首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
  国内免费   12篇
数学   1篇
物理学   14篇
  2022年   2篇
  2017年   1篇
  2013年   2篇
  2012年   2篇
  2011年   3篇
  2010年   1篇
  2009年   1篇
  2008年   2篇
  2007年   1篇
排序方式: 共有15条查询结果,搜索用时 156 毫秒
1.
The endcap of time-of-flight (ETOF) detector in BES (Beijing Spectrometer) III is planned to be upgraded by using multi-gap resistive plate chambers (MRPCs) and the designed time resolution of the MRPCs is around 50 ps. Thus a time-zero (T0) detector needs to be built to offer a high quality reference time for the MRPCs beam test. So a T0 detector is built using plastic scintillator tiles (BC420) to couple with four fast phototubes (PMTs, Hamamatsu H6533). The timing properties of the detector is studied by using a cosmic ray test and factors related to the time resolution, such as plastic scintillator size, readout mode and angle effects, are discussed. T0 detector timing resolutions of ~41-62 ps are achieved, which means that the T0 detector can be used in the MRPC beam test.  相似文献   
2.
3.
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESⅢ). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%.  相似文献   
4.
A position-sensitive detector is designed for neutron detection. It uses a single continuous screen of a self-made lithium glass scintillator, rather than discrete crystal implementations, coupling with a multi-anode PMT (MaPMT). The scintillator is fast and efficient; with a decay time of 34 ns and thermal neutron detection efficiency of around 95.8% for the 3 mm thick screen, and its light yield is around 5670 photons per neutron and 3768 photons per MeV γ rays deposition. The spatial resolution is around 1.6 mm (FWHM) with the energy resolution around 34.7% by using α (5.2 MeV) rays test.  相似文献   
5.
6.
传统的塑料闪烁体由于其低有效原子序数和密度,不适用于能谱探测领域。有机重金属化合物掺杂塑料闪烁体的制备为塑料闪烁体实现能谱探测提供了一种有效途径。而有机锡化合物掺杂塑料闪烁体具有高光峰灵敏度,并保留了塑料闪烁体的快衰减特性。本文通过自由基聚合的方法成功制备了不同浓度2-(三丁基锡烷基)呋喃掺杂的聚乙烯基甲苯(PVT)基塑料闪烁体,并对其光学和闪烁性能进行了测试和比较。其中掺杂20%2-(三丁基锡烷基)呋喃的PVT基塑料闪烁体的透光率可达90%,X射线激发发射光谱主峰位于425 nm处,光产额为6700 ph/MeV,能量分辨率为15.8%@662 keV,衰减时间约为4.3 ns。我们也制备了1英寸直径、掺杂20%2-(三丁基锡烷基)呋喃的塑料闪烁体,具有6300 ph/MeV的光产额和15.8%@662 keV的能量分辨率。  相似文献   
7.
LiYSiO4:Ce is a promising scintillator and some of its properties have been reported in previous papers. In this paper, samples doped with different concentrations of Ce are prepared and studied. First, the relative light yields of the samples are measured as 28.1%-37.1% compared with a standard anthracene crystal being irradiated by α particles and as ~ 27.2% compared with NaI being irradiated by X-rays. Second, the effects of sample thicknesses on light yields are presented. Finally the timing behaviors of samples with different doped concentrations being irradiated with alpha particles and X-rays are discussed. The result shows that LiYSiO4:Ce is a kind of fast scintillator ( ~ 30 ns) with a moderate light yield that can be used for neutron detection.  相似文献   
8.
The BESⅢ ·RPC with Gd coating as thermal neutron detector was designed and constructed. Three prototypes were built with different techniques of producing the gadolinium converter. The performance of the cosmic ray test, the signal and the radiation spectrum were discussed in this paper. Lastly, the efficiency of one prototype with the best performance for detecting the thermal neutron was tested as 8.7%.  相似文献   
9.
In order to study the possibility of improving the timing performance of the time of flight (TOF) systems, which are made of plastic scintillator counters, and read out by photomultiplier tubes (PMT) with mesh dynodes and conventional electronics, we have conducted a study using faster PMTs and ultra fast waveform digitizers to read out the plastic scintillators. Different waveform analysis methods are used to calculate the time resolution of such a system. Results are compared with the conventional discriminating method based on a threshold and pulse height. Our tests and analysis show that significant timing performance improvements can be achieved by using this new system.  相似文献   
10.
今天早上,我怀着轻松愉快的心情来到了菜市场,心想:好久没有吃番茄了,买几个吧.我刚想上前去问价钱,可是腿不由自主地退了回来,我还真有点儿害羞.为了给自己壮胆,我自言自语地说:“钱森,你平时的胆量都到哪儿去了?”  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号