1.
Commissioning of electron cooling in CSRe   总被引:1,自引:0,他引:1  
The 400 MeV/u 12C6+ ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe.The momentum cooling time was estimated near 15 s.The cooling force was measured in the cases of difierent electron beam profiles,and the difierent angles between the ion beam and electron beam.The lifetime of the ion beam in CSRe was over 80 h.The dispersion in the cooling section was confirmed as positive close to zero.The beam sizes before cooling and after cooling were measured by the moving screen.The beam diameter after cooling was about 1 mm.The bunch length was measured with the help of the signals from the beam position monitor.The difiusion was studied in the absence of the electron beam.  相似文献   
2.
HIRFL—CSR实验环电子冷却装置调试   总被引:1,自引:0,他引:1  
HIRFL-CSR实验环电子冷却装置采用了能够产生空心电子束的电子枪。弯曲螺线管内采用了静电偏转电极,冷却段采用了独立的高精度螺线管串联产生纵向磁场的设计。测量了沿离子束运动方向冷却段磁场分布及磁场平行度、电子枪和收集器性能、300kV高压电源相关参数。结果表明,此装置达到了预期的设计目标。: In CSRe electron cooling device, a special electron gun which can produce variable profile electron beam with different size and density distribution was adopted for decreasing ion losses. Electrostatic bending device was used for reducing electron beam losses and improving vacuum condition. The instability of the electron beam is suppressed because the secondary electrons from collector would come back to the collector in the same orbit finally. Longitudinal magnetic field with parallelism better than 10-4 was achieved by adopting of independent high precise solenoid coils at cooling section. In this case, the r.m.s deviations of the transverse magnetic field at cooling section in horizontal and vertical direction are 3.298×10-5 and 2.458×10-5 respectively. The characters of the gun and collector were investigated. The results were presented and indicate that it achieves the design purpose very well.  相似文献   
3.
强流重离子加速器装置(HIAF)的增强器(BRing)二极铁电源样机采用多模块串并联的全储能快循环脉冲电源实现方案,电源功率达到MW级。由于电源规模庞大和功率巨大,为了在运行中迅速保护电源设备,设计并实现了一套双冗余的基于可编程逻辑控制器(PLC)、模块故障联锁板和现场可编程门阵列(FPGA)的模块故障联锁保护系统,利用硬件和软件同时对电源功率单元模块实施故障检测、故障传递和故障保护。设计完成后分别从电源联锁环路的响应时间、核心控制板故障引发电源环路联锁的总时间和设备故障响应等三个方面进行测试,测试结果表明,在电源发生故障时,模块故障联锁保护系统满足电源样机对实时性和可靠性的要求,达到设计目标。  相似文献   
4.
设计了一台用于兰州重离子加速器HIRFL-CSR的六极磁铁数字电源, 该电源以H桥变换器为主拓扑结构电路, 采用Cyclone II FPGA作为核心硬件, 以Verilog语言实现了全数字化的PI调节算法。 电源输出电流达到了340 A, 直流电流稳定度达到了3.14×10-5, 达到了1×10-4的设计指标。One digital power supply was designed for the sextupole magnets of Cooler Storage Ring of the Heavy Ion Research Facility in Lanzhou (HIRFL CSR). It adopts H Bridge convertor as the main topology circuit and Cyclone II FPGA as the main hardware, and has realized fully digitized PI regulation arithmetic by Verilog language. The peak current of the power supply reaches 340 A and the stability approaches 3.14×10-5. Finally the power supply has achieved the designed specification of 1×10-4.  相似文献   
5.
主环二极铁电源是兰州重离子加速器冷却储存环(HIRFL-CSR)工程的关键设备和指标要求最高的一台电源,采用了独特的拓扑和控制策略。为满足峰值功率3.15MW(3kA,1.45kV)的输出能力和快脉冲要求,采用了晶闸管整流并联脉宽调制补偿单元的主电路拓扑结构和特殊的控制方式,这套综合方案确保电源满足了全部技术指标。本文介绍了该拓扑结构的原理和优势,讨论了为满足±2×10-4的跟踪误差的要求而采用的控制拓扑和双基准给定的原理,并简介了调试过程和近年来的运行和改进情况。  相似文献   
6.
 在HIRFL-CSR实验环电子冷却装置上采用了独立的高精度螺线管串联产生纵向磁场的设计,获得很高的冷却段磁场平行度。使用霍尔片测量磁场的分布,使用磁针测磁方法测量冷却段磁场的磁轴偏角,并根据测量及计算结果对单个线圈磁轴进行微调。测量及调试结果表明,在施加电流为额定电流的一半时,冷却段磁感应强度为0.078 T,剩余磁场小于2×10-4 T,磁场不平行度小于1×10-4,达到了预期的设计目标。  相似文献   
7.
欧恒恒  燕宏斌  张帅  周宁  赵鑫  原振栋  吴凤军 《强激光与粒子束》2022,34(6):064003-1-064003-6
为满足分离扇回旋加速器(SSC)对于磁场精度的需求,需对其主场电源进行改造。提出开关电源与线性电源相结合的方式作为SSC主场电源的改造方案。电源总体分为两部分,采用模块化的开关电源作为前级电压源,三极管线性调整电路作为后级模块的主电路,充分利用两种电源的优势,实现高稳定度、低纹波的电流输出,同时大幅度提升电源的功率密度和可靠性。文章介绍了电源的工作原理及改造过程,详细阐述了三极管线性放大原理以及管压降控制电路、输出电流控制电路的设计与实现,通过仿真对电路进行功能验证,最终在电源样机上进行实验测试。测试结果表明:改造后主场电源输出电流稳定度达到了±3.99×10?6,电流纹波达到了2.7×10?9,各项性能均优于改造前。  相似文献   
8.
应用于强流重离子加速器装置增强环(HIAF-BRing)的快循环全储能脉冲电源需要在极宽的输出电压范围内保持极高的控制精度,为此电源采用了高压功率单元和低压功率单元串联的拓扑方式,在低压段采用低压功率单元,电压升高之后切换到高压功率单元,通过高低压切换控制来实现电流全阶段的高精度输出。但是在样机实测中发现存在切换点的振荡问题,导致切换点处的输出电流绝对误差无法满足指标要求。本文提出了一种切换点平滑控制算法来平滑处理切换点占空比,给出了仿真结果,并且在HIAF-BRing快循环全储能脉冲电源样机上面实际验证了高低压切换控制方法及其切换点平滑控制算法的有效性。实验结果表明:100 A注入平台的输出电流绝对误差由±500 mA降至±50 mA, 100 A注入平台的切换点处输出电流绝对误差由±1.16 A降至±120 mA,100 A注入平台输出精度较低的问题得以解决。  相似文献   