首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 125 毫秒
1.
曹丽玲  王可  王小青 《光谱实验室》2012,29(5):3242-3245
建立了电感耦合等离子体-质谱法(ICP-MS)测定尿中碘含量的方法.采用内标法和标准加入法测定尿中碘含量,样品无需前处理,2%硝酸溶液稀释后直接测定.该方法线性范围为2-60.00μg/L、相关系数为0.99995、回收率为95.2%-98.0%、相对标准偏差为1.07%-1.42%、检出限为0.0900μg/L,定量限为0.30μg/L.用ICP-MS和国标方法同时测定9份样品中碘含量,结果经配对T检验,T=1.8007,P>0.05结果差异无统计学意义.ICP-MS测定尿碘方法简便、快速、灵敏度高、干扰少、适合尿中碘含量的测定.  相似文献   

2.
研究了氢化物发生-原子荧光光谱法测定螺旋藻中Pb的适宜条件,分析了酸度、硼氢化钾和基体改进剂浓度、载气流量、灯电流以及原子化器高度等对测定的影响,优选了测定条件.结果表明,铅发生氢化物反应条件为酸性介质,1.5%的盐酸作载流,硼氢化钾还原剂浓度为20g/L,载气流量为500mL/min,空心阴极灯灯电流为60mA,原子化器高度为10mm,此时荧光值强度较大且稳定.最佳测定条件下,其线性范围为0-100ng/mL,相关系数0.9994,仪器检出限为0.383μg/L,相对标准偏差为1.39%,回收率为88.9%-95.9%.用标准物质进行对照,其测定值在给定的标准值不确定度范围之内.对螺旋藻中铅的测定,结果令人满意.  相似文献   

3.
对苯酚红褪色分光光度法测定小麦粉中痕量溴酸钾进行了研究。实验考察了各种因素如酸度、苯酚红的浓度和用量、反应时间和温度等对测定的影响。结果表明,在最优化的实验条件下(最大吸收波长为504nm,0.5mol/L盐酸,1.00mL 1.00×10-4mol/L苯酚红,85℃水浴条件下加热10min),溴酸钾在0—0.45μg/mL范围内符合比耳定律,线性回归方程为ΔA=0.6094C-0.0013(C:μg/mL,相关系数r=0.9991),摩尔吸光系数ε=3.6×106L.mol-1.cm-1,检出限为0.01μg/g(取样量5g)。将该法用于小麦粉中痕量溴酸钾的测定,样品加标回收率在93%—103%,相对标准偏差RSD<5%,结果满意。  相似文献   

4.
对罗丹明B荧光猝灭法测定饮用水中溴酸根的含量进行了研究.考察了酸度、罗丹明B的浓度、反应时间和温度等对测定结果的影响,得到了最优化的实验条件:最大激发波长为557nm,最大发射波长为582nm,反应介质为3.00mL 2mol/L HCl,罗丹明B浓度为1×10-4mol/L,反应时间为30min,反应温度为70℃.在优化的实验条件下,溴酸根在0-2.0μg/25mL之间存在线性关系,相关系数为0.9979,检出限为2.08ng/mL,将该方法用于饮用水中溴酸根的测定,样品加标回收率为85%-115%.  相似文献   

5.
采用电位法对矿石中碘含量进行测定.在加热条件下,加入一定浓度的盐酸对矿石进行溶解、过滤,收集滤液,用电位法测定其中碘含量.研究结果表明,该方法的最低检出限为20μg/g,加标回收率为98.85%-102.94%,相对标准偏差在2.23%-2.67%之间,测定结果准确、可靠,具有良好的应用前景  相似文献   

6.
采用原子荧光光谱法对由人参根、茎、花提取的人参皂苷进行重金属含量的测定,为生产厂家提供科学数据。结果表明As、Hg、Se、Cd元素分别在0—0.10μg/mL、0—1.0ng/mL、0—10ng/mL、0—1.0ng/mL范围呈良好的线性关系,检出限分别为0.17ng/mL、0.10ng/L、0.011ng/mL、0.61ng/L。此法操作简便,灵敏度高,测定结果令人满意。  相似文献   

7.
李艳霞  谢建平  任凯 《光谱实验室》2011,28(6):2917-2920
稀硫酸介质中,基于痕量铜(Ⅱ)对溴酸钾氧化鸡冠花红褪色反应具有较强的催化作用.建立了一种高灵敏度测定痕量铜(Ⅱ)的新催化动力学法.在优化条件下,方法的线性范围为0.0024-0.56μg/mL,检出限为4.4×10-7g/L用于水样中痕量铜(Ⅱ)的测定,结果满意.  相似文献   

8.
靛红-过硫酸钠体系催化动力学光度法测定土壤中镍(Ⅱ)   总被引:1,自引:0,他引:1  
基于聚乙二醇(PEG)对Ni2+催化过硫酸钠(Na2S2O8)氧化靛红褪色反应的增敏效果,建立了一种新的测定Ni2+的增敏动力学光度法。确定了最佳的褪色反应条件为:1.0×10-3mol/L靛红2mL、4.0×10-3mol/LNa2S2O81.5mL、PEG4000.5mL;反应温度为75℃。该方法的线性范围为1.0—10.0μg/25mL,检出限为4.8×10-2μg/mL。催化反应为一级反应,表观活化能为58.17kJ/mol,表观反应常数为2.15×10-4s-1。方法用于土壤中镍测定,结果满意。  相似文献   

9.
酶催化荧光光谱法测定盐酸多巴胺   总被引:1,自引:0,他引:1  
利用盐酸多巴胺对血红蛋白酶催化荧光体系的猝灭作用,建立了酶催化荧光光谱法测定盐酸多巴胺的新方法.研究了该猝灭体系的最佳实验条件及动力学行为,测定的线性范围为2.1×10-8--8.4×10-4mol/L,检出限为8.2×10-9mol/L.对浓度为5.2×10-6mol/L的盐酸多巴胺进行11次平行测定,其相对标准偏差...  相似文献   

10.
反相流动注射催化光度法测定NO-2的研究   总被引:2,自引:0,他引:2  
基于亚硝酸根在酸性条件下对溴酸钾氧化胭脂红酸的褪色反应的催化作用 ,将反相流动注射技术与催化光度法相结合测定亚硝酸根的含量。对实验条件进行了优化。室温下 ,当 [KBr O3 ]=0 .14 mol/L,[胭脂红酸 ]=3.2× 10 -4mol/L,[H2 SO4]=1.4 mol/L时 ,方法的线性范围为 1— 10 ng/m L,检出限为0 .7ng/m L。用于几种河水水样测定 ,结果满意。  相似文献   

11.
李志洲 《光谱实验室》2010,27(5):1691-1697
采用Fenton试剂对模拟染料废水的降解效果进行研究。结果表明,H2O2投加量、Fe2+投加量、pH值条件、超声处理时间的改变对染料废水的处理效果影响很大。对酸性染料:当pH为4.5,30%H2O2投加的体积分数为30mL/L,Fe2+投加的质量浓度为400mg/L,反应时间为40min时为降解反应的最佳操作条件。对碱性染料,正交试验表明当pH为4、30%H2O2投加的体积分数16mL/L、Fe2+投加的质量浓度为300mg/L、反应时间为60min时为降解反应的最佳操作条件,其降解率达98.46%,COD的去除率达到96.7%。  相似文献   

12.
Sensitive and simple spectrophotometric (Method I) and spectrofluorimetric (Method II) methods were developed and validated for the determination of oxybutynin HCl (OXB) in its dosage forms. The method was based on the reaction of OXB with malonic acid anhydride in acetic acid anhydride to form a highly yellow colored product that was measured at 375 nm spectrophotometrically. The same reaction product exihibits strong fluorescence that was measured at 440 nm after excitation at 390 nm. The factors affecting formation and stability of the reaction product were carefully studied and optimized, and the reaction mechanism was postulated. The absorbance-concentration plot is rectilinear over the range 4–40 μg/mL with LOD of 1.12 μg/mL and LOQ of 3.39 μg/mL. The fluorescence-concentration plot is rectilinear over the range 0.5–6 μg/mL with LOD of 0.11 μg/mL and LOQ of 0.33 μg/mL. The method was applied to the analysis of commercial tablets Detronin® and Uripan®. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. The study was extended to content uniformity testing.  相似文献   

13.
黄美珍  潘燕琼  洪茵 《光谱实验室》2011,28(3):1179-1181
研究了钙离子与酸性铬蓝K的反应条件,建立了一种负吸光度法测定钙离子的新方法,钙量在0.0-2.4μg/mL范围内与负吸光度呈线性关系,检出限为2.3×10<'-5>g/L,方法应用于牛奶中钙离子的测定,结果满意.  相似文献   

14.
分光光度法测定甜叶菊废渣中总黄酮的研究   总被引:1,自引:0,他引:1  
为建立测定甜叶菊废渣中总黄酮含量的方法,通过比较直接法、AlCl3法和NaNO2-Al(NO3)3-NaOH法三种显色方法的紫外可见光谱,确定甜叶菊废渣中总黄酮含量测定的最佳方法为NaNO2-Al(NO3)3-NaOH法。分析了测定波长,显色剂用量和反应时间、温度、pH等因素对测定的影响,并从浓度与吸光度的线性关系,稳定性及加标回收率等方面对该法进行了系统研究,结果表明:在波长500 nm处,以芦丁为标准品,在2~24 μg·mL-1范围内呈良好的线性关系,线性相关系数R2=0.999 5。样品加标回收率在96%~104.3%之间,相对标准偏差(RSD)为3.75%。NaNO2和Al(NO3)3的用量都为1.0 mL,反应时间都为6 min,NaOH的用量为15.0 mL,反应时间为15 min。整个显色过程温度为40 ℃,pH为5,进一步优化了NaNO2-Al(NO3)3-NaOH法测定甜叶菊废渣中总黄酮含量的工艺条件。该方法简便快速,重现性好,准确度高,可用于实际检测工作。  相似文献   

15.
杨兵  彭传友  彭斌  夏兰 《光谱实验室》2011,28(6):2952-2956
采用紫外分光光度法对嘉陵江水中亚硝酸盐氮的含量进行定量分析。优化测定条件,得最佳测定条件为:氢氧化锌处理水样,1g/L碱性品红2.00mL,反应时间20min。测得水样中亚硝酸盐氮平均含量为2.875mg/L。该方法试剂无毒,操作简便快捷,干扰小,适合水质中亚硝酸盐氮的定量分析。  相似文献   

16.
段全晓  蒋锋  周健 《光谱实验室》2010,27(3):881-883
基于在硫酸介质中,痕量甲醛与过量重铬酸钾反应,剩余重铬酸钾在酸性条件下与碘化钾反应生成单质碘,利用碘与淀粉显色,生成蓝色络合物在596nm处有最大吸收,建立了碘-淀粉分光光度法测定甲醛含量,并讨论了反应介质、试剂用量、反应温度、反应时间及共存离子的影响,确定了最佳反应条件。实验结果表明:体系褪色程度与溶液中甲醛量在0.225—7.875μg/mL范围内时符合朗伯-比耳定律,线性回归方程为A596=0.1476C(μg/mL)+0.00199,相关系数为0.9994,表观摩尔吸光系数为4.428×103L·mol-1.cm-1。该法用于空气中的甲醛含量测定,结果与酚试剂法测定结果一致,RSD小于2.0%。  相似文献   

17.
傅应强  姚岚  陈宁生 《光谱实验室》2011,28(4):1654-1658
在酸性介质中,F e(Ⅲ)能够催化H2O2氧化中性红褪色反应,而对苯二酚和邻苯二胺都能阻抑该催化氧化褪色反应的速度。但二者存在一定的速率差异,且吸光度的加和性不佳。结合人工神经网络提出了一种能同时测定对苯二酚和邻苯二胺的新方法。研究了最佳反应和测定条件,结果表明:1.0×10^-3m o.lL-1中性红溶液用量为0.8mL;30%H2O2用量为0.6mL;0.100g.L-1F e(Ⅲ)标准溶液用量为0.5mL;0.06m o.lL-1HC l用量为0.8mL;反应时间为6m in;反应温度为75℃时为最佳反应和测定条件。用于混合样品及河水中对苯二酚和邻苯二胺的测定,混合样品中对苯二酚和邻苯二胺回收率分别为95.6%—104.0%、97.8%—104.4%。河水中对苯二酚和邻苯二胺加标回收率均为105%,5次平行测定相对标准偏差分别为3.2%和2.5%。结果满意。  相似文献   

18.
基于在稀盐酸介质中 ,抗坏血酸可抑制碘离子催化氯胺 T氧化孔雀绿褪色的反应 ,建立了一种动力学光度法测定抗坏血酸的新方法。该方法线性范围为 0— 10μg/m L ,检出限为 1.2× 10 -7g/m L。用于药品中抗坏血酸的测定 ,获得了令人满意的结果。并对反应的机理进行了探讨。  相似文献   

19.
Folin-Ciocalteu法测定竹叶中总多酚含量   总被引:2,自引:0,他引:2  
喻谨  岳永德  汤锋  姚曦  王进 《光谱实验室》2013,(6):2752-2758
建立了竹叶中总多酚含量的Folin-Ciocalteu比色测定方法.以没食子酸为对照品,对竹叶中总多酚含量测定的比色条件,包括检测波长、碳酸钠溶液用量、Folin-Ciocalteu试剂用量、反应温度及时间对吸光度的影响进行了研究.结果表明:在0.944-7.552μg/mL范围内,对照品校准曲线为y=0.1237x+0.0469,R2=0.9991,线性关系良好.优化的测定方法为样品提取液0.5mL,Folin-Ciocalteu试剂1.0mL、16%碳酸钠溶液4.0mL、30℃避光反应1.5h,此条件下平均回收率为105.2%(RSD=4.225%).采用建立的检测方法,测定了12种竹叶中总多酚含量,结果表明竹叶中总多酚平均含量为3.265mg/g;含量最高为龙竹6.059mg/g,最低为佛肚竹0.968mg/g.该方法简便快速、结果准确、重现性和稳定性好,可用于竹叶中总多酚含量的测定.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏