首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 187 毫秒
1.
气相色谱-负化学源质谱快速测定母乳中的多溴联苯醚   总被引:1,自引:0,他引:1  
建立了母乳中8种多溴联苯醚(PBDEs:BDE28,BDE47,BDE99,BDE100,BDE153,BDE154,BDE183,BDE209)的气相色谱-负化学源质谱测定方法(GC-NCI/MS)。样品经索氏提取、酸化硅胶除脂、硅胶氧化铝色谱柱净化后,在7 m长的毛细管气相色谱柱上快速分离,NCI/MS以选择离子监测模式测定目标化合物。其中,三溴~七溴联苯醚采用内标法定量,十溴联苯醚(BDE209)采用同位素稀释法定量。8种PBDEs的检出限为1.74~6.35 pg/g(以脂肪计)。加标回收试验的回收率为61.5%~108%,相对标准偏差为2.06%~10.1%(n=6)。并采用母乳参考物质进一步证实了该方法的准确可靠。该方法提高了BDE209的分析灵敏度,而且分析成本相对较低,分析时间短,适于推广。  相似文献   

2.
Xiao Z  Feng J  Shi Z  Li J  Zhao Y  Wu Y 《色谱》2011,29(12):1165-1172
建立了固相萃取同时提取、净化血清中四溴双酚A(TBBPA)、α, β, γ-六溴环十二烷(HBCD)和8种多溴联苯醚(PBDEs)同系物的样本前处理方法,并结合色谱-质谱分离分析技术检测人血清样本中该类化合物的含量。试样在加入各自的同位素内标物后以甲基叔丁基醚/正己烷(1:1, v/v)混合溶剂进行萃取,再经浓硫酸去除脂肪后,以LC-Si固相萃取柱分离HBCD/TBBPA和PBDEs。采用分步检测的方式,在50 mm长BEH C18反相色谱柱上以超高效液相色谱-串联质谱(UPLC-MS/MS)的多反应监测模式(MRM)检测HBCD和TBBPA,在15 m长的毛细管柱上以气相色谱-负化学源质谱(GC-NCI/MS)的选择离子监测模式(SIM)检测PBDEs。以胎牛血清为空白基质,当HBCD、TBBPA和BDE-209的加标水平为0.5 ng/g和5 ng/g、三溴至七溴联苯醚的加标水平为0.05 ng/g和0.5 ng/g时,它们的平均加标回收率为80.3%~108.8%,相对标准偏差为1.02%~11.42%(n=5);以信噪比(S/N)为3计算,方法的检出限(LOD)为1.81~42.16 pg/g。采用该方法对实际样品进行测定,结果表明,本方法快速、准确、灵敏度高,能够满足血清中HBCD、TBBPA和PBDEs残留的同时提取及测定的要求。  相似文献   

3.
超声辅助萃取气相色谱-质谱法测定松针中的多溴联苯醚   总被引:3,自引:0,他引:3  
陈长二  赵洪霞  谢晴  陈景文 《色谱》2009,27(1):59-62
建立了测定松针样品中多溴联苯醚(PBDEs)的分析方法。松针样品经过正己烷-丙酮(体积比为1∶1)混合溶液超声萃取、浓硫酸和氧化铝柱净化后,采用气相色谱-负化学电离源质谱(GC-NCI-MS)选择离子监测(SIM)模式检测,内标法定量。结果表明,方法的加标回收率为83.8%~107.5%,三溴~七溴代联苯醚的仪器检出限为0.152~ 0.770 pg,十溴代联苯醚(BDE-209)的检出限为11.1 pg;三溴~七溴代联苯醚的方法检出限(湿重)为3~15 pg/g,BDE-209的方法检出限(湿重)为222 pg/g。方法具有良好的重现性、较高的灵敏度和良好的回收率。实际样品分析表明,松针中BDE-209是主要的同类物,约占8种PBDEs总量的82.3%,低溴代联苯醚以2,2′,4,4′-四溴联苯醚(BDE-47)为主。  相似文献   

4.
气相色谱-质谱联用检测塑料产品中溴化阻燃剂   总被引:2,自引:1,他引:1  
建立了气相色谱-质谱联用测定塑料产品中多溴联苯和多溴联苯醚的方法.以甲苯为提取溶剂,超声提取电子电气产品中多溴联苯(PBBs)和多溴联苯醚 (PBDEs),采用气相色谱-质谱法(GC-MS)检测.SCAN和SIM同时扫描,采用质谱特征离子定量分析.结果表明: 9种多溴联苯(PBBs)和10种多溴联苯醚(PBDEs)的线性关系、检出限、回收率和精密度都较好,RSD均<5.0%,PBBs回收率在97%~111%之间;PBDEs回收率在82%~115%之间.本方法前处理简便,灵敏度高,定性、定量分析准确可靠,且分析时间短,适用于塑料产品中PBBs和PBDEs的测定.  相似文献   

5.
气相色谱-负化学源质谱法测定海洋生物中的多溴联苯醚   总被引:1,自引:0,他引:1  
建立了气相色谱-负化学源质谱(GC-NCI-MS) 法分析海洋贝类样品中多溴联苯醚(PBDEs) 的方法. 样品采用索氏提取、多层硅胶柱分离纯化及外标法定量, 7种BDE单体的基质加标回收率平均值为67.4%~101%, 相对标准偏差为4.0%~18%. 对采自大连的白蛤、菲蛤、牡蛎等样品进行分析, 结果表明负化学源分析方法适用于海洋贝类中PBDEs的检测.  相似文献   

6.
建立了固相萃取-浓硫酸净化-气相色谱/三重四极杆串联质谱(SPE-GC-MS/MS)分析水中8种多溴联苯醚(PBDEs,BDE-28,BDE-47,BDE-99,BDE 100,BDE-153,BDE-154,BDE-183和BDE-209)的方法。方法采用改进的色谱柱可同时分析高溴代联苯醚BDE209,采用浓硫酸净化固相萃取后的样品和串联质谱特有的多反应监测模式,可以很好地去除基质干扰和提高定性的准确性。通过优化三重四极杆串联质谱的碰撞电压、扫描峰宽和离子对等条件,使8种多溴联苯醚的检测灵敏度显著提高。8种多溴联苯醚的浓度在0.1~50 ng/mL(BDE209:1~500 ng/mL)范围内线性良好,回归系数均大于0.9997。方法回收率在49%~110%,相对标准偏差在1.4%~6.0%之间。方法可用于实际地表水体中PBDEs的定量检测。  相似文献   

7.
建立了微波辅助萃取-气相色谱质谱法测定生物样品中的多溴联苯醚(PBDEs)的方法,优化了萃取剂的种类、萃取剂用量、萃取时间等微波萃取条件和GC-MS仪器分析条件。正己烷-丙酮混合溶剂提取后,经实验室自制的多层硅胶柱分离纯化,用气相色谱-质谱进行测定,该方法基质加标回收率在60%~77%之间,相对标准偏差在11%~18%之间,方法的检测限为0.03~0.20ng/g,适用于生物样品中PBDEs的测定。  相似文献   

8.
建立了一种同时检测鸡蛋中四溴双酚A(TBBP A)、六溴环十二烷(HBCD)和多溴联苯醚(PBDEs)及其衍生物羟基多溴联苯醚(OH-PBDEs)和甲氧基多溴联苯醚(MeO-PBDEs)的凝胶渗透色谱(GPC)-分散固相萃取(DSPE)-液相色谱-串联质谱(HPLC-MS/MS)和气相色谱-负化学源质谱(GC-NCI/MS)的检测方法。样品经正己烷、二氯甲烷(1∶1,V/V)加速溶剂萃取,凝胶渗透色谱净化后,经100 mg十八烷基键合硅胶(C18)分散固相萃取吸附剂去除杂质,液相色谱-串联质谱和气相色谱-负化学源质谱方法测定,外标法定量。在蛋白和蛋黄样品中添加1.0或5.0μg/kg的目标物,其回收率分别为64.5%~97.2%和65.6%~109.2%(除BDE-85为54.8%,OH-BDE-137为47.4%外),相对标准偏差小于20.2%,定量限为0.01~0.2μg/kg。  相似文献   

9.
高分辨气相色谱-高分辨质谱测定活性污泥中的多溴联苯醚   总被引:19,自引:3,他引:16  
王亚伟  张庆华  刘汉霞  江桂斌 《色谱》2005,23(5):492-495
建立了利用高分辨气相色谱-高分辨质谱定量测定多溴联苯醚(PBDEs)的方法,参与了测定PBDEs的国际比对实验,实验结果表明该法是可行的。对不同地区(北京、山东临沂、上海)的3个污水处理厂的活性污泥进行了索氏提取、多层复合硅胶柱分离,然后用所建立的方法测定了19种多溴联苯醚单体的含量。结果表明,北京某污水处理厂的活性污泥中PBDEs的总量高于其他两者。  相似文献   

10.
建立了大流量采样-气相色谱负化学电离质谱法测定环境空气中痕量多溴联苯醚的方法.用PS-1型大流量空气采样器采集环境空气样品,样品经提取、纯化后采用气相色谱负化学电离质谱法测定环境空气中多溴联苯醚.方法的线性范围在5~10000 pg/m3之间,检出限1~50 pg/m3.用于检测2006年5月在广州市采集的环境空气样品,多溴联苯醚组分含量在5.4~4989 pg/m3范围.该方法适合用于监测环境空气中的痕量PBDEs.  相似文献   

11.
运用气相色谱-离子阱质谱(ion trap mass spectrometry,ITMS)建立了大气中8种多溴二苯醚的二级质谱(MS/MS)检测方法。优化后的MS/MS方法对7种三溴至七溴二苯醚(BDE28、-47、-99、-100、-153、-154、-183)和十溴二苯醚(BDE209)的仪器检出限分别为0.04~0.23 pg和9.38 pg;方法检出限为6.0~27.1 pg/m3和211.6 pg/m3;6点标准曲线相关系数(r)为0.9980~0.9999。方法对8种目标物的加标回收率为79.1%~101.0%,相对标准偏差(RSD)为4.3%~14.3%(n=6)。对6份南京实际大气样品的检测结果表明:离子阱质谱的选择反应监测(selected reaction monitoring,SRM)技术能有效的降低背景干扰。优化后的MS/MS方法对目标化合物有较高的灵敏度,可应用于大气中痕量多溴二苯醚的定量检测。  相似文献   

12.
This study presents a time‐ and solvent‐saving method, pressurized liquid extraction (PLE), to extract polybrominated diphenyl ethers (PBDEs) in sediment samples. The effects of various operating parameters (i.e., extraction solution, temperature, pressure, static/dynamic extraction times) for the quantitative extraction of PBDEs by home‐made PLE were systematically investigated and optimized. The analytes were then identified and quantitated by gas chromatography‐mass spectrometry (GC‐MS) in selected ion monitoring (SIM) mode. The 16 PBDE congeners (from tri‐ to deca‐BDE) can be completely extracted by dichloromethane: n‐hexane (3/2, v/v) at 100 °C and 100 atm combined with 15 min static and then 15 min dynamic extraction steps. Recovery of PBDEs in spiked sediment samples ranged from 52 to 104% with 2‐16% RSD, except for BDE‐206. Limits of quantitation (LOQ) were established between 4 and 400 pg/g (dry weight) in 10 g of sediment sample. The extraction efficiency of the PLE was also compared with the traditional Soxhlet extraction method. The total contents of PBDEs ranged from 8.0 to 37.9 ng/g (dry weight) in various river and coastal sediment samples in Taiwan. Deca‐BDE (BDE‐209) was the major PBDE detected in these sediment samples.  相似文献   

13.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   

14.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

15.
为了研究贵阳市红枫湖底栖生物体中多溴联苯醚(polybrominateddiphenyl ethers,PBDEs)的污染情况,通过索氏抽提、凝胶色谱柱和多层硅胶/氧化铝层析柱净化,对红枫湖底栖生物体中PBDEs的含量、分布模式、来源进行分析。结果表明,红枫湖样品中Σ18PBDEs为105.71~43902.73 pg/g(干重),各单体含量为1.05~20045.38 pg/g。红枫湖底栖生物体中PBDEs的污染尚处于较低水平。  相似文献   

16.
采用全二维气相色谱/飞行时间质谱(GC×GC-TOFMS),建立了鱼肉样品中含卤有机污染物的定性和定量分析方法.鱼肉样品用正己烷丙酮(1∶1,V/V)提取,凝胶色谱和复合硅胶柱净化,浓缩富集,全二维气相色谱联用飞行时间质谱(DB-5MS毛细管色谱柱联HT-8色谱柱)检测.软件自动识别后,经三步筛查,共鉴定出含氯或溴化合物72种,其中包括33种多氯联苯,9种有机氯农药,4种多溴联苯醚,4种DDT代谢产物,2种氯代茴香醚,2种氯苯乙烯,1种氯代茴香硫醚及1种甲基三氯生.另外,从质谱信息上看,有16种化合物明显含氯或含溴,但是因为缺少必要的谱库信息不能准确识别.采用外标定量法,对鱼肉样品中检出的主要的10种多氯联苯和1种多溴联苯醚进行了准确定量分析.  相似文献   

17.
A method has been developed and validated for the concurrent extraction, clean‐up, and analysis of polybrominated diphenyl ethers (PBDEs), α‐, β‐, and γ‐hexabromocyclododecane (HBCD), and tetrabromobisphenol A (TBBPA) in human milk and serum. Milk and serum samples were extracted using accelerated solvent extraction with acetone/hexane 1:1, v/v and liquid–liquid extraction with methyl‐tert‐butyl ether/hexane 1:1, v/v, respectively. The removal of co‐extracted biogenic materials was achieved by gel permeation chromatography followed by sulfuric acid treatment. The fractionation of the PBDEs and HBCD/TBBPA was performed using a Supelco LC‐Si SPE cartridge. The detection of the PBDEs was then performed by GC–MS and that of the HBCDs and the TBBPA was performed using UPLC–MS/MS. The pretreatment procedure was optimized, and the characteristic ions and fragmentation of the analytes were studied by MS or MS/MS. A recovery test was performed using a matrix spiking test at concentrations of 0.05–10 ng/g. The recoveries ranged from 78.6–108.8% with RSDs equal to or lower than 14.04%. The LODs were 1.8–60 pg/g. The usefulness of the developed method was tested by the analysis of real human samples, and several brominated flame retardants in different samples were detected and analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号