首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
In order to study the transmission properties of multi-charged ion beams between the ECR ion source and the analyzing magnet, a new diagnostic system composed of three Wien-filters with three single-wires has been built and installed on the IMP ECR source test bcnch. The single-wire is used to measure the beam profile and the beam density distribution, and the Wien-filter is used to measure the charge state distribution of ion beam.  相似文献   

2.
The nest generation, superconducting ECR ion source VENUS (Versatile ECR ion source for Nuclear Science) has operated with 28GHz since 2004,and has produced world record ion beam intesities. The VENUS project is focused on two main objectives. First, for the 88-Inch Cyclotron,VENUS will serve as the third injector soures boosting both the energy and itensity of beams available form the facility.Seconly,VENUS also serves as the prototype injector source for a high intensity heavy ion beam driver linac for a next generation radioactive ion beam facility, where the goal is to produce intense beams of medium to low charge states ions such as 240eμA of Xe 20 or 250eμA of U28 to 34 . These high intensity ion beam requerements present a challenge for the beam transport system since the total currents extracte from the ECR ion source reach several mA. Therefore in parallel to io beam develoments,we are also enhancing our ion beam diagnostics devices and are conducting an extensive ion beam simulation effort to improve the understanding of the ion beam ransprot form the VENUS ECR ion source. The paper will give an overview of recent experiments with the VENUS ECR ion source. Since the last ECR ion source workshop in Berkeley in 2004.we have installed a new plasma chamber,which includes X-ray shielding.This enables us to operate the source reliably at high power 28GHz operation.With this new chamber several high intensity beams(such as 2.4mA ofO6 ,600eμA of Ar9 ,etc.) have been produced. In addition, we have started the developent of high intensity uranium beams. For example, 200eμA of U33 and U34 have been produced so far. In respect to high charge state ions,leμA of Ar18 ,133eμA of Ar16 ,and 4.9eμA of U47 have been measured. In addition,ion beam profile meaurements are presented with ,and without the sextupole magnetic field energized. These expeerimental results are being compared with simulations using the WARP code.  相似文献   

3.
The China Spallation Neutron Source (CSNS) is a large scientific facility with the main purpose of serving multidisciplinary research on material characterization using neutron scattering techniques. The accelerator system is to provide a proton beam of 120 kW with a repetition rate of 25 Hz initially (CSNSⅠ), progressively upgradeable to 240 kW (CSNS-Ⅱ) and 500 kW (CSNS-Ⅱ'). In addition to serving as a driving source for the spallation target, the proton beam can be exploited for serving additional functions both in fundamental and applied research. The expanded scientific application based on pulsed muons and fast neutrons is especially attractive in the overall consideration of CSNS upgrade options. A second target station that houses a muon-generating target and a fast-neutron-generating target in tandem, intercepting and removing a small part of the proton beam for the spallation target, is proposed. The muon and white neutron sources are operated principally in parasitic mode, leaving the main part of the beam directed to the spallation target. However, it is also possible to deliver the proton beam to the second target station in a dedicated mode for some special applications. Within the dual target configuration, the thin muon target placed upstream of the fast-neutron target will consume only about 5% of the beam traversed; the majority of the beam is used for fast-neutron production. A proton beam with a beam power of about 60 kW, an energy of 1.6 GeV and a repetition rate of 12.5 Hz will make the muon source and the white neutron source very attractive to multidisciplinary researchers.  相似文献   

4.
The China Spallation Neutron Source (CSNS) is a large scientific facility with the main purpose of serving multidisciplinary research on material characterization using neutron scattering techniques. The accelerator system is to provide a proton beam of 120 kW with a repetition rate of 25 Hz initially (CSNSⅠ), progressively upgradeable to 240 kW (CSNS-Ⅱ) and 500 kW (CSNS-Ⅱ'). In addition to serving as a driving source for the spallation target, the proton beam can be exploited for serving additional functions both in fundamental and applied research. The expanded scientific application based on pulsed muons and fast neutrons is especially attractive in the overall consideration of CSNS upgrade options. A second target station that houses a muon-generating target and a fast-neutron-generating target in tandem, intercepting and removing a small part of the proton beam for the spallation target, is proposed. The muon and white neutron sources are operated principally in parasitic mode, leaving the main part of the beam directed to the spallation target. However, it is also possible to deliver the proton beam to the second target station in a dedicated mode for some special applications. Within the dual target configuration, the thin muon target placed upstream of the fast-neutron target will consume only about 5% of the beam traversed; the majority of the beam is used for fast-neutron production. A proton beam with a beam power of about 60 kW, an energy of 1.6 GeV and a repetition rate of 12.5 Hz will make the muon source and the white neutron source very attractive to multidisciplinary researchers.  相似文献   

5.
A compact laser plasma accelerator(CLAPA) is being built at Peking University, which is based on an RPA-PSA mechanism or other acceleration mechanisms. The beam produced by this laser accelerator has the characteristics of short duration, high pulse current, large divergence angle, and wide energy spectrum. The beam cannot be produced by a normal ion source and accelerator. The space charge field in the initial is very strong.According to the beam parameters from preparatory experiments and theoretical simulations, a compact beam line is preliminarily designed. The beam line mainly consists of common transport elements to deliver proton beam with the energy of 1–50 MeV, energy spread of 0–±1% and current of 0–108 proton per pulse to satisfy the requirement of different experiments. The simulation result of a 15 MeV proton beam with an energy spread of ±1%, current of 400 m A, and final spot radius of 9 mm is presented in this paper.  相似文献   

6.
During the last decades, photocathode rf gun has been proven to be successful in generating the high brightness electron beam (-lnC,-lπ mmmrad,-l ps) which is required by the ILC, XFEL, Thomson scattering x-ra y source, etc. A photocathode rf gun system is built to develop electron source for the Thomson scattering x-ray source at Accelerator Laboratory of Tsinghua University. The system consists of a BNL/ATF-type 1.6 cell S-band rf cavity, a solenoid for emittance compensation, a laser system and some simple equipments for beam diagnosis. The first beam measurements of the photocathode rf gun, including the dark current, transverse beam profile, charge and quantum efficiency, are reported.  相似文献   

7.
In China, polymer radiation processing has become one of the most important processing industries. The radiation processing source may be an electron beam accelerator or a radioactive source. Physical design of an electron beam facility applied for radiation crosslinking is introduced in this paper because of it’s much higher dose rate and efficiency. Main part of this facility is a 10 MeV travelling wave electron linac with constant impedance accelerating structure. A start to end simulation concerning the linac is reported in this paper. The codes Opera-3d, Poisson-superfish and Parmela are used to describe electromagnetic elements of the accelerator and track particle distribution from the cathode to the end of the linac. After beam dynamic optimization, wave phase velocities in the structure have been chosen to be 0.56, 0.9 and 0.999 respectively. Physical parameters about the main elements such as DC electron gun, iris-loaded periodic structure, solenoids, etc, are presented. Simulation results proves that it can satisfy the industrial requirement. The linac is under construction. Some components have been finished. Measurements proved that they are in a good agreement with the design values.  相似文献   

8.
The design of the China Spallation Neutron Source (CSNS) low-energy beam transport (LEBT) line, which locates between the ion source and the radio-frequency quadrupole (RFQ), has been completed with the TRACE3D code. The design aims at perfect matching, primary chopping, a small emittance growth and sufficient space for beam diagnostics. The line consists of three solenoids, three vacuum chambers, two steering magnets and a pre-chopper. The total length of LEBT is about 1.74m. This LEBT is designed to transfer 20mA of H-pulsed beam from the ion source to the RFQ. An induction cavity is adopted as the pre-chopper. The electrostatic octupole steerer is discussed as a candidate. A four-quadrant aperture for beam scraping and beam position monitoring is designed.  相似文献   

9.
The length of electron beam from a photocathode RF gun is determined by a spectrometer, according to the relative energy spread induced by the bunch length during the acceleration in a linac. For a photocathode RF gun, different laser injected phase and beam charge are studied. The compression is changed for the different laser phases, as from 10° to 30°, and the bunch length is lengthened due to the strong longitudinal space charge force, caused by the increased charge.  相似文献   

10.
The Peking University neutron imaging facility(PKUNIFTY),an RFQ-based neutron source, aims at developing industrial applications. During the past 3 y operation, some problems have appeared, such as RF sparking for the RFQ high power operation, full power level instability of RF transmitter, and the misalignment of RFQ electrodes assembling and deformation. The PKUNIFTY upgrade erdeavors to adopt a modest inter-voltage beam dynamics design. The new beam dynamics design of 201.5 MHz RFQ of PKUNIFTY,which accelerates 35 mA of D~+ from 50 keV to 2.0 MeV at 10% duty factor, is performed.The averaged beam will be about 3 mA. The source will deliver a fast neutron yield of 2.5×10~(12)n/s via the duteron-beryllium reaction, which is about 10 times higher than the current status.  相似文献   

11.
The Californium Rare Ion Breeder Upgrade (CARIBU) to the ATLAS superconducting linac facility is currently being commissioned. It provides low-energy and re-accelerated beams of neutron-rich isotopes obtained from 252Cf fission. The fission products from a 252Cf source are stopped in a large high-intensity gas catcher, thermalized and extracted through an RFQ cooler, accelerated to 50 kV and mass separated in a high-resolution separator before being sent to either an ECR charge breeder for post-acceleration through the ATLAS linac or to a low-energy experimental area. This approach gives access to beams of very neutron-rich isotopes, many of which have not been available at low or Coulomb barrier energies previously. These beams provide unique opportunities for measurements along the r-process path. To take advantage of these unique possibility, the reaccelerated beams from CARIBU will be made available at the experimental stations of ATLAS to serve equipment such as Gammasphere, HELIOS and the reaction spectrometers. In addition, the Canadian Penning Trap (CPT) mass spectrometer has been moved to the CARIBU low-energy experimental area and a new injection line has been built. The new injection line consists of a RFQ buncher sitting on a 50 kV high-voltage platform that will accumulate the mass separated 50 kV radioactive beams, cool and extract them as a pulsed beam of 3 keV. This beam can be sent either to a tape station for diagnostics and tuning, or a cryogenic linear trap for preparation before transfer to the high-precision Penning trap where the mass measurements will take place. Initial CARIBU commissioning is proceeding with a 2 mCi source that will be replaced by a 100 mCi source as the commissioning proceeds. Final operation will use a 1 Ci source and attain yield in excess of 107 ions/sec for the most intense beams at low energy, an order of magnitude less for reaccelerated beams.  相似文献   

12.
The ‘charge state breeder’, BRIC (breeding ion charge) is in construction at the INFN section of Bari (Italy). It is based on EBIS scheme and it is designed to accept radioactive ion beam (RIB) with charge state +1 in a slow injection mode. This experiment can be considered as a first step towards the design and construction of a charge breeder for the SPES project. The new feature of BRIC, with respect to the classical EBIS, is given by the insertion, in the ion chamber, of a rf-quadrupole aiming at filtering the unwanted masses and then making a more efficient containment of the wanted ions. In this paper, the breeder design, the simulation results of the electron and ion beam propagation and the construction problems of the device will be reported.  相似文献   

13.
ARIEL front end     
The ARIEL project at TRIUMF will greatly expand the variety and availability of radioactive ion beams (RIBs) (Laxdal, Nucl Inst Methods Phys Res B 204:400–409, 2003). The ARIEL front end connects the two ARIEL target stations to the existing ISAC facility to expand delivery to two and eventually three simultaneous RIB beams with up to two simultaneous accelerated beams (Laxdal et al. 2008). The low-energy beam transport lines and mass separators are designed for maximum flexibility to allow a variety of operational modes in order to optimize the radioactive ion beam delivery. A new accelerator path is conceived for high mass delivery from an EBIS charge state breeder. The front-end design utilizes the experience gained in 15 years of ISAC beam delivery.  相似文献   

14.
The bunching system of the ATLAS positive ion injector (PII) has been improved by relocating the harmonic buncher to a point significantly closer to the second stage sine-wave buncher and the injector LINAC. The longitudinal optics design has also been modified and now employs a virtual waist from the harmonic buncher feeding the second stage sine-wave buncher. This geometry improves the handling of space charge for high-current beams, significantly increases the capture fraction into the primary rf bucket and reduces the capture fraction of the unwanted parasitic rf bucket. Total capture and transport through the PII has been demonstrated as high as 80% of the injected dc beam while the population of the parasitic, unwanted rf bucket is typically less than 3% of the total transported beam. To remove this small residual parasitic component a new traveling-wave transmission-line chopper has been developed reducing both transverse and longitudinal emittance growth from the chopping process. This work was supported by the U.S. Department of Energy under contract W-31-109-ENG-38.  相似文献   

15.
Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion beams ranging from a few keV to a few MeV for research in materials sciences, atomic and molecular physics is described. One of the important features of this facility is the availability of relatively large currents of multiply charged positive ions from an electron cyclotron resonance (ECR) source placed entirely on a high voltage platform. All the electronic and vacuum systems related to the ECR source including 10 GHz ultra high frequency (UHF) transmitter, high voltage power supplies for extractor and Einzel lens are placed on a high voltage platform. All the equipments are controlled using a personal computer at ground potential through optical fibers for high voltage isolation. Some of the experimental facilities available are also described.  相似文献   

16.
The possibility of simultaneously accelerating particles with a range of charge-to-mass ratios ( approximately 20%) to the same energy is proposed and demonstrated for a superconducting linac. Uranium ions stripped in a foil with eight charge states have been accelerated through a portion of the ATLAS linac from 286 to 690 MeV, with 94% of the injected uranium in the accelerated beam. Emittance of the resultant beam has been measured and the energy spread was 1.3% compared to 0.4% for a single charge state. This development has immediate application to the high-intensity acceleration of heavy ions that are limited by ion-source intensities, such as the proposed Rare Isotope Accelerator Facility.  相似文献   

17.
Laser ion source (LIS) is the only type of source capable of generating 10–30 mA beams of highly charged ions for the ITEP–TeraWatt (TWAC) accelerator/accumulator facility [B.Yu. Sharkov et al., Nucl. Instrum. Methods Phys. Res. A 415 20 (1998).]. The assembling stage of the new LIS based on 100 J/1 Hz master oscillator–power amplifier CO2-laser system [Yu. Satov, et al., J. Russ. Laser Res. 25(3) 205 (2004).] is in progress at ITEP now. In the first phase, the ion beam parameters (charge state distribution, current, pulse length and emittance) will be specified for different elements and target irradiation conditions. According to the planning, the new LIS and the new high-current injector [D. Kashinsky, et al., Proceedings of the Heavy Ion Fusion Conference, Moskow (2002).] will be used to deliver the beams of highly charged ions for the ITEP–TWAC accelerator/accumulator facility.  相似文献   

18.
在中国工程物理研究院流体物理研究所自行研制的负氢潘宁型离子源上进行负氢束流引出测量实验,采用单电极、双电极、三电极束流引出测量方法进行初步束流引出测量,束流强度的实验测量结果远远高于空间限制流的理论计算值。因此,提出一种电屏蔽盒的直流束流引出测量方法。阐述了电屏蔽盒直流束流引出测量的基本方法、束流轨迹的CST数值模拟以及束流引出测量实验结果。研究表明:引出电压为2 kV,引出间隙为3 mm,磁感应强度为0.435 T时,得到较为精确的负氢束流引出强度约100 A。通过空间电荷限制流的V3/2定律进行拟合,推算得到引出电压为40 kV时,负氢束流强度约达到4 mA。  相似文献   

19.
A laser ion source (LIS), which can provide a carbon beam with highly stripped state (C6+) and high intensity (several tens mA), would significantly change the overall design of the hadrontherapy facility. The proposed LIS based hadrontherapy facility has the advantages of short linac length, simple injection scheme, and small synchrotron size. With the experience from the DPIS and HITFiL projects that have been conducted in IMP, a conceptional design of the LIS based hadrontherapy facility will be presented, with special attention given to APF type IH DTL design and simulation.  相似文献   

20.
This work presents the characteristics of a high frequency ion source operating on a low energy, 150 keV accelerator. The latter is to be used as a neutron generator and its design is based on a theoretical analysis which shows that if the axial potential in an electrostatic electrode system is made to increase with four thirds the power of axial distance, inward electric forces will compensate space charge forces tending to blow up the beam. This results in a simplified acceleration tube much shorter and of higher gradient than the conventional acceleration columns. The ion source itself is an ordinary type using axial extraction of the beam, and its main properties investigated are the beam current and beam quality (or emittance). Dependence of the two on different parameters is investigated in a series of tests.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号