首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
建立了大流量空气采样高分辨气相色谱/高分辨质谱(HRGC/HRMS)同时分析测定大气样品中多氯联苯(PCBs)和多溴联苯醚(PBDEs)的分析方法。结果表明在采样过程中污染物没有发生穿透。通过添加 13C同位素标准物质进行评价,PCBs和PBDEs的加标回收率分别为60.7%~121.4%和69.9%~140.4%,均符合美国环保署相关方法的要求。PCBs和PBDEs的方法检出限分别低于0.019 pg/m3和0.189 pg/m3;色谱分离效果良好,可以满足大气样品中PCBs和PBDEs的监测需要。  相似文献   

2.
A comprehensive, sensitive and high-throughput liquid chromatography–atmospheric pressure photoionization tandem mass spectrometry (LC–APPI-MS/MS) method has been developed for analysis of 36 halogenated flame retardants (HFRs). Under the optimized LC conditions, all of the HFRs eluted from the LC column within 14 min, while maintaining good chromatographic separation for the isomers. Introduction of the pre-heated dopant to the APPI source decreased the background noise fivefold, which enhanced sensitivity. An empirical equation was proposed to describe the relation between the ion intensity and dopant flow. The excellent on-column instrument detection limits averaged 4.7 pg, which was similar to the sensitivity offered by gas chromatography–high-resolution mass spectrometry (GC–HRMS). This method was used to analyze a series of fish samples. Good agreement was found between the results for PBDEs from LC–APPI-MS/MS and GC–HRMS.  相似文献   

3.
A comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC x GC-TOF-MS) experimental setup was tested for the measurement of seven 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs), ten 2,3,7,8-substituted polychlorinated dibenzofurans (PCDFs), four non-ortho-polychlorinated biphenyls (PCBs), eight mono-ortho-PCBs, and six indicator PCBs (Aroclor 1260) in foodstuff samples. A 40m RTX-500 (0.18mm I.D., 0.10 microm df) was used as the first dimension (1D) and a 1.5 m BPX-50 (0.10mm I.D., 0.10 microm df) as the second dimension (2D). The GC x GC chromatographic separation was completed in 45 min. Quantification was performed using 13C-label isotope dilution (ID). Isotope ratios of the selected quantification ions were checked against theoretical values prior to peak assignment and quantification. The dynamic working range spanned three orders of magnitude. The lowest detectable amount of 2,3,7,8-TCDD was 0.2 pg. Fish, pork, and milk samples were considered. On a congener basis, the GC x GC-ID-TOF-MS method was compared to the reference GC-ID high resolution mass spectrometry (HRMS) method and to the alternative GC-ID tandem-in-time quadrupole ion storage mass spectrometry (QIST-MS/MS). PCB levels ranged from low picogram (pg) to low nanogram (ng) per gram of sample and data compared very well between the different methods. For all matrices, PCDD/Fs were at a low pg level (0.05-3 pg) on a fresh weight basis. Although congener profiles were accurately described, RSDs of GC x GC-ID-TOF-MS and GC-QIST-MS/MS were much higher than for GC-ID-HRMS, especially for low level pork and milk. On a toxic equivalent (TEQ) basis, all methods, including the dioxin-responsive chemically activated luciferase gene expression (DR-CALUX) assay, produced similar responses. A cost comparison is also presented.  相似文献   

4.
Optimization of the Varian Saturn 2200 ion-trap tandem mass spectrometry (IT-MS/MS) system and comparison of its data quality with two other detection methods [electron-capture detection (ECD) and high-resolution mass spectrometry (HRMS)] was pursued by measuring polychlorinated biphenyls (PCBs) levels in fish and shellfish samples. IT-MS/MS methodology provided limits of detection (LOD) comparable to those obtained by ECD but superior specificity for the detection of a selected number of 39 PCB native congeners and 9 (13)C-labelled PCB standards. The method detection limits (MDLs) established for IT-MS/MS ranged between 1.0 and 5.0 pg/g on a wet weight basis while those obtained by ECD and HRMS were 1.0-4.0 pg/g and 0.1-2.0 pg/g, respectively. Overall, the results obtained in the study demonstrate that gas chromatography (GC) combined with IT-MS/MS provide higher data quality than those achievable by GC-ECD. For this particular set of target analytes the specificity achievable with IT-MS/MS was comparable to that obtained by HRMS and both techniques provided comparable data in terms of accuracy and precision.  相似文献   

5.
多氯联苯(polychlorinated biphenyls,PCBs)是一类包括209种化合物的持久性有机污染物,是斯德哥尔摩公约中优先控制的12类持久性有机污染物之一,曾经大量生产用于变压器和电容器内的绝缘介质、热交换剂、润滑剂、增塑剂等[1],全球共生产150万吨多氯联苯[2-3]。在209种PCBs中有1  相似文献   

6.
我国水产品中多氯联苯(PCBs)的检测方法,主要以6种指示性PCBs和12种二噁英类共平面PCBs为主,仅涵盖有限的PCBs。为更全面地获得生物体中PCBs的浓度水平,深入探讨PCBs在生物体内的代谢和富集特征,进而准确评价PCBs对人类的暴露水平及风险,以鱼和贝类作为生物样品代表,建立了加速溶剂提取-同位素稀释-高分辨气相色谱-高分辨质谱(ASE-ID-HRGC-HRMS)测定生物样品中82种PCBs的方法。比较了振荡提取和加速溶剂提取两种提取方式的回收率和重复性,最终采用正己烷-二氯甲烷(1∶1, v/v)对PCBs进行加速溶剂提取。考察了各流分淋洗液对PCBs的回收率,确定了样品提取液经8 g 44%酸性硅胶层析柱(内径15 mm), 90 mL正己烷洗脱的净化方式。样品提取液净化浓缩后进行HRGC-HRMS分析,色谱柱采用DB-5MS超低流失石英毛细管柱(60 m×0.25 mm×0.25 μm)。通过优化后的升温程序对化合物进行分离,以保留时间和两个特征离子精准定性,采用同位素内标法定量。结果表明,在0.1~200 μg/L范围内,平均相对响应因子(RRF)的相对标准偏差值(RSD, n=7)均≤20%,相关系数(r2)>0.99。生物样品中PCBs的方法检出限为0.02~3 pg/g;鱼类中PCBs平均加标回收率为71.3%~141%, RSD(n=7)为2.1%~14%;贝类中PCBs平均加标回收率为76.9%~143%, RSD为1.4%~11%。该方法灵敏、准确、可靠,可以更加全面具体地分析鱼和贝类等水产品受PCBs的污染情况,为国内外开展生物监测提供有效的技术支持,从而服务于相关生态环境管理及履行《斯德哥尔摩公约》。  相似文献   

7.
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二噁英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMSPowerPrep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。13C同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。  相似文献   

8.
A screening method using gas chromatography/mass spectrometry in the single ion monitoring (SIM) mode for the routine congener-specific analysis of polychlorinated biphenyls (PCBs) in human serum has been developed and validated. A fast procedure incorporating both liquid-liquid and solid-phase extraction was used for clean up and enrichment. Interday and intraday precision and accuracy were assessed for the 12 congeners having dioxin-like activity and PCBs #180 and #170 by analyzing spiked samples on three subsequent days and using (13)C(12)-labelled analogues as internal standards. Furthermore, the relative errors for six non-dioxin-like congeners (PCBs #28, #52, #101, #138, #153 and #180) were measured by using certified reference materials, providing good accuracy at two different concentration levels. The limits of quantification and of detection were 0.5 and 0.2 micro g/L in serum for each congener, respectively. The method allows the chromatographic separation of at least 35 congeners and can therefore be applied to the routine monitoring of the general population for both dioxin-like and non-dioxin-like PCB congeners.  相似文献   

9.
样品采用索氏抽提,抽提液依次经酸性硅胶床、多段混合硅胶柱和凝胶渗透色谱柱(GPC)净化后,用Florisil硅藻土柱分离出样品中的二噁英(PCDD/Fs)和类二噁英多氯联苯(dioxin-like PCBs),采用同位素稀释法和气相色谱/高分辨质谱联用仪(GC/HRMS)测定了其中的17个2,3,7,8-氯取代二噁英类化合物和12个类二噁英多氯联苯。结果表明,用该法分析二噁英和多氯联苯标准溶液,平行4次的分析结果为:RSD(PCDD/Fs)<8.9%,RSD(PCBs)<11.4%;回收率可达60%-105%。PCDD/Fs和PCBs的检出限分别为0.1-0.8 pg/g和0.05-0.6 pg/g。应用本方法成功测定了沉积物、淤泥、土壤和飞灰中的二噁英和类二噁英多氯联苯,并计算出它们的毒性当量。  相似文献   

10.
Although the two flame retardants 1,2-dibromo-4-(1,2-dibromoethyl)cyclohexane (TBECH) and 1,2,5,6-tetrabromocyclooctane (TBCO) have been widely used, a selective instrumental method of analysis for these compounds has not been developed to date. In this study, we demonstrate the feasibility to utilize liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the separation and analysis of α- and β-TBCO and α-, β-, γ-, and δ-TBECH. Acetone was initially used in a tetrahedron solvent system for LC optimization. A simple isocratic elution allowed near-baseline separation of these compounds. Different ionization approaches and mechanisms were investigated. The mass spectrometric transition of [M + O(2)](-) => Br(-) (459.8 => 78.9) was a selective detection method for the target analytes. Good instrument detection limits (5 pg for γ-/δ-TBECH, 125 pg for α-/β-TBECH, and 30 pg for α-/β-TBCO with 2.0 μL injection) were obtained. Excellent linearity up to 50 ng/μL (R(2) >0.999) was also achieved. This method has been applied to environmental samples (surface water) for screening purposes with recoveries ranging from 76-92% (CV%: 5-8%). This method shows significant improvement over previous methods.  相似文献   

11.
A fast extraction and clean-up method for the simultaneous determination of PCBs and PBDEs has been developed. The procedure consisted of a solid-phase extraction (SPE) of the analytes on an Oasis HLB cartridge and the subsequent on-line fat elimination by directly dropping the eluate from the SPE cartridge onto a second cartridge containing layers of activated neutral silica gel and sulphuric acid modified silica gel. Detection limits using a gas chromatography coupled with an ion trap detector in the tandem mass spectrometry mode were from 0.03 to 0.3 pg/microL for PCBs and from 0.07 to 1.3 pg/microL for PBDEs. Repeatability (lower than 11%) and reproducibility (lower than 17%), expressed as relative standard deviation (RSD, n=4), were satisfactory. The feasibility of the method developed for the determination of the target compounds was evaluated by participation in several rounds of interlaboratory exercises involving human serum with a wide range of PBDE and PCB concentrations. The method has been applied to the evaluation of PBDEs and PCBs in human serum samples of up to 1 mL.  相似文献   

12.
2014年1月在杭州市选择5个点位采集大气颗粒物PM2.5样品,采用同位素稀释高分辨气相色谱/高分辨质谱测定PM2.5中的二恶英(PCDD/Fs)和多氯联苯(PCBs),对PM2.5的污染状况以及PM2.5中PCDD/Fs和PCBs的污染水平及分布特征进行了研究。PM2.5的质量浓度范围为85~168 μg/m3,PM2.5污染较重,但与2004年同期相比明显降低。PM2.5中PCDD/Fs的毒性当量(TEQ)为0.277~0.488 pg I-TEQ/m3,明显高于2004年同期采集样品。颗粒物中PCDD/Fs以八氯代二苯并-对-二恶英(OCDD)为主,毒性当量主要贡献者为2,3,4,7,8-五氯代二苯并呋喃(2,3,4,7,8-PeCDF)。PM2.5中PCBs的质量浓度范围为2.9~8.1 pg/m3,二恶英类多氯联苯(DL-PCBs)的毒性当量范围为2.6~6.1 fg WHO-TEQ/m3,污染较低。PCBs在颗粒物中分布以PCB-28为主,但对毒性当量贡献最大的为PCB-126。PCDD/Fs和PCBs的气-固分配特征表现为PCDD/Fs主要分布于颗粒物中,而PCBs主要分布于气相中。  相似文献   

13.
We attempted to establish a high‐speed and high‐resolution profiling method for a carotenoid mixture as a highly selective and highly sensitive detection method; the analysis was carried out by supercritical fluid chromatography (SFC) coupled with mass spectrometry (MS). When an octadecyl‐bonded silica (ODS) particle‐packed column was used for separation, seven carotenoids including structural isomers were successfully separated within 15 min. This result indicated not only improved separation but also improved throughput compared to the separation and throughput in RP‐HPLC. The use of a monolithic ODS column resulted in additional improvement in both the resolution and the throughput; the analysis time was reduced to 4 min by increasing the flow rate. Furthermore, carotenoids in biological samples containing the complex matrices were separated effectively by using several monolithic columns whose back pressure was very low. The mass spectrometer allowed us to perform a more sensitive analysis than UV detection; the detection limit of each carotenoid was 50 pg or below. This is the first report of carotenoid analysis carried out by SFC‐MS. The profiling method developed in this study will be a powerful tool for carrying out accurate profiling of biological samples.  相似文献   

14.
Laser ablation inductively coupled plasma mass spectrometry was used for spatially resolved trace element analysis of archaeological samples. An autofocus system was built in order to achieve reproducible ablation conditions. This system allows focusing of any sample automatically, with an accuracy of 10–50 μm, in the focal plane of the laser, or any height specified by the user, and can correct for surface roughness point per point. The applicability of the autofocus system is demonstrated. Trace element determination of archaeological samples with a lateral resolution of 50 μm is shown as an example. Absolute detection limits of 01–1.4 pg are achieved.  相似文献   

15.
This paper describes the determination and quantitation of hexabromocyclododecane (HBCD) enantiomers by liquid chromatography-quadrupole linear ion trap mass spectrometry (LC-QqLIT-MS). The method is based on the use of a chiral chromatographic column Nucleodex beta-PM (200 mm x 4.0 mm, 5 microm), which allows a good separation between HBCD enantiomers [(+/-)alpha, (+/-)beta and (+/-)gamma] in less than 15 min and the detection is performed by a Q-Trap instrument. Linearity was checked between 0.05 and 25 injected ng. Limits of detection (LODs) were in the range of 0.3-1.5 pg, limits of quantification (LOQs) were between 1 and 6 pg, and both values are lower than those published in the literature applying LC-MS-MS methods. The method was applied to sediment samples collected along the Cinca River, a tributary of the Ebro River (northeast of Spain). Samples were extracted and purified following a pressurized liquid extraction method. LODs of the method were between 0.12 and 5.61 ng/g and LOQs, from 0.38 to 1.87 ng/g. Total HBCD levels in these sediments ranged from not detected to 2660 ng/g dry weight. Enantiomeric fractions (EFs) were calculated and compared with EF obtained from standard injections. It is important to note that calculated EFs were corrected using (2)H(18)-labeled HBCD standards, in order to compensate matrix effect. EFs obtained in sediment samples suggested a higher presence of (+)alpha-HBCD and (+)gamma-HBCD in technical mixture, this suggests that it is not a racemic mixture.  相似文献   

16.
高分辨质谱技术在农药残留检测中的应用   总被引:3,自引:0,他引:3  
农药残留检测是农产品中有害物质控制的重要组成部分,随着农药残留限量标准体系的发展完善,农药残留检测方法也在不断进步。近年来质谱技术发展迅速,已被广泛应用于农药残留检测领域,高分辨质谱由于具有较高的分辨率和质量精确度,在复杂基质的农药多残留高通量检测中发挥着越来越重要的作用。本文从高分辨质谱与液相色谱、气相色谱及其他分离模式联用等方面出发,简述了近5年来高分辨质谱在农药残留检测中的应用,对目前高分辨质谱在农药残留检测应用中发现的问题进行了讨论,并对其未来发展趋势进行展望。  相似文献   

17.
采用高分辨气相色谱/高分辨质谱(HRGC/HRMS)定量测定了底泥中的17种2,3,7,8位多氯代二噁英和呋喃(PCDD/Fs) ,并测定了四至八氯取代的二噁英和呋喃总量。样品经加速溶剂萃取,然后通过流体控制系统(FMS)自动过硅胶柱、氧化 铝柱和碳柱净化,最后浓缩。以HRGC/HRMS电压选择离子检测模式对样品中的PCDD/Fs进行了定性分析,采用同位素稀释 技术定量,该方法可精确定量到pg/g水平。结果表明该方法分析的17种二噁英和呋喃异构体的检出限可达0.1 pg/g。同 位素标准的回收率为49.8%~85.3%,样品中各异构体的回收率为93.2%~115.6%。该方法不但满足国际标准的要求,还大 大提高了分析速度,使分析周期从原来的2周缩短到2 d以内。  相似文献   

18.
母乳中多种含卤持久性有机污染物的联合检测方法   总被引:1,自引:0,他引:1  
建立了母乳中多种含卤持久性有机污染物(POPs)的联合检测方法,目标化合物主要包括六溴环十二烷(HBCDs)、多溴联苯醚(PBDEs)、多氯联苯(PCBs)和有机氯农药(OCPs)等.样品的前处理采用液液萃取、凝胶渗透色谱(GPC)净化和固相萃取(SPE)等技术,目标化合物经气相色谱-质谱联用仪(GC-MS)、液相色谱-三重四极杆串联质谱联用仪(LC-MS/MS)和气相色谱-三重四极杆串联质谱联用仪(GC-MS/MS)等进行检测.样品通过GPC除去脂肪,然后经SPE柱进一步净化并进行多组分分离,极大程度地减小了生物样品中复杂基质的干扰,适合样品量相对较小的人体样本中多种超痕量POPs的分析.应用灵敏度高、选择性更好的GC-MS/MS对样品中的PCBs和OCPs等进行分析,进一步降低基质的干扰.方法经过小牛血清加标实验验证,稳定可靠.POPs的加标回收率分别为88.7%~98.8%(PBDEs), 88.5%~92.5%(HBCDs), 67.9%~82.3%(PCBs)和81.7%~116.1%(OCPs),方法检出限分别为0.13~1.8 pg/mL(PBDEs), 0.31~1.2 pg/mL(HBCDs), 0.22~1.4 pg/mL(PCBs)和0.20~1.5 pg/mL(OCPs).采用本方法对潍坊地区20例母乳样品进行分析,结果显示,潍坊市母乳中HBCDs, PBDEs, PCBs、HCHs和DDTs的中值浓度分别为2.86, 7.76, 8.84、140和503 ng/g 脂重,此浓度水平与国内其它地区人群相当.  相似文献   

19.
马畅  曹蓉  孙帅  张海军  陈吉平  熊志立  卢宪波 《色谱》2022,40(10):944-951
建立了一种基于改良QuEChERs的样品前处理新方法,并通过气相色谱-静电场轨道阱高分辨质谱(GC-Orbitrap HRMS)对海参样品中的有机氯农药类(OCPs)、多环芳烃类(PAHs)、酞酸酯类(PAEs)、多氯联苯类(PCBs)及其他农药类(ACs)等10大类289种具有健康风险的有机污染物进行了高通量高精准的定性鉴别和定量分析。通过将传统的QuEChERs方法与柱净化方法结合,提出了一种基于改良QuEChERs的简便生物样品制备新方法,经弗洛里硅土(Florisil)柱净化后脂含量降低了99.9%,显著减少了基质效应对分析结果的干扰,可在高分辨质谱(6万分辨率)全扫描模式下对289种目标化合物同时进行高精准定性筛查和定量分析。该方法定量限约0.56~57.8 pg/g,线性范围约6个数量级,回收率范围为40%~120%。由于Q Exactive GC-Orbitrap HRMS具备较高的质量分辨率和灵敏度,因此对目标化合物的定量限显著优于常规的色谱和质谱分析方法,常规方法无法检出的超痕量有机污染物利用该研究开发的方法可进行精准定量。基于此高覆盖度多目标分析方法对养殖场采集的海参样品进行分析,共从海参体内检出100种有机污染物,其中PAHs、ACs、PAEs、OCPs类检出总含量相对高于其他类污染物,总含量均值分别为157.8、153.2、64.4和46.4 ng/g dw。9-氯芴、5-氯苊、3-甲基胆蒽等多种新污染物首次在海参样品中检出,但含量都非常低。该方法简单高效,定量限低,线性范围宽,结果准确。此高覆盖度多目标分析方法可广泛应用于各种水产品中风险物质的广谱筛查和精准定量,为食品安全和绿色养殖提供技术支撑。  相似文献   

20.
黄雯雯  勾新磊  胡铁靖  胡光辉  赵新颖 《色谱》2018,36(10):985-990
利用高效液相色谱-四极杆/静电场轨道阱高分辨质谱(HPLC-Q/Orbitrap HRMS)测定血清中的胆固醇及其6种代谢标志物(2,4-脱氢胆甾醇、7-烯胆甾醇、菜油固醇、豆固醇、β-谷固醇和角鲨烯)。以乙腈作为提取溶剂,超声提取,采用Acquity UPLC BEH C18色谱柱(100 mm×2.1 mm,1.7 μm),以95%(v/v)的甲醇-乙腈(2:8,v/v)-5%(v/v)水做流动相,等度洗脱15 min,流速0.4 mL/min。在大气压化学电离源(APCI)正离子扫描模式下,质谱采用全扫描/数据依赖二级扫描(Full MS/dd MS2)监测模式,同时获得定性和定量结果,一级分辨率为70000 FWHM,二级分辨率为17500 FWHM。7种目标物质在其线性范围内的线性相关系数(r2)均不小于0.992,检出限为0.8~62.1 μg/L,3个加标水平下的回收率为82.1%~97.5%,相对标准偏差(RSD)为1.6%~7.4%。方法准确、简单、快捷,可以作为血清中胆固醇及其6种代谢标志物的检测方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号