首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This paper compares the extraction effectiveness of six different commonly applied extraction techniques for the determination of PCBs in soil. The techniques included are Soxhlet, Soxtec, ultrasonication extraction, supercritical fluid extraction, microwave-assisted extraction and accelerated solvent extraction. For none of the techniques were the extraction conditions optimized, but instead the extraction parameters were based on the experience from previous successful investigation published by a number of research groups worldwide. In general, all extraction techniques were capable of producing accurate data for one native PCB contaminated soil diluted with another soil sample to obtain two concentration levels. It could therefore be concluded that any of the investigated techniques can be used with success if the extraction conditions applied are chosen wisely.  相似文献   

2.
A selective and sensitive analytical method for determination of ten congeners of polychlorinated biphenyls (PCBs 31, 28, 52, 101, 118, 153, 105, 138, 156, and 180) in mussel samples (Mytilus galloprovincialis) based on accelerated solvent extraction (ASE) and gas chromatography–tandem mass spectrometry (GC–MS–MS) is presented in this work. Extraction conditions were optimised using a Plackett–Burman factorial design. The final extracts were analysed after cleanup on alumina columns. The optimised extraction parameters were solvent percentage, sample amount, extraction temperature, pressure, static extraction time, flush percentage, and purge time. The results suggest that PCBs 118, 105, and 180 extractions appeared affected by only one statistically significant factor, pressure, solvent percentage and static extraction time, respectively. Extraction of PCBs 138 and 156 was affected by amount of sample. PCB 138 extraction was also statistically affected by static extraction time and purge time. Quantitative recoveries (64.8–120.3%) were achieved for all PCBs and method precision (RSD < 19%) was satisfactory.  相似文献   

3.
A method was developed for viable and rapid determination of seven polychlorinated biphenyls (PCBs) in water samples with vortex-assisted liquid-liquid microextraction (VALLME) using gas chromatography-mass spectrometry (GC-MS). At first, the most suitable extraction solvent and extraction solvent volume were determined. Later, the parameters affecting the extraction efficiency such as vortex extraction time, rotational speed of the vortex, and ionic strength of the sample were optimized by using a 2(3) factorial experimental design. The optimized extraction conditions for 5 mL water sample were as follows: extractant solvent 200 μL of chloroform; vortex extraction time of 2 min at 3000 rpm; centrifugation 5 min at 4000 rpm, and no ionic strength. Under the optimum condition, limits of detection (LOD) ranged from 0.36 to 0.73 ng/L. Mean recoveries of PCBs from fortified water samples are 96% for three different fortification levels and RSDs of the recoveries are below 5%. The developed procedure was successfully applied to the determination of PCBs in real water and wastewater samples such as tap, well, surface, bottled waters, and municipal, treated municipal, and industrial wastewaters. The performance of the proposed method was compared with traditional liquid-liquid extraction (LLE) of real water samples and the results show that efficiency of proposed method is comparable to the LLE. However, the proposed method offers several advantages, i.e. reducing sample requirement for measurement of target compounds, less solvent consumption, and reducing the costs associated with solvent purchase and waste disposal. It is also viable, rapid, and easy to use for the analyses of PCBs in water samples by using GC-MS.  相似文献   

4.
刘腾飞  杨代凤  章雪明  毛健  董明辉 《色谱》2018,36(10):1028-1037
建立了以羧基化多壁碳纳米管(MWCNTs-COOH)和N-丙基乙二胺(PSA)为分散固相萃取吸附剂的前处理净化技术,结合气相色谱-质谱(GC-MS)同时检测茶叶中18种多氯联苯(PCBs)的方法。茶叶样品经正己烷-丙酮(1:1,v/v)超声提取后,通过甲苯溶剂置换,以MWCNTs-COOH和PSA混合吸附剂净化,采用电子轰击离子源、选择离子监测模式测定,以保留时间和特征离子丰度比定性,基质匹配标准溶液外标法定量。考察了提取溶剂及吸附剂种类和用量、提取时间和净化时间对分析结果的影响,优化了气相色谱-质谱条件,并评估了优化实验条件下的方法性能。在最优实验条件下,18种PCBs在5~500 μg/kg范围内线性关系良好,相关系数(r)不低于0.9998;当加标水平为5、10和100 μg/kg时,3种茶叶基质中18种PCBs的平均回收率为90.7%~115.2%,相对标准偏差(n=5)为0.3%~10.9%;方法的检出限为0.3~1.7 μg/kg,定量限均为5 μg/kg。该方法操作简单、快速,准确可靠、灵敏度高,样品净化效果好,可用于不同种类茶叶基质中18种PCBs的测定。  相似文献   

5.
贻贝中多氯联苯分析的前处理方法研究   总被引:7,自引:0,他引:7  
针对分析贻贝中痕量多氯联苯(PCBs),比较了索氏提取(SE)和加速溶剂萃取(ASE)两种提取方法,结果表明SE对贻贝中7种PCBs(PCB28、PCB52、PCB101、PCB118、PCB153、PCB138、PCB180)回收率范围在96%~125%,ASE回收率范围在102%~115%,两者提取效果相当,但与索氏提取相比,加速溶剂萃取是一种怏速、高效的提取方法此外采用凝胶渗透色谱(GPC)分别与Florisil和C18固相萃取(SPE)小柱联用净化,GPC与Florisil柱联用净化的凹收率范围在90%-112%,GPC与C18柱联用净化的回收率范围在74%-108%,结果表明GPC与Florisil柱联增净化优于GPC与C18柱联用净化。  相似文献   

6.
An alternative method for the extraction of polychlorinated biphenyls (PCBs) in ash samples, which is less time and solvent consuming than Soxhlet extraction, is presented. A study was carried out to evaluate the possibilities of microwave-assisted extraction (MAE) to determine exactly which parameters affect the efficiency of the process, since direct extrapolation of extraction conditions for PCBs in other solid matrices, failed when applied to coplanar congeners in ash samples. Influence of the organic solvent on the yield of the extraction was first evaluated using two ash samples with different percentages of carbon. Once the extraction solvent was fixed, the effects of solvent volume, extraction temperature and extraction time were investigated using an experimental design. It was found that the volume of organic solvent played a more important role in the extraction efficiency than the other factors. In the optimal conditions microwave extractions were performed at 110 degrees C. for 10 min and using 30 ml of toluene. Recoveries higher than 80% were obtained for all the highly chlorinated congeners. including coplanar species, in a spiked ash sample containing a relatively high concentration of carbon. The proposed method was also applied to the determination of PCBs in a reference material of urban dust. Recoveries were similar to those obtained for spiked ash samples.  相似文献   

7.
A sensitive method for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) using alcoholic-assisted dispersive liquid-liquid microextraction (AA-DLLME) and HPLC was developed. The extraction procedure was based on alcoholic solvents for both extraction and dispersive solvents. The effective parameters (type and volume of extraction and dispersive solvents, amount of salt and stirring time) on the extraction recovery were studied and optimized utilizing factorial design (FD) and central composite design (CCD). The best recovery was achieved by FD using 2-ethyl-1-hexanol as the extraction solvent and methanol as the dispersive solvent. The results showed that volume of dispersive solvent and stirring time had no effect on the recovery of PAHs. The optimized conditions were 145 μL of 2-ethyl-1-hexanol as the extraction solvent and 4.2% w/v of salt (NaCl) in sample solution. The enrichment factors of PAHs were in the range of 310-325 with limits of detection of 0.002-0.8 ng/mL. The linearity was 0.01-800 ng/mL for different PAHs. The relative standard deviation (RSD) for intra- and inter-day of extraction of PAHs were in the range of 1.7-7.0 and 5.6-7.3, respectively, for five measurements. The method was also successfully applied for the determination of PAHs in environmental water samples.  相似文献   

8.
A procedure for the multiresidue determination of organochlorine pesticides and polychlorinated biphenyls in fish muscle samples has been developed. The method is based on the microwave-assisted extraction (MAE) of food samples from an acetonitrile-water (95 + 5, v/v) mixture followed by SPE cleanup of the extracts and analysis by GC with an electron capture detector. MAE operational parameters, such as the extraction solvent, temperature, and time, were optimized with respect to the extraction efficiency of the target compounds from food samples with 10-13% fat content. The chosen extraction technique allows reduction of the solvent consumption and extraction time when compared with methods already used. Acetonitrile is a good extraction solvent for low-fat matrixes (2-20% fat content), such as fish samples, because it does not significantly dissolve the highly polar proteins, salts, and sugars commonly found in food and gives high recoveries of a wide polarity range of analytes. For purification, SPE using LC-Florisil was shown to be sufficient for the removal of coextracted substances. Recoveries > 78% with RSD values < 15% were obtained for all compounds under the selected conditions. Method quantification limits were in the 5-10 microg/kg range. The method was applied to the analysis of samples of herring (Clupea harengus) purchased at the local fish market. The method is rapid and reliable for the determination of organochlorine analytes in fish muscle.  相似文献   

9.
Zhang  Peixu  Jin  Yongri  Chen  Jiafeng  Yao  Hua  Zhang  Hanqi  Yu  Aimin  Li  Xuwen 《Chromatographia》2013,76(15):967-974

In this work, a novel method based on ultrasonic-assisted nebulization extraction coupled with solid phase extraction (UANE-SPE) and determined by high performance liquid chromatography was developed for the determination of triterpenoids in root of Euphorbia pekinensis Rupr. The experimental conditions for the UANE-SPE, such as type of extraction solvent, sample amount, type and amount of sorbent, extraction time and volume of the elution solvent, were examined and optimized. The method was successfully applied to determine euphol and tirucallol in the dried root of E. pekinensis Rupr. The recoveries of the analytes were in the range of 89.1–102.0 %. The limits of detection were 12 μg g−1 for tirucallol and 10 μg g−1 for euphol. The extraction yields obtained by the proposed method are higher than those obtained by the conventional extraction methods, such as reflux and ultrasonic-assisted extraction. Compared with the traditional methods, the proposed method can reduce the consumption of the labor, shorten the sample preparation time and increase the efficiencies in the extraction of active constituents from plant materials.

  相似文献   

10.
In this work, a novel method based on ultrasonic-assisted nebulization extraction coupled with solid phase extraction (UANE-SPE) and determined by high performance liquid chromatography was developed for the determination of triterpenoids in root of Euphorbia pekinensis Rupr. The experimental conditions for the UANE-SPE, such as type of extraction solvent, sample amount, type and amount of sorbent, extraction time and volume of the elution solvent, were examined and optimized. The method was successfully applied to determine euphol and tirucallol in the dried root of E. pekinensis Rupr. The recoveries of the analytes were in the range of 89.1–102.0 %. The limits of detection were 12 μg g?1 for tirucallol and 10 μg g?1 for euphol. The extraction yields obtained by the proposed method are higher than those obtained by the conventional extraction methods, such as reflux and ultrasonic-assisted extraction. Compared with the traditional methods, the proposed method can reduce the consumption of the labor, shorten the sample preparation time and increase the efficiencies in the extraction of active constituents from plant materials.  相似文献   

11.
A rapid extraction and cleanup method using selective fabric phase sorptive extraction combined with gas chromatography and mass spectrometry has been developed and validated for the determination of broad polarity spectrum emerging pollutants, ethyl paraben, butyl paraben, diethyl phthalate, dibutyl phthalate, lidocaine, prilocaine, triclosan, and bisphenol A in various aqueous samples. Some important parameters of fabric phase sorptive extraction such as extraction time, matrix pH, stirring speed, type and volume of desorption solvent were investigated and optimized. Calibration curves were obtained in the concentration range 0.05–500 ng/mL. Under the optimum conditions, the limits of detection were in the range 0.009 –0.021 ng/mL. This method was validated by analyzing the compounds in spiked aqueous samples at different levels with recoveries of 93 to 99% and relative standard deviations of <6%. The developed method was applied for the determination of the emerging contaminants in tap water, municipal water, ground water, sewage water, and sludge water samples. The results demonstrate that fabric phase sorptive extraction has great potential in the preconcentration of trace analytes in complex matrix.  相似文献   

12.
The analytical performances of various adsorbents used to clean up an organic extract of biological samples, particularly for the determination of polycyclic aromatic hydrocarbons (PAHs), polychlorobiphenyls (PCBs), both in mussel tissue and in krill samples, are critically compared. DDT and its degradation products, namely DDE and DDD, are also considered. Silica gel, alumina, aminopropyl-silica, cyanopropyl-silica, florisil, graphitized nonporous carbon and silica gel–alumina mixture (3:1) were used for column chromatography cleanup in combination with modified supercritical CO2 as a mobile phase. Recovery and reproducibility were evaluated by analyzing standard solutions and standard reference materials containing various classes of pollutants. A silica gel–alumina mixture was found to be the most effective in the cleanup of organic extracts, allowing quantitative recoveries of all analytes to be obtained. Finally, the application of the optimized procedure to the determination of PCBs in Antarctic krill samples is presented.  相似文献   

13.
An emerging green solvent called a deep eutectic solvent(DES) was applied to the extraction and determination of catechin(C),(+)epicatechin gailate(ECG) and (-)epigallocatechin gallate(EGCG) from Chinese green tea.After evaluating different combinations of them by extraction methods and DESs,a DES-based extraction method was established and optimized by a systematic investigation of the influencing factors.As a result,a total of 3.629,35.25 or 114.2 mg/g catechin,(+)epicatechin gallate or (-)epigaliocatechin gallate were extracted respectively under optimal conditions with extraction efficiencies of 82.7%,92.3% and 97.0%,respectively.By comparing with other common used solvents for extracting catechin compounds,DESs were proved to be potential extraction solvents for bioactive ingredients.  相似文献   

14.
Ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in 10 mL of water samples by gas chromatography-mass-selective detection. After determination of the most suitable solvent and extraction time, several other parameters including solvent volume, centrifugation time and ionic strength of the sample were optimized using a 23 factorial experimental design. The optimized USAEME procedure used 200 μL of chloroform as extraction solvent, 10 min of extraction with no ionic strength adjustment at 25 °C and 5 min of centrifugation at 4000 rpm. The limits of detection ranged from 14 ng L−1 (for PCB153) to 30 ng L−1 (for PCB101). Recoveries of PCBs from fortified distilled water are over 80% for three different fortification levels between 0.1 and 5 μg L−1 and relative standard deviations of the recoveries are below 10%. The performance of the proposed method was compared with those involving traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the real water samples (i.e., tap and well water as well as domestic and industrial wastewaters, etc.) and comparable efficiencies were obtained. The proposed USAEME procedure has been demonstrated to be viable, simple, rapid and easy to use for residue analysis of PCBs in water samples.  相似文献   

15.
This work reports the development of a simple and automated method for the quantitative determination of several contaminants (triazine, phenylurea, and phenoxyacid herbicides; carbamate insecticides and industrial chemicals) and their metabolites in human urine with a simplified sample treatment. The method is based on the online coupling of an extraction column with RP LC separation–UV detection; this coupling enabled fast online cleanup of the urine samples, efficiently eliminating matrix components and providing appropriate selectivity for the determination of such compounds. The variables affecting the automated method were optimized: sorbent type, washing solvent and time, and the sample volume injected. The optimized sample treatment reported here allowed the direct injection of large volumes of urine (1500 μL) into the online system as a way to improve the sensitivity of the method; limits of detection in the 1–10 ng/mL range were achieved for an injected volume of 1500 μL of urine, precision being 10% or better at a concentration level of 20 ng/mL. The online configuration proposed has advantages such as automation (all the steps involved in the analysis – injection of the urine, sample cleanup, analyte enrichment, separation and detection – are carried out automatically) with high precision and sensitivity, reducing manual sample manipulation to freezing and sample filtration.  相似文献   

16.
生物样品中多氯联苯的微波皂化萃取气相色谱法测定   总被引:8,自引:0,他引:8  
以KOH-甲醇-正己烷为皂化萃取溶剂,利用微波皂化萃取-气相色谱法测定了生物样品中的多氯联苯(PCBs),实现了在皂化的同时对待测物的萃取。方法的检出限为质量分数6.25×10  相似文献   

17.
《Analytical letters》2012,45(13):2231-2245
Abstract

A rapid and reliable analytical method, at trace level concentration was developed and validated for monitoring polychlorinated biphenyls (PCBs) in Jordanian surface water. The method combines the advantage of liquid extraction together with gas chromatography‐mass spectrometry (GC/MS) and gas chromatography‐electron capture detector (GC/ECD). The performance of the method was evaluated by analyzing certified reference material (CRM) of the analytes and applied on real water samples collected from different sites in Jordan. A mixture of 60∶40 dichloromethan‐petroleum ether was chosen as a convenient binary solvent for liquid–liquid extraction. The GC conditions for GC/MS were optimized using He as a carrier gas, temperature programming, and chlorpropham as an internal standard (IS).

The conditions for GC/ECD were performed using N2 gas and a temperature program from 160 to 280°C with different increasing rates. The method of GC/MS in the selective ion mode (SIM) gave linear relationships for all PCBs tested between 0.60–6.0 µg/l with R 2=0.9934 (n=7×18). Recoveries from spiked water samples ranged between 87.6 and 91.4%. The mean accuracy and precision obtained were 4.9% and 2.16%, respectively. The mean of detection limit was 0.14±0.04 µg/l. In GC/ECD, linear relationships for all PCBs examined over the range of 0.3–2.4 µg/l was verified as characterized by a linear regression equation and correlation coefficient, R 2=0.9915 (n=12). The average precision and accuracy were 4.86% and 5.21%, respectively. Analyses results clarified that none of the examined Jordanian water samples contained any of the searched for PCBs within the detection limit achieved.  相似文献   

18.
Pressurized liquid extraction (PLE) was optimized and validated for the determination of sulfonamide and macrolide antimicrobials and trimethoprim in sewage sludge samples. A mixture of water/methanol (50:50, v/v) was found as the most efficient extraction solvent. A temperature of 100 degrees C and a pressure of 100 bar were chosen for extraction. Two cycles of 5 min each efficiently extracted at least 97% of the total extractable amount of all studied analytes from activated sludge. The limits of quantification (S/N= 10) varied between 3 and 41 microg/kg dry weight (dw) and the relative recoveries ranged between 78 and 142%. Additionally, the influence of pH and different LC/MS/MS systems on the absolute recoveries was assessed. Of the investigated antimicrobials sulfapyridin, sulfamethoxazole, trimethoprim, azithromycin, clarithromycin and roxithromycin were detected in municipal sewage sludge samples. Concentrations in activated sludge ranged up to 197 microg/kgdw. In comparison, results obtained by ultrasonic solvent extraction were significantly lower for sulfonamides and in tendency lower for macrolides.  相似文献   

19.
李贤波  赵嫚  李胜清  陈浩  沈菁 《色谱》2012,30(9):926-930
建立了快速(quick)、简单(easy)、便宜(cheap)、有效(effective)、可靠(rugged)和安全(safe)(QuEChERS)的分散液-液微萃取(DLLME)-气相色谱快速测定番茄中拟除虫菊酯类农药残留的方法。样品经乙腈提取,N-丙基乙二胺(PSA)净化,采用DLLME富集,用气相色谱法分析。考察了联苯菊酯、甲氰菊酯和氟氰菊酯在番茄中的残留测定,同时考察了萃取剂种类与体积、分散剂体积以及萃取时间等因素对萃取效率的影响,以40 μL氯仿为萃取剂,1000 μL乙腈为分散剂,萃取时间为60 s。结果表明: 3种拟除虫菊酯类农药在番茄中的检出限分别为0.5、0.5、0.3 μg/kg。在1、10和50 μg/kg添加水平下,联苯菊酯、甲氰菊酯和氟氰菊酯在番茄中的平均回收率分别为89%~109%、92.5%~105%和90%~108%,相对标准偏差分别为2.5%~7.6%、2.8%~5.7%、3.8%~9.1%。该方法简便、快速、安全、价格低廉,重现性好,可用于番茄中拟除虫菊酯类农药的快速检测。  相似文献   

20.
Pressurized Liquid Extraction was utilized for the extraction of seven selected polychlorinated biphenyls (28, 52, 101, 118, 153, and 180) from a naturally contaminated fishmeal and two feed samples fortified with a naturally contaminated fish oil sample. In order to assure sufficient extraction efficiencies, the extraction solvent, the extraction temperature, and the flush volume were optimised by a factorial design approach. The results of the analyses revealed that the impact of these parameters on the extraction of PCBs differed depending on which matrix that was analysed. For fishmeal, an elevated extraction temperature was important to obtain the highest values for the recovery rates whereas for the feed samples high extraction efficiencies could be obtained for all temperatures investigated in the study. In addition, the solvent had an impact on the extraction of PCBs, however, the influence was less pronounced than the impact of temperature. The final conditions, resulting in high recovery rates for all PCBs in all matrices, were found to be temperatures above 100°C using n-heptane as extraction solvent, while the flush volume had very limited effects on the extraction efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏