首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
XIE Yu-Guang  LI Wei-Dong  LIANG Yu-Tie  YOU Zheng-Yun  MAO Ya-Jun  ZHANG Jia-Wen  BIAN Jian-Ming  CAO Guo-Fu  CAO Xue-Xiang  CHEN Shen-Jian  DENG Zi-Yan  FU Cheng-Dong  GAO Yuan-Ning  HE Kang-Lin  HE Miao  HUA Chun-Fei  HUANG Bin  HUANG Xing-Wao  JI Xiao-Bin  LI Fei  LI Hai-Bo  LIU Chun-Xiu  LIU Huai-Min  LIU Qiu-Guang  LIU Suo  LIU Ying-Jie  MA Qiu-Mei  MA Xiang  MAO Ze-Pu  MO Xiao-Hu  PAN Ming-Hua  PANG Cai-Ying  PING Rong-Gang  QIN Ya-Hong  QIU Jin-Fa  SUN Sheng-Sen  SUN Yong-Zhao  WANG Ji-Ke  WANG Liang-Liang  WEN Shuo-Pin  WU Ling-Hui  XU Min  YAN Liang  YUAN Chang-Zheng  YUAN Ye  ZHANG Bing-Yun  ZHANG Chang-Chun  ZHANG Jian-Yong  ZHANG Xue-Yao  ZHANG Yao  ZHENG Yang-Heng  ZHU Ke-Jun  ZHU Yong-Sheng  ZHU Zhi-Li  ZOU Jia-Heng 《中国物理C(英文版)》2010,34(3)
The calibration algorithm for RPC-based muon detector at BESⅢ has been developed. The calibration method, calibration error and algorithm performance are studied. The primary results of efficiency and noise at layer, module and strip levels have been calibrated with cosmic ray data. The calibration constants are available for simulation and reconstruction tuning. The results of Monte Carlo and data are also compared to check the validation and reliability of the algorithm.  相似文献   

2.
Cosmic-ray data of 90 M events have been collected and used for calibration,alignment as well as detector tuning. A special tracking algorithm for the BESⅢ muon counter is developed and verified with Monte-Carlo simulation and then further confirmed with the cosmic-ray data. The obtained strip resolutions are in good agreement with the design values. A new alignment approach for the BESⅢ muon counter is confirmed with the cosmic-ray data and proposed to be used in future analysis of experimental data.  相似文献   

3.
Cosmic-ray data of 90 M events have been collected and used for calibration,alignment as well as detector tuning. A special tracking algorithm for the BESⅢ muon counter is developed and verified with Monte-Carlo simulation and then further confirmed with the cosmic-ray data. The obtained strip resolutions are in good agreement with the design values. A new alignment approach for the BESⅢ muon counter is confirmed with the cosmic-ray data and proposed to be used in future analysis of experimental data.  相似文献   

4.
A novel photometric calibration framework is presented for a projector-camera (ProCam) display system, which is currently under booming development. Firstly, a piecewise bilinear model and five 5-ary color coding images are used to construct the homography between the image planes of a projector and a camera. Secondly, a photometric model is proposed to describe the data flow of the ProCam display system for displaying color images on colored surface in a general way. An efficient self-calibration algorithm is correspondingly put forward to recover the model parameters. Aiming to adapt this algorithm to different types of ProCam display system robustly, a 3× 7 masking coupling matrix and a patches image with 1024 color samples are adopted to fit the complex channel interference function of the display system. Finally, the experimental results demonstrate the validity and superiority of this calibration algorithm for the ProCam display system.  相似文献   

5.
We present detailed analysis of calibration process error for electro-optical detection systems, which can be simplified as the plane rotation around a non-orthogonal axis. By means of octonions it firstly proves that the plane rotation around a non-orthogonal axis can be decomposed into rotations around two perpendicular axes. The rotation is further divided into three steps, and the calibration error is hence discussed and obtained. The simulation and test results indicate that there are large calibration errors in calibration process. The pointing error can be effectively improved after separating error components, which provides a more accurate set data for further comDensation.  相似文献   

6.
LHAASO-WCDA is a large ground-based water Cherenkov detector array planned to be built at ShangriLa, Yunnan Province, China. As a major component of the LHAASO project, the main purpose of LHAASO-WCDA is to survey the northern sky for very-high-energy(above 100 GeV) gamma ray sources and measure the spectrum. To gain full knowledge of the water Cherenkov technique and to investigate the engineering issues, a 9-cell detector array has been built at the Yang-Ba-Jing site, neighboring the ARGO-YBJ experiment. With the array, charge calibration methods for both low and high ranges of the PMT readout are studied, whose result shows that a precision at several percentages can be reached, which can satisfy the requirement of the detector array. During the long term operation, the charge calibration stability and environmental afection are studied; in this paper, the results are discussed. These calibration methods are proposed to be applied in the future LHAASO-WCDA project.  相似文献   

7.
The fine mid-infrared absorption features of dimethyl methylphosphonate vapor have been characterized by using Fourier transforms infrared spectroscopy, and the nitrous oxide was used for calibration purpose. The results show that the main P-O-C and P=O bonds related absorption bands of dimethyl methylphosphonate vapor are peaked at 1050.01 and 1275.76 cm-1 respectively, those two bands show continuous characteristics at resolution of 0.125 cm-1.  相似文献   

8.
The needed electrical current for the magnet working under different energy loads can be easily calculated once the right relation between the magnet and the electrical current has been found. Therefore the excitation curve calibration for the magnet system is important to the SSRF. The measuring method on the magnet and the result of the excitation curve calibration are presented. The application of the excitation curve calibration for the bending magnet is given, and it is proved that the COD (Closed Orbit Distortion) and the working point of the storage ring are greatly affected by the current of the bending magnet.  相似文献   

9.
<正>A practical method for evaluating the three-dimensional(3D) position and velocity of a moving object used in the parabolic flight experiment is developed by using the binocular stereo vision measurement theory. The camera calibration mathematic model without considering the lens distortion is introduced.The direct linear transformation(DLT) algorithm is improved to accomplish the camera calibration.The camera calibration result and optimization algorithm are used to calculate the object's world coordinate from image coordinate.The 3D position and the velocity of the moving object are obtained.The standard uncertainty in estimating the velocity is 0.0024 m/s,which corresponds to 1%level of the velocity of the object in the experiment.The results show that this method is very useful for the parabolic flight experiments.  相似文献   

10.
Calibrating a small field camera is a challenging task because the traditional target with visible feature points that fit the limited space is difficult and costly to manufacture.We demonstrate a novel combined target used in camera calibration.The tangent points supplied by one circle located at the center of a square are used as invisible features,and the perspective projection invariance is proved.Both visible and invisible features extracted by the proposed feature extraction algorithm are used to solve the calibration. The target supplies a sufficient number of feature points to satisfy the requirements of calibration within a limited space.Experiments show that the approach can achieve high robustness and considerable accuracy. This approach has potential for computer vision applications particularly in small fields of view.  相似文献   

11.
The China Spallation Neutron Source (CSNS) is a large scientific facility with the main purpose of serving multidisciplinary research on material characterization using neutron scattering techniques. The accelerator system is to provide a proton beam of 120 kW with a repetition rate of 25 Hz initially (CSNSⅠ), progressively upgradeable to 240 kW (CSNS-Ⅱ) and 500 kW (CSNS-Ⅱ'). In addition to serving as a driving source for the spallation target, the proton beam can be exploited for serving additional functions both in fundamental and applied research. The expanded scientific application based on pulsed muons and fast neutrons is especially attractive in the overall consideration of CSNS upgrade options. A second target station that houses a muon-generating target and a fast-neutron-generating target in tandem, intercepting and removing a small part of the proton beam for the spallation target, is proposed. The muon and white neutron sources are operated principally in parasitic mode, leaving the main part of the beam directed to the spallation target. However, it is also possible to deliver the proton beam to the second target station in a dedicated mode for some special applications. Within the dual target configuration, the thin muon target placed upstream of the fast-neutron target will consume only about 5% of the beam traversed; the majority of the beam is used for fast-neutron production. A proton beam with a beam power of about 60 kW, an energy of 1.6 GeV and a repetition rate of 12.5 Hz will make the muon source and the white neutron source very attractive to multidisciplinary researchers.  相似文献   

12.
The new e^+e^- storage ring, VEPP-2000, is being commissioned at Budker Institute of Nuclear Physics, Novosibirsk. Measurement of the total cross section e^+e^- → hadrons in the whole VEPP-2000 energy range is one of the main goals of the new experiments. We discuss the goals of the measurement and the expected systematic errors.  相似文献   

13.
We describe some recent results on isospin breaking corrections which are of relevance for predictions of the leading order hadronic contribution to the muon anomalous magnetic moment aμ^had.LO when using τ lepton data. When these corrections are applied to the new combined data on the π^±π^0 spectral function, the prediction for aμ^had.LO based on τ lepton data gets closer to the one obtained using e^+e^- data.  相似文献   

14.
The KLOE experiment at the φ-factory DAФPNE has measured the pion form factor in the range between 0.1 〈 Mππ^2 〈 0.85 GeV^2 using events taken at √s = 1 GeV with a photon emitted at large polar angles in the initial state. This measurement extends the Mππ^2 region covered by KLOE ISR measurements of the pion form factor down to the two pion production threshold. The value obtained in this measurement of the dipion contribution to the muon anomalous magnetic moment of △αμ^ππ= (478.5±2-0stat±4.8syst±2.9theo)·10^-10 further confirms the discrepancy between the Standard Model evaluation for αμ and the experimental value measured by the (g-2) collaboration at BNL.  相似文献   

15.
The New Muon (g-2) Collaboration at Fermilab has proposed to measure the anomalous magnetic moment of the muon, αμ, a factor of four better than was done in E821 at the Brookhaven AGS, which obtained αμ = [116592089(63)] × 10^-11 ±0.54 ppm. The last digit of a, is changed from the published value owing to a new value of the ratio of the muon-to-proton magnetic moment that has become available. At present there appears to be a difference between the Standard-Model value and the measured value, at the ≌ 3 standard deviation level when electron-positron annihilation data are used to determine the lowest-order hadronic piece of the Standard Model contribution. The improved experiment, along with further advances in the determination of the hadronic contribution, should clarify this difference. Because of its ability to constrain the interpretation of discoveries made at the LHC, the improved measurement will be of significant value, whatever discoveries may come from the LHC.  相似文献   

16.
We update our Standard Model predictions for g-2 of the muon and for the hadronic contributions (5) 2 to the running of the QED coupling, Δαbad^5)(MZ^2). Particular emphasis is put on recent changes in the hadronic contributions from new data in the 2π channel and from the energy region just below 2 GeV.  相似文献   

17.
Results on the lowest-order hadronic vacuum polarization contribution to the muon magnetic anomaly are presented. They are based on the latest published experimental data used as input to the dispersion integral. Thus recent results on τ→υτππ^0 decays from Belle and on e^+e^- annihilation to π^+π^- from BABAR and KLOE are included. The new data, together with improved isospin-breaking corrections for τ decays, result into a much better consistency among the different results. A discrepancy between the Standard Model prediction and the direct g- 2 measurement is found at the level of 3σ.  相似文献   

18.
After a brief review of the muon g-2 status, we discuss hypothetical errors in the Standard Model prediction that might explain the present discrepancy with the experimental value. None of them seems likely. In particular, a hypothetical increase of the hadroproduction cross section in low-energy e^+e^- collisions could bridge the muon g-2 discrepancy, but it is shown to be unlikely in view of current experimental error estimates. If, nonetheless, this turns out to be the explanation of the discrepancy, then the 95% CL upper bound on the Higgs boson mass is reduced to about 135 GeV which, in conjunction with the experimental 114.4 GeV 95% CL lower bound, leaves a narrow window for the mass of this fundamental particle.  相似文献   

19.
We present the performance of the ALICE muon spectrometer for measuring the charm and beauty inclusive p t differential production cross sections via single muons and unlike-sign dimuons in proton-proton collisions at√ s = 14 TeV.  相似文献   

20.
We present the first measurement of the production cross section of a W boson with a single charm quark (c) in pp collisions at sqrt(s)=1.96 TeV, using soft muon tagging of c jets. In a data sample of approximately 1.8 fb(-1), recorded with the Collider Detector at Fermilab II detector at the Fermilab Tevatron, we select events with W+1 or 2 jets. We use the charge correlation between the W and the muon from the semileptonic decay of a charm hadron to extract the Wc signal. We measure sigma Wc(PTc >20 GeV/c,|eta c|<1.5) x BR(W-->l nu)=9.8+/-3.2 pb, in agreement with theoretical expectations.  相似文献   