首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
蜂王浆中磷酸腺苷的提取及超高效液相色谱分析   总被引:2,自引:0,他引:2  
比较了高氯酸提取、热水提取和热硫酸镁溶液提取3种提取方式对蜂王浆中磷酸腺苷三磷酸腺苷(ATP)、二磷酸腺苷(ADP)和单磷酸腺苷(AMP)的提取效果,发现在低温(低于4 ℃)下以5%高氯酸的提取效果最佳。采用超高效液相色谱-紫外检测法分析蜂王浆中的ATP, ADP和AMP的含量。以BEH Shield RP18柱(100 mm×2.1 mm,1.7 μm)为分析柱,以50 mmol/L的磷酸二氢铵(pH 6.5)和乙腈为流动相进行梯度洗脱,3种磷酸腺苷在4 min内实现了较好的分离。以加标王浆样品作添加回收率测定,ATP, ADP和AMP的回收率分别为84.1%~94.3%,86.2%~93.7%和91.0%~104.3%,相对标准偏差均小于10%。方法已被用于一些实际样品的分析,以了解ATP, ADP和AMP在蜂王浆样品中的分布情况。  相似文献   

2.
为解决高纯石墨样品前处理中高温灰化耗时长(4~10 h)的问题,提出了题示方法。取高纯石墨样品0.300 0 g,置于50 mL聚丙烯样品管中,用15 mL 10%(体积分数)王水(体积比为3∶1的盐酸-硝酸混合液)超声提取20 min,提取时会有部分石墨漂浮于液面上,用注射器吸取样品管中部的提取液约3 mL,过0.45μm水系滤膜后收集在样品管中,在灰化温度为900℃、原子化温度为2 000℃等条件下采用石墨炉原子吸收光谱法进行测定。结果表明,超声提取缩短了样品处理时间(仅为20 min)。铅元素的质量浓度在5~50μg·L-1内与对应的吸光度呈线性关系,检出限(3s/k)为0.11 mg·kg-1。对同一样品分析7次,测定值的相对标准偏差为4.6%。按照标准加入法进行回收试验,回收率为91.0%~94.0%。  相似文献   

3.
高含水率土壤样品与无水硫酸钠混合均匀后,以二氯甲烷-正己烷(2+1)混合液为提取剂进行索氏提取,提取液经氢氧化钠溶液净化,再经酸化后由二氯甲烷-乙酸乙酯(4+1)混合液提取,最后进行浓缩,采用气相色谱法测定浓缩液中21种酚类化合物的含量。用HP-5色谱柱(30m×0.25mm,0.25μm)分离,氢火焰离子化检测器检测。21种酚类化合物的质量浓度均在1.0~100.0mg·L~(-1)内与其对应的峰面积呈线性关系,检出限为0.01~0.07mg·kg~(-1)。以空白样品为基体进行加标回收试验,所得回收率为71.4%~95.1%,测定值的相对标准偏差(n=6)为1.0%~11%。  相似文献   

4.
高效液相色谱-串联质谱联用测定脂肪中乙酰孕激素残留   总被引:6,自引:0,他引:6  
建立了脂肪中5种乙酰孕激素,包括醋酸甲羟孕酮(MPA)、醋酸氯地孕酮(CMA)、醋酸甲地孕酮(MEGA)、甲烯雌醇醋酸酯(MLA)及17α-羟基孕酮醋酸酯(HPA)的液相色谱-串联质谱(LC-MS/MS)检测方法。考察了脂肪样品溶剂提取、固相萃取净化对样品分析的影响,确定样品各前处理过程的条件。采用电喷雾(ESI)阳离子,在选择反应监测模式(SRM)下,本方法对5种乙酰孕激素的检出限为0.2~0.3μg/kg,定量限为0.5μg/kg。在空白猪脂肪样品中以0.5、1.0和5.0μg/kg3个水平添加时,5种乙酰孕激素的回收率范围在60.5%~84.1%,RSD为8.9%~16.8%。  相似文献   

5.
高效液相色谱法同时测定甜瓜样品中的抑霉唑和噻菌灵   总被引:12,自引:0,他引:12  
提出了一种用高效液相色谱法 (HPLC)同时测定甜瓜样品中的抑霉唑和噻菌灵残留量的方法。用乙酸乙酯作提取剂提取甜瓜样品 ,通过一个净化步骤分离样品中共提取组分。采用InertsilC8 3色谱柱 (15 0mm× 4 .6mm ,5 μmi.d ,) ,流动相为乙腈∶水 =75∶2 5 ,外标法定量 ,方法的检出限噻菌灵为 0 .70ng ,抑霉唑为1.5 3ng ;回收率为 87.5 %~ 98.0 % ;相对标准偏差为 1.5 %~ 4 .2 %。本法用于甜瓜样品中抑霉唑、噻菌灵含量的测定 ,获得了满意的结果。  相似文献   

6.
气相色谱-质谱法(GC-MS)测定植物油中16种邻苯二甲酸酯类塑化剂(PAEs)的第一步是提取样品中的PAEs。取样品0.500 0g,加入正己烷100μL和乙腈2mL,超声提取5min,离心5min,收集上清液,于留存的下层液相中再加乙腈2mL,重复提取1次。所得上清液与第一次上清液合并在40℃氮吹蒸发至近干。于残渣中加入乙腈1mL使溶解。在此溶液中依次加入无水硫酸镁250mg,N-丙基乙二胺(PSA)80mg和磁性氧化石墨烯50mg,超声萃取5min,通过外加磁场收集经净化的上清液,供GC-MS分析。在GC分析中,采用RXI-5si1MS色谱柱,按程序升温(在80~280℃区间)进行色谱分离,进样量为1μL。在MS分析中采用电子轰击离子源(EI)和选择离子监测(SIM)模式。用基质匹配法绘制标准曲线,测得16种PAEs的线性范围均在0.02~1.00mg·L~(-1)之间,其检出限(3S/N)为0.005~0.008mg·kg~(-1)。以空白植物油为基体,用标准加入法进行回收试验,测得回收率在82.2%~111%之间。16种PAEs测定值的相对标准偏差(n=6)在1.0%~7.2%之间。应用此方法分析了市购的5种植物油样品,并在样品中检出5种PAEs。  相似文献   

7.
建立了海产品、底泥、海水中扑草净药物残留量的液相色谱-串联质谱检测方法。对海产品、底泥样品,采用快速溶剂提取仪(ASE)乙腈提取,凝胶渗透色谱(GPC)净化,液质联用仪(LC-MS/MS)分析;对海水样品采用酸化乙腈提取,氨基固相萃取柱净化,LC-MS/MS分析。实验结果显示,扑草净在浓度0.025~8.0ng/mL时,线性关系良好(R2=0.9999);海产品、底泥样品的方法测定低限为0.25μg/kg,3个加标水平下的平均回收率为90.0%~105.4%,相对标准偏差(RSD)为2.9%~5.3%;海水样品的方法测定低限为0.50μg/L,3个加标水平下的平均回收率为79.5%~99.6%,RSD为3.4%~11.9%。该方法简单、快速、准确,可用于海产品、底泥、海水样品中扑草净的筛选和测定。  相似文献   

8.
建立了同时测定牛肉中5种磺胺类药物残留量的快速溶剂萃取-基质固相分散-高效液相色谱分析方法。通过优化样品处理条件,确定选取1.0g牛肉样品与3.0g弗罗里硅土混合,以乙腈为萃取剂在120℃、10MPa条件下用快速溶剂萃取仪提取样品中的磺胺。采用UltimateXB-C18色谱柱(4.6mm×250mm×5μm)分离,乙腈-3%乙酸溶液(体积比25∶75)为流动相,流速1.0mL/min,柱温为30℃,在紫外检测波长268nm条件下进样10μL。5种磺胺类药物在0.5~10.0mg/kg范围内线性关系良好(r≥0.9995),检出限为0.011~0.030mg/kg,加标回收率为89%~109%,相对标准偏差(n=5)为0.5%~4.3%。  相似文献   

9.
高效液相色谱法测定生物检材中毒鼠强   总被引:1,自引:0,他引:1  
建立了生物检材样品中微量毒鼠强的高效液相色谱法.生物检材样品经用乙酸乙酯提取,在优化的色谱条件下,以ZORBAX Eclipse XDB-C8>(4.6 mm×150 mm,5μm)为分离柱,乙腈-水(15 85,体积比)为流动相,在220 nm波长下进行检测;方法的线性范围为5~500μg·L-1,相关系数为0.999 9,方法的检出限(S/N=3)为0.5μg·kg-1,生物检材样品(包括血浆、胃内容物、肝、心)加标平均回收率在92.3~98.5%之间.相对标准偏差为2.67%~4.53%.  相似文献   

10.
高效液相色谱法测定环氧树脂粘接剂中的双酚A   总被引:1,自引:0,他引:1  
建立了进出口建筑用环氧树脂粘接剂中双酚A的高效液相色谱-荧光检测法。对提取方法和色谱条件进行了研究,结果表明采用乙醇超声提取样品15min可获得良好的提取效果。以乙腈和水为流动相,采用梯度洗脱可消除样品的基质干扰。方法对环氧树脂粘接剂中双酚A的定量限(LOQ)为0.5 mg/kg,在2~4000 ng/mL范围内,线性相关系数为0.9996。在5个添加水平下回收率在89.1%~100.8%之间。  相似文献   

11.
采用正己烷作萃取溶剂提取并富集水样中有机氯农药(OCP's)和多氯联苯(PCB's),所得提取液经浓缩至约0.5mL并定容至1.0mL后,用气相色谱法-电子捕获检测器测定水中有机氯农药和多氯联苯。采用Rtx-5MS和Rtx-1701双柱法根据与标准物质的保留时间相对比进行定性分析;采用Rtx-5MS柱对被测组分按外标法进行定量分析。结果表明:各种农药质量浓度均在0.5~40μg·L~(-1)范围内与峰面积呈线性关系。有机氯农药和多氯联苯的检出限(3s)在0.001 1~0.004 7μg·L~(-1)之间。用标准加入法测得其回收率在83.3%~112.1%之间,相对标准偏差(n=7)在4.4%~9.4%之间。  相似文献   

12.
经粉碎的橡胶样品用正己烷及丙酮(1+1)混合溶剂萃取,所得萃取液氮吹至近干后,加正己烷溶解残渣,将溶液经硅胶固相萃取柱净化,吸附于柱上的六溴环十二烷用正己烷-二氯甲烷(1+1)溶液淋洗,洗出液吹氮至近干,用乙腈溶解并用高效液相色谱法测定。选用Zorbax EclipseXDB-C18色谱柱作固定相,用水-乙腈(15+85)溶液作流动相,紫外检测器测定波长为210nm。方法的检出限(3S/N)为1.5mg.kg-1。方法用于橡胶制品中六溴环十二烷的测定,回收率和测定值的相对标准偏差(n=7)分别在83.1%~94.3%和3.6%~6.4%之间。  相似文献   

13.
We have previously described the use of a tandem simplified multilayer silica gel-activated carbon dispersed silica gel (TS-ML-AC) column for the cleanup of blood samples for the analysis of 29 hazardous organochlorine compounds (OCs)--the 17 major polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/DFs) and 4 non-ortho- and 8 mono-ortho-polychlorinated biphenyls (PCBs). We noted that the performance of the activated carbon-silica gel (ACS) column (lower column) varied with the lot number of the ACS. In this study, we compared the elution profiles of OCs eluted on 5 ACS columns, each with a different ACS lot number, and found that only mono-ortho-PCBs #114 and #123 were affected by lot number. The problem was that the 50 ml of n-hexane required to elute all the OCs from the simplified multilayer silica gel (MLS) column (upper column) into the AC column (lower column) also eluted varying amounts of PCBs #114 and #123 from the ACS column by ACS lot number. Although we could prevent PCBs #114 and #123 from being eluted from the ACS column by reducing the n-hexane volume to 10 ml, this volume was not sufficient to elute all the OCs from the MLS column. We solved this by separating the two columns; the sample solution was eluted with 50 ml of n-hexane from the MLS column, this eluate was concentrated to about 0.3 ml using a rotary evaporator, and then the concentrated solution was cleaned up on the ACS column. The recovery rates of #114 and #123 from blood samples were above 70% and the relative standard deviations of their concentration were below 10%, irrespective of the lot number, compared with recovery rates of 45-79% for #114 and 59-89% for #123, and relative standard deviations of their concentration above 15% when 50 ml of n-hexane was run through the tandem column. Our modified method affords reliable and reproducible cleanup of blood samples for analysis of 29 OCs, irrespective of the ACS lot number.  相似文献   

14.
建立了一种用于各种动物源性食品中氯霉素残留量的气相色谱-负化学离子源质谱(GC-MS/NCI)检测方法。以氘代氯霉素(D5-CAP)为内标物,用乙酸乙酯对各类样品中的氯霉素进行提取,用正己烷和40 g/L NaCl溶液液液分配除脂肪,基质复杂的样品再用Oasi HLB固相萃取柱净化,经硅烷化衍生后由GC-MS/NCI在选择离子监测模式下进行测定。多数样品在0.2,0.5,1.0μg/kg3个添加水平下氯霉素的回收率处于87.8%和107.0%之间,相对标准偏差(RSD)不大于8.5%。方法在2.0~80.0μg/L范围内有良好的线性关系,基质复杂样品中氯霉素残留的检出限达到0.1μg/kg,基质简单样品的检测限可达0.05μg/kg。方法适合各种动物源性食品中氯霉素残留量的确证分析。  相似文献   

15.
用符合ISO 30008标准要求的吸烟机按标准条件抽吸卷烟样品,抽吸完毕后,取下滤嘴,用乙酸乙酯-环己烷(1+1)混合溶剂超声提取30min。将提取液经无水硫酸钠干燥后旋转蒸至近干,残渣溶于正己烷2mL中,所得溶液经石墨炭黑小柱进行净化。小柱用丙酮-正己烷(2+8)混合溶剂淋洗2次,收集洗脱液,旋转蒸发浓缩后,将溶液用上述混合溶剂定容至1.5mL,供气相色谱分析,采用Agilent HP-5色谱柱进行分离和电子捕集检测。测定了4种拟除虫菊酯,相对标准偏差(n=5)均小于6%,于20个滤嘴样品中加入相当于20μg的4种拟除虫菊酯混合标准溶液,回收率均大于92%。  相似文献   

16.
提出了气相色谱-质谱法测定塑料玩具中16种多环芳烃(PAH′s)含量的方法。样品经正己烷超声提取30min后,40℃水浴氮气吹干。用水、甲醇和正己烷-二氯甲烷(3+2)混合溶剂各5mL溶解残渣,过C18固相萃取柱净化,用正己烷-二氯甲烷(3+2)混合溶液洗脱,所得洗脱液过HP-5MS色谱柱分离,电子轰击离子源检测。16种多环芳烃的质量浓度在0.2~4.0mg·L-1范围内与其峰面积呈线性关系,方法的检出限(3S/N)在0.002~0.021mg·kg-1之间。以聚丙乙烯、聚乙烯、聚氯乙烯或丙烯腈-丁二烯-苯乙烯共聚物等4种材质的塑料玩具为基体,进行加标回收试验,回收率在79.6%~95.2%之间。  相似文献   

17.
Temperature gradient interaction chromatography (TGIC) is a powerful technique for molecular weight fractionation of polymers, in which the interaction strength is controlled by varying the column temperature. In the present paper, the effects of the sign of the temperature dependence of the retention and the direction of the temperature gradient (raising or lowering) on TGIC in the normal-phase mode were studied for the molecular weight fractionation of polystyrene samples in organic mobile phases. It was found that a positive temperature gradient was effective in the system consisting of amino-modified silica (NH(2)) column and the eluent mixture of tetrahydrofuran and n-hexane where retention decreased with increasing temperature. A negative temperature gradient was effective for the systems consisting of a bare-silica column//chloroform/n-hexane and NH(2)-column//chloroform/n-hexane, where retention increased with increasing temperature. Increasing retention with increasing temperature has been found, so far, only for a water-soluble polymer (PEO) in an aqueous mobile phase in RP-TGIC.  相似文献   

18.
提出了高效液相色谱-质谱法测定单、双季戊四醇油酸酯中单酯、双酯、三酯和四酯的含量。样品经正己烷-异丙醇(9+1)溶剂溶解后,以Lichrospher Si100-5色谱柱(4.6mm×250mm,5μm)为分离柱,以不同体积比的正己烷和异丙醇混合溶液为流动相梯度淋洗。采用总离子流图的峰面积归一化法对单、双季戊四醇油酸酯中单酯、双酯、三酯和四酯的含量进行定量,用质谱法做鉴别。  相似文献   

19.
A method to determine six organochlorine and three pyrethroid pesticides in grape, orange, tomato, carrot and green mustard based on solvent extraction followed by solid phase extraction (SPE) clean-up is described. The pesticides were spiked into the sample prior to analysis, extracted with ethyl acetate, evaporated and reconstituted with a solvent mixture of acetone:n-hexane (3:7). Three different sorbents (Strong Anion Exchanger/Primary Secondary Amine (SAX/PSA), Florisil and C18) were used for the clean-up step. Pesticides were eluted with 5mL of acetone:n-hexane (3:7, v/v) and determined by gas chromatography and electron-capture detection (GC-ECD). SAX/PSA was the sorbent, which provided chromatograms with less interference and the mean recoveries obtained were within 70-120% except for captafol. The captafol recoveries for grape were within acceptable range with C18 clean-up column.  相似文献   

20.
通过气相色谱-负化学离子源质谱技术建立了同时检测18种农药残留的分析方法. 样品经正己烷和丙酮混合溶剂及正己烷提取后, 用活性炭-中性氧化铝混合小柱净化, 再由气相色谱-负化学离子源质谱分时段选择离子监测技术进行测定. 一次进样就能得到18种农药残留结果;各农药在0.005、 0.01和0.02 mg/kg 3个添加水平的平均回收率在70.2%~115.3%之间, RSD<12%, 检出限为0.01~6 μg/kg, 方法可应用于8种植物性产品中的农残检测.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号