首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
试验发现:原子吸收光谱法(AAS)在442.7 Nm波长处测定钙时受到大于0.10 mg·L-1磷共存的干扰,使钙的测定结果偏低,而且此负偏差降低的幅度随磷浓度的增加而增大.试验还发现:当共存磷的量在0.1~6.0 mg·L-1之间时,钙测量值的负偏差幅度与磷浓度之间存在明显的相关性.应用反向传播人工神经网络(BP-ANN)及模拟退火两种计算法对上述非线性干扰效应进行了研究,并提出了在单一波长检测的条件下,钙、磷两元素的原子吸收光谱法同时测定,此法应用于循环水中钙、磷的同时测定.两元素的检测范围依次为0.08~10.0 mg·L-1及0.10~6.0 mg·L-1,测得其回收率分别为100.5%和98.0%.  相似文献   

2.
电感耦合等离子体原子发射光谱法(ICP-AES)应用于某些特殊试样(特别试液背景色泽很深或略带混浊者)中铬(Ⅵ)的测定.试样溶液中共存的铬(Ⅲ)及一些其他金属离子的干扰,借在PH 9.5的氨性溶液中以Fe(Ⅲ)离子作载体共沉淀分离予以消除,用ICP-AES法测定滤液中铬(Ⅳ).试验表明:铬(Ⅲ)共存量达100 mg·L-1时,经沉淀分离后不影响铬(Ⅵ)的测定,铬(Ⅵ)的回收率接近100%.此方法的检出限(3σ)为0.054 mg·L-1,应用所提出的方法测定了一种黄色油漆中在铬(Ⅲ)共存下的铬(Ⅵ),平行7次测定,相对标准偏差为1.3%.  相似文献   

3.
建立了用邻菲啰啉-Fe(Ⅱ)分光光度法测定头孢唑啉钠的方法 .头孢唑啉钠在0.10mol·L-1 NaOH溶液中,100℃水浴加热降解为含巯基的化合物.巯基化合物把Fe3+还原为Fe2+.加入邻菲啰啉显色,通过测定生成的橘红色配位化合物的吸光度间接测定头孢唑啉钠的含量.头孢唑啉钠浓度在0.02~40mg·L-1范围内呈现良好线性关系,线性回归方程A=0.043c(mg·L-1)-0.001,相关系数R=0.998 8,表观摩尔吸光系数ε=2.05×104 L·(mol·cm)-1,相对标准偏差RSD=1.27%,检测限(3σ/k)0.065mg·L-1.在此基础上,测定了市售头孢唑啉钠粉针剂的含量,回收率在99.17%~101.2%之间,结果令人满意.  相似文献   

4.
青霉胺的巯基具有还原性,可将Fe(Ⅲ)还原Fe(Ⅱ),Fe(Ⅱ)能与2,2′-联吡啶形成桔红色的配合物,其最大吸收波长为524nm,据此提出了分光光度法间接测定青霉胺药片中青霉胺含量的方法。优化的试验条件如下:①pH 4.5的0.2 mol·L-1乙酸-乙酸钠缓冲溶液用量为2.5mL;②0.2g·L-1氯化铁溶液用量为2mL;③1g·L-1 2,2′-联吡啶溶液用量为2.5mL;④显色时间为5min。青霉胺的质量浓度在26mg·L-1以内间接地与吸光度呈线性关系,检出限(3S/N)为0.01mg·L-1。采用此法测定了青霉胺药片中青霉胺含量,所得测定值与标示量相符,测定值的相对标准偏差(n=5)为2.4%。  相似文献   

5.
在低温加热的条件下,油样用浓硝酸消化,所得试液中加入适量Triton X-100及Tween 80使乳化从而得到均匀的透明或半透明的呈橙黄色或黄绿色的试样溶液,供火焰原子吸收光谱法(FAAS)测定钙及锌.对非完全消化所用的酸和乳化剂的选择和FAAS测定中的化学干扰、背景干扰以及空白溶液及试样溶液粘度的一致性等分析务件进行了试验和优化.钙及锌两元素的线性范围依次为0~12 mg·L-1和0~1.6 mg·L-1,检出限(3σ/s)依次为0.14 mg·L-1及0.018 mg·L-1.此方法应用于润滑油实样分析,所得两元素分析结果的RSD(n=6)值均小于5%,回收率均在100.0%~102.1%之间.  相似文献   

6.
采用噻唑蓝(MTT)法、碱性磷酸酶(ALP)比活性测定、油红O染色和茜素红染色及定量分析,研究了不同浓度的Fe3+和Fe2+对原代培养的成骨细胞增殖、分化及矿化功能的影响.结果表明:浓度为1×10-9~1×10-4 mol·L-1的Fe3+和Fe2+促进成骨细胞增殖,但是在较高浓度1×10-3 mol·L-1时,它们则抑制成骨细胞增殖.与成骨细胞作用48 h,浓度为1×10-8~1×10-4 mol·L-1的Fe3+和Fe2+抑制其分化,但在较低的浓度1×10-9 mol·L-1时则对其分化没有影响:进一步延长作用时间为72 h,Fe3+对成骨细胞分化没有影响,除1×10-6mol·L-1浓度的Fe2+促进成骨细胞分化外,其他浓度的Fe2+则抑制其分化;测试浓度下的Fe3+对成骨细胞向脂肪细胞的横向分化表现为抑制或没有影响,而Fe2+的影响则依赖于浓度和作用时间.在1×10-8~1×10-5mol·L-1浓度范围内,Fe3+和Fe2+对矿化结节的影响表现出相反的效应.在较高浓度(1×10-4mol·L-1)下,它们促进矿化节结的形成,而在较低浓度(1×10-9mol·L-1)下,Fe3+抑制矿化节结的形成,Fe2+则没有影响.结果提示:浓度.作用时间和铁离子的价态都是影响Fe3+和Fe2+生物效应(从毒性到活性,从损伤到保护,从上调到下调)转变的关键因素.  相似文献   

7.
建立了液-液-液微萃取与高效液相色谱联用技术快速分析尿样中麻黄碱和可待因的方法.优化得到的最佳萃取条件:萃取溶剂为80μL苯,接受相为1.0μL 0.2 mol·L-1的HCI,搅拌速率为80 r·min-1,萃取时间为40 min.在该条件下.获得了高的富集因子(大于117倍).方法的线性范围为麻黄碱0.05-10mg·L-1,可待因0.10-10 mg·L-1,相关系数(r)大于0.997,检出限分别为0.025 mg·L-1和0.05 mg·L-1,相对标准偏差小于9%.该方法能有效地去除尿样中的干扰物质,有机溶剂消耗少,萃取效率高,可同时测定尿样中麻黄碱和可待因.  相似文献   

8.
ICP-AES测定铀污染土壤植物中铀的研究   总被引:2,自引:0,他引:2  
采用电感耦合等离子体发射光谱(ICP-AES)对铀污染土壤植物中铀的测定方法进行了研究.在λU385.958 nm处,选择了仪器的最佳工作条件,考察了酸度和常见共存元素对测定的干扰情况,并且对比了干灰化消解和湿式消解对测定的影响.研究发现2%硝酸溶液为最佳介质,干扰离子对测定没有显著影响,干灰化消解比湿式消解得彻底.在选定条件下,方法检出限为0.18 mg·L-1,测定下限为0.61 mg·L-1,5.0000 mg·L-1的铀标准溶液的相对标准偏差RSD(n=10)为0.81%,方法回收率为96.2%~106.2%.该方法操作简单,快速.结果表明,用ICP-AES测定铀污染土壤植物样品中的铀是可行的.  相似文献   

9.
移取25.00mL样品,用水定容至100mL,用0.2μm水系滤膜过滤后制得样品溶液,采用BEH Amide色谱柱(3.0mm×150mm,1.7μm)分离,以0.010mol·L-1乙酸铵乙腈溶液-0.010mol·L-1乙酸铵水溶液(体积比为70∶30)为流动相,流量为0.40mL·min-1,采用蒸发光散射检测器。干扰试验表明:甲基磺酸盐镀锡电镀液中其他共存组分对对苯二酚的测定均没有干扰。对苯二酚质量浓度在10.0~100.0mg·L-1内,其质量浓度的对数与其峰面积的对数呈线性关系,检出限(3S/N)为2.21mg·L-1。方法用于测定甲基磺酸盐镀锡电镀液样品中的对苯二酚,测定值的相对标准偏差(n=11)为0.79%~1.2%,加标回收率为99.2%~102%,。按照甲基磺酸盐镀锡电镀液配方配制合成样品,采用试验方法对对苯二酚进行测定,测定值与理论值相符。  相似文献   

10.
比浊法快速测定电解锌废液中微量氯   总被引:6,自引:1,他引:6  
电解锌生产流程是封闭循环系统,从锌矿至电解废液,氯离子的检测必不可少。氯离子主要源于矿石及辅料中可溶性氯化物,并不断累积,当流程中氯离子超过100mg·L-1时,就会引起烧极板锌片剥离困难等生产不利因素,废液中的锰(Ⅶ)则来自净化工序,含量一般在10~20g·L-1。用比浊法测定氯离子时产生严重背景干扰,导致氯离子结果偏高。消除锰(Ⅶ)的背景干扰,是采用比浊法快速测定电解锌废液中微量氯的关键。经试验用硫酸亚铁将七价锰还原至无色低价锰,不仅空白值低,还原效果好,30g·L-1硫酸亚铁溶液0.3ml,可还原100mg七价锰至低价,试样加标回收…  相似文献   

11.
Kinetics of complexation reaction of Co2+ with 2-benzoylpyridine-4-phenyl-3-thiosemicarbazone (BPPT)was spectrophotometrically examined at 421 nm. The ligand that is developed for a simple kinetic-spectrophotometric determination of Co2+ is based on 1:2 complex formation between Co2+ and BPPT. The complexation reaction was carried out in ethanol-water medium at 25 ℃. Kinetic and activation parameters of the complexation reaction were calculated, and the rate equation and the reaction mechanism were proposed. The calibration graph is linear in the concentration range of 0.10~2.91 mg·L-1 for the tangent method. The species that caused interference were investigated.  相似文献   

12.
脂质体免疫传感器的制备及其应用于测定尿液中2,4-D的量   总被引:1,自引:0,他引:1  
将4种溶质(以10∶10∶1∶1质量比混合的DPPC、胆固醇、DPPG及DPPE)的混合物22mg,溶于4mL氯仿-异丙醚-甲醇(6+6+1)混合溶剂中。向此溶液中加入0.15mol·L-1亚铁氰化钾溶液1mL,于45℃超声涡旋5min使其包埋于脂质体中。将此脂质体包埋的亚铁氰化钾溶液1mL,通过戊二醛(0.7+99.3)溶液2mL的作用,与200μL 2,4-D免抗体溶液(10.53g.L-1)交联。另将自制MWNT′s修饰的石墨电极插入0.05mol·L-1脂质体-抗体-吡咯溶液中,用循环伏安法在0~0.75V电位区间扫描10次,扫描速率为50mV.s-1。由此制成的免疫传感器应用于测定尿样中2,4-D含量,其线性范围为0.05~2.5 mg·L-1之间,检出限(3S/N)为15.4μg·L-1。  相似文献   

13.
To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.  相似文献   

14.
建立了同时测定牛奶中克伦特罗、氯霉素和己烯雌酚残留量的同位素稀释超高效液相色谱-串联质谱(UPLC-MS/MS)分析方法.牛奶样品无需蛋白沉淀,直接经HLB小柱净化及水和正己烷淋洗,由乙酸乙酯洗脱后进行分析.采用Acquity UPLC(○R)BEH C18色谱柱进行分离,以乙酸铵溶液-乙腈作为流动相进行梯度洗脱,MR...  相似文献   

15.
提出了离子色谱法同时测定卷烟纸中钠、钾、镁和钙含量的方法。卷烟纸试样经硝酸-过氧化氢-氢氟酸微波消解,以IonPac CS16阳离子交换柱为固定相,用0.027 mol.L-1甲烷磺酸溶液作流动相。钠、钾、镁和钙4种元素在30 min内可完全分离;各离子的检出限(3S/N)分别为13,15,8.1,97 mg.L-1。方法的加标回收率在100.9%~108.8%之间,测定值的相对标准偏差(n=5)在0.87%~3.4%之间。  相似文献   

16.
应用高效液相色谱法测定了染发剂中2-硝基-p-苯二胺的含量。样品用乙醇-水(1+1)混合溶液提取后,经水系C18色谱柱分离,以(A)10mol·L-1柠檬酸缓冲溶液-10mol·L-1辛烷磺酸钠溶液(pH 2.6)与(B)乙腈以体积比75比25组成的混合溶液为流动相进行等度洗脱,用二极管阵列检测器于410nm检测。2-硝基-p-苯二胺的线性范围为2.4~240mg·L-1,检出限(3S/N)为0.7mg·L-1。以染发剂样品为基体,进行加标回收试验,回收率在90.4%~99.4%之间,相对标准偏差(n=6)在0.35%~3.0%之间。  相似文献   

17.
低压离子分离-化学发光在线检测过渡金属离子   总被引:6,自引:1,他引:6  
周光明  刘玲  杨光明  张新申 《色谱》2002,20(3):265-268
 研究了低压离子 (LPIC)分离 柱后鲁米诺化学发光 (CL)检测方法 ,并分离测定了Cu2 + ,Co2 + ,Cr3 + ,Fe2 + ,Mn2 + 等 5种过渡金属离子。以草酸 柠檬酸混合溶液作为洗脱液 ,Luminol H2 O2 Mn + 作为化学发光检测体系 ,对过渡金属离子进行在线检测。测定的线性范围分别为 (mg·L-1) :Co2 + ,0 0 0 1~ 0 .1;Cu2 + ,0 1~ 6 ;Mn2 + ,0 0 6~ 4 ;Fe2 + ,0 0 3~ 5 ;Cr3 + ,0 0 2 5~ 1。检测限分别为 (μg·L-1) :Co2 + ,0 85 ;Cu2 + ,85 ;Mn2 + ,4 2 ;Fe2 + ,2 1;Cr3 + ,2 0。  相似文献   

18.
The ability of a quadrupole-based ICP-MS with an octopole collision cell to obtain precise and accurate measurements of isotope ratios of magnesium, calcium and potassium was evaluated. Hydrogen and helium were used as collision/reaction gases for ICP-MS isotope ratio measurements of calcium and potassium in order to avoid isobaric interference with the analyte ions from (mainly) argon ions 40Ar+ and argon hydride ions 40Ar1H+. Mass discrimination factors determined for the isotope ratios 25Mg/24Mg, 40Ca/44Ca and 39K/41K under optimized experimental conditions varied between 0.044 and 0.075. The measurement precisions for 25Mg/24Mg, 40Ca/44Ca and 39K/41K were found to be 0.09%, 0.43% and 1.4%, respectively. This analytical method that uses ICP-QMS with a collision cell to obtain isotope ratio measurements of magnesium, calcium and potassium was used in routine mode to characterize biological samples (nutrient solution and small amounts of digested plant samples). The mass spectrometric technique was employed to study the dynamics of nutrient uptake and translocation in barley plants at different root temperatures (10 °C and 20 °C) using enriched stable isotopes (25Mg, 44Ca and 41K) as tracers. For instance, the mass spectrometric results of tracer experiments demonstrated enhanced 25Mg and 44Ca uptake and translocation into shoots at a root temperature of 20 °C 24 h after isotope spiking. In contrast, results obtained from 41K tracer experiments showed the highest 41K contents in plants spiked at a root temperature of 10 °C.  相似文献   

19.
阻抑催化动力学光度法测定板栗罐头中痕量EDTA   总被引:1,自引:0,他引:1  
在硫酸介质中,Fe(Ⅲ)对过氧化氢氧化中性红的褪色反应具有强的催化作用,EDTA对上述指示反应具有灵敏的阻抑作用,从而提出了一种阻抑催化动力学光度法测定板栗罐头中痕量EDTA的方法。优化的试验条件如下:①过氧化氢用量为1.0mL;②0.1g.L-1中性红溶液用量1.0mL;③50.0mg.L-1 Fe(Ⅲ)溶液用量为0.12mL;④反应温度为沸水浴;⑤反应时间为10min。EDTA的质量浓度在900μg.L-1以内与ΔA呈线性关系,检出限(3s/k)为8μg.L-1。方法用于板栗罐头中EDTA的测定,测定值的相对标准偏差(n=6)小于3.0%,加标回收率为93.0%~96.0%。  相似文献   

20.
魔芋精粉和虾样品经水蒸气蒸馏除去杂质的干扰,在密闭容器中对样品进行酸化,在氮气流的保护下蒸馏,用甲醛溶液吸收释放出的二氧化硫,提出了离子色谱法测定样品中亚硫酸盐含量的方法。以IonPacAS9-HC色谱柱,以8mmol.L-1碳酸钠-2.5mmol.L-1氢氧化钠溶液为淋洗液等度洗脱,用电导检测器测定。亚硫酸盐的质量浓度在6.0mg.L-1范围内与其峰面积呈线性关系,方法的检出限(3S/N)为4.0mg.kg-1。方法用于魔芋精粉和虾样品分析,回收率在88.1%~98.3%之间,测定值的相对标准偏差(n=8)在1.4%~6.6%之间。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号