首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
Summary A new expression which permits the prediction of the net retention volumes in gas chromatography with column packings of coated porous polymers is reported. The porous polymers Chromosorb 101 and Chromosorb 102 were used as supports and squalane, Ethofat and Carbowax 20M as stationary phases at three different column temperatures of 80°C, 100°C and 150°C. Several organic compounds of various polarity were used as test compounds and the net retention volumes, VNtheor, have been calculated according to this new expression. The VNtheor values were compared with the experimental net retention volumes, VNexp, and it was found that the difference between these two values is dependent on the type of compound and column packing. Nevertheless, the elution order could be predicted in most cases.  相似文献   

2.
Direct conversion of isothermal to temperature programmed indices is not possible. In this work it is shown that linear temperature programmed retention indices can only be calculated from isothermal retention data if the temperature dependence of both the distribution coefficients and the column dead time are taken into account. Procedures are described which allow calculation of retention temperatures and from these, accurate programmed retention indices. Within certain limits the initial oven temperature and programming rate can be chosen freely. The prerequisite for this calculation is the availability of reliable isothermal retention data (retention times, retention factors, relative retention times, or retention indices) at two different temperatures for one column. The use of compiled isothermal retention indices at two different temperatures for the calculation of retention temperatures and thus temperature programmed indices is demonstrated. For the column for which programmed retention indices have to be determined, the isothermal retention times of the n-alkanes and the column dead time as a function of temperature have to be known in addition to the compiled data for a given stationary phase. Once the programmed retention indices have been calculated for a given column the concept allows the calculation of temperature programmed indices for columns with different specifications. The characteristics which can be varied are: column length, column inner diameter, phase-ratio, initial oven temperature, and programming rate.  相似文献   

3.
黄维雄 《色谱》2020,38(4):399-408
近年来,开管离子色谱(OTIC)的研究已取得重大进展,尤其是兼容OH-淋洗液的OTIC柱的成功研制使OTIC梯度洗脱得以实现。该文介绍了各种OTIC柱的制备和表征方法,涵盖早期的二氧化硅开管柱和新近出现的有机聚合物基质开管柱,对静电乳胶附聚的OTIC柱的一系列表征方法进行了系统阐述,包括开管柱柱容量的实验测定和理论计算方法、固定相相同时填充柱与开管柱之间的联系、柱效改善方法以及开管柱均一性表征等。  相似文献   

4.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

5.
The procedure for calculating linear temperature programmed indices as described in part 1 has been evaluated using five different nonpolar columns, with OV-1 as the stationary phase. For fourty-three different solutes covering five different classes of components, including n-alkanes and alkyl-aromatic compounds, both isothermal and temperature programmed indices were determined. The isothermal information was used to calculate temperature programmed indices. For several linear programmed conditions accuracies better than 0.51T-units were usually obtained. The results are compared with published procedures. It is demonstrated that isothermal retention information obtained on one column can be transferred to another column with the same stationary phase but different column dimensions and/or phase ratio. The temperature programmed indices calculated in this way also have an accuracy better than 0.51T-u. The temperature accuracy and precision of the GC-instrumentation used was of the order of 0.1°C. All calculations can be run with a Basic-programmed microcomputer.  相似文献   

6.
The influence of a water vapor admixture in helium, nitrogen, and carbon dioxide on capacity coefficients of C3−C5 alcohols and pyridine during chromatography process in capillary columns with polar (PEG-20M) and nonpolar (SE-30) stationary phases was studied. The introduction of a water admixture into the carrier gas, increases the capacity coefficient of polar organic compounds on the capillary column with PEG-20M and has almost no effect on this value in the case of SE-30. The change in retention of polar organic compounds on the capillary column with the PEG-20M polar phase occurs due to a change in the properties of the stationary phase when it adsorbs water from the mobile phase. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 11, pp. 2258–2261, November, 1998.  相似文献   

7.
Calixarene-bonded stationary phases in HPLC are known to support additional interactions compared to conventional alkyl-bonded phases (π–π interactions, complex-building interactions). Thus it cannot be presumed that the same mechanisms of retention apply and that retention can be predicted in similar ways. Here 31 solutes of highly various molecular structures have been analysed at different mobile phase compositions (0–98% (v/v) methanol) in order to characterise the chromatographic behaviour of the novel stationary phases and to test the applicability of established models predicting retention factors. The influence of a change of the methanol content is discussed for non-polar, polar and ionic solutes and differences of their behaviour on the differing column types are shown. Additionally estimates about underlying retention mechanisms are given.  相似文献   

8.
土壤淋溶柱色谱中有机调节剂对保留的影响   总被引:1,自引:0,他引:1  
许峰  梁鑫淼  苏凡  林炳承 《色谱》2000,18(1):5-9
 摘要:系统考察了55种非离子型化合物(包括11个氯代苯类、14个烷基苯类、22个多苯和多环芳烃类化合物、8个农药)在土壤淋溶柱色谱和较宽的淋洗剂(甲醇-水)组成范围内容量因子(k')与甲醇体积分数(ψ)的关系。用自制加压装柱机将标准土壤干法装填成10mmi.d.×100mm的液相色谱柱,ψ=00.80的等度淋洗剂的流速1mL·min-1,柱温(25.0±0.1)℃,用UV检测器在线检测。实验表明,logk'=logkw+aψ+bψ2和logk'=logkw-Sψ两式均可以用来描述保留规律,但后者因其计算简  相似文献   

9.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

10.
以双-三氟甲烷磺酰亚胺离子([NTf2-)、三氟甲基磺酸根离子([TFO]-)和六氟磷酸根离子([PF6-)为阴离子,合成了含有丙基、丁基、壬基、乙苯基或氰甲基等阳离子取代基的聚合乙烯基咪唑基离子液体固定相,制备了13种离子液体石英毛细管色谱柱。考察了离子液体固定相结构与色谱柱McReynolds常数、热稳定性和测试化合物保留行为之间的构效关系,研究了阳离子取代基对固定相保留性能的影响规律;同时考察了测试化合物保留指数随温度变化的规律。结果表明,所合成的离子液体固定相具有较强的极性,其保留性能不仅与阳离子取代基的性质密切相关,而且受取代基结构和阴离子影响明显;在考察的温度范围内,测试化合物的保留指数变化规律与传统色谱固定相完全相同。  相似文献   

11.
测定了61个不同类型化合物在6根PEG20M石英毛细管柱上的保留指数(RI),结果表明各柱间RI存在相当大的差异,给RI数据库的应用带来了困难,结合文献数据,从固定液本身、相界面吸附、热力学函数及柱极性的表征等方面探讨其原因,认为以烷烃为主的相界面吸附是影响RI可比性的重要因素,同时柱制备过程带来的影响也不容忽视。  相似文献   

12.
Kováts retention indices for a series of linear, branched, and cyclic alkanes on squalane at any temperature, and on other stationary phases of different polarity at a given temperature, are related to physicochemical properties of the solutes, such as boiling point and molar refraction, by multiple regression analysis. The equations found permit calculation of the Kováts retention index for all alkanes, with standard deviations close to experimental error. The same equations can also be used for calculating the physicochemical parameters they contain.  相似文献   

13.
A live retention database for compound identification in isothermal and any step temperature programmed capillary gas chromatography has been developed. The database utilizes the Kovats retention indices of compounds on a given stationary phase and the retention time of n-alkanes measured at isothermal conditions on the column to be used, together with the programming parameters. Identification is performed by search operation that compares the calculated results with the retention values of unknown peaks. Cross-reference of the search results of different operating conditions is performed automatically by the database in order to increase the reliability of the identification. The error of the database conversion is ≤± 0.5 index unit, or ≤± 1% on retention time. This paper describes the principle and the structure of the database in detail. The experimental results for different calsses of compounds tested at divers operating conditions will be presented in Part Ⅱ.  相似文献   

14.
研究了五种有机聚合物固定相的色谱性能.选择在170℃柱温下测定其极性常数,并以下式计算各种填料的极性常数:X′=Ix-653,Y′=Iy-590,Z′=Iz-627,U′=Iu-652,S′=Is-699.式中Ix、Iy、Iz、Iu、Is分别为柱温170℃测得的5种表征物质的保留指数,同时以实验验证了该方法的有效性和实用性.还测定了这些固定相在高纯氮气和空气中的热分析(TG、DTA)曲线,研究了DTA曲线产生峰值的原因,指出了其上限使用温度.扩展了此类固定相的应用范围.此外,还对保留值与柱温的关系进行了研究.  相似文献   

15.
成晓东  李云萍  贺银菊 《色谱》2019,37(7):683-691
将不同比例的氨基和巯基的硅烷偶联剂键合到硅胶表面,再利用巯基与乙烯基膦酸之间的点击化学反应将膦酸基团引入到硅胶表面,制备了一种可调节正负离子比例的两性亲水色谱固定相。通过测定固定相中C、H、N、P元素的含量,证明了氨基与膦酸基团已成功键合到固定相的表面,同时通过N元素与P元素的质量分数确定固定相表面氨基与膦酸基团的比例。制备了3种不同电荷比例的氨基膦酸固定相,将其作为亲水模式下的固定相填料填装在150 mm×4.6 mm不锈钢色谱柱中。以一系列经典的极性小分子作为探针,研究了流动相中乙腈含量、缓冲盐pH值及缓冲盐浓度等因素对探针分子在3种色谱柱上的保留的影响,结果表明,分析物在固定相上是多重保留机理。最后通过比较核苷、水溶性维生素、碱性化合物、苯甲酸这几类标准物质在3种色谱柱上的保留行为来对比3种不同电荷比例的固定相的分离选择性与色谱性能。结果表明,对于不同的分析物,3种固定相表现出完全不同的分离选择性和色谱行为。可以根据分析物的特征选取不同电荷比例的固定相,表明此种固定相在极性化合物的分离上具有良好的应用前景。  相似文献   

16.
Summary Correlations between retention index (RI) and Van der Waals' volume (VW) in homologous series of n-alcohols, n-aldehydes and esters are studied on the stationary phases Carbowax 1540 and squalane. Influence of functional groups is quantified and a method for obtaining one general equation, valid for an indeterminate number of homologous series, is proposed.  相似文献   

17.
Summary The retention of hydrocarbons present in the C5 pyrolysis fraction of gasolines on the stationary phases squalane and methylsilicone oil JXR at 30, 40 and 50°C was investigated by capillary gas chromatography. The unified retention indices of the hydrocarbons were also calculated on squalane. The retention indices obtained on these two phases were interrelated and the quantitative relationship with the structure of the solutes was studied. Equations based on the unified retention indices calculated on squalane and some selected structural elements of the solutes permit the calculation of their retention on methylsilicone with sufficient accuracy.  相似文献   

18.
Equations have been obtained for the dependence of relative retention and retention indexes on average column pressure. The equations suggested conform well with experimental data. It was shown that limiting value of relative retention (at the pressure approaches zero) is an invariant retention value. The nature of the stationary liquid phase used and its film thickness have a substantial influence on the dependence of relative retention and capacity factor on the pressure.  相似文献   

19.
20.
姜舸  沈爱金  郭志谋  李秀玲  梁鑫淼 《色谱》2015,33(9):929-933
糖类化合物因其极性强,在反相色谱模式下保留较弱,因此常用亲水作用色谱(HILIC)对其进行分离分析。本文以9种糖类化合物的混合物为研究对象,系统评价了其在Click TE-Cys亲水色谱柱上的保留行为,分别考察了流动相中有机相比例和盐浓度对其保留行为的影响。实验证明:9种糖类化合物按极性由小到大的顺序依次从Click TE-Cys色谱柱上被洗脱下来。随着有机相比例的增加,糖类化合物的保留增强;随着盐浓度的增加,除唾液酸外的糖类化合物的保留增强。用顶替-吸附液相相互作用模型模拟了糖类化合物在HILIC上的保留行为,采用保留方程ln k=a+blnCB+cCB描述HILIC的保留规律,对HILIC的保留值进行多元线性回归。结果表明糖类化合物在Click TE-Cys色谱柱上的保留行为符合HILIC的保留规律。  相似文献   