共查询到19条相似文献,搜索用时 218 毫秒
1.
以2-硫代巴比妥酸(TBA)修饰金纳米粒子为探针,TBA与三聚氰胺通过氢键作用诱导金纳米探针团聚,进而使金纳米胶体颜色由酒红色变为蓝色。 实验优化得最佳反应条件为在乙酸缓冲溶液(pH=7.0)介质中,室温反应15 min。 对不同浓度三聚氰胺进行检测时发现,在0.062~0.18 μmol/L和0.18~6.0 μmol/L之间,A660/A520吸收比率与三聚氰胺浓度呈现良好的线性关系,检出限为0.043 μmol/L。 该方法用于检测牛奶样品中的三聚氰胺的加标回收率为102.8%~105.3%。 相似文献
2.
表面活性剂增敏荧光光度法测定牛奶中的三聚氰胺 总被引:5,自引:1,他引:4
建立了表面活性剂增敏荧光光度法测定牛奶中三聚氰胺的方法。利用弱碱性介质中阳离子表面活性剂(CTMAB)对三聚氰胺荧光强度的增敏作用,在pH=8.0的Tris-HCl缓冲溶液中,以CTMAB为增敏剂,测定三聚氰胺,线性范围为25~1000μg/L,检出限为19μg/L,相对标准偏差为1.6%。按国标方法处理样品,采用本法测定,回收率偏高;利用自制固相萃取整体柱对牛奶样品进行预处理后,实际样品检测获得满意结果。此方法简便、快捷、准确,可用于大量牛奶样品中三聚氰胺的快速初筛及检测。 相似文献
3.
4.
5.
建立了液相色谱-串联质谱法同时测定牛奶和奶粉中4种青霉素(青霉素G、青霉素V、阿莫西林、氨苄西林)及其4种 β-内酰胺酶酶解产物(青霉素G脱羧噻唑酸、青霉素V脱羧噻唑酸、阿莫西林脱羧噻唑酸、氨苄西林脱羧噻唑酸)残留的方法。样品采用乙腈-水提取,浓缩后经HLB柱净化,用液相色谱-串联质谱检测,外标法定量。结果表明,青霉素原药在4~200 μg/L,酶解产物在10~500 μg/L范围呈良好线性,线性相关系数均大于0.99;样品检出限为5~50 μg/kg(S/N≥3),定量限为8~100 μg/kg(S/N≥10);对牛奶和奶粉样品分别进行3个水平的加标回收实验(n=6),牛奶中青霉素及其酶解产物的平均回收率为83.48%~96.97%,相对标准偏差为3.86%~10.87%;奶粉中青霉素及其酶解产物的平均回收率为82.70%~95.14%,相对标准偏差为3.02%~9.81%。该方法稳定、可靠,适用于牛奶和奶粉中青霉素类药物及其酶解代谢产物的测定。 相似文献
6.
吡啶离子液体双水相-高效液相色谱法同时测定牛奶中3种喹诺酮药物残留 总被引:3,自引:0,他引:3
建立了吡啶离子液体双水相-高效液相色谱同时测定牛奶中噁喹酸、萘啶酸及氟甲喹3种喹诺酮药物残留的方法. 牛奶样品经氯化钠和磷酸混合溶液提取后, 采用吡啶离子液体N-乙基-2-甲基吡啶溴化盐([EMPy]Br)和K2HPO4形成的双水相体系萃取富集, 以0.1%磷酸水溶液-乙腈为流动相, 梯度洗脱, 紫外检测. 该方法对噁喹酸、萘啶酸和氟甲喹测定的线性范围分别为0.3~15, 0.5~20和0.5~25 μg/mL, 相关系数(r)均大于0.9997, 3种药物的检出限在8~10 μg/kg之间. 对不同加标浓度的牛奶样品测定, 绝对回收率均在86.4%~94.8%范围内, 相对标准偏差为3.6%~8.3%. 该方法对牛奶中喹诺酮药物残留的检测具有简单、快速、环保和灵敏度高等优点. 相似文献
7.
8.
9.
10.
11.
固相萃取-亲水相互作用色谱/串联质谱法同时测定食品中三聚氰胺和三聚氰酸 总被引:2,自引:0,他引:2
建立了固相萃取-亲水相互作用色谱/串联质谱同时测定食品中三聚氰胺和三聚氰酸残留量的方法。采用乙腈和水提取试样中残留的三聚氰胺和三聚氰酸,正己烷脱脂,提取液经亲水性键合硅胶和阳离子交换树脂复合填料柱(MCT柱)净化。采用亲水相互作用色谱柱进行分离,质谱采用正、负离子切换模式电离,多反应监测模式检测,同位素内标法定量。三聚氰胺和三聚氰酸在10~2500 μg/L范围内呈线性相关,相关系数(r)均大于0.99,定量限分别为25和50 μg/kg。本方法在动物源性食品、植物源性食品、乳及乳制品等不同样品中的三聚氰胺和三聚氰酸高、中、低3个添加水平的回收率分别在70.0%~129.6%和70.0%~128.6%之间,相对标准偏差分别在1.4%~23.3%和2.8%~18.7%之间。该方法可满足食品中三聚氰胺和三聚氰酸同时定量测定的需要。 相似文献
12.
建立了牛奶和奶粉中三聚氰酸(CYA)的高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品用乙腈提取并沉淀蛋白,经强阴离子交换柱富集和净化,AX色谱柱分离,HPLC-MS/MS法测定,内标法定量。50~2000 μg/L范围内CYA的线性关系良好(r≥0.999);在奶粉和牛奶基质中,添加200、500和1000 μg/kg 3个添加水平的回收率均在97%~121%之间,相对标准偏差(RSD)均小于4.8%;定量限(LOQ)为200 μg/kg。方法的前处理快速简便,净化效果好,准确度和精密度高,可用于牛奶和奶粉中CYA的测定。 相似文献
13.
在系统优化固相萃取吸附剂填料类型、洗脱溶剂种类及体积的基础上,建立了牛奶和奶粉中213种农药残留的气相色谱-三重四极杆串联质谱(GC-MS/MS)方法。试样用乙腈均质提取,采用石墨化炭黑/氨基柱(ENVI-Carb/NH2)净化后,用GC-MS/MS多反应离子监测(MRM)模式进行检测,外标法定量。结果表明,197种农药在10~1000 μ g/L,16种农药在50~1000 μ g/L范围内线性关系良好,相关系数均大于0.99,方法的检出限(S/N=3)为0.03~7.59 μ g/kg,定量限(S/N=10)为0.10~21.94 μ g/kg,平均添加回收率为66.9%~120.1%,相对标准偏差(RSD)为1.23%~17.6%。该方法样品处理简单快速,相比其他多残留分析方法净化效果好,灵敏度和选择性高,适用于日常检测工作。 相似文献
14.
Arnold A Arrey TN Karas M Persike M 《Rapid communications in mass spectrometry : RCM》2011,25(19):2844-2850
A simple, sensitive and fast method for the determination of melamine and its derivatives in milk powder using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed. Neither time-consuming sample preparation, nor special target plates, or other extra equipment are necessary. The common matrix sinapinic acid (SA) was used with a dried-droplet preparation. Detection limits (signal-to-noise (S/N) ratio = 3) for standard solutions of melamine, ammeline and cyanuric acid were 10, 25 and 10 μg/L, respectively. The limit of quantification (LOQ) for melamine was 25 μg/L and excellent linearity (R(2): 0.9990) was maintained over the range of 10-2000 μg/L. Ammeline and cyanuric acid were analyzed with an LOQ of 50 μg/L and also excellent linearity (R(2): 0.9997 and R(2): 0.9998). Good accuracy and precision were obtained for all concentrations within the range of the standard curve. The developed method was successfully used for the determination of melamine, ammeline and cyanuric acid in milk powder samples with a simple sample preparation. The LOQ of melamine was 0.5 μg/g. Ammeline and cyanuric acid were detectable at 0.5 and 5 μg/g. This method showed excellent accuracy, precision and linearity and significantly reduces the needed analysis time, as only approximately 10 s/sample measuring time is required. To the authors' knowledge, this is the first published method to quantify melamine and derivatives by MALDI-TOF-MS. 相似文献
15.
超高效液相色谱-高分辨质谱法筛查婴幼儿配方奶粉中17种头孢菌素类药物残留 总被引:1,自引:0,他引:1
建立了一种快速筛查婴幼儿配方奶粉中17种头孢菌素类药物残留的超高效液相色谱-四极杆/静电场轨道阱高分辨质谱(UHPLC-Q-Orbitrap HRMS)分析方法。奶粉样品经水溶解后,使用乙腈提取除去蛋白质等杂质,经低温高速离心后可达到净化样品的目的。选用C8色谱柱对待测物进行分离,在Q Exactive高分辨质谱Full MS/dd-MS2(data-dependent MS2)扫描模式下采集数据进行定性定量分析。17种目标物在5~200 μg/L范围内线性关系良好,相关系数(r2)均大于0.99,检出限0.0060~0.040 μg/L,定量限0.71~4.6 μg/kg,平均回收率69.6%~101.4%,相对标准偏差(RSDs)均小于10%。该法操作简单,重现性好,分辨率高,适用于婴幼儿配方奶粉中17种头孢菌素类药物残留的定性、定量筛查。 相似文献
16.
17.
磺化改性聚四氟乙烯纤维固相萃取-高效液相色谱联用测定奶制品中的三聚氰胺 总被引:1,自引:0,他引:1
采用新型固相萃取材料磺化的甲基丙烯酸缩水甘油酯接枝聚四氟乙烯(PTFE-g-GMA-SO3H)纤维填充微柱预富集和流动注射(FI)与高效液相色谱(HPLC)联用测定样品中痕量的三聚氰胺。 建立了以该纤维作为吸附剂在线测定奶制品中三聚氰胺的新方法。 对三聚氰胺的富集与洗脱条件进行了优化,并得出三聚氰胺的分析特性:该方法对三聚氰胺的检出限为1.13×10-2 mg/L,富集倍数为300,RSD为7.6%(n=9,三聚氰胺质量浓度为0.2 mg/L)。 该方法应用于2种奶制品中的痕量三聚氰胺的测定,样品加标回收率分别为98%和102.5%。 相似文献
18.
超高效液相色谱-串联质谱法快速测定牛奶中螺虫乙酯及其代谢物残留 总被引:3,自引:0,他引:3
建立了超高效液相色谱-串联质谱快速测定牛奶中螺虫乙酯及其代谢物残留的分析方法。牛奶经乙腈沉淀蛋白质,正己烷脱脂后,采用ESI源,在MRM模式下测定螺虫乙酯及其代谢物。结果表明,在0.5~50μg/L范围内,待测物色谱峰面积与其质量浓度间的线性关系良好(相关系数均大于0.998),检出限(LODs,S/N=3)和定量限(LOQs,S/N=10)分别为0.05~0.30μg/L和0.17~1.00μg/L。当添加水平为1.0、2.0和10μg/L时,方法的加标回收率为80.0%~108.8%,相对标准偏差(RSD)为4.8%~15.2%(n=6)。该法快速,灵敏,准确,能够满足牛奶中螺虫乙酯及其代谢物残留限量的检测要求。 相似文献
19.
建立了婴幼儿配方奶粉中维生素D的液相色谱-大气压化学电离串联质谱(LC-APCI-MS/MS)分析方法。样品经正己烷和甲基叔丁基醚混合溶液提取,ProElut VDC固相萃取柱净化,Kinetex C_(18)色谱柱分离,采用大气压化学电离(APCI)源、正离子扫描和多反应监测(MRM)模式对维生素D_2和维生素D_3进行检测,内标法定量。结果表明维生素D_2和维生素D_3在5~5 000μg/L范围内均具有良好的线性关系,检出限为2μg/kg,定量限为5μg/kg。在5、10和100μg/kg添加水平下,维生素D_2和维生素D_3的回收率为85.2%~105.3%,相对标准偏差为4.7%~8.1%。该方法简便准确,灵敏度高,适用于婴幼儿奶粉中维生素D的测定。 相似文献