首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   0篇
化学   25篇
物理学   9篇
  2018年   1篇
  2016年   1篇
  2014年   1篇
  2013年   1篇
  2011年   1篇
  2008年   2篇
  2007年   2篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2002年   1篇
  2001年   7篇
  2000年   3篇
  1999年   4篇
  1997年   4篇
  1995年   1篇
排序方式: 共有34条查询结果,搜索用时 15 毫秒
1.
A computer program is described, which calculates the induced activities of isotopes after irradiation in a known neutron field, thermal and epithermal neutron fluxes from the measured induced activities and from nuclear data of 2–4 monitor nuclides as well as the element concentrations in samples irradiated together with the monitors. The program was developed for operation in Windows 3.1 (or higher). The application of the program for neutron activation analysis allows to simplify the experimental procedure and to reduce the time. The program was tested by measuring different types of standard reference materials at the FRJ-2 (Research Centre, Jülich, Germany) and Triga (University Mainz, Germany) reactors. Comparison of neutron flux parameters calculated by this program with those calculated by a VAX program developed at the Research Centre, Jülich was done. The results of testing seem to be satisfactory.  相似文献   
2.
 As a result of the Chernobyl nuclear power plant accident in 1986, thyroid pathologies occurred among children in some regions of Belarus. Besides the irradiation of children’s thyroids by radioactive iodine and caesium nuclides, toxic elements from fallout are a direct risk to health. Inductively coupled plasma quadrupole-based mass spectrometry was used for multielement determination in small amounts (1–10 mg) of thyroid tissue samples obtained during thyroid operations in Minsk hospitals. The accuracy of the applied analytical technique for small biological sample amounts was checked using NIST Standard Reference Material oyster tissue (SRM 1566b) and by comparison with independent analytical methods, such as neutron activation analysis. Almost all essential elements as well as a number of toxic elements such as Cd, Pb, Hg, U etc. were determined in a multitude of human and animal thyroid tissues (up to 1 mg sample material) by quadrupole-based ICP-MS using micronebulization. In general, the thyroid tissue affected by pathology is characterized by higher calcium content. Some other elements, among them Fe, Mn, V, As, Cr, Ni, Pb, U, Ba, Sb, were also accumulated in such tissue. The results obtained will be used as initial material for further specific studies of the role of particular elements in thyroid pathology development. Received November 15, 1999. Revision March 15, 2000.  相似文献   
3.
Severe radiation damages with the following substitution of connective tissue are the effect of high doses in microvolumes of the thyroid. Calcium, strontium and uranium deposited into these sections was more as compared to a normal tissue of the thyroid. An estimation of the microdistribution of fissile radionuclides was carried out using the method of fragmental radiography. The analysis of tracks done visually using a microscope magnification of 300 revealed the local density of fission fragments up to 103 mm−2. The irradiation of the surrounded cells which contain the hidden genetic damages, initiated by radioiodine, does not exclude their possible promoter role in thyroid cancerogenesis.  相似文献   
4.
Peńkin  M.  Boulyga  S.  Dabbs  B.  Fischer  D.  Humphrey  M.  Kochetkov  A.  Koepf  A.  Sturm  M. 《Journal of Radioanalytical and Nuclear Chemistry》2018,316(2):791-798
Journal of Radioanalytical and Nuclear Chemistry - Reference information on isotopic composition of various uranium materials, determined with high accuracy and precision, is of essential value for...  相似文献   
5.
To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP–MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP–MS (“Platform ICP”, Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2 + was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 μg L–1 solution nebulized by means of a USN and for 78Se/80Se in 100 μg L–1 solution nebulized by means of a Meinhard nebulizer. Received: 15 December 2000 / Revised: 26 March 2001 / Accepted: 27 March 2001  相似文献   
6.
This paper describes an analytical procedure for determining the stoichiometry of BaxSr1–xTiO3 perovskite layers using inductively coupled plasma mass spectrometry (ICP-MS). The analytical results of mass spectrometry measurements are compared to those of X-ray fluorescence analysis (XRF). The performance and the limits of solid-state mass spectrometry analytical methods for the surface analysis of thin BaxSr1–xTiO3 perovskite layers – sputtered neutral mass spectrometry (SNMS) – are investigated and discussed.  相似文献   
7.
This paper presents the application of a multicollector inductively coupled plasma mass spectrometer (MC–ICP–MS)—a Nu Plasma HR—equipped with three ion-counting multipliers and coupled to a laser ablation system (LA) for the rapid and sensitive determination of the 235U/238U, 236U/238U, 145Nd/143Nd, 146Nd/143Nd, 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios in microsamples collected in the vicinity of Chernobyl. Microsamples with dimensions ranging from a hundred μm to about 1 mm and with surface alpha activities of 3–38 mBq were first identified using nuclear track radiography. U, Nd and Ru isotope systems were then measured sequentially for the same microsample by LA–MC–ICP–MS. The application of a zoom ion optic for aligning the ion beams into the ion counters allows fast switching between different isotope systems, which enables all of the abovementioned isotope ratios to be measured for the same microsample within a total analysis time of 15–20 min (excluding MC–ICP–MS optimization and calibration). The 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios were measured for four microsamples and were found to be significantly lower than the natural ratios, indicating that the microsamples were contaminated with the corresponding fission products (Ru and Tc). A slight depletion in 146Nd of about 3–5% was observed in the contaminated samples, but the Nd isotopic ratios measured in the contaminated samples coincided with natural isotopic composition within the measurement uncertainty, as most of the Nd in the analyzed samples originates from the natural soil load of this element. The 235U/238U and 236U/238U isotope ratios were the most sensitive indicators of irradiated uranium. The present work yielded a significant variation in uranium isotope ratios in microsamples, in contrast with previously published results from the bulk analysis of contaminated samples originating from the vicinity of Chernobyl. Thus, the 235U/238U ratios measured in ten microsamples varied in the range from 0.0073 (corresponding to the natural uranium isotopic composition) to 0.023 (corresponding to initial 235U enrichment in reactor fuel). An inverse correlation was observed between the 236U/238U and 235U/238U isotope ratios, except in the case of one sample with natural uranium. The heterogeneity of the uranium isotope composition is attributed to the different burn-up grades of uranium in the fuel rods from which the microsamples originated. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   
8.
Determination of phosphorus in small amounts of protein samples by ICP–MS   总被引:3,自引:0,他引:3  
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.  相似文献   
9.
To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.  相似文献   
10.
Nuclear track radiography was applied to identify aerosol “hot” particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the -activity of “hot” particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and (γ,f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of “hot” particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by 235U, 239Pu and 241Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5×10−6 Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical image of the SSNTD surface obtained through a video camera and the determination of size and activity of “hot” particles.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏