共查询到18条相似文献,搜索用时 171 毫秒
1.
建立氢化物发生–原子荧光光度法测定食品和食品添加剂中砷、汞和铅元素的方法。对茶叶、方便面、精料与二氧化硅样品的前处理方法进行了研究,讨论了酸介质与酸度、还原剂浓度、铁氰化钾与草酸浓度等因素对样品测定的影响。当还原剂质量浓度为20 g/L、载流酸度为5%、铁氰化钾和草酸质量浓度分别为4 g/L和2 g/L时,砷、汞和铅的方法检出限分别为0.024,0.008,0.066μg/L,方法的回收率为85%~105%,测量结果的相对标准偏差分别为0.7%,0.7%,1.8%。该方法简便、快速、结果准确可靠,能满足食品和食品添加剂中砷、汞、铅的测定。 相似文献
2.
3.
建立了以分散液液微萃取技术作为分离富集手段,以测汞仪分析水产品中的甲基汞的方法。以测汞仪直接测定样品中总汞,并用差减法计算出无机汞的含量。实验优化了分散液相微萃取的条件。实验表明,以二氯甲烷为萃取剂,乙醇为分散剂,二者体积比为1:5,HCl浓度为1 mol/L,NaCl浓度为120 g/L时,可以得到较为理想的结果。本方法的动态线性范围为0.2~20μg/L,检出限为0.10μg/L,相对标准偏差6.0%,富集倍数为8。仪器测定总汞的检出限为0.1 μg/kg,线性范围0.2~50μg/kg,相对标准偏差2.4%。本方法简单、快速,溶剂消耗量少。以标准参考物质验证本方法的准确性,其测定结果与标准值吻合较好。将本方法应用于实际水产制品的分析,得到较满意的结果。 相似文献
4.
WM-10型水汞测量装置-原子荧光光谱仪联用测定海水中痕量总汞 总被引:1,自引:0,他引:1
采用WM-10型水汞测量装置与原子荧光光谱仪联用测定海水中的痕量总汞,海水中总汞的检测限为3.4 ng/L、线性范围为0.005~0.100 μg/L (n=5,r=0.9995);无汞海水基底加0.0100 μg/L汞标的水样,测定平均值为0.0105 μg/L,相对标准偏差为11.8% (n=12);无汞海水基底加标平均回收率为102.8%.采用该法与EPA 1631方法分别测定了12个实际海水样,两种方法结果的相对百分偏差为0.3%~17.6%.方法可应用于海水中痕量总汞的测定. 相似文献
5.
采用石墨消解法对土壤样品进行预处理,用原子荧光光度法测定样品中汞和砷的含量。汞的质量浓度c在0.00~1.00μg/L范围内与荧光强度I线性相关,回归方程为I=849.47c–22.356,相关系数r2=0.999 9,检出限为0.001 8μg/g。砷的质量浓度在0.00~10.00μg/L范围内与荧光强度线性相关,回归方程为I=107.22c–28.994,相关系数r2=0.999 9,检出限为0.009 9μg/g。实际土壤样品5次平行测定汞和砷的相对标准偏差分别为6.2%~15.2%,0.8%~9.9%,用本法对黄土标准样品进行测定,测定结果在标准值允许范围内。 相似文献
6.
为建立微波消解-原子荧光光谱法同时测定鱼体中砷和汞的测定方法,采用微波消解方法,双道原子荧光光谱法同时测定了鱼体中砷和汞的含量。结果表明,砷与汞的线性范围分别为0.2~2.0μg/L,0.0~50.0μg/L;相关系数分别为r=0.999 8和r=0.999 5;砷回收率为96.5%~101.5%之间,相对标准偏差(n=11)为1.22%,检出限为0.004 2μg/L;汞回收率为98.6%~103.0%,相对标准偏差(n=11)为0.67%,检出限为0.009 6μg/L。用该法测定鱼类中砷和汞,方法灵敏度高、操作简便快速、结果准确可靠。 相似文献
7.
高效液相色谱与原子荧光光谱联用分析汞化合物形态的研究 总被引:15,自引:2,他引:15
建立了高效液相色谱与原子荧光光谱联用测定汞化合物形态的分析方法。实验对淋洗液组分浓度、氧化剂和还原剂浓度、载气流速及紫外消解管长度等操作条件进行了优化,获得了令人满意的分析结果。在优化的分离检测条件下,20μg/L的汞化合物标准溶液平行7次进样分析,甲基汞、无机汞和乙基汞的色谱峰高的相对标准偏差(RSD)分别为2.0%、2.9%和2.4%;3种汞化合物的线性范围为10~1000μg/L,25μL进样检出限分别为3、2和4μg/L。用建立的方法测定了脉红螺样品中甲基汞的含量,甲基汞和乙基汞的加标回收率分别为90%和92%。 相似文献
8.
使用XGY-6080型双通道原子荧光光度计,同时测定饮用水中的砷和汞。在最佳仪器工作条件下,砷和汞的检出限分别为0.0273μg/L、0.0034μg/L,测定结果的相对标准偏差为1.09%~3.34%(n=7),砷和汞的加标回收率分别为96.59%~103.97%和96.78%~98.95%。 相似文献
9.
艾明 《中国无机分析化学》2013,3(1):74-76
研究了采用氢化物发生-原子吸收光谱法测定食品中痕量汞的方法,通过采用氢化物发生器,选择合适浓度的载流和硼氢化钾,获得了较为满意的分析结果。在测定汞含量5~20μg/kg的食品标准样品时,测试结果相对标准偏差RSD为2.2%~3.7%,回收率为84.9%~97.5%,检出限为0.2μg/L,完全满足食品行业汞元素痕量检测要求,操作简便、快速。 相似文献
10.
密闭微波消解-冷原子荧光光谱法测定蔬菜中的痕量汞 总被引:1,自引:0,他引:1
采用硝酸和过氧化氢体系,密闭微波消解,冷原子荧光光谱法测定蔬菜中的痕量汞,选择0.3g/L硼氢化钾溶液为还原剂,硝酸溶液(1 99)为酸介质。测定结果表明汞浓度在0~1μg/L范围线性良好,相关系数大于0.9990,汞的加标回收率为90.2%~99.6%,测定结果的相对标准偏差均小于4%,检出限为0.0058μg/L。 相似文献
11.
12.
采用王水-过氧化氢预氧化水浴热浸提处理样品,应用原子荧光光谱法快速检测原生中草药中痕量汞.其方法回收率在98.6%~105.4%之间,相对标准偏差在3.0%~7.4%之间,标准系列质量浓度在0.000~6.000μg/L范围内线性关系良好,相关系数为0.999 9,一元线性回归方程为:IF=301.512C+1.235,方法检出限达到0.021 6μg/L.试验证实,方法具有简便、快速、灵敏度高、取样量少等优点,为原生中草药中痕量汞的检测提供了有效的分析方法. 相似文献
13.
14.
Flame-heated tubes are widespread in flame-AAS, mainly for the determination of hydride-forming elements. Instead of the introduction of gaseous compounds liquids can also be introduced continuously in such an absorption cell. With the aid of an HPLC pump the liquid is forced through a very fine nozzle, generating an aerosol beam less than 0.5?mm in diameter. This beam travels a distance of 10?cm as a “free-flying aerosol jet” into the sample introduction hole of a metal tube furnace placed in the flame. Both introduction of the entire sample and the long residence time lead to a considerable improvement in power of detection. The detection limit for 100 μL samples amounts to 7 μg/L (Pb) and to 0. 2 μg/L (Cd), which means an increase in power of detection of between one and two orders of magnitude compared to conventional flame-AAS. The relative standard deviation (100 μL sample volume, N = 10) was found to be 1.3% (signal area) for 600 μg/L Pb and to be 1.5% (signal-area) for 15 μg/L Cd. RSD values from measurements in peak-height amounted to 2.2% (Pb) and to 1.7% (Cd). 相似文献
15.
建立了密闭罐溶样–氢化物发生–原子荧光光谱法测定中药中痕量汞和砷的分析方法。采用密闭罐溶解复杂基体中药样品,进行易挥发元素分析的样品前处理,技术简单,快速,能耗低。汞和砷的质量浓度分别在0~10μg/L和0~200μg/L范围内与荧光强度成线性关系,线性相关系数均大于0.99。汞、砷的检出限分别为0.014,0.086μg/L;测定结果的相对标准偏差不大于4.67%(n=5);加标回收率分别为99.0%~106.4%,95.2%~101.7%。该方法操作简便,可用于中药中汞、砷元素的质量控制。 相似文献
16.
以硼氢化钾代替二氯化锡作还原剂,用气相分子吸收光谱仪代替测汞仪,冷原子吸收法测定了水中总汞,按有关规范的原则和方法评定了其测量不确定度。结果表明,检出限为0.005μg/L,精密度RSD为1.O%,加标回收率为99.1%~103.1%,测定海洋局外控样和IERM测量审核样的结果良好,测定汞标样的相对误差为1.7%。此法测定样品的扩展不确定度为3.5%。 相似文献
17.
18.
《中国化学快报》2020,31(10):2814-2818
An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy (SAGD-AES) coupled with hydride generation (HG) was first investigated. In this method, the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph. A thorough parametric evaluation of the HG and SAGD system was performed, including the type and concentration of carrier acid, He flow rate, concentrations of NaBH4, discharge current and discharge gap. Under optimal operating conditions, the detection limit for Hg2+ achieved 0.03 μg/L, with a relative standard deviation of 1.1% at the Hg2+ concentration of 5 μg/L. Moreover, the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L. The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101b (human hair), GBW10029 (fish), soil and rice samples. The results showed good agreement with the certified values and values from direct mercury analyzer (DMA). 相似文献