首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
高效液相色谱法测定长柄扁桃仁中的苦杏仁甙   总被引:2,自引:0,他引:2  
建立了高效液相色谱法测定长柄扁桃仁中的苦杏仁甙的方法.样品中的苦杏仁甙用甲醇超声提取20 min.在Shim-pack VP-ODS(250 mm×4.6 mm i.d.,5 μm)色谱柱上,以V(甲醇):V(水):V(乙腈)=10:40:50为流动相进行洗脱,检测波长215 nm的条件下,测得长柄扁桃仁中苦杏仁甙的平均质量分数为35.40 mg/g.该法线性范围为0.64~32.0 mg/L,线性相关系数r=0.9997,检出限为1.1 μg/L,平均回收率为94%(N=3).此法可为果仁中苦杏仁甙的测定提供参考.  相似文献   

2.
建立了高效液相色谱法测定营养液中吩嗪酮含量的方法,采用Aichrom Bond-AQ C18色谱柱(250 mm×4.6 mm,5μm),流动相为甲醇∶水(40∶60,V/V),流速为1.0 mL/min,检测波长为315 nm.外标法定量,吩嗪酮在1.0~200 mg/L(r=0.9996)的浓度范围内呈线性关系.方法的检出限为0.02 mg/L,回收率为96.0%~99.0%,相对标准偏差为0.20%(n=6).该方法简便、准确、易行,可用于质量控制.  相似文献   

3.
建立了固相萃取-高效液相色谱测定降糖汤药中化学添加成分盐酸二甲双胍的方法。降糖汤药样品经乙醇涡旋超声提取后,使用弱阳离子固相萃取小柱净化后进样,使用Lnertsil ODS-3 C18(4.6 mm×250 mm,5μm)色谱柱,流动相为乙腈:甲醇:0.02 mol/L乙酸铵=20:20:60(V/V/V),流速0.4 m L/min,柱温30℃,紫外检测波长237 nm,外标法定量。标准曲线的线性范围在2.5~200 mg/L之间,相关系数r~2=0.9998,方法检出限为0.04 mg/L,加标回收率为89.5%~93.9%,RSD为5.3%。方法适用于降糖汤药中盐酸二甲双胍非法添加量的测定。  相似文献   

4.
建立了同时测定痹祺胶囊中马钱子碱、士的宁和丹酚酸B含量的方法.采用反相高效液相色谱法,色谱柱:Inertsil ODS-3(250 mm×4.6 mm,5 μm);流动相:V(乙腈): V(10 mmol/L己烷磺酸钠的磷酸盐缓冲液,pH 2.86)=22: 78;流速: 1.0 mL/min;检测波长: 254 nm;柱温:25 ℃.马钱子碱、士的宁和丹酚酸B的线性范围分别为2.7~32 mg/L(r=0.9998)、2.6~31 mg/L(r=0.9999)和12.7~151 mg/L(r=0 9991);平均加样回收率(n=6)分别为99.3%、95.6%和98.9%;RSD分别为2.30%、3.68%和1.82%.本方法简便快捷,结果准确,可用于痹祺胶囊的质量控制.  相似文献   

5.
2,4-二硝基氟苯柱前衍生高效液相色谱法测定18种氨基酸   总被引:15,自引:0,他引:15  
建立了测定18种氨基酸的高效液相色谱方法。以Hypersil ODS-c_(18)柱(100mm×4.6mm i.d.,5μm)为色谱柱,2,4-二硝基氟苯为衍生化试剂,梯度洗脱。流动相A:0.05mol/L乙酸钠缓冲溶液(pH=6.5,含10mL/LN,N-二甲基甲酰胺),流动相B:乙腈-水(体积比为1:1)。所测氨基酸组分的浓度在0.2~3.0mg/L范围内与峰面积之间具有良好的线性关系,回收率为90.4%~101.0%,检出限为0.120~1.225mg/L,测定结果的相时标准偏差为1.05%~5.93%。  相似文献   

6.
为建立HPLC法测定怀菊花中没食子酸含量测定方法,采用Agilent C18柱(150 mm ×4.6mm,5μm),以V(甲醇)+V(超纯水+0.1%磷酸)=25 +75为流动相,流量:0.5 mL· min-1;柱温为25℃,检测波长:258 nm;进样量:10 μL,进行测定.结果表明,回归方程为y=3.054 2x-2.207 1,r2=0.999 1(n=6),线性范围0~20 μg,平均回收率97.28%,RSD为3.39%.样品中没食子酸质量分数为3.17 mg/g.方法快速、简便、准确、重现性较好,结果可靠,可为怀菊花中没食子酸的质量评价提供依据.  相似文献   

7.
建立了固相萃取-高效液相色谱法(SPE-HPLC)测定水果中农药单甲脒残留量的检测方法.用HCl溶液将样品中单甲脒转化为盐酸盐并溶于水中,在碱性条件下用乙腈提取,经碱性氧化铝固相萃取柱净化.采用C18柱(250 mm×4.6 mm,5 μm)分离,以甲醇-0.01 mol/L乙酸铵溶液(50∶ 50, V/V)为流动相,在254 nm下检测.本方法可以将单甲脒与基质良好分离,在0.01~10 mg/L浓度范围内线性良好(R2=0.9999);检出浓度为0.0013 mg/kg,回收率为80.7%~95.3%,相对标准偏差小于7%,可用于水果中单甲脒残留量的检测.  相似文献   

8.
离心破乳-气相色谱法测定黑米中残留抑霉唑的研究   总被引:1,自引:0,他引:1  
报道了离心破乳-气相色谱法测定黑米中残留抑霉唑的方法. 考察了不同离心速率、不同离心时间的破乳效率. 试样以V(正己烷):V(乙酸乙酯)=1:1提取, 经毛细管气相色谱柱HP-5 (30 m×0.25 mm×0.25 μm)分离, μ-ECD检测器测定. 方法检出限为1.0×10-3 mg/kg (S/N=3). 在添标水平0.05、 0.25和0.50 mg/kg时的平均回收率为92.3%~104.3%, 相对标准偏差为6.9%~9.3%. 线性范围为0.02~1.0 mg/L (r2=0.9994). 方法适合黑米中残留抑霉唑的测定.  相似文献   

9.
采用反相高效液相色谱法测定了鸭肉中的三聚氰胺.Diamonsil C18柱,流动相:V(乙腈)∶V(4 mmol/L己烷磺酸钠水溶液)=5∶95,乙酸调pH为3.3;检测波长240 nm.在0.25~40 mg/L范围内线性关系良好,相关系数R=0.9999.方法检出限0.056 mg/kg,回收率在80%~86%之间,相对标准偏差小于2.55%.  相似文献   

10.
建立了柑橘、苹果、菠菜、西红柿等水果和蔬菜中乙萘酚的高效液相色谱-荧光快速检测方法。样品用乙腈提取,浓缩,乙腈-甲苯(3:1,V/V)溶解后经LC-NH2固相萃取柱净化;色谱柱:Pickering C18(250 mm×4.6 mm,5μm);流动相:乙腈-水(50:50,V/V);检测波长:λex=250 nm,λem=410 nm。乙萘酚在0.20~50.00 mg/L范围内线性关系良好(r=0.9999);在0.05,0.10,0.50 mg/kg 3个添加水平下平均回收率范围在83.3%~101.2%之间,相对标准偏差为4.3%~9.3%。  相似文献   

11.
建立了羊肉组织中胺菊酯和三氟氯氰菊酯的固相萃取-反相高效液相色谱测定法。采用氟罗里硅土固相萃取柱(1000 mg/6 mL)进行固相萃取。以Shim-pack VP-ODS(200 mm×4.6 mm)柱为分析柱,流动相为甲醇:水=95:5(V/V),流速为0.7 mL/min。胺菊酯和三氟氯氰菊酯分别在0.01~6.40μg/mL(r=0.9999)和0.068~7.20ug/mL(r=0.9998)范围内与峰面积呈良好线性关系,检出限分别为0.001μg/mL和0.002μg/mL,胺菊酯和三氟氯氰菊酯的回收率为90.2%~101.4%,相对标准偏差为2.3%~4.0%。该方法可作为羊肉组织中胺菊酯和三氟氯氰菊酯含量监测的控制方法。  相似文献   

12.
A simple method was developed for the determination of fluquinconazole, pyrimethanil, and clofentezine in whole fruit; peel; and pulp of mango, apple, and papaya. These compounds were extracted from fruit samples with a mixture of ethyl acetate-n-hexane (1 + 1, v/v). An aliquot (2 mL) of the extract was evaporated to near dryness under a stream of nitrogen, and the residue was dissolved with 2 mL methanol. The analysis was performed by means of liquid chromatography with ultraviolet detection at 254 nm using a gradient solvent system. The method was validated with fortified fruit samples at concentration levels of 0.05, 0.10, 0.20, and 0.50 mg/kg. Average recoveries (4-8 replicates) ranged from 80 to 95% with relative standard deviations between 3.5 and 12.7%. Detection limits ranged from 0.03 to 0.05 mg/kg for fruit pulp and 0.03 mg/kg for whole fruit. The quantitation limits ranged from 0.05 to 0.10 mg/kg for fruit pulp and 0.05 mg/kg for whole fruit. The analytical method was applied to fruit samples obtained from local markets.  相似文献   

13.
丹参中3种丹参酮的超临界二氧化碳萃取及液相分析   总被引:22,自引:0,他引:22  
 用超临界CO2 流体及共溶剂乙醇萃取丹参中的 3种丹参酮 ,分别采用正交设计法和系统法考察了萃取中的主要影响因素 ;采用高效液相法 (HPLC) ,在甲醇 水 (体积比为 80∶2 0 )溶液为流动相和检测波长为 2 80nm的条件下 ,以外标法检测了萃取产物中 3种丹参酮的含量。实验得到的最佳条件为 :萃取压力 2 0MPa ;萃取温度 4 5℃ ;分离温度 35℃ ;共溶剂 95 % (体积分数 )乙醇 ;流量 1 0mL/min。建立的HPLC测定方法简便快捷 ,准确度高 ,重现性良好 ,相关系数r为 0 9994~ 0 9998,相对标准偏差RSD为 2 37%~ 3 4 7%。  相似文献   

14.
高聚物型色谱柱分离乙酰半胱氨酸及其有关物质   总被引:2,自引:0,他引:2  
考察高聚物型色谱柱(聚苯乙烯-二乙烯基苯(PS-DVB)麦科菲反相高效液相色谱柱,MKF-RP-MH)分离乙酰半胱氨酸以及有关物质的适用性。采用MKF-RP-MH色谱柱(4.6×250 mm,5μm),V(0.02 mol/L的磷酸盐缓冲液(pH 3.0))∶V(乙腈)=9∶1为流动相,流速为1 mL/min,检测波长210 nm,柱温为25℃。乙酰半胱氨酸峰与有关物质峰的分离度均大于1.5;乙酰半胱氨酸质量浓度在11~111 mg/L的范围内,具有良好的线性关系,回归方程为A=18.195ρ+0.5229,r=0.9995(n=8);乙酰半胱氨酸的定量限为11 mg/L;最低检测限为0.035μg;进样精密度RSD=0.24%(n=6)。  相似文献   

15.
高效液相色谱-荧光检测法测定葡萄酒中总亚硫酸盐   总被引:5,自引:0,他引:5  
卫锋  陈明生  于玲  常丽  李冬敏 《色谱》1999,17(6):583-585
 摘要:建立了测定葡萄酒中总亚硫酸盐的高效液相色谱方法。N-(9-吖啶基)马来酰亚胺与样品中亚硫酸盐反应生成一种较强的荧光络合物,利用荧光检测器进行检测。方法具有样品用量少、操作简便、灵敏度高等特点,回收率为98.0%~103.0%,相对标准偏差小于4.6%。  相似文献   

16.
液相色谱/蒸发光散射测定转基因烟草提取液中的海藻糖   总被引:6,自引:0,他引:6  
魏泱  丁明玉 《色谱》2001,19(3):226-229
 采用乙二胺动态修饰硅胶柱分离、蒸发光散射检测器测定了转基因烟草提取液中的糖。 4种糖的峰面积标准曲线在 10 0mg/L~ 15 0 0mg/L范围内均具有良好的线性关系。所建立的方法对果糖、葡萄糖、蔗糖、海藻糖的检测下限分别为 10mg/L ,2 0mg/L ,10mg/L和 10mg/L。  相似文献   

17.
建立了一种超高效合相色谱法( Ultra performance convergence chromatography,UPC2)分离和测定盐酸兰地洛尔中立体异构体的方法。本方法选用Daicel CHIRALPAK? IF手性色谱柱(150 mm ×4.6 mm,3μm),以CO2为流动相,甲醇-正丁醇-乙腈(1:1:1, V/V)+0.5%氨水为助溶剂,梯度洗脱,流速为2.8 mL/min,检测波长为223 nm。在建立的UPC2条件下,盐酸兰地洛尔的R,R-异构体、R,S-异构体和S,R-异构体的检出限分别为0.3、0.4和0.3 mg/L;线性范围分别为2~300 mg/L、5~300 mg/L和2~300 mg/L;加标回收率分别为103.4%,91.8%和101.7%;进样精密度分别为0.06%,0.09%和0.08%(n=6)。本方法能够满足盐酸兰地洛尔样品中3个立体异构体检查的相关要求。  相似文献   

18.
王水  唐琳  郭亦然  颜钫  陈放 《色谱》2001,19(2):128-131
 建立了一个快速、简单、准确的固相萃取和高效液相色谱相结合的测定苦瓜甙A含量的方法。样品经石墨碳固相萃取管 (3mL/ 2 5 0mg)纯化后以高效液相色谱检测。色谱柱为C18,流动相为V(乙腈 )∶V(甲醇 )∶V(5 0mmol/L磷酸二氢钾缓冲液 ) =2 5∶2 0∶6 0 ,流速为 0 .8mL/min ,检测波长为 2 0 8nm。标准曲线自 10mg/L到 10 0 0mg/L呈线形关系 (r2 =0 .9992 )。该方法具有很好的重现性 ,日内或日间的相对标准偏差和相对平均误差均小于 10 %。样品回收率大于 90 %。  相似文献   

19.
高效液相色谱法测定人血清中鬼臼乙叉甙浓度   总被引:2,自引:0,他引:2  
解建勋  李玉珍  王佩 《色谱》1998,16(1):74-75
建立了测定血清中鬼臼乙叉甙浓度的反相高效液相色谱方法。血清样品以乙酸乙酯提取,加表鬼臼毒噻吩糖甙作内标,以甲醇∶水(55∶45)为流动相,紫外254nm检测,最低检测浓度0.1mg/L,在药物浓度为0.5~50mg/L范围内有良好的线性关系,Y=0.0160+0.0340X,r=0.9991,回收率达95.0%。日内、日间精密度分别为4.16%和4.76%(n=5)。用所建立的方法测定了患者的血清浓度,结果表明,方法简便、灵敏。  相似文献   

20.
高效液相色谱法测定新生儿血清中去甲万古霉素浓度   总被引:8,自引:0,他引:8  
 建立了反相高效液相色谱测定新生儿败血症患者血清中去甲万古霉素浓度的方法。血清样品经乙腈-异丙醇沉淀蛋白,上清液用三氯甲烷萃取后以水相进样。流动相为乙腈-磷酸盐缓冲液,紫外检测,最低检测限0.3mg/L,有良好的线性关系,回收率达94.7%,日内、日间精密度分别为2.23%和2.62%。结果表明,方法简便、有效。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号