1.
The effect of thickness on the nonlinear optical properties of Au nanoparticles which produced by laser ablation of high purity gold bulk in distilled water were investigated by employing different optical techniques. Experiments were performed on the 0.3, 0.6, and 1 mm thickness cells of Au nanoparticles-fluid. The effect of nonlinear refractive index of samples on the laser beam broadening was observed. The optical limiting behavior of samples is investigated by measuring the transmitted intensity of the laser beam through the samples. The third order nonlinearity of Au nanoparticles-fluid was measured by using Z-scan data. Results show a positive second order refractive index and absorption coefficient for Au nanoparticles-fluid that are increased in due of increasing the thickness of the cells. The magnitudes of both real and imaginary parts of third order susceptibility of samples are increased by increasing the thickness.  相似文献   

2.
韩金  张锦龙  程鑫彬  王占山 《光学学报》2012,32(1):131001-317
半波孔问题严重影响了倍频分束镜在高功率激光系统中的应用。为研究半波孔的产生机理,分别模拟了由高、低折射率膜层厚度失配和膜料色散失配引起的1/4波长对称规整膜系的半波孔。基于等效层理论,在Matlab平台上计算膜系的等效折射率E,绘出其对应的反射率极值包络曲线。通过研究对称膜系的等效折射率、反射率光谱和反射率包络之间的关系,从原理上分析了半波孔的大小、位置和变化趋势等特点。结果表明,膜层的厚度失配使对称膜系的等效折射率在光谱半波处产生截止带。膜层数越多,膜层厚度和膜料色散的失配越严重,则倍频分束镜的半波孔越深。  相似文献   

3.
When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.  相似文献   

4.
熊芬  胡中文  姜明达 《应用光学》2012,33(1):148-152
常用的测量折射率的方法如偏向角法、自准直法、临界角法、 V棱镜法等,这些方法通常需特制三棱镜与待测件。待测样品不一致且过程复杂,测试定标周期长,难于自动化。为了保证待测材料的完整及实现自动化测量,进行了基于平行平板的折射率非接触测量的尝试。运用该方法进行折射率的测量,不需特制三棱镜并且待测件与待测样品一致。分析表明,通过选择合适的测量角度,该方法旋转角度精度为a=0.003(即10),导轨精度为L=0.000 8 mm,平行平板厚度测量精度为d=0.001 mm。  相似文献   

5.
提出了一种可抑制角漂移的表面等离子体传感器结构,并结合相位测量设计了相应的气体折射率测量系统。分析表明激光入射角、金膜厚度以及反射光p、s分量的相位差与气体折射率之间的固有非线性是影响相位响应度与折射率测量精度的主要因素。计算表明所提出的自适应结构将角漂移引起的误差降低了一个数量级并很大程度提高了测量灵敏度。同时分析设计了金膜厚度参数,并评估了反射光p、s分量的相位差与气体折射率之间固有非线性带来的误差。应用于空气折射率的测量比对实验显示其测量精度达到了10-6量级。  相似文献   

6.
周进朝  黄佐华  曾宪佑  张勇 《光学学报》2012,32(12):1212001
依据全反射理论和棱镜耦合原理,实现了对棱镜折射率及波导薄膜材料折射率和厚度的同步测量。使用高准直半导体激光器激光入射到棱镜内部与波导膜的分界面上,逐步旋转棱镜或改变棱镜的入射角,得到棱镜耦合M线,曲线前面几组的波谷为波导模激发,在M线左侧收尾处有一个不完整波峰,其反射光强随入射角迅速衰减,为全反射时的临界点,由此可实现棱镜及波导薄膜参数的同步测量;用此法测量了棱镜耦合一体化平面波导棱镜的折射率和聚甲基丙烯酸甲酯(PMMA)聚合物波导薄膜的折射率和厚度。测量棱镜折射率精度为±1.9×10-4,波导薄膜折射率和厚度的精度分别为±6.2×10-4 μm和±1.6×10-2 μm。  相似文献   

7.
用迈克尔逊干涉仪测量全息干板膜厚度   总被引:4,自引:2,他引:2       下载免费PDF全文
蒋礼  罗少轩  阳艳  杨科灵 《应用光学》2006,27(3):250-253
全息干板膜的厚度是全息干板的重要参数之一。使用迈克尔逊干涉仪和白光光源对2种全息干板膜厚度进行测量,并对测量结果误差进行分析,给出了测量误差与膜厚及折射率之间的关系以及此方法的适用范围。研究结果表明:在膜厚从8μm增至41μm的过程中,测量结果的绝对误差≤2μm且变化很小,相对误差则从14.1%降到了2.2%。随着膜厚的增加,相对误差明显降低;折射率n也参与了误差传递,其值与测量误差呈类似反比关系;当n值在1.5附近时,为保证测量的准确性,所测膜厚≥40μm。最后指出,迈克尔逊干涉仪在测量全息干板膜等较厚的薄膜时,具有测量范围大,结果较准确等优点。  相似文献   

8.
Wan X  Ge J 《Optics letters》2011,36(19):3807-3809
A scanning spatial low-coherence interferometer (S-LCI), using an off-axis converging single wavelength laser beam as the probe, resembles a conventional or temporal low-coherence interferometer (T-LCI) in signal formation and data processing. However, the S-LCI is advantageous over a T-LCI with the combination of angle resolving and depth discrimination capabilities. The S-LCI is demonstrated by measuring the angle dependent phase shifts among the multiple reflections of a glass plate, with incident angles accurately scaled in the Fourier domain. The refractive index and geometric thickness of the glass plate are simultaneously produced in this one-step measurement.  相似文献   

9.
B. Mercier 《Optics Communications》2010,283(14):2900-2907
We present a straightforward method to transform a spatially Gaussian femtosecond laser beam into a flat-top shaped beam. The proposed technique takes advantage of a nonlinear phase induced in positive Kerr medium followed by a simple optical system. The variation of the refractive index with the laser intensity creates a phase plate which induces changes in the beam profile after propagation; flat-top and doughnut profiles are observed. The shaping conditions are computed numerically and confirmed experimentally. The method does not introduce energy losses. The device is very simple, self-regulated, flexible and does not need a manufactured phase plate or precise alignment. This method can be useful for light-matter interaction and laser machining.  相似文献   

10.
With a view to measuring the structure coefficient of refractive index fluctuations in a turbulent premixed butane-air flame, a thin laser beam is sent into the flame perpendicular to the flow direction. The laser beam generally undergoes fluctuations of direction, phase, and amplitude. Only the random deflections of the laser beam may be taken into account. After having traversed the flame, the perturbed laser beam enters into an interferometric system. Materials and experimental procedure are described. In the unperturbed interference pattern, the zones only sensitive to fluctuations of the angle-of-arrival of the laser beam are detected. From the random displacements of the central bright fringe, the structure coefficient of refractive index fluctuations in the flame is measured. To prove that the method of measurement is satisfactory, the result obtained is applied for computing the power spectral density of the angle-of-arrival of the laser beam from the formula of correlations of the laser beam deflection angles which we have demonstrated in previous works. This computed power spectral density is compared to that measured from the effective position of the detector. A good agreement is observed between the two results.  相似文献   

11.
The nonlinear refractive index of benzene is determined by measuring the reduction of the beam divergence of picosecond ruby laser pulses when passing through a benzene sample. Time-integrated spatial beam profiles give an effective refractive index while time-resolved beam profiles measured with a streak camera allow the determination of the temporal evolution of the nonlinear refractive index.  相似文献   

12.
The spherical aberration observed in the far-field diffraction pattern of a He−Ne laser beam traversing a silica plate locally heated by a CO2-laser is investigated. This leads to a thermooptical method suitable to evaluate the effective derivative of the refractive index and elastooptical method suitable to evaluate the effective derivative of the refractive index and elastooptical coefficient.  相似文献   

13.
非线性光栅的自适应光限幅   总被引:1,自引:0,他引:1       下载免费PDF全文
李燕  徐迈  李也凡 《发光学报》2000,21(3):273-275
首次采用液晶为自聚焦媒质,夹在内表面刻有光栅的两玻璃片间,以Ar离子激光514.5nm波长的激光束垂直入射到光栅上,实验验证了该光栅的自适应光限幅特征。  相似文献   

14.
We present a spectral interferometric method to measure the thickness of an optical plate or a film with a single layer. The system is based on the Michelson interferometer configuration, and the spectral interference signal of a broadband light source is recorded by a spectrometer. The optical path difference (OPD) between two interfering beams can be obtained by Fourier transform from the spectral interferogram. Gaussian fitting is used to find the exact peak of fringe to enhance the precision of the measurements. When the sample is inserted into the sample beam, the film’s thickness can be calculated by comparing the change of OPD, provided that the sample group refractive index is known. Only a single measurement is needed to determine a film’s thickness after the initial OPD of the system is calibrated. As no moving parts are required, the system has good stability. In particular, a large range of thicknesses, from micrometers up to several millimeters, can be measured. Such a large range is valuable for optical measurements. For demonstration, we measured the thicknesses of preservative film, cover glass and carrier glass, which were 9.6 ± 0.55, 156.1 ± 0.75, 1008.44 ± 0.96 μm, respectively.  相似文献   

15.
特定折射率材料及光学薄膜制备   总被引:1,自引:0,他引:1  
申振峰 《中国光学》2013,(6):900-905
根据太阳电池阵激光防护膜性能优化的需要,应用离子辅助电子束双源共蒸工艺方法制备了优化设计所需的特定折射率的薄膜材料并用于制备激光防护膜。测试结果显示:用该工艺方法制备的掺杂材料薄膜的折射率n=1.75,与优化设计所需数值相符;激光防护膜性能优良,太阳辐射能透过率提高6%以上,实现了对该激光防护膜性能的进一步优化。为了使该双源共蒸方法适于大面积薄膜的制备,应用均匀性挡板技术来提高该方法制备大面积薄膜的膜厚均匀性,使制备的掺杂材料薄膜在口径为400 mm时的不均匀性小于2.1%。该双源共蒸方法制备工艺简单、可靠,适于实际工程应用。薄膜性能测试结果与理论优化结果相符,达到预期优化目标。  相似文献   

16.
研制了高功率可调谐1064 nm准连续单频激光振荡-放大系统.振荡级采用三镜环形行波腔型结构的Nd:YAG激光器,通过精确控制腔内标准具的温度改变标准具材质折射率和厚度实现了对激光波长的调谐,获得了13.2 W调谐范围为58 GHz的1064 nm准连续单频振荡光,其重复率为1 kHz,占空比为10%.经过由双Nd:YAG激光头串接构成的放大器对振荡光进行双程放大后激光最终输出功率为44 W,光束质量因子M2= 1.58. 关键词: 可调谐激光 单频激光 标准具 振荡-放大系统  相似文献   

17.
於文雪  李松毅 《光学技术》2002,28(6):553-554
采用溶液 凝胶扩散共聚法成功地合成了二元体系的甲基烯酸苄酯 甲基烯酸甲酯 (BZMA MMA)层状梯度折射率板 ,折射率分布是其主要性能指标。给出了一种测量该制品折射率分布的简便实验装置和自动实现方法。该测量方法基于激光干涉的原理 ,由计算机自动跟踪干涉条纹的移动来计算梯度折射率材料的折射率分布。实验表明 ,该方法简单易行 ,具有较高的折射率测量精度 ,为科学评价自研制梯度折射率材料的性能提供了保证  相似文献   

18.
采用提拉法在硅基底上制备了多孔溶胶凝胶SiO2膜,用椭偏法测量薄膜的厚度与折射率,考察了提拉速度和胶体浓度对膜层厚度与折射率的影响。对厚度与提拉速度的关系进行线性与幂函数拟合,并比较分析两种拟合的关系及其对工艺流程的作用。比较了不同浓度胶体所得到的同一厚度薄膜的折射率变化规律。结果表明:对于同一胶体浓度下薄膜厚度与提拉速度的正相关关系,线性拟合相比幂函数拟合可以更好地解释实验结果的规律性。同时,折射率在一定范围内也会随着提拉速度的增加而减小。镀同一厚度膜时,浓度大的胶体膜层折射率大。通过对提拉速度和胶体浓度的控制可以得到理想的薄膜厚度与折射率。  相似文献   

19.
A method for calculating the refractive index of GRIN optical fiber from its transverse interference pattern is presented.In this method the transverse interference fringe pattern through an optical fiber using a sheet of light is applied to get the refractive index profile of it. The optical fiber is not immersed in a matching liquid as used in different techniques [Barakat N, El-Hennawi HA, El-Zaiat SY, Hassan R. Pure Appl Opt 1996;5:27].In this method a sheet of He–Ne laser light is allowed to illuminate the fiber. The light sheet is divided into two parts, the first is refracted through the fiber while the second is used as a reference beam. Interference pattern will be obtained between these two rays displaying the refractive index variation along the fiber radius.The fringe shift of such interference pattern has been measured and used to calculate the deflection angle of light refracted by the fiber and the cladding. An equation is derived to calculate the refractive index profile difference ratio δn at different positions across the fiber cross section in terms of the corresponding deflection angle and is verified experimentally.The optical path difference between these two rays (refracted and reference beam divided by the fiber) has been derived and the fringe shift obtained has been used to calculate the refractive index profile of the fiber.Introducing a ground glass screen on the passage of the two light beams (refracted and reference beam divided by the fiber), two superimposed identical speckle patterns are formed leading to the formation of a third speckle pattern modulated by a grid structure displaying the optical thickness of the fiber.  相似文献   

20.
Correctness of z-scan measurements of nonlinear refractive indices for optical media is considered. It is shown that accuracy of these measurements is greatly affected by the thickness of the nonlinear medium layer (as compared with the diffraction length of the laser beam). Nonlinear refractive indices of nitrobenzene are measured at different laser pulse durations (7 ns and 350 ps); the nonlinearity mechanism is discussed. It is shown that at the pulse duration 350 ps the orientation mechanism of nonlinearity is less effective than at the pulse duration 7 ns due to its time lag. Nonlinear refractive indices are measured for the solution of a new synthesized compound-hexadecabutyl-substituted lutetium diphthalocyanine.  相似文献   