首页 | 本学科首页   官方微博 | 高级检索  
     检索      

电感耦合等离子发射光谱法测定镍铁中Si,Mn,P,Ni
引用本文:李建梅,王慧清,郝静.电感耦合等离子发射光谱法测定镍铁中Si,Mn,P,Ni[J].化学分析计量,2014(5):88-90.
作者姓名:李建梅  王慧清  郝静
作者单位:内蒙古第一机械集团有限公司计量检测中心;
摘    要:建立ICP–AES法测定新型材料镍铁中的Si,Mn,P,Ni元素的方法。考察了镍铁基体和共存元素对测定结果的影响。通过基体匹配消除基体干扰,确定各待测元素谱线为Mn 293.930 nm,P 178.280 nm,Ni 231.604 nm,Si251.611 nm。Si,Mn,P,Ni的检出限分别为0.06,0.04,0.08,0.04 mg/L,测定结果的相对标准偏差均小于5%(n=11),加标回收率在95%~105%之间。该方法操作简便、测定结果准确可靠,可用于镍铁中Si,Mn,P,Ni的含量测定。

关 键 词:镍铁  快速分析

Deternimation of Si,Mn, P,Ni in Ferronickel by ICP-AES
Li Jianmei;Wang Huiqing;Hao Jing.Deternimation of Si,Mn, P,Ni in Ferronickel by ICP-AES[J].Chemical Analysis And Meterage,2014(5):88-90.
Authors:Li Jianmei;Wang Huiqing;Hao Jing
Institution:Li Jianmei;Wang Huiqing;Hao Jing;Measurement Testing Center,In Inner Mongolia, the First Group Machinery Co. Ltd.;
Abstract:A method for determination of silicon, manganese, phosphorus, nickel content in new materials ferronickel by ICP-AES was established. The interference from matrix and co-existing elements was studied. The matrix effect was corrected by matrix matching. The analysis lines were Mn 293.930 nm, P 178.280 nm, Ni 231.604 nm, Si 251.611 nm. The detection limits of Si, Mn, P, Ni were 0.06, 0.04, 0.08, 0.04 mg/L, respectively. The relative standard deviation of determination results was below 5%, and the recovery was 95%-105%. This method is easy to operate with accurate results, and it is suitable for determination of Si, Mn, P, Ni contents in ferronickel.
Keywords:ICP-AES  Si  Mn  P  Ni  ICP-AES  ferronickel  rapid analysis  Si  Mn  P  Ni
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号