首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Herein a quantitative method for the determination of seven penicillins in bovine plasma and veterinary drugs has been developed. Amoxicillin (AMO), ampicillin (AMP), penicillin G (PENG), penicillin V (PENV), oxacillin (OXA), cloxacillin (CLO) and dicloxacillin (DICLO) were separated on a Perfectsil ODS‐2 (250×4 mm, 5 μm) column, using gradient elution, with a mobile phase of 0.1% v/v TFA and ACN–methanol (90:10 v/v). PDA detection was used at 240 nm. Penicillins were isolated from bovine plasma by SPE on Lichrolut RP‐18 cartridges with mean recoveries from 85.7 to 113.5%. Colchicine (3 ng/μL) was used as an internal standard. The developed method was validated in terms of selectivity, linearity, accuracy, precision, stability and sensitivity. Repeatability (n = 5) and between‐day precision (n = 5) revealed RSD < 12%. The detection limits in the bovine plasma were estimated as 18 ng for AMO and AMP, 25 for PENG, PENV and OXA, 3 ng for CLO and 12 ng for DICLO. Spiked plasma samples were stable for 1 wk, except for AMP and CLO, which were stable for 3 wk and OXA for 4 wk. AMO, PENG and PENV were stable for two freeze–thaw cycles, OXA, CLO and DICLO for four, while AMP only for one.  相似文献   

2.
A quantitative method for the determination of four penicillin antibiotics, amoxicillin (AMO), oxacillin (OXA), cloxacillin (CLO), and dicloxacillin (DICLO), has been developed. Separation was achieved on an Inertsil ODS-3 (250 x 4 mm, 5 microm) column after selective extraction of penicillin drugs from biological matrices by means of SPE. Gradient elution with a mobile phase consisting of 0.1% TFA (pH 1) and ACN, and PDA detection with monitoring at 240 nm was applied. Salicylic acid (5 ng/microL) was used as the internal standard. RP-8 Adsorbex Merck cartridges provided high absolute recoveries (98-101%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <10%. Recoveries from biological samples ranged from 91 to 103%. The detection limits were estimated as 3.3 ng for AMO, OXA, and CLO, and 6.6 for DICLO in blood plasma. LOD in whole blood and urine was 6.6 ng. Injection volume was 20 microL. The method was applied to commercially available AMO containing pharmaceuticals and spiked biological matrices. The method was also applied to biological samples after AMO oral administration, where the drug was successfully identified and quantified.  相似文献   

3.
A confirmatory method for 6 penicillin antibiotics (amoxicillin, ampicillin, penicillin G, oxacillin, cloxacillin, and dicloxacillin) in honey is presented that allows determination and confirmation of identity of the antibiotics at trace levels. The method includes the use of a stable isotope-labeled internal standard benzyl (d7-phenyl) penicillate and removal of sugar and other substances by solvent and solid-phase extraction. The honey extracts are then analyzed for penicillin residues by liquid chromatography/electrospray ionization-tandem mass spectrometry. Mass spectral acquisition was achieved in an electrospray positive ion mode by applying multiple reaction monitoring of 2 or 3 fragment ion transitions to provide a high degree of sensitivity and specificity. Typical recoveries of 6 penicillins at fortification levels of 6, 16, 40, and 80 microg/kg ranged from 51.4 to 132.9%. The recoveries varied with the individual penicillins and were affected by different honey matrixes. The ion ratios were consistent and could be used for confirmation of identity of the penicillins. The method limits of detection (microg/kg) were 0.25 for amoxicillin, 0.19 for ampicillin, 0.068 for penicillin G, 0.028 for oxacillin, 0.052 for cloxacillin, and 0.085 for dicloxacillin. The method limits of confirmation (microg/kg) were 0.44 for amoxicillin, 0.52 for ampicillin, 0.23 for penicillin G, 0.14 for oxacillin, 0.14 for cloxacillin, and 0.15 for dicloxacillin when a sample size of 5 g honey was used.  相似文献   

4.
The simultaneous determination of mycotoxins was performed in 3 steps: extraction, cleanup, and detection. For extraction, a mixture of acetonitrile-water (60 + 40, v/v) was proved appropriate. For cleanup, a new Afla-Ochra-Zea immunoaffinity column was used. After derivatization with trifluoroacetic acid, the mycotoxins aflatoxins, ochratoxin A (OTA), and zearalenone (ZEA) were determined simultaneously by liquid chromatography with fluorescence detection. The detection limits in different matrixes after cleanup with the new immunoaffinity column were very low: aflatoxins, 0.002-0.7 microg/kg; OTA, 0.07-0.25 microg/kg; ZEA, 1-3 microg/kg. The limits of determination were: aflatoxins, 0.25 microg/kg; OTA, 0.5 microg/kg; ZEA, 5 microg/kg. The recovery rates for aflatoxins, OTA, and ZEA for rye and rice were between 86 and 93% when a 0.5 g sample matter per immunoaffinity column was used.  相似文献   

5.
An HPLC method with diode-array detection, at 355 nm, was developed and validated for the determination of seven tetracyclines (TCs) in milk: minocycline (MNC), TC, oxytetracycline (OTC), methacycline (MTC), demeclocycline (DMC), chlortetracycline (CTC), and doxycycline (DC). Oxalate buffer (pH 4) was used with 20% TCA as a deproteinization agent for the extraction of analytes from milk followed by SPE. The separation was achieved on an Inertsil ODS-3, 5 microm, 250 x 4 mm(2 )analytical column at ambient temperature. The mobile phase, a mixture of A: 0.01 M oxalic acid and B: CH(3)CN, was delivered using a gradient program. The procedure was validated according to the European Union decision 2002/657/EC determining selectivity, stability, decision limit, detection capability, accuracy, and precision. Mean recoveries of TCs from spiked milk samples (50, 100, and 200 ng/g) were 93.8-100.9% for MNC, 96.8-103.7% for OTC, 96.3-101.8% for TC, 99.4-107.2% for DMC, 99.4-102.9% for CTC, 96.3-102.7% for MTC, and 94.6-102.1% for DC. All RSD values were lower than 8.5%. The decision limits CC(a) calculated by spiking 20 blank milk samples at MRL (100 microg/kg) ranged from 101.25 to 105.84 microg/kg, while detection capability CC(b )from 103.94 to 108.88 microg/kg.  相似文献   

6.
High-performance liquid chromatography with diode-array detection (HPLC-DAD) was optimised and validated for the determination of tetracyclines in bovine milk and tissues. Milk and tissue samples were extracted and purified using a solid-phase extraction HLB Oasis cartridge and analysed using HPLC-DAD set at 365 nm. The analyses were carried out using the mobile phase of 0.01 M oxalic acid-acetonitrile-methanol (60:25:15, v/v/v) on a C8 column (250 x 4.6 mm I.D., 5 microm). Recoveries of tetracyclines from spiked samples at the three concentrations (0.5, 1 and 1.5) of the maximum residues limits (corresponding to 100 microg/kg for milk and the muscle) were higher than 81.1% in milk and 83.2% in muscle. The method was successfully validated for bovine milk and muscle in compliance with requirements set by draft SANCO/ 1805/ 2000 European Decision. The decision limit (CCalpha) was in the range 113.2-127.2 microg/kg and 107.7-129.9 micro/kg for all compounds in milk and muscle, respectively. The detection capability (CCbeta) was in the range 117.2-131.3 microg/kg and 114.9-133.1 microg/kg for all compounds in milk and muscle, respectively.  相似文献   

7.
Huang HY  Hsieh SH 《Electrophoresis》2008,29(18):3905-3915
In this study, on-line sample concentration methods, which coupled field-amplified sample injection and sweeping technology with MEEKC, were used to detect and analyze eight common penicillin antibiotics (nafcillin, dicloxacillin, ampicillin, oxacillin, penicillin V, cloxacillin, penicillin G, and amoxicillin). During the optimization of field-amplified sample injection-sweeping MEEKC, the composition of sample matrix and the length of acidic plug were found to be the predominant influences for penicillin stacking. Both zwitterionic ampicillin and amoxicillin could only be stacked through cation-selective-exhaustive-injection sweeping, whereas the other six penicillin compounds were found to be concentrated by anion-selective-exhaustive-injection sweeping. Hence, in order to simultaneously concentrate the eight penicillins in a single-run sweeping step, a combination of successive anion- and cation-selective injections was used. When compared with previous CE-UV methods, the proposed on-line concentration MEEKC method provided better detection sensitivity and faster separation for these penicillins either in single ion-selective injection or in successive anion-/cation-selective injection where the LODs were in the range of 0.2-2.8 microg/L and 0.5-5.8 microg/L, respectively.  相似文献   

8.
Xu C  Suo R  Zhang F  Chu X  Ding F  Ling Y  Yang M  Sun L 《色谱》2012,30(5):457-462
建立了测定动物饲料中三唑仑、艾司唑仑、硝西泮、地西泮、异丙嗪、氯氮平、唑吡坦、甲硫哒嗪、氯丙嗪和咪达唑仑10种违禁精神药物的超高效液相色谱-四极杆飞行时间质谱(UPLC-Q-TOF-MS)方法。样品经混合溶剂甲醇-0.1 mol/L HCl(9:1, v/v)振荡提取,再用MCX固相萃取柱净化处理后,采用UPLC-Q-TOF-MS分析检测。10种化合物在5~100 μg/L范围内均呈良好的线性关系,线性相关系数均大于0.99。本方法的硝西泮、唑吡坦和甲硫哒嗪的定量限(LOQ,以信噪比为10计)为8 μg/kg,三唑仑、艾司唑仑、地西泮、异丙嗪、氯丙嗪和咪达唑仑为10 μg/kg,氯氮平为20 μg/kg。3个添加水平(LOQ、2LOQ、4LOQ)的回收率试验结果表明,10种化合物的回收率在60.6%~108.5%范围内,相对标准偏差均小于10%。本方法可用于动物饲料中违禁精神药物的准确测定。  相似文献   

9.
A new multiresidue method has been developed and validated for the simultaneous analysis of 57 compounds, including organochlorine and organophosphorus pesticide residues (OCPs and OPPs) and polychlorinated biphenyls (PCBs), in eggs at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Egg samples were extracted by a simple and fast matrix solid phase dispersion (MSPD) procedure using C18 as sorbent, and ethyl acetate and acetonitrile saturated in n-hexane (85:15, v/v) as elution solvent with a simultaneous clean up with Florisil in-line. The QqQ analyzer acquired data in selected reaction monitoring (SRM) mode, permitting both quantification and confirmation in a single injection with a running time reduced up to 17.70 min. Recovery was in the range of 70-110% and 70-106% at 15 and 50 microg/kg, respectively. Precision values expressed as relative standard deviation (RSD) were lower than 20%. Linearity in the range of 10-150 microg/kg provided determination coefficients (R(2)) higher than 0.98 for all compounds. Limits of detection (LODs) for pesticides were < or =2.25 microg/kg and limits of quantification (LOQs) ranged from 0.02 to 7.78 microg/kg. LODs for PCBs were < or =0.41 microg/kg and LOQ were < or =0.71 microg/kg. The method was applied to real samples. Endosulfan sulphate and p,p'-DDE were found in two samples at concentrations below the first calibration level.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic (HPLC) assay was developed for the antitumor anthrapyrazole analogue, oxantrazole (OX), in rat whole blood and tissues. Blood samples were mixed with equal volumes of a 25% (w/v) aqueous solution of L-ascorbic acid, whereas tissue samples were homogenized with 1.5-3 volumes of an L-ascorbic acid-methanol-water (1:10:1, w/v/v) mixture to prevent oxidative degradation of OX. Samples were then treated with 60% (v/v) perchloric acid (25-30 microliters/ml of stabilized sample) to precipitate proteins, and centrifuged, with the resultant supernatants analyzed on HPLC utilizing a C8 column. The mobile phase for blood and urine samples consisted of 8% (v/v) glacial acetic acid, 13% (v/v) acetonitrile, 79% (v/v) water, 0.16% (w/v) sodium acetate, and 0.05% (w/v) L-ascorbic acid (final pH 2.7), and was pumped at 1.8 ml/min. Tissue samples were eluted at 2 ml/min with a mobile phase consisting of 8% (v/v) glacial acetic acid, 12% (v/v) acetonitrile, 80% (v/v) water, 0.16% (w/v) sodium acetate, and 0.0;5% (w/v) L-ascorbic acid. OX and internal standard were detected at 514 nm and had retention times of 2.3 and 3.1 min, respectively. The limit of quantitation of OX was 25-50 ng/g. Recovery of OX from biological samples ranged from 50 +/- 0.9% in spleen to 102.8 +/- 1.8% in RG-2 glioma. The analytical method was applied to a pharmacokinetic study in rats.  相似文献   

11.
A high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of residues of penicillins and cephalosporins in milk has been developed. After a simple extraction with acetonitrile, the extract was directly injected into the LC/MS/MS system on a C(18) column. A gradient consisting of acetonitrile and water, each containing 0.1% formic acid, was applied. The abundant parent ions [M + H](+) produced by positive electrospray ionisation were selected for fragmentation with argon. For each compound at least one fragment was recorded with multiple reaction monitoring. The limits of detection ranged from 1.5 to 25 microg/kg and the limits of quantification ranged from 4 to 50 microg/kg. Recoveries were examined at three levels (MRL, 0.5 x MRL, 2 x MRL) and ranged from 57 to 88%. The coefficients of variation obtained for the repeatability experiments were in agreement with those specified by the Horwitz equation. Linearity was checked by injecting extracts of samples spiked with increasing amounts of the different standards ranging from 0 to 150 microg/kg. The advantage of this method over existing methods is the very simple sample pre-treatment which makes the method very suitable for routine analysis.  相似文献   

12.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of fumonisin B1 (FB1), B2 (FB2) and B3 (FB3) in cornflakes is described. During method development, special attention was paid to the selection of a suitable internal standard (IS) in order to offer a good alternative for deuterated FB1. In this respect, the C12-sphinganine analogue (2S,3R)-2-aminododecane-1,3-diol was chosen because of its structural similarity to the fumonisin backbone and its chromatographic elution between the target analytes. For the extraction of the fumonisins from the cornflakes matrix, MeOH/H2O (adjusted to pH 4 with 0.1 M HCl; 70:30, v/v), ACN/MeOH/H(2)O (25:25:50, v/v/v) and acidified ACN/MeOH/H2O (25:25:50, v/v/v; pH 4) were evaluated. Preference was given to acidified MeOH/H2O (70:30, v/v) with mean recoveries (n=12) for FB1, FB2 and FB3 of, respectively, 84+/-10, 78+/-7 and 85+/-9%. Cleanup was performed using immunoaffinity columns (FumoniTest, VICAM). The chromatography was performed under isocratic conditions at a flow of 0.3 mL min-1 with a mobile phase consisting of ACN/H2O (60:40, v/v) containing 0.3% formic acid. The mass spectrometer was operated in the positive electrospray ionization (ESI+) mode using multiple reaction monitoring (MRM). An intralaboratory validation was conducted with fortified samples determining limits of detection (LOD), limits of quantification (LOQ), precision, trueness, specificity and measurement uncertainty. The LOD concentrations for FB1, FB2 and FB3 were 20, 7.5 and 12.5 microg/kg. The LOQs were 40 microg/kg for FB1, 15 microg/kg for FB2 and 25 microg/kg for FB3. The coefficients of variation (CVs) under repeatability conditions varied from 11 to 13% for FB1, from 9 to 14% for FB2 and from 7 to 10% for FB3. Under within-laboratory reproducibility conditions, the CVs ranged from 12 to 17% for FB1, from 9 to 16% for FB2 and from 7 to 13% for FB3. The percent bias for FB1 varied from -12 to -10%, while for FB2 and FB3 bias ranged, respectively, from -4 to -2% and from -12 to -5%. The expanded measurement uncertainties for FB1, FB2 and FB3 were, respectively, 19, 18 and 22%.  相似文献   

13.
A collaborative study involving 14 laboratories was conducted to determine residues of ampicillin in porcine muscle tissue by using a liquid chromatographic method developed for multipenicillin analysis that can quantitate 8 penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, amoxicillin, nafcillin, oxacillin, cloxacillin, and dicloxacillin) at trace levels in muscle tissue. This method involves extraction of the penicillins with phosphate buffer, pH 9, followed by cleanup and concentration on a C18 solid-phase extraction column and reaction with benzoic anhydride at 50 degrees C and with 1,2,4-triazole and mercury(II) chloride solution, pH 9.0, at 65 degrees C. The derivatized compounds are eluted isocratically on a C8 column with a mobile phase of acetonitrile and phosphate buffer (pH 6; 0.1 M) containing sodium thiosulfate and the ion-pair reagent tetrabutylammonium hydrogen sulfate. The penicillins are detected by UV absorption at 325 nm. The limit of detection and the limit of determination (quantitation) of the method were calculated to be approximately 3-5 and 25 microg/kg, respectively, in accordance with the criteria of European Union (EU) Decision No. 93/256/EEC. In this first interlaboratory study, collaborators were instructed to monitor 4 different penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, and amoxicillin) by analyzing 8 blind samples of muscle tissue in triplicate. These samples were prepared from 2 materials containing different concentrations of incurred ampicillin (63.5 microg/kg for material No. 1 and 358.1 microg/kg for material No. 2) and 1 blank material. The repeatability relative standard deviation and the reproducibility relative standard deviation were 10.2 and 17.4%, respectively, for material No. 1 and 7.0 and 16.0%, respectively, for material No. 2. These results demonstrate that the method is suitable for the determination of ampicillin residues in muscle tissue at the EU maximum residue limit (50 microg/kg) and above. However, the identification of positives by this procedure may need additional confirmation by techniques with greater specificity, such as liquid chromatography combined with mass spectrometry, or tandem mass spectrometry. Investigations regarding the basis of interlaboratory testing studies will further demonstrate the suitability of multiresidue methodology for detecting and quantitating other compounds in the family of penicillin antibiotics.  相似文献   

14.
A multiresidue analytical method was developed for the quantification of benzylpenicillin (PCG), phenoxymethylpenicillin (PCV), oxacillin (MPIPC), cloxacillin (MCIPC), nafcillin (NFPC) and dicloxacillin (MDIPC) in bovine tissues using liquid chromatography- electrospray ionization tandem mass spectrometry (LC-ESI MS/MS) with a multiple reaction monitoring technique. Using the deuterated PCG and NFPC as internal standard was effective for improvement of repeatability and accuracy. We chose [M-H-141]- as a monitor ion of MRM analysis and [M-H]- as a precursor ion for each penicillin. Combination of an ion-exchange cartridge clean-up and ion-pair LC enable us to determine the residual penicillins using the standard curves made from standard solutions without the influence of sample matrix on the MS. The average recoveries of PCG, PCV, MPIPC, MCIPC, NFPC and MDIPC from bovine liver, kidney and muscle at the same concentrations as the tolerance levels of PCG (50 microg/kg) ranged from 77 to 101% with the coefficients of variation ranging from 0.7 to 4.2% (n = 5). The limits of quantification for the six penicillins were 2-10 microg/kg in bovine muscle, liver and kidney (S/N ratio >10).  相似文献   

15.
Some vegetable oils such as canola (CaO), corn (CO), soybean (SO), and walnut (WO) oils have similar color with cod liver oil (CLO), therefore, the presence of these oils was difficult to detect using naked eye. For this reason, Fourier transform infrared (FTIR) spectroscopy using horizontal attenuated total reflectance (HATR) as sampling accessory and in the combination with chemometrics was developed for detection and quantification of these vegetable oils as adulterants in CLO. The quantification of vegetable oils was carried out by using multivariate calibrations of partial least squares (PLS) and principle component regression (PCR), while the classification between pure CLO and CLOs adulterated with CaO, CO, SO, and WO was performed using discriminant analysis (DA). PLS with FTIR normal spectra was more suitable compared with PCR for quantification purposes with coefficient of determination (R2) higher than 0.99 and root mean square error of calibration (RMSEC) in the range of 0.04-0.82% (v/v). The PLS model was further used to predict the levels of these vegetable oils in independent samples for validation/prediction purpose. The root mean square error of prediction (RMSEP) values obtained were of 1.75% (v/v) (CaO), 1.39% (v/v) (CO), 1.35% (v/v) (SO), and 1.37% (v/v) (WO), respectively. The classification using DA revealed that the developed method can classify CLO and that mixed with these vegetable oils using 9 principal components.  相似文献   

16.
张艳  吴银良 《色谱》2005,23(6):636-638
建立了一种快速、灵敏、环保的固相萃取-反相高效液相色谱同时分析动物肉组织中5种磺胺类药物残留的方法。将样品加入到盛有无水硫酸钠的离心管中,再用乙酸乙酯提取;提取液经氨基固相萃取柱净化后,用1.5%(体积分数)乙酸乙醇溶液洗脱。洗脱液用高效液相色谱分离,二极管阵列检测器检测,外标法定量。5种磺胺类药物的线性关系良好,磺胺二甲基嘧啶(SM2)、磺胺间甲氧嘧啶(SMM)、磺胺甲唑(SMZ)的线性范围均为30~5000 μg/L,磺胺二甲氧嘧啶(SDM)、磺胺喹啉(SQ)的线性范围均为60~5000 μg/L。2种动物肉组织(鸡肉、猪肉)中5种磺胺类药物的加标回收率在73.2%至97.3%范围内,当添加水平为50 μg/kg时,加标回收率的相对标准偏差在2.5%至11.6%范围内;SM2,SMM和SMZ的检测限(S/N=3)和定量限(S/N=10)分别为3 μg/kg和10 μg/kg,SDM和SQ的检测限和定量限分别为7 μg/kg和25 μg/kg。  相似文献   

17.
This study describes the ability of nanoscale liquid chromatography (nano-LC) coupled with UV or mass spectrometry (MS) for the simultaneous determination of eight common penicillin antibiotics (amoxicillin, ampicillin, penicillin G, penicillin V, oxacillin, cloxacillin, nafcillin and dicloxacillin) in commercial samples (pharmaceuticals, milk, porcine tissues (liver and kidney)) for the first time. Material types of the on-column polymeric frits (polystyrene-based and polymethacrylate-based monoliths) and the packed stationary phase materials (C8 and C18 particles of 3 μm) used in the nano-LC for the influence of penicillin separation were evaluated. The nano-LC and MS parameters such as the composition and flow rate of mobile phase, capillary voltage and temperature of dry gas were examined in order to acquire high separation resolution and detection sensitivity for penicillin analyses. Furthermore, a home-made in-line filter (a nylon membrane of 0.2 μm pore size), was first used to connect with the flow cell of high sensitivity UV detector or the nanoelectrospray needle in MS detection. The result indicated it could effectively improve the reproducibility of penicillin mass signals or prolong the lifetime of the flow cell. The nano-LC methods provided good quantitative precisions in the range of 89.5–111.2% for UV detection at 0.5 μg/mL penicillins, and 83. 1–94.9% for MS detection at 5 μg/L penicillins), respectively, as well as offered stable retention repeatabilities (the relative standard deviation (RSD) of retention time was lower 0.30% in both the UV and MS detections). Compared to other LC–MS methods, the proposed nano-LC systems provided better detection sensitivity for these penicillins (the limits of detection (LOD) was of 2.27–4.06 μg/L for UV mode, and 0.01–0.51 μg/L for MS mode) when either UV or MS detector was employed.  相似文献   

18.
Liu Y  Han S  Feng Q  Wang J 《色谱》2011,29(11):1076-1081
利用超高效液相色谱-电喷雾三重四极杆质谱仪建立了中药中马兜铃酸A和B的定性定量分析方法。选取柴胡、生甘草、桔梗、龙胆泻肝丸、消胖丸、减肥茶等14种代表性样品,用甲醇-水(70:30, v/v)溶液加热回流提取,经Oasis MAX固相萃取柱富集净化后,在Eclipse RP HD C18反相柱(150 mm×2.1 mm, 1.8 μm)上进行分离;流动相为5 mmol/L乙酸铵水溶液(pH 7.5)-乙腈(75:25, v/v)。采用电喷雾离子源正离子模式(ESI+)和多反应监测模式(MRM)进行质谱分析。马兜铃酸A和B的线性范围分别为0.5~200 μg/L和1~200 μg/L,相关系数(r2)均大于0.995;检出限(LODs)分别为5 μg/kg和7.5 μg/kg;定量限(LOQs)分别为12.5 μg/kg和25 μg/kg。在100 μg/kg和500 μg/kg添加水平下,马兜铃酸A和B的回收率(n=6)范围分别为60.3%~96.4%和61.3%~94.7%,相对标准偏差均不大于10.2%。该方法灵敏度高,重复性好,操作简便,适用于中药材、饮片及中成药中马兜铃酸A和B的痕量检测。  相似文献   

19.
Gas chromatography with electron capture detection (GC-ECD) is a highly explosive-sensitive analytical technique. However, its application to the analysis of sediment extracts is hampered by the presence of numerous endogenous interferences. In the present study, solid-phase microextraction (SPME) was used both as a purification technique for sediment extracts and as an extraction technique for water samples prior to analysis by GC-ECD. SPME/GC-ECD coupling was optimized and applied to the trace analysis of nine explosives including nitroaromatics and RDX in real seawater and marine sediment samples. Addition of a high concentration of salt (30%, w/v) in the aqueous medium and use of a carbowax/divinylbenzene (CW/DVB) coating led to optimal extraction efficiencies. Method detection limits (MDLs) ranged from 0.05 to 0.81 microg/L in water and from 1 to 9 microg/kg in dry sediment. Except for RDX, spike recoveries in seawater were satisfactory (89-147%) when samples were fortified at 2 microg/L of each analyte. Spike recoveries from dry sediment fortified at 10 microg/kg of each analyte gave lower recoveries but these could also be due to degradation in the matrix. With a smaller volume of aqueous sample required compared to solid-phase extraction (SPE), SPME is an attractive method for the analysis of limited volumes of sediment pore-water. Moreover, the use of SPME eliminated interferences present in sediment extracts thus allowing the detection of the target analytes that were otherwise difficult to detect by direct injection.  相似文献   

20.
建立了气相色谱-负离子化学电离源质谱同时测定动物组织中氯霉素(CAP)、甲砜霉素(TAP)和氟甲砜霉素(FF)残留量的方法。样品用乙酸乙酯提取,正己烷分配去脂肪,再用Florisil柱进一步净化,甲苯作为反应介质,用N,O-双(三甲基硅基)三氟乙酰胺(BSTFA)-三甲基氯硅烷(TMCS)(体积比为99∶1)进行硅烷化处理,用间硝基氯霉素(m-CAP)作为内标进行测定。CAP的检测限可达到0.03 μg/kg,TAP和FF的检测限可达到0.2 μg/kg;上述3种药物的标准曲线的线性相关系数均大于0.99。CAP,FF和TAP的批内测定的精密度(以相对标准偏差表示)依次为5.5%,10.4%和8.8%;批间测定的精密度依次为7.4%,20.7%和19.1%。回收率为80.0%~111.5%,相对标准偏差为1.2%~15.4%。该方法前处理步骤简单,处理后杂质干扰少,灵敏度高,适用性强,可用于猪肉及禽类、水产品等多种动物组织中氯霉素类药物残留的检测。  相似文献   