A new method has been described to determine both benzodiazepines (six) and tricyclic antidepressants (four) simultaneously in saliva by HPLC with a UV detector set at 240 nm using cholchicine as the internal standard. A careful specific sequential solid‐phase elution was optimized and performed to elute benzodiazepines using a mixture of methanol‐acetonitrile (1:1 v/v) followed by the elution of tricyclic antidepressants with methanol. Separation of the compounds was performed on a Kromasil column (250 × 4 mm, 5 μm) by a gradient eluents consisting of 0.05 M CH3COONH4‐acetonitrile‐methanol (55:15:30 v/v/v). The results were linear for both benzodiazepines and tricyclic antidepressants up to 20 ng μL‐1 with the correlation coefficients greater than 0.998. The sensitivity limits, LOD and LOQ were 0.08‐0.34 ng μL‐1 and 0.28‐1.13 ng μL‐1, respectively. The method is simple, fast and reliable with good specificity and sensitivity, will be suitable for use in a clinical setting, where there is a concomitant use of 1,4‐benzodiazepines and tricyclic antidepressants.  相似文献   
3.
Herein a quantitative method for the determination of seven penicillins in bovine plasma and veterinary drugs has been developed. Amoxicillin (AMO), ampicillin (AMP), penicillin G (PENG), penicillin V (PENV), oxacillin (OXA), cloxacillin (CLO) and dicloxacillin (DICLO) were separated on a Perfectsil ODS‐2 (250×4 mm, 5 μm) column, using gradient elution, with a mobile phase of 0.1% v/v TFA and ACN–methanol (90:10 v/v). PDA detection was used at 240 nm. Penicillins were isolated from bovine plasma by SPE on Lichrolut RP‐18 cartridges with mean recoveries from 85.7 to 113.5%. Colchicine (3 ng/μL) was used as an internal standard. The developed method was validated in terms of selectivity, linearity, accuracy, precision, stability and sensitivity. Repeatability (n = 5) and between‐day precision (n = 5) revealed RSD < 12%. The detection limits in the bovine plasma were estimated as 18 ng for AMO and AMP, 25 for PENG, PENV and OXA, 3 ng for CLO and 12 ng for DICLO. Spiked plasma samples were stable for 1 wk, except for AMP and CLO, which were stable for 3 wk and OXA for 4 wk. AMO, PENG and PENV were stable for two freeze–thaw cycles, OXA, CLO and DICLO for four, while AMP only for one.  相似文献   
4.
A sensitive and selective confirmatory method for milk‐residue analysis of ten quinolones and eight cephalosporins by LC‐MS/MS has been developed herein. For the chromatographic separation of target analytes, a Perfectsil ODS‐2 (250 × 4 mm, 5 μm) analytical column was used and gradient elution was applied, using a mobile phase of 0.1% w/w TFA in water and 0.1% w/w TFA in ACN. Ultrasound‐assisted matrix solid‐phase dispersion procedure was applied for the extraction and clean‐up procedure of antimicrobials agents from milk matrix using a mixture of Bond Elut Plexa sorbent and QuEChERS. The method was validated meeting the European Legislation determining selectivity, linearity response, trueness, precision (repeatability and between‐day reproducibility), decision limit, detection capability, and ruggedness following the Youden approach. Recoveries of all antibiotics ranged from 81.7 to 117.9%, while RSD values were lower than 13.7%. Limits of quantification for all examined compounds ranged from 2.4 to 15.0 μg/kg, substantially lower than the maximum residue limits established by the European Union (30–100 μg/kg).  相似文献   
5.
A sensitive and selective confirmatory analytical method for the multi-residue determination of seven quinolones (ciprofloxacin, enrofloxacin, sarafloxacin, danofloxacin, oxolinic acid, nalidixic acid and flumequine) in gilthead seabream (Sparus aurata) was developed. The sample pre-treatment involves extraction with 0.1M NaOH and purification by solid-phase extraction (SPE) on Waters Oasis HLB cartridges followed by the determination of all compounds in a single LC-electrospray ionization MS/MS run. Separation was achieved on a Perfectsil ODS-2, 5mum, 250mmx4mm, analytical column (MZ Analysentechnik) by gradient elution using a mixture of 0.2% (v/v) formic acid, methanol and acetonitrile within 30min. Multiple reaction monitoring (MRM) was used for selective detection of each quinolone. Accuracy was evaluated through recovery studies at three different fortification levels. The mean recoveries are between 90 and 132% for the selected levels with RSD values lower than 20%. The method presents satisfactory results for linearity, precision and limits of quantification. The latter are much lower than the maximum residue limits (MRLs) established by the European Union for quinolones in fish tissues (6-8mug/kg).  相似文献   
6.
A high-performance liquid chromatographic method was developed for the determination of five penicillins: penicillin G (PENG), penicillin V (PENV), oxacillin (OX), cloxacillin (CLO), and dicloxacillin (DICLO), in bovine muscle. Samples were macerated with a mixture of H(2)O/CH(3)CN (1:1) and purified using RP-8 Adsorbex SPE cartridges after centrifugation, with mean recovery from spiked samples higher than 89%. The separation of the examined penicillins was achieved on an analytical column, an Inertsil C8 5 microm, 250x4 mm(2), at ambient temperature. The mobile phase consisted of 0.1% TFA/ACN 50:50 v/v delivered isocratically at a flow rate of 1.1 mL/min. Analytes were monitored at 240 nm. The procedure was validated according to the European Union Decision 2002/657/EC by means of selectivity, stability, decision limit, detection capability, accuracy, and precision. Method's LOQ values achieved were 54 microg/kg for PENG and DICLO, 46 microg/kg for PENV, 16 microg/kg for OX, and 43 microg/kg for DICLO. The detection capabilities (CC(beta)) were 73.6 microg/kg for PENG, 29.1 microg/kg for PENV, 350.6 microg/kg for OX, 379.9 microg/kg for CLO, and 355.8 microg/kg for DICLO. The method was applied to various samples from the local market. Two penicillins were identified by photodiode array (PDA) detection and quantified.  相似文献   
7.
A high-performance liquid chromatographic method was applied to evaluate the effect of bicarbonate (NaHCO3) and phosphate (NaH2PO4, Na2HPO4) buffers on monomer leachability of dental resin composites. Evetric was the restorative resin composite that was investigated in current study. Forty disk-shaped resin composite specimens (n?=?40) were immersed by means of a silk string in the following solutions: Distilled water (A), phosphate buffer (B), bicarbonate buffer (C), artificial saliva (D). After seven (7) and fourteen (14) days, the eluates were analyzed by means of High Performance Liquid Chromatography (HPLC). Subsequently, new specimens were fabricated and immersed in fresh solutions in which methanol 12% (v/v) was added. After seven and fourteen days of storage, the leaching of monomers was examined by means of HPLC, which was proved to be an effective tool to buffers demonstrate the inhibiting effect of phosphate and bicarbonate ions on the leaching pattern of dental resin composites.  相似文献   
8.
The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL.  相似文献   
9.
The increasing interest in antioxidant properties of cereal and cereal-based products has prompted the development of a simple and reliable HPLC method for the simultaneous determination of important phytochemicals like tocopherols (T), tocotrienols (T3) and carotenoids. Separation was carried out on a Nucleosil 100 C(18) column, 5 μm (250 mm × 4.6 mm) thermostated at 25 °C, using a linear gradient elution system starting with methanol and ending with a mixture of methanol-isopropanol-acetonitrile. All separated compounds including the internal standard (α-tocopherol acetate) were eluted within 16 min and detected by dual detection: fluorescence for tocopherols and tocotrienols at 290 nm excitation and 320 nm emission and UV-vis photodiode array detection for lutein and β-carotene at 450 nm. Detection limits ranged from 0.2 μg/g (β-carotene) to 1.60 μg/g (α-tocopherol). The intra- and inter-assay coefficients of variation were calculated by using cereals with different levels of lipophilic antioxidants. The extraction method involved sample saponification and clean-up by solid-phase extraction (SPE). The extraction recoveries obtained using OASIS HLB SPE cartridges and dichloromethane as eluent were in the range of 90.2-110.1%, with RSD lower than 10%. The method was successfully applied to cereals: durum wheat, bread wheat, rice, barley, oat, rye, corn and triticale.  相似文献   
10.
A HPLC method with diode-array detection, at 265 nm, was developed and validated for the determination of ten sulfonamides (SAs): sulfadiazine (SDZ), sulfathiazine (STZ), sulfamethoxine (SMTH), sulfamethizole (SMZ), sulfamethoxypyridazine (SMPZ), sulfamonomethoxine (SMMX), sulfamethoxazole (SMXZ), sulfisoxazole (SIX), sulfadimethoxine (SDMX), and sulfaquinoxaline (SQX) in milk. A mixture of ethyl acetate, n-hexane, and isopropanol was used for the extraction of target analytes from milk. The mobile phase, a mixture of 0.1% v/v formic acid, CH(3) CN, and CH(3) OH was delivered to the analytical column under a gradient program. The procedure was validated according to the European Union regulation 2002/657/EC in terms of selectivity, stability, decision limit, detection capability, accuracy, and precision. Mean recoveries of sulfonamides from milk samples spiked at three concentration levels (0.5×MRL, 1×MRL, and 1.5×MRL) (MRL, maximum residue level) were 93.9-115.9% for SDZ, 97.8-102.9% for STZ, 94.6-107.0% for SMTH, 98.3-111.5% for SMZ, 95.3-108.4% for SMPZ, 97.9-106.0% for SMMX, 97.6-111.3% for SMXZ, 94.3-104.6% for SIX, 96.4-109.1% for SDMX, and 98.2-111.2% for SQX. All RSD values were lower than 8.8%. The decision limits CCa calculated by spiking 20 blank milk samples at MRL (100 μg/kg) ranged from 101.61 to 106.84 μg/kg, whereas the detection capability CCb ranged from 105.64 to 119.01 μg/kg.  相似文献   