首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   4篇
  国内免费   2篇
化学   41篇
综合类   1篇
数学   2篇
物理学   7篇
  2020年   1篇
  2014年   1篇
  2013年   3篇
  2012年   2篇
  2011年   3篇
  2010年   1篇
  2008年   4篇
  2007年   5篇
  2006年   3篇
  2005年   5篇
  2004年   1篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1997年   1篇
  1995年   2篇
  1987年   1篇
  1985年   2篇
  1984年   2篇
  1983年   2篇
  1981年   4篇
  1979年   1篇
  1978年   2篇
  1962年   1篇
排序方式: 共有51条查询结果,搜索用时 15 毫秒
1.
A new method has been described to determine both benzodiazepines (six) and tricyclic antidepressants (four) simultaneously in saliva by HPLC with a UV detector set at 240 nm using cholchicine as the internal standard. A careful specific sequential solid‐phase elution was optimized and performed to elute benzodiazepines using a mixture of methanol‐acetonitrile (1:1 v/v) followed by the elution of tricyclic antidepressants with methanol. Separation of the compounds was performed on a Kromasil column (250 × 4 mm, 5 μm) by a gradient eluents consisting of 0.05 M CH3COONH4‐acetonitrile‐methanol (55:15:30 v/v/v). The results were linear for both benzodiazepines and tricyclic antidepressants up to 20 ng μL‐1 with the correlation coefficients greater than 0.998. The sensitivity limits, LOD and LOQ were 0.08‐0.34 ng μL‐1 and 0.28‐1.13 ng μL‐1, respectively. The method is simple, fast and reliable with good specificity and sensitivity, will be suitable for use in a clinical setting, where there is a concomitant use of 1,4‐benzodiazepines and tricyclic antidepressants.  相似文献   
2.
Lasers and amplifiers in a single fiber have been developed rapidly, especially for optical fiber communication and various sensors, in the recent years. However, remarkable progress and achievement have been made mainly in silica fiber doped with rare earth elements. In this paper, we report the progress on the development of the Yb3+-doped phosphate fiber laser.  相似文献   
3.
Atomistic simulations are reported of a model of CO2 in water. CO2 is modelled by partial charges and Lennard-Jones interaction sites on each atom; the SPC/E model for water is used. Good agreement with experiment is found for the translational diffusion constants. The variation of the dynamics with the potential parameter was investigated. As expected, the orientational correlation times increase as the magnitude of the quadrupole moment is increased, but the translational diffusion constants are found to be surprisingly insensitive to the magnitude of the CO2 quadrupole moment. The translational friction coefficient was resolved into electrostatic, Lennard-Jones and cross-terms; the Lennard-Jones contribution is found to be the largest. Varying the Lennard-Jones size parameter affects both translational and reorientational motion. In order to try to understand these results further, the variation of solvation free energy was investigated and the solvent structure around carbon dioxide was examined as the electrostatic and Lennard-Jones parameters were changed. The temperature dependence of the self-diffusion constant of pure SPC/E water was determined.  相似文献   
4.
In this study Monte Carlo simulations are used to determine the solvation properties of model hydrophobic (xenon and hard sphere) and hydrophilic (dimethyl ether) solutes in SPC/E water. Various contributions to the experimental solvation entropy, including the solvent reorganization entropy, have been determined. The main conclusion drawn, which is in accord with solubility data, is that poor solubility correlates with poor solute-water interaction. At room temperature, energy dominates the aqueous solubility of both hydrophobic and hydrophilic solutes, rather than entropy. However, at higher temperatures the solubility can pass through a minimum, and then entropy becomes dominant. Another interesting finding is the presence of larger than expected cavities in water. Two different simulation results support this finding. This unexpected hollow structure in water explains why a hard sphere solute is more soluble in water than in a comparable hard sphere or Lennard-Jones solvent. Hydrogen bonding causes water to aggregate into clusters that produce a few large cavities rather than many smaller cavities. The propensity for clustering also explains why water gives the illusion of being a low density liquid. Sufficient theoretical apparatus is developed to connect theoretical solvation properties to those measured by simulation and experiment. Finally, based on gas solubility, an intuitive hydrophobic/hydrophilic scale is developed.  相似文献   
5.
A high-performance liquid chromatographic method was developed for the determination of five penicillins: penicillin G (PENG), penicillin V (PENV), oxacillin (OX), cloxacillin (CLO), and dicloxacillin (DICLO), in bovine muscle. Samples were macerated with a mixture of H(2)O/CH(3)CN (1:1) and purified using RP-8 Adsorbex SPE cartridges after centrifugation, with mean recovery from spiked samples higher than 89%. The separation of the examined penicillins was achieved on an analytical column, an Inertsil C8 5 microm, 250x4 mm(2), at ambient temperature. The mobile phase consisted of 0.1% TFA/ACN 50:50 v/v delivered isocratically at a flow rate of 1.1 mL/min. Analytes were monitored at 240 nm. The procedure was validated according to the European Union Decision 2002/657/EC by means of selectivity, stability, decision limit, detection capability, accuracy, and precision. Method's LOQ values achieved were 54 microg/kg for PENG and DICLO, 46 microg/kg for PENV, 16 microg/kg for OX, and 43 microg/kg for DICLO. The detection capabilities (CC(beta)) were 73.6 microg/kg for PENG, 29.1 microg/kg for PENV, 350.6 microg/kg for OX, 379.9 microg/kg for CLO, and 355.8 microg/kg for DICLO. The method was applied to various samples from the local market. Two penicillins were identified by photodiode array (PDA) detection and quantified.  相似文献   
6.
A new oxidimetric titrant, bis(trifluoroacetoxy)iodobenzene is proposed for potentiometric titrations in acetonitrile and water-acetonitrile media. The general analytical conditions for using this titrant and the results for the potentiometric titrations of various inorganic and organic reductants are described.  相似文献   
7.
The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked immunosorbent assay. Immunoglobulins from selected antisera were immobilised on CNBr-activated Sepharose 4B. The immunoaffinity column was used for the purification of plant and plant cell culture extracts prior to their analysis by HPLC. Immunoaffinity chromatography enabled the selective concentration of taxoids and enhanced sample clean-up.  相似文献   
8.
A TLC densitometric method for the determination of the aminophenol isomers in water samples has been developed. The aminophenols are first extracted into chloroform-isoamylalcohol (1:2) mixture. The extracted aminophenols are separated on a TLC plate and visualized by spaying solution of 2,4,7-trintro-9-fluorenone in acetone. The colored spots are scanned for light absorption or reflection and the amount of each aminophenol is evaluated.  相似文献   
9.
Summary A major problem in the HPLC analysis of alkaloids is the poor peak shape and consequently low resolution, due to the interactions of the basic alkaloids with the residual acidic silanol groups of most reversed phase materials. The performance of new packing materials specially designed for the separation of basic compounds has been studied using mobile phases without the special additives commonly applied in the analysis of alkaloids. Strongly basic Cinchona alkaloids were used as test compounds. Retention characteristics and selectivities of each material were studied, after mobile phase optimisation for the column. The influence of the major factors (nature and content of the organic modifier, pH value, salt concentration) affecting resolution was studied. The mobile phases were chosen so that they could be used in thermospray LC-MS. The addition of salts to the mobile phase improves separation but in general the modification of the mobile phase gave little change in selectivity. The performance of silicabased C18 material proved superior to the polymer materials tested.  相似文献   
10.
The use of dicyclohexyl-18-crown-6 (DCC) as charge transfer reagent for the oxidation of benzaldehyde in organic solvents by aqueous solution of potassium permanganate is presented. The oxidation in the presence of a catalyst is found to be quantitative and suitable for the determination of benzaldehyde. Results for the determination of benzaldehyde in benzene and cyclohexane are given.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号