1.
电感耦合等离子体质谱法测定花生中稀土元素   总被引:1,自引:0,他引:1  
本文建立了微波消解-八极杆碰撞/反应池(ORS)电感耦合等离子体质谱法(ICP-MS)同时测定花生仁中的La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Tm、Yb、Lu 14种稀土元素的分析方法。样品经微波消解后,在线加入103 Rh内标元素有效消除了非质谱干扰,选用八极杆碰撞/反应池技术有效地消除了质谱干扰。氦碰撞反应气流速为4.5mL/min时背景等效浓度(BEC)最低。结果表明,选择体积比4∶1的HNO3-H2O2体系微波消解充分,14种稀土元素的检出限小于0.0011ng/mL,相对标准偏差(RSD)低于2.60%。该方法具有简单、快速、准确的特点,可作为花生中稀土元素同时测定的可靠方法。  相似文献   

2.
采用微波消解-电感耦合等离子体质谱法测定可食性油墨中的铬、砷、硒、镍、铁、锰、铜、铅、镉、锑、锌、钡和铝等13种化学元素。以硝酸-过氧化氢(3+2)混合液为消解剂对样品进行微波消解,以铋、锗、钪和铟作为内标消除基体干扰,采用碰撞/反应池技术和干扰校正公式消除质谱干扰。各元素的质量浓度在一定范围内与其对应的信号强度呈线性关系,相关系数在0.999 1~0.999 9之间,方法的检出限(3s/k)在0.003~2mg·kg~(-1)之间。加标回收率在80.0%~110%之间,测定结果的相对标准偏差(n=7)在2.3%~7.3%之间。  相似文献   

3.
建立了微波消解–电感耦合等离子体质谱法测定垃圾渗滤液中铜、锌、镍、铬、镉、砷、铅、汞等8种生物毒性元素的含量。以5 mL硝酸及1 mL过氧化氢为消解剂,对垃圾渗滤液样品进行微波消解处理,以45Sc,89Y,115In,209Bi为内标元素消除非质谱干扰,以氦气为碰撞反应气消除质谱干扰,用电感耦合等离子体质谱仪进行定量分析。在1~100μg/L的质量浓度范围内标准工作曲线线性关系良好,相关系数均大于0.999,方法检出限为0.02~0.13μg/L,测定结果的相对标准偏差为1.02%~3.78%(n=6),加标回收率为88.0%~98.8%。该方法检出限低、精密度高,能够满足垃圾渗滤液中上述8种元素的日常分析测定。  相似文献   

4.
电感耦合等离子体质谱法检测氧化镓中杂质元素   总被引:3,自引:0,他引:3  
建立了电感耦合等离子体质谱法(ICP-MS)测定氧化镓中杂质元素的检测方法,采用微波消解技术溶样,以5 ng/mL Rh为内标补偿校正镓基体的抑制效应,采用碰撞室技术(CCT)消除多元素分子离子的干扰.方法的检出限为0.10~1.0 ng/mL,加标回收率在85%~110%之间,RSD为0.6%~7.1%.该方法能满足99.95%~99.995%氧化镓中杂质元素的分析要求.  相似文献   

5.
采用乳化剂和硝酸体系微波消解样品,带八极杆碰撞/反应池(ORS)的电感耦合等离子体质谱(ICP-MS)法同时测定了霜膏类化妆品中铍、硼、铝、钛、铬、锌、砷、硒、银、镉、锡、锑、碘、钕、汞、铊和铅等17种微量元素.通过优化样品前处理和ICP-MS操作条件,降低了质谱干扰,各元素的检出限(3σ)在0.003 ~0.058 ...  相似文献   

6.
用硝酸和过氧化氢在MDS-6型微波消解仪中处理紫甘薯试样,用电感耦合等离子体质谱法测定13种试样中痕量元素的含量。用动态反应池技术消除质谱测定中的光谱干扰。在优化试验条件下,方法的检出限(3S/N)在0.015~1.890μg·L~(-1)范围,方法用于紫甘薯中痕量元素的测定,加标回收率在94%~102%之间。  相似文献   

7.
手工纸样品在190℃微波辅助下,采用硝酸-过氧化氢加热消解,电感耦合等离子体质谱(ICPMS)法同时测定传统手工纸中砷、铅、铬、镍、锑和镉6种重金属元素含量。使用碰撞技术消除ArCl离子对砷的干扰。优化了反应电压(RPq)、碰撞气体流量等测试条件,6种元素仪器检出限在0.003~0.02mg/kg,7次重复性相对标准偏差(RSD)在1.7%~2.6%,分别在样品中加标3和7mg/kg,回收率在88.9%~107%。6批次手工纸样品中有砷、铅、铬、镍和锑元素检出。方法检出限低、快速、准确,适用于传统手工纸中6种杂质重金属元素同时测定。  相似文献   

8.
将烟用香精和料液样品0.3 g(精确至0.001 g)置于全自动石墨消解仪消解罐中,分3次加入消解液(共计10 mL硝酸、1 mL高氯酸),在170℃的最高消解温度下,样品消解完全.所得溶液用水定容至50 mL,采用电感耦合等离子体质谱法(ICP-MS)测定其中砷、铅、镉、铬、镍等元素的含量.以铟为内标,铬、镉、镍、铅、砷元素的测量同位素分别为^(52)Cr、^(111)Cd、^(60)Ni、^(208)Pb、^(75)As,使用动态反应池(DRC)模式消除了铬、砷元素的质谱干扰,铬、镉、镍、铅等元素的测定选择氦气碰撞模式,砷元素的测定选择氢气反应模式.结果表明,5种元素的质量浓度在一定范围内与各元素与内标计数值的比值呈线性关系,检出限(3s)为0.016~0.035 mg·kg^(-1).按标准加入法进行回收试验,各元素回收率为91.5%~111%,相对标准偏差(n=6)为0.28%~3.1%.方法用于10个烟用香精和料液样品的分析,铬、砷、镍的检出量分别为0.019~0.061 mg·kg^(-1),0.039~0.061 mg·kg^(-1)和0.022~0.031 mg·kg^(-1),镉和铅未检出.  相似文献   

9.
微波消解ICP-MS测定海洋沉积物中微量元素   总被引:1,自引:0,他引:1  
采用微波消解-电感耦合等离子体质谱(ICP-MS)法同时测定海洋沉积物中的Cr、Co、Ni、Cu、Zn、Cd、Pb7种微量元素。对微波消解酸体系和微波程序进行了优化,结果表明:由4 mL HNO3与2 mL HF组成的混合酸对沉积物消解效果好;阶段升温,最高温度200℃,消解30 min有着最佳的消解效果。采用本实验方法对7种不同类型的海洋沉积物标准物质进行了测定,测定结果与标准值一致。各元素的检出限在0.009~0.17 ng/g之间。该方法快速简便、准确度高,可用于海洋沉积物样品中多元素同时测定。  相似文献   

10.
0.500 0g醋酸阿比特龙原料药样品经5.0mL硝酸和1.0mL高氯酸微波消解后,加热至近干,将消解液用水定容至25mL,采用电感耦合等离子体质谱法测定其中钯的残留量。采用带有碰撞反应池的氦调谐模式,以相对丰度较高、抗干扰更强的^(105 )Pd作为同位素,以^(115)In作为内标。钯的线性范围在80.0μg·L^(-1)以内,检出限(3.3s/k)为0.020 8μg·L^(-1)。方法用于醋酸阿比特龙原料药样品的分析,测定值的相对标准偏差(n=6)为1.2%,加标回收率为94.0%~100%。  相似文献   

11.
以3 mL HNO3和2 mL H2O2的混合消解液对烟草样品进行微波消解,采用电感耦合等离子体质谱测定了烤烟中的Mn、Zn、Cu、Se、N i、Co、Cr、As、Cd、Pb 10种微量元素的含量.结果表明:方法的检出限均低于0.02μg/g,各元素测定的RSD(n=5)均小于3%,样品加标回收率为97.35%-101.30%.方法消耗试剂少,快速准确,适合烟草中多种微量元素的同时测定.  相似文献   

12.
微波消解-ICP-MS测定塑料原料中14种催化剂残留元素   总被引:1,自引:0,他引:1  
采用微波消解法预处理聚乙烯(PE)、聚丙烯(PP)、聚苯乙烯(PS)、聚对苯二甲酸乙二醇酯(PET)常用塑料原料,使用压力控制装置对消解过程进行监控并对消解条件进行摸索,考察了消解量、消解体系、消解温度和保持时间对消解结果的影响,优化选择了电感耦合等离子体-质谱法(ICP-MS)的测定参数和内标元素。建立了微波消解-电感耦合等离子体-质谱法测定塑料原料中Li、Ca、Mg、Al、Si、Ti、V、Cr、Co、Zn、Ga、Zr、Sb、Hf 14种元素的催化剂残留的检测方法。方法检出限在0.001~10.60μg/L,回收率在82%~120%之间,相对标准偏差小于20%。  相似文献   

13.
通过用四酸与微波消解法溶解样品对比,建立了用硝酸、盐酸、氢氟酸、高氯酸分解样品,采用电感耦合等离子体质谱法(ICP-MS)测定稀土矿中16种元素含量。方法采用103Rh作为内标消除干扰,确定了最优测定条件,16种稀土元素检出限为0.0029-0.0099ng/mL,测定范围为0.0005-0.020%。精密度试验、加标回收试验及标准物质检测,结果验证了方法的可行性及准确性。该方法简单易操作,结果可靠,能满足实验分析要求。  相似文献   

14.
A microwave procedure for the digestion of the NIST 1634b reference material "residual fuel oil" in closed pressurized vessels was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The influence of sample size, reagent composition and volume, microwave power, and duration of heating on the digestion procedure was studied. Pressure and temperature inside the reaction vessels were monitored to determine the progression of the reaction and to develop optimal conditions. A nine-step heating program requiring 36.5 min with microwave power not exceeding 450 W in the pulsed mode was found suitable for the digestion of approximately 250 mg fuel oil with a mixture of nitric acid (5.0 mL) and hydrogen peroxide (2.0 mL). The reproducibility of microwave power was determined in terms of the relative standard deviations (n = 3) for temperature (2.7%) and pressure (4.9%) data. The vapor pressures obtained with 5.0 mL Milli-Q water (heated) in an 80-mL digestion vessel showed good agreement with literature data. The excess acid in the resulting digests was removed by evaporation and the concentrations of 24 elements (Ag, Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mo, Ni, Pb, Sb, Sn, Sr, Ti, Tl, V, U, and Zn) were determined in the diluted digests by inductively coupled plasma mass spectrometry (ICP-MS). The experimental results were in good agreement with the certified and recommended concentrations for eight elements (Al, As, Co, Cr, Ni, Pb, V, Zn) in solutions obtained after one digestion step. An additional digestion step, consisting of intermediate cooling and venting stages, was required for the accurate determination of Fe. No agreement was reached for Ca and Ba even after two-step digestion. The proposed method of digestion provided precise results with relative standard deviations generally less than 5% for most of the elements determined.  相似文献   

15.
A microwave procedure for the digestion of the NIST 1634b reference material “residual fuel oil” in closed pressurized vessels was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The influence of sample size, reagent composition and volume, microwave power, and duration of heating on the digestion procedure was studied. Pressure and temperature inside the reaction vessels were monitored to determine the progression of the reaction and to develop optimal conditions. A nine-step heating program requiring 36.5 min with microwave power not exceeding 450 W in the pulsed mode was found suitable for the digestion of ~ 250 mg fuel oil with a mixture of nitric acid (5.0 mL) and hydrogen peroxide (2.0 mL). The reproducibility of microwave power was determined in terms of the relative standard deviations (n = 3) for temperature (2.7%) and pressure (4.9%) data. The vapor pressures obtained with 5.0 mL Milli-Q water (heated) in an 80-mL digestion vessel showed good agreement with literature data. The excess acid in the resulting digests was removed by evaporation and the concentrations of 24 elements (Ag, Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mo, Ni, Pb, Sb, Sn, Sr, Ti, Tl, V, U, and Zn) were determined in the diluted digests by inductively coupled plasma mass spectrometry (ICP-MS). The experimental results were in good agreement with the certified and recommended concentrations for eight elements (Al, As, Co, Cr, Ni, Pb, V, Zn) in solutions obtained after one digestion step. An additional digestion step, consisting of intermediate cooling and venting stages, was required for the accurate determination of Fe. No agreement was reached for Ca and Ba even after two-step digestion. The proposed method of digestion provided precise results with relative standard deviations generally less than 5% for most of the elements determined.  相似文献   

16.
稀释沥青是一种中间产品,主要用于生产沥青。目前稀释沥青中元素含量的测定方法较少,前处理过程繁琐。本文采用微波消解-电感耦合等离子体质谱法同时测定稀释沥青中铝、钒、铬、锰、铁、钴等23种元素,对研究稀释沥青各元素组成,具有重要意义。通过选择合适的前处理方式,最终采用微波消解稀释沥青,优化样品称样量、消解试剂、赶酸温度,通过引入内标元素对非质谱干扰进行校正,通过调谐优化仪器参数、碰撞反应池He模式、干扰方程、选择合适同位素等手段对质谱干扰进行了校正。样品进行测定时采用45Sc、72Ge、115In、209Bi作为内标元素,对方法的检出限、精密度、准确度等进行考察。在优化的试验条件下,23种元素在一定的质量浓度范围内与其信号强度呈线性关系,标准曲线线性良好,相关系数在0. 9990~1.0000之间,方法的检出限在0.0005~1.02mg/kg之间,方法用加标回收测定回收率,回收率范围在80.0~110.5%之间,对稀释沥青样品平行测定7次,测定值的相对标准偏差在0.47~3.09%之间。利用该方法对进口稀释沥青进行23种元素进行测定,满足国家标准对各项技术指标参数的要求,检出限低,选择性好,结果准确可靠,为稀释沥青类样品中多种元素分析测定提供了新的参考方法。  相似文献   

17.
对未知复杂矿物样品采用扫描电子显微镜-能谱法解析样品,确定基本成分后选择合适的样品前处理方法。实验中采用过氧化钠熔融法熔解样品,用水浸出,硝酸酸化后制备待测样品溶液。以Rh为内标,用八极杆碰撞/反应池(ORS)-电感耦合等离子体质谱(ICP-MS)法测定了复杂样品中的稀土元素。多次测定同一混合标准溶液结果的相对标准偏差(RSD,n=11)小于4%,加标回收率为90%~110%。方法适用于未知复杂矿物中稀土元素的测定。  相似文献   

18.
为提高土壤多元素同时检测的效率,采用超级微波消解-电感耦合等离子体发射光谱法测定土壤中钾、钠、钙、镁、铜、铁、锰、锌、磷、硫、硼、砷、镉、铬、铅、钴、镓、锂等18种元素含量。比较了超级微波消解、常规微波消解和电热板消解的处理效果,采用超级微波消解法对样品进行前处理,并优化了消解条件。在最优条件下,各元素的检出限在0.05~20 mg/kg,加标回收率在86.2%~107.5%,RSD在0.1%~3.0%,方法准确度及精密度可以满足多元素同时测定的需求,且该方法具有简单、快速、成本低、用酸量少、重现性好等特点。  相似文献   

19.
采用微波消解技术,以ICP-AES同时测定原油中V、Ni、Mn、Pb重金属元素的含量。该方法回收率在94.73%~107.2%之间,相对标准偏差小于2.12%,适用于原油中各种重金属元素的测定。采用正交设计法安排实验,可以以少量的实验次数获得大量信息,既节省时间又节约药品。同时利用原油样品中的V/Ni的比值作为参数,可判断原油油源的特征及地质特点。  相似文献   

20.
采用微波消解-电感耦合等离子体发射光谱法(ICP-AES)对化妆品中Ba、Pb、Cd、Sb、Se、Cr、Hg、As8种有毒元素进行同时测定,通过试验确定了仪器参数和各元素的分析线。8种元素的浓度在0~10mg/L均与响应值呈线性关系,相关系数大于0.9995。8种元素测定结果的相对标准偏差均小于10%(n=3),方法检测限小于0.04mg/kg。样品中各元素的加标回收率为82.1%~108.7%。该方法适用于大批量的化妆品检测。  相似文献   