排序方式: 共有12条查询结果,搜索用时 15 毫秒
1.
After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber, a full system covering all the channels of high voltage was installed. The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber. The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported. The full system of high voltage power supply works stably and reliably. 相似文献
2.
3.
吴智 刘建北 秦中华 伍灵慧 陈昌 陈元柏 陈玛丽 陈锡辉 董明义 关北菊 黄杰 江晓山 金艳 李飞 李仁英 李小男 雷广坤 刘荣光 罗小兰 马骁妍 盛华义 孙汉生 唐晓 王岚 王靓 徐美杭 张建 章红宇 张银鸿 赵豫斌 赵平平 朱科军 朱启明 庄保安 《中国物理 C》2010,34(7):983-987
The BESⅢ drift chamber and its subsystems need a cosmic-ray test after the chamber construction to check the chamber construction quality,testing the joint operation of the whole system and the performance of the chamber.The noise performance,drift time and charge measurements,and the scanning of channels were examined specifically.The preliminary results of the test indicate that the whole system works well. 相似文献
4.
A Gas Electron Multiplier (GEM) detector with an effective area of 300 mm×300 mm has been constructed using a novel self-stretching technique, which allows a highly flexible and efficient GEM detector assembly free of glue or spacers. This makes the re-opening and repair of the GEM detectors possible and significantly reduces the scrap rate in the mass production of large-area GEM detectors. With the technique, the assembly time can be limited to a few hours, a factor of ten improvement compared to that using gluing techniques. The details of design and assembly procedure of the 300 mm×300 mm GEM detector are described in this paper. This detector was tested with 8 keV X-rays for the effective gain, energy resolution and performance uniformity. The results show that the typical energy resolution is 20% at an effective gain of about 10^4, with fairly good uniformity. 相似文献
5.
利用宇宙线分别研究了一个小单元漂移室在He/C3H8(60/40)和He/CH4(60/40)两种氦基混合气下的性能.作为比较还测试了在Ar/CO2/CH4(89/10/1)混合气下的性能.研究表明上述氦基混合气的空间分辨和dE/dx分辨好于Ar/CO2/CH4(89/10/1)混合气.使用He/C8H8(60/40)可以获得110μm的空间分辨,在30—40次取样下dE/dx分辨可以达到6%—7%. 相似文献
6.
7.
安芬芬 白羽 陈春晖 陈新 陈振兴 Joao Guimaraes da Costa 崔振崴 方亚泉 付成栋 高俊 高艳彦 高原宁 葛韶锋 顾嘉荫 郭方毅 郭军 韩涛 韩爽 何红建 何显柯 何小刚 胡继峰 徐士杰 金山 荆茂强 Susmita Jyotishmati Ryuta Kiuchi 郭家铭 赖培筑 李博扬 李聪乔 李刚 李海峰 李亮 李数 李通 李强 梁浩 梁志均 廖立波 刘波 刘建北 刘涛 刘真 娄辛丑 马连良 Bruce Mellado 莫欣 Mila Pandurovic 钱剑明 钱卓妮 Nikolaos Rompotis 阮曼奇 Alex Schuy 单连友 史静远 史欣 苏淑芳 王大勇 王锦 王连涛 王贻芳 魏彧骞 许悦 杨海军 杨迎 姚为民 于丹 张凯栗 张照茹 赵明锐 赵祥虎 周宁 《中国物理C(英文版)》2019,(4)
The discovery of the Higgs boson with its mass around 125 GeV by the ATLAS and CMS Collaborations marked the beginning of a new era in high energy physics.The Higgs boson will be the subject of extensive studies of the ongoing LHC program.At the same time,lepton collider based Higgs factories have been proposed as a possible next step beyond the LHC,with its main goal to precisely measure the properties of the Higgs boson and probe potential new physics associated with the Higgs boson.The Circular Electron Positron Collider(CEPC)is one of such proposed Higgs factories.The CEPC is an e~+e~- circular collider proposed by and to be hosted in China.Located in a tunnel of approximately 100 km in circumference,it will operate at a center-of-mass energy of 240 GeV as the Higgs factory.In this paper,we present the first estimates on the precision of the Higgs boson property measurements achievable at the CEPC and discuss implications of these measurements. 相似文献
8.
A method to determine precisely three-dimensional wire positions in the BESⅢ drift chamber using physics events is introduced. In part the proposed technique takes advantage of the possibility that the magnetic field can be turned off, thereby providing a huge sample of straight tracks for which effects due to multiple scattering, energy loss and non-uniformity of the magnetic field are minimized during the calibration process. A toy Monte Carlo study is performed to demonstrate the viability of the method. As a result of the calibration process, the rms of the distribution of wire position deviation is reduced from 35μm to 10μm. 相似文献
9.
10.
小单元漂移室用放射源模拟老化的实验研究 总被引:2,自引:0,他引:2
BESⅢ 漂移室(DC)模型用1.85X109 Bq 55Fe 5.9keV X射线放射源作加速老化实验研究.测量了阳极丝电流I和55Fe 5.9keV X射线全能光电峰位随累积电荷量Q的变化,由此得到累积相当BESⅢ DC 5年全天候运行的电荷量(0.07 C/cm)后,漂移室小单元的阳极电流降为初始值的87%;老化率为R=-0.19%/(mC/cm) 相似文献