排序方式: 共有46条查询结果,搜索用时 15 毫秒
1.
The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (T0) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a T0 detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. T0 detector timing resolutions of ~41-62 ps are achieved, which means that the T0 detector can be used in the MRPC beam test. 相似文献
2.
3.
4.
5.
A new kind (two end readout) of Multi-gap Resistive Plate Chamber with long readout-strip (LMRPC) is developed to be used at the large-area Muon Telescope Detector (MTD) at mid-rapidity at RHIC/STAR experiment for Time-of-Flight (TOF) measurement. The LMRPC has an active area of 87 cm× 17 cm, 10 gas gaps of 250 μm arranged in 2 stacks, with readout strips of 2.5 cm wide and 90 cm long. The considerations in LMRPC design related to its performance are discussed in this paper. The cosmic ray test results of a prototype LMRPC show a detection efficiency 〉95% and the time resolution -70 ps. 相似文献
6.
A GEANT4-based Monte-Carlo (MC) model is developed to study the performance of endcap time-of-flight (ETOF) at BESⅢ. It's found that the multiple scattering effects, mainly from the materials at the MDC endcap, can cause multi-hit on the ETOF's readout cell and significantly influence the timing property of ETOF. A multi-gap resistive plate chamber (MRPC) with a smaller readout cell structure is more suitable for the ETOF detector due to significantly reduced multi-hit rate (per channel), from 71.5% for currently-used scintillator-based ETOF to 21.8% or 16.7% for MRPC-based ETOF, depending on the readout pad size used. The timing performance of an MRPC ETOF is also improved. These simulation results suggest and guide an ETOF upgrade effort at BESⅢ. 相似文献
7.
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESⅢ). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%. 相似文献
8.
上海市第24届初中物理竞赛(大同中学杯)复赛试卷的填空题第12题引起了笔者的注意.题目:如图1所示,直角三角板ABC的边长BC=a,AC=b.开始时AB边靠在y轴上,B与坐标原点O重合.今使A点沿y轴负方向朝O点移动,B点沿x轴正方向移动,可知三角板从图1(a)所示的初始 相似文献
9.
10.
赵川 孙胜森 李澄 张晓杰 何康林 安琪 陈宏芳 代洪亮 封常青 衡月昆 黄亚齐 黄燕萍 郭建华 李卫东 李秀荣 刘芳 刘怀民 刘树彬 刘曙东 刘勇 马想 毛泽普 邵明 孙勇杰 孙志嘉 吴金杰 杨桂安 赵雷 朱兴旺 左嘉旭 《中国物理 C》2011,35(1)
The time calibration for end cap TOF system of BESⅢ is studied in this paper. It has achieved about 110 ps time resolution for muons in dimu events. The pulse height correction using electronic scan curve and the predicted time calculated using Kalman filter method are introduced. This paper also describes the study of using electrons and muons as calibration samples. 相似文献