排序方式: 共有102条查询结果,搜索用时 14 毫秒
1.
2.
3.
4.
5.
Compensation of body shake errors in terahertz beam scanning single frequency holography for standoff personnel screening 下载免费PDF全文
In the terahertz(THz) band, the inherent shake of the human body may strongly impair the image quality of a beam scanning single frequency holography system for personnel screening. To realize accurate shake compensation in imaging processing, it is quite necessary to develop a high-precision measure system. However, in many cases, different parts of a human body may shake to different extents, resulting in greatly increasing the difficulty in conducting a reasonable measurement of body shake errors for image reconstruction. In this paper, a body shake error compensation algorithm based on the raw data is proposed. To analyze the effect of the body shake on the raw data, a model of echoed signal is rebuilt with considering both the beam scanning mode and the body shake. According to the rebuilt signal model, we derive the body shake error estimated method to compensate for the phase error. Simulation on the reconstruction of point targets with shake errors and proof-of-principle experiments on the human body in the 0.2-THz band are both performed to confirm the effectiveness of the body shake compensation algorithm proposed. 相似文献
6.
Chitosan (CS) is expected to be an ideal gene carrier for its high biosafety. In this work, CS with low molecular weight were prepared through the γ-ray radiation on the acetic acid solution of CS. The CS chains were scissioned under the γ-ray radiation, and the molecular weight (MW) of CS decreased with the absorbed dose. When the absorbed dose was above 30 kGy, the molecular weight of CS decreased about an order of magnitude. The γ-ray-radiation-scissioned CS can e ectively bind with plasmid (pEGFP) through complex coacervation method, forming pEGFP/ γ-ray-radiation-scissioned CS complex particles with a size of 200-300 nm. The complex particles have good stability and little cytotoxicity. The in uitro gene transfection efficiencies of the pEGFP/ γ-ray-radiation-scissioned CS complex particles were investigated by fluorescence microscope and flow cytometry. The results showed that the gene vectors using γ-ray-radiation-scissioned CS as the carrier will possess better gene transfection efficiency than those using natural high-MW CS as the carrier. The higher the absorbed dose, the smaller the MW of CS and the better transfection efficiency of the corresponding gene vector. This work provides a green and simple method on the preparation of CS-based gene vectors with high efficiency and biosafety. 相似文献
7.
采用高温固相法制备了Sr_3Y(BO_3)_3:xTm~(3+),yDy~(3+)荧光粉,并通过XRD、SEM和荧光光谱仪对样品的物相、微观形貌、发光性能、能量传递机制和CIE色坐标进行了分析。结果表明:Sr_3Y(BO_3)_3:xTm~(3+)荧光粉在监测波长为359 nm时发射蓝光,Tm~(3+)的浓度淬灭点为x=0.08;在Sr_3Y(BO_3)_3:0.08Tm~(3+),yDy~(3+)荧光粉中,随着Dy~(3+)掺杂浓度的增加,Tm~(3+)的发光强度降低而Dy~(3+)发光强度却先增加后降低,Dy~(3+)的浓度淬灭点为y=0.1;通过改变Dy~(3+)掺杂浓度或改变激发光的波长,均可实现发射光的颜色可调;在Tm~(3+)-Dy~(3+)离子之间存在能量传递。当Dy~(3+)掺杂浓度(物质的量分数)为0.15时能量传递效率达75.14%,能量传递机制为电偶极-电偶极相互作用。 相似文献
8.
以乙二醇为起始原料,依次经亲核取代和点击反应合成了一种7-乙基-10-羟基喜树碱(SN38)的新型葡萄糖残基衍生物(FSY02),其结构经1H NMR, 13C NMR和HR-MS(ESI)表征。采用四甲基偶氮唑盐比色法(MTT法)研究了FSY02对人非小细胞肺癌细胞(A549)、人肝癌细胞(HepG2)、人结直肠癌细胞(SW-480)、人宫颈癌细胞(Hela)和人乳腺癌细胞(MDA-MB-231)的生长抑制作用。并采用Hoechst 33258染色和Western blot技术对给药后的结肠癌细胞凋亡情况和相关凋亡信号通路Caspase 3、 Bax和Bcl-2蛋白的表达情况进行了检测。结果表明:FSY02具有广谱抗癌活性,IC50=0.118~4.295 μmol·L-1,优于对照组伊立替康(IC50=14.330~65.353 μmol·L-1)。 Hoechst 33258染色及Western blot检测结果显示:FSY02通过上调Caspase 3和Bax的表达,下调凋亡抑制蛋白Bcl-2的表达诱导细胞凋亡。 相似文献
9.
SH15树脂吸附胞二磷胆碱的热力学及动力学研究 总被引:2,自引:0,他引:2
静态条件下,研究了SH15树脂吸附水溶液中胞二磷胆碱(CDPC)的热力学和动力学特性.测定了不同温度下,热力学性质的变化.实验结果表明,SH15树脂对CDPC吸附平衡数据符合Langmmuir吸附等温方程,吸附过程为自发的物理吸附过程.考察了温度、溶液浓度、树脂粒径和搅拌速率对吸附过程的影响.运用动边界模型(MBM)描述了SH15树脂吸附CDPC的动力学过程,确定在实验条件范围内,SH15树脂吸附CDPC的吸附速度受颗粒扩散控制,并计算出吸附过程的表观活化能为9.73kJ/mol,反应级数为0.47,速率常数为0.0744,并推导出CDPC:在SH15树脂上的动力学总方程. 相似文献
10.
为了准确、稳定、全面地获得炸药熔铸过程各个位置的温度变化情况,设计了基于布喇格光栅光谱频移的温度实时监测系统。通过光纤组网系统对炸药熔铸过程炸药指定位置的多个点同时进行实时温度监测,根据光栅的布喇格波长与光栅温度之间存在的线性关系,建立光栅布喇格波长线性频移与光栅温度的函数,获取炸药不同位置的准确温度。四个通道通过耦合器共用同一个宽带光源,每一根光纤上的5个光栅的布喇格波长相互分开。实验所用的光栅为自己设计封装好的光栅,用保偏熔接机将光栅与光纤熔接上,经解调仪获取温度数据。将获取的温度数据经Origin处理绘制时间―温度曲线。结果显示,布喇格光栅测得的温度能很好的满足实验要求。 相似文献