首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
<正> The title com pound (HHOMP) has been synthesized with the pho-toinduced condensation of acetone and pyrrole in the presence of iodoaromatic hydrocarbons, and its molecular and crystal structures have been determined by X-ray analysis. C28H36N4, Mr = 428. 63, triclinic; space group P1; a =10. 165(3), b = 10. 185(2), c=13. 012(3)(?); α=85. 41(2), β=67. 84(2), γ= 89. 75(2)°; V = 1243 (?)3; Z = 2; D = 1. 145g. cm-3; μ= 0. 635cm-1; F (000) = 464. Although the HHOMP molecule twists, it is found that the four nitrogen atoms are still in a plane.  相似文献   

2.
用从头算方法,在HF/STO-3G、HF/3-21G和HF/6-31G水平上研究了小硅化物SiX^m4的成键倾向性。计算结果表明,所研究的分子势能曲线均有稳定的极小值(SiLi4除外)。与已知的稳定分子SiH1、SiF4和SiCl4比较,含惰性元素的未知分子SiHe^4+4、SiNe^4+4和SiAr^4+4比含碱金属和碱土金属的未知分子SiLI4、SiNa4、SiBe^4+4和SiMg^4+4有  相似文献   

3.
张宏  孙仁安  李纳  阎杰 《结构化学》2006,25(3):279-284
1 INTRODUCTION In the later 60s of last century, silicon substituted for germanium to present as mainstream in semicon- ductor. The semi-conductive devices made by silicon have many advantages, for example, refractory pro- perty, high radioresistance, simple and stable process- ing technic, high machinability and low cost. So it was widely used to manufacture large power appara- tuses, for instance, digit and linear integrated circuit, large scale integrated circuit (LSI), etc. Thus, th…  相似文献   

4.
5.
6.
急性心肌梗塞患者血清硒,锌,铜,钙,镁,铁,锶含量的测定   总被引:4,自引:0,他引:4  
分别对29例急性心肌梗塞(AMI)病人和40例健康人进行血清中七种微量、常量元素含量测定,结果表明,AMI患者血清Se、Zn、Ca较正常对照组明显降低;血清Cu显著增高,血清Fe、Mg较对照组低,差异不显著;血清Sr两组无差异。对AMI患者与血清硒及各元素间相互关系进行了探讨,指出调整人体微量、常量元素的不平衡状况,对冠心病和AMI的发生、发展和康复有一定的临床意义。  相似文献   

7.
锌,铁,锰,铜,铅,镉,砷的示波极谱连续测定   总被引:1,自引:1,他引:1  
王河川 《分析化学》1989,17(2):192-192
  相似文献   

8.
9.
硫酸镍中Ca,Mg,Cu,Fe,Pb,Zn的光谱测定   总被引:2,自引:0,他引:2  
用发射光谱法测定结晶硫酸镍中Ca,Mg,Cu,Fe,Pb,Zn等杂质元素,加入NaCl为缓冲剂改善杂质元素的激发行为,以提高分析的灵敏度。用交流电弧激发,以镍为内标,一次摄谱,可同时测定上述六种元素。此法快速、准确,满足实际需要。  相似文献   

10.
11.
建立电感耦合等离子体原子发射光谱(ICP–AES)法测定铬镍不锈钢中锰、铬、镍、硅、磷、铜、钼7种元素含量的方法。试样用盐酸与硝酸混合酸溶液溶解,采用溶解国家标准样品的方法制备校准曲线溶液,确定了元素最佳分析谱线。各元素的含量在其测试范围内与原子发射强度呈良好的线性关系,线性相关系数不小于0.999,7种元素的检出限在0.000 3%~0.003 0%之间。该方法应用于铬镍不锈钢标准样品的测定,测定值与认定值相符,测定值的相对标准偏差在0.12%~1.15%之间(n=8)。应用于铬镍不锈钢样品测定时,加标回收率在90%~110%之间。该方法操作简便、迅速,可满足日常铬镍不锈钢中多元素含量的检测需要。  相似文献   

12.
通过用四酸与微波消解法溶解样品对比,建立了用硝酸、盐酸、氢氟酸、高氯酸分解样品,采用电感耦合等离子体质谱法(ICP-MS)测定稀土矿中16种元素含量。方法采用103Rh作为内标消除干扰,确定了最优测定条件,16种稀土元素检出限为0.0029-0.0099ng/mL,测定范围为0.0005-0.020%。精密度试验、加标回收试验及标准物质检测,结果验证了方法的可行性及准确性。该方法简单易操作,结果可靠,能满足实验分析要求。  相似文献   

13.
建立X射线荧光光谱法快速测定黑铜中的铜,砷,锑,铋,铅,镍,锌和锡等多种元素含量的方法。采用自制的黑铜样品作为标准样品建立标准工作曲线。实验确定了样品加工时最佳的铣样速度及谱线重叠干扰的校正方法,并用理论影响系数校正基体干扰。试验结果表明,各元素的工作曲线线性关系较好,线性相关系数均大于0.996。各元素的检出限在17~47μg/g之间。测定结果的相对标准偏差为0.038%~2.73%(n=7)。两个样品的测定结果与标准分析方法的测定结果相符。该方法具有较好的准确度和精密度,分析速度快,能满足炉前快速分析的需要。  相似文献   

14.
建立了电感耦合等离子体原子发射光谱法测定镍基钎料中Cr,Si,B,Fe含量的新方法。以硝酸–氢氟酸溶解样品,分别选择267.716,288.158,249.677,259.940 nm作为分析谱线,不用进行基体匹配,可直接测定镍基钎料中Cr,Si,B,Fe含量。在优化的实验条件下,测定结果的相对标准偏差为0.71%~1.43%(n=11),加标回收率为97.0%~102.0%。该方法可满足日常分析对镍基钎料中Cr,Si,B,Fe含量的检测要求。  相似文献   

15.
ICP-OES法测定镍铬合金中Si,Mn,Fe,Ti,Al,Cu多种元素   总被引:2,自引:0,他引:2  
建立了电感耦合等离子体发射光谱法测定镍铬合金中Si,Mn,Fe,Ti,Al,Cu元素含量的分析方法。确定了溶样方法和分析谱线,采用基体匹配消除干扰。对方法精密度和准确度进行实验,实验结果表明,各元素的相对标准偏差均小于3%,加标回收率在86.8%~106.9%,镍铬合金标准物质的各元素测定结果均与标准值一致。所建立的方法快速、准确,适用于镍铬合金中多元素同时测定。  相似文献   

16.
建立ICP–AES法测定新型材料镍铁中的Si,Mn,P,Ni元素的方法。考察了镍铁基体和共存元素对测定结果的影响。通过基体匹配消除基体干扰,确定各待测元素谱线为Mn 293.930 nm,P 178.280 nm,Ni 231.604 nm,Si251.611 nm。Si,Mn,P,Ni的检出限分别为0.06,0.04,0.08,0.04 mg/L,测定结果的相对标准偏差均小于5%(n=11),加标回收率在95%~105%之间。该方法操作简便、测定结果准确可靠,可用于镍铁中Si,Mn,P,Ni的含量测定。  相似文献   

17.
The present paper describes radiochemical separation procedures developed for the determination of seven elements: As, Cd, Cr, Cu, Hg, Sb and Se in different Brazilian regional diets. In the case of the elements As, Hg, Sb and Se, the procedure was based on retention in inorganic exchanger TDO (tin dioxide) and determination of Hg by extraction with Ni(DDC)2. For determination of Cd, Cr, Cu and Se the procedure chosen was based on retention in inorganic exchanger HMD (hydrated managese dioxide) and extraction of Cu and Cd as diethyldithiocarbamate compounds. The accuracy and precision of the methods studied were tested by means of analyses of different reference materials. Due to the lack of data on trace element levels in Brazilian foodstuffs and diets, these methods were applied to determination of these elements in different Brazilian regional diets. These diets were supplied by the Food and Experimental Nutrition Department of the Faculty of Pharmaceutical Science, University of São Paulo. The daily dietary intake values for these diets are presented for As, Cd, Cr, Cu, Hg, Sb and Se.  相似文献   

18.
研究了用ICP-AES法测定松树脂中的铁、铅、铜、锌、铝的方法,确定了松树脂中杂质元素同时测定的最佳工作条件.并对实际样品用 ICP- AES与AAS法对比试验,回收率在91%-104%之间,结果令人满意。该法快速、简便、可靠,适用于出口松树脂的日常检验。  相似文献   

19.
The objective of this work was to investigate the dependence of atomic emission detector C and H response on microwave-induced plasma conditions and to improve the accuracy of carbon-to-hydrogen ratio determination for trialkylphosphates, herbicides, chlorophenols, and sulfur-containing organic compounds. Compounds which differed structurally from the analytes were used as reference compounds. It was found that when the oxygen concentration in the helium was the maximum for the instrument (9%) relative errors in carbon-to-hydrogen ratio determination were 3–8%, irrespective of analyte and reference compound structure, whereas when working in the mode of operation recommended by the manufacturer of the instrument (1.5% oxygen in helium) the respective errors were 10–20% or higher. This improvement in the accuracy of carbon-to-hydrogen ratio determination was accompanied by a factor of ten decrease in sensitivity.  相似文献   

20.
通过对化探样品进行王水密闭溶解,饱和的硫脲-抗坏血酸预还原,运用氢化物发生-原子荧光光谱法实现了地质样品中As、Sb、Bi、Hg元素的任意配对以及连续快速测定。实验确定了原子化器高度为14mm,最佳溶样时间为1h。在优化条件下,结果显示还原剂(硫脲-抗坏血酸)对Hg、Bi测定结果无影响,且Hg、Bi测定结果在预还原20min至48h内都很稳定,测定结果良好,Cu、Co、Ni、Au、Ag、Cd、As、Sb、Bi、Se、Ge等金属离子对预还原测定汞均无干扰,对比实验表明还原剂体系下汞荧光强度值基本不变。方法的检出限低、精密度好、准确度高、操作简便,有效避免了元素污染问题,可满足大批量地质样品分析测定的需要。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号