排序方式: 共有21条查询结果,搜索用时 125 毫秒
1.
楼建玲 李智焕 叶沿林 江栋兴 华辉 李湘庆 张双全 郑涛 葛愉成 孔赞 吕林辉 李琛 卢飞 范凤英 李忠宇 曹中鑫 马立英 Faisal 徐瑚珊 胡正国 王猛 雷相国 段利敏 肖志刚 黄天衡 付芬 章学恒 郑川 余玉洪 涂小林 张亚鹏 杨彦云 张宏斌 唐彬 田育林 欧阳珍 黄美容 徐治国 岳珂 高启 《中国物理 C》2008,32(Z2):41-43
The β-delayed neutron and γ spectra of neutron-rich nucleus 21N using β-γ and β-n coincidence measurements were presented in this paper. Thirteen new neutron groups ranging from 0.28 MeV to 4.98 MeV and with a total branching ratio 88.7±4.2% were observed. One γ transition among the excited states of 21O, and four γ transitions among the excited states of 20O were identified in the β decay chain of 21N. The ungated half-life of 83.8±2.1 ms was also determined for 21N. 相似文献
2.
3.
设计了中国科学院近代物理研究所利用兰州重离子研究装置(HIRFL)进行浅层肿瘤临床治疗试验研究中所使用的束流诊断安全控制系统。该系统包括束流强度监测及保护、剂量测量、扫描波形监测及保护3个部分。系统基于PXI系统及LabVIEW软件,给出了该系统的各部分结构。从系统建立时的多次测试结果以及实际临床治疗试验研究时的长期运行结果来看,该束流诊断控制系统在控制辐照剂量以及安全保护方面能够满足当前重离子加速器浅层肿瘤临床治疗试验的基本要求,为试验研究的顺利进行提供了可靠的保证。 相似文献
4.
根据几种常用放射性核素的寿命计算方法,通过模拟数据研究了直接拟合法、对数时间法、极大似然法、观测时间受限时的极大似然法等四种寿命计算方法的适用范围。当观测时间不受限时,研究了在不同计数下寿命计算方法的适用范围。当观测时间受限时,研究了在不同观测时间窗口下寿命计算方法的适用范围。模拟中选用全剥离离子94mRu44+作为目标核素,得到了不同计数及不同观测时间窗口下的寿命及其误差,并给出了四种方法的适用范围。94mRu44+寿命的模拟结果与在兰州等时性质量谱仪上获得的实验结果在一倍标准偏差范围内一致,从而进一步验证了寿命计算方法的适用范围及模拟数据的可靠性。该模拟结果可为寿命测量实验设计提供理论依据和参考。 相似文献
5.
A pilot experiment for mass measurement at CSRe 总被引:2,自引:1,他引:1
A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u ^36Ar delivered by CSRm were injected into CSRe. The revolution periods of the stored ions,which depend on the mass-to-charge ratios of the stored ions,were measured with a time-of-flight detector system. The results show that the mass resolution around 8×10^-6 for △m/m is achieved. 相似文献
6.
范凤英 郑涛 叶沿林 江栋兴 华辉 李智焕 葛愉成 李湘庆 楼建玲 史帆 吕林辉 曹中鑫 聂鹏煊 李奇特 宋玉收 卢飞 徐瑚珊 胡正国 王猛 张雪荧 李琛 陈若富 唐彬 徐治国 岳珂 张亚鹏 臧永东 章学恒 姚向武 陈金达 涂小林 张洁 武大鹏 白真 《中国物理快报》2009,26(8):74-77
Differential cross sections for the quasi-elastic scattering of^16 C at 47.5 MeV/nucleon from ^12 C target are measured.Coupled-channels calculations are carried out and the optical potential parameters are obtained by fitting the experimental angular distribution. 相似文献
7.
The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS) in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS, the mass-over-charge ratio is only related to the revolution period of stored ions, and the relative mass resolution can reach up to the order of 10−6. However, the instability of the magnetic field of storage ring deteriorates the resolution of revolution period, making it very difficult to distinguish the ions with very close mass-over-charge ratio via their revolution periods. To improve the resolution of revolution periods, a new method of weighted shift correction (WSC) has been developed to accurately correct the influence of the magnetic field instabilities in the isochronous mass measurements of 58Ni projectile fragments. By using the new method, the influence of unstable magnetic fields can be greatly reduced, and the mass resolution can be improved by a factor up to 1.7. Moreover, for the ions that still cannot be distinguished after correcting the magnetic field instabilities, we developed a new method of pulse height analysis for particle identification. By analyzing the mean pulse amplitude of each ion from the timing detector, the stored ions with close mass-over-charge ratios but different charge states such as 34Ar and 51Co can be identified, and thus the mass of 51Co can be determined. The charge-resolved IMS may be helpful in the future experiments of isochronous mass measurement even for N =Z nuclei. 相似文献
8.
臧永东 武军霞 赵铁成 张生虎 毛瑞士 徐瑚珊 孙志宇 马新文 涂小林 肖国青 F. Nolden P. Hülsmann Yu. A. Litvinov C. Peschke P. Petri M. S. Sanjari M. Steck 《中国物理 C》2011,35(12):1124-1129
A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations. 相似文献
9.
Recent results and progress of mass measurements of neutron-rich nuclei utilizing Isochronous Mass Spectrometry (IMS) based on the HIRFL-CSR complex at Lanzhou are reported. The nuclei of interest were produced through projectile fragmentation of primary 86Kr ions at a realistic energy of 460.65 MeV/u. After in-flight separation by the fragment separator RIBLL2, the fragments were injected and stored in the experimental storage ring CSRe, and their masses were determined from measurements of their revolution times. The re-determined masses were compared and evaluated with other mass measurements, and the impact of these evaluated masses on the shell evolution study is discussed. 相似文献