
Particles in a storage ring oscillate in the longitudinal and transverse dimensions.Therefore,the signal that beam has generated can be analyzed in the frequency domain to extract many beam parameters,such as tune,momentum spread,emittance and their evolution with time and so on.In this paper,the transverse spectrum in HIRFI-CSR was simulated and analyzed under different conditions,including electron cooling,hollow electron beam,solenoid effect,the tune shift caused by power supply ripple and the misalignment between ion and electron beams.The result of the simulation shows that the longitudinal magnetic field of the electron cooling device should be compensated by a "compensation solenoid",and the power supply ripple must be controlled,otherwise the accumulation would be affected and the beam would be lost.  相似文献   

13.
实验研究了HIRFL-CSRm中电子冷却装置对C6+,Ar15+两种束流寿命的影响。首先,通过对比实验的测量确定电子冷却可以有效提高束流寿命;其次,探究了电子冷却装置中的各项参数(主要是电子束密度分布、流强、能量、绝热展开因子)是如何影响束流寿命的,通过改变电子束参数,测量束流寿命的变化趋势和规律,并且结合电子冷却相关理论对实验结果给予解释,最终通过实验优化和确定最佳的冷却装置参数,使束流在HIRFL-CSRm上获得了较高的寿命,从而提高HIRFL-CSRm束流累积过程中的流强增益。  相似文献   

14.
HIRFL-CSR电子冷却束流位置测量系统   总被引:1,自引:0,他引:1  
高效率的电子冷却过程, 要求电子束与离子束位置平行且重叠。 为了同时测量电子束与离子束的位置, 在HIRFL CSR电子冷却装置上研发了以容性圆筒形极板为感应电极的束流位置探测系统。 系统测量束流通过探针时产生的脉冲感应信号, 并进行傅里叶变换得到频谱信号, 分析4个不同电极上频谱信号强度获取束流的位置信息。 测量结果表明, 该束流位置探测系统测量准确, 为定量研究储存环离子累积和电子冷却过程与两种束流相对位置及角度的依赖关系提供了条件。 The efficient electron cooling requires that the ion beam and electron beam are parallel and overlapped. In order to measure the positions of ion beam and electron beam simultaneously, a beam position monitor system is developed for the HIRFL-CSR electron cooler device, which probe consists of four capacitive cylinder linear cut poles. One can get the both beam positions from the picking up signals of four poles by using Fourier transform(FFT) method. The measurement results show that the beam position monitor system is accurate. This system is suitable for investigating the relation between electron cooling processing and the angle of ion beam and electron beam.  相似文献   

15.
 在HIRFL-CSR实验环电子冷却装置上采用了独立的高精度螺线管串联产生纵向磁场的设计,获得很高的冷却段磁场平行度。使用霍尔片测量磁场的分布,使用磁针测磁方法测量冷却段磁场的磁轴偏角,并根据测量及计算结果对单个线圈磁轴进行微调。测量及调试结果表明,在施加电流为额定电流的一半时,冷却段磁感应强度为0.078 T,剩余磁场小于2×10-4 T,磁场不平行度小于1×10-4,达到了预期的设计目标。  相似文献   

16.
HIRFL-CSR电子冷却系统空心电子束性能研究   总被引:1,自引:1,他引:0       下载免费PDF全文
 电子冷却系统中冷却力的大小与电子束的温度密切相关。由于强流电子束自身产生的空间电荷场,使得电子束的速度离散,增加了电子束温度,降低了冷却效率。为了减小空间电荷效应,HIRFL CSR的电子冷却系统将首次采用空心电子束对储存环中的重离子束流进行冷却。通过分析实心电子束和空心电子束的空间电荷场,研究了其对电子束速度和温度的影响。  相似文献   

17.
The change in the short-range order created by ion milling in the near surface region of InP single crystals was investigated by primary beam diffraction modulated electron emission (PDMEE). The very early stage of the damage creation by low energy (0.6–1 keV) Ar ions in normal and oblique incidence was studied. A simple model based on the weighted combination of perfectly crystalline and completely amorphous regions was used to model the experimental results. Evidence of a subsurface nucleation of the amorphization process was found. We also found that the total sputtering yield is markedly dependent on the ion dose, being on the undamaged surface much larger than its steady state value. Low energy electron diffraction (LEED) measurements were also performed to correlate long-range and short-range order removal by ion bombardment. Finally, the ion damage on the GaAs and InP surfaces was comparatively discussed.  相似文献   

18.
使用电子枪对ECR(Electron Cyclotron Resonance)等离子体注入外电子束是继铝衬弧腔、偏压盘之后,对等离子体电子的额外补充的又一种手段,通过向弧腔中注入一定能量与流强的电子束,以期提高引出束流的流强与电荷态。但由于该方法可控参数繁多,经验积累与报道资料都很少,且设计与操作远不如偏压盘等手段简便,故一直未能得到深入研究。通过以三维仿真软件CST粒子工作室对注入到弧腔电子束的运动轨迹的模拟结果为依据、以18 GHz ECR蒸发冷却源为平台,进行了ECR等离子体注入电子束的实验,结果表明:在一定实验条件下,当注入电子束能量超过1 800 eV时,会产生一种引出的离子束流的激增现象。在这个现象中,脉冲与直流的流强均比未注入电子时要高,束流电荷态向高价方向移动,且可通过控制实验条件来控制这种现象。最后对于这种电子并未通过共振面,却能起到提高电荷态与流强的作用进行了分析与讨论,并认为该现象在改善直流束与脉冲束性能的方面都有着积极的意义。The injection of the electron beam into the ECR (Electron Cyclotron Resonance)plasma by electron gun is a new method for the additional supplementary of the plasma electron, following the aluminum chamber wall and the bias plate, we are expecting for the higher current and charge state of the ion beam with it. However, because of the controllable parameter's variety, the lack of the accumulation of experience and data, and the shortage of convenience in designing and experimental practicing compared by biased disk and other means,it has always not been intensively studied. In this article, we take the 18 GHz ECR Ion Source using evaporative cooling technique as experimental platform, do the experiment of injecting electron into ECR plasma base on the simulation result of the electron beam's path in ECR's chamber by the 3D simulation software CST the particle studio. It shows that a pulsing leap of the current of the extracting ion beam appears when the injecting electron's energy is above 1 800 eV. In the mean time, the top of the pulse and the average current of the ion beam rises, the ionization state moves to a higher level. This phenomenon can be turned on and off by controlling the experimental condition. At the last part of the article, we discuss this improvement of the current and charge state of the ion beam despite of the position's missing between the injection of electron beam and the resonance surface, and hold the opinion that this phenomenon is positive to both pulsed and direct beam.  相似文献   

19.
汤明杰  杨涓  金逸舟  罗立涛  冯冰冰 《物理学报》2015,64(21):215202-215202
微型电子回旋共振(ECR)离子推力器可满足微小航天器空间探测的推进需求. 为此, 本文开展直径20 mm的微型ECR离子源结构优化实验研究. 根据放电室内静磁场和ECR谐振区的分布特点, 研究不同微波耦合输入位置对离子源性能的影响, 结果表明环形天线处在高于ECR谐振强度的强磁场区域时, 微波与等离子体实现无损耦合, 电子共振加热效果显著, 引出离子束流较大. 根据放电室电磁截止特性, 结合微波电场计算, 研究放电容积对离子源性能的影响, 实验表明过长或过短的腔体长度会导致引出离子束流下降甚至等离子体熄灭. 经优化后离子源性能测试表明, 在入射微波功率2.1 W、氩气流量14.9 μg/s下, 可引出离子束流5.4 mA, 气体放电损耗和利用率分别为389 W/A和15%.  相似文献   

20.
In order to extend the dielectronic recombination (DR) experiments from the main cooler storage ring CSRm with intermediate charge state ions to the experimental cooler storage ring CSRe with highly charged ions and even radioactive ions, a test electron-ion recombination experiment of B-like Ar13+ ions was performed with a section of the new electron beam energy detuning system, which will be installed at the CSRe. We present the measured and also the calculated DR spectra for the ∆n = 0 resonances from 0 to 3 eV. The experimental results agree very well with the previous DR experimental data from CRYRING, and the energy resolution reached 30 meV full width at half maximum. This test experiment demonstrates that the reliability and stability of the newly developed electron beam energy detuning system are satisfactory for the upcoming DR experiments at the CSRe. However, we found large discrepancies between the experimental result and the calculation in both resonance positions and the intensities of the recombination spectrum below 0.7 eV, which indicate that precise calculation of the DR spectrum of multielectron ions is still a challenge.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号