首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
2.
This article presents the results of a noise survey at Johns Hopkins Hospital in Baltimore, MD. Results include equivalent sound pressure levels (L(eq)) as a function of location, frequency, and time of day. At all locations and all times of day, the L(eq) indicate that a serious problem exists. No location is in compliance with current World Health Organization Guidelines, and a review of objective data indicates that this is true of hospitals throughout the world. Average equivalent sound levels are in the 50-60 dB(A) range for 1 min, 1/2, and 24 h averaging time periods. The spectra are generally flat over the 63-2000 Hz octave bands, with higher sound levels at lower frequencies, and a gradual roll off above 2000 Hz. Many units exhibit little if any reduction of sound levels in the nighttime. Data gathered at various hospitals over the last 45 years indicate a trend of increasing noise levels during daytime and nighttime hours. The implications of these results are significant for patients, visitors, and hospital staff.  相似文献   

3.
The characteristics of various types of refrigerator noise were investigated in an anechoic chamber and in a real living environment - a 100 m2 apartment which is a common size in Korea. It was found that the sound pressure level of the refrigerator noise in the real living room was about 10 dB higher than the level in the anechoic chamber at the same position (1 m in front of refrigerator). In addition, a tolerance level for refrigerator noise was determined by subjective evaluation experiments. Refrigerator noise was presented by a loudspeaker placed in the kitchen where the refrigerator is normally located. Level 2 responses to the subjective evaluation (“hardly perceivable”) corresponded to a sound pressure level of about 26 dB(A), for which 90% of participants were satisfied with the level of refrigerator noise. A semantic differential test using various adjectives was also conducted to evaluate the sound quality of refrigerator noise. With the semantic differential and the factor analysis, adjectives used in this experiment were grouped into three factors. From the results of correlation and multiple regression analyses on the psychoacoustical parameters and subjective evaluations of 30 kinds of refrigerators, sound quality index which predict the subjective rating score were proposed.  相似文献   

4.
5.
This paper discusses the practical evaluation of noise levels generated by air-conditioning and ventilating systems inside buildings. The results of this work are incorporated in a Draft Italian Standard. The criterion for evaluation is based on the difference between the total sound pressure level in the room when the noise source is working, and the background noise level. The allowable difference must decrease with the value of the background noise level. The measured sound pressure level is corrected according to the type of noise and to the acoustical characteristics of the room; impulsive noises should not be present in the system.At present this Draft Proposal, which has been developed by a Working Group of the Italian Standard Institution (UNI), is under discussion.  相似文献   

6.
The noise exposure of infants in incubators due to both services noise and self-generated noise has been measured in an investigation involving 45 incubators and 69 infants. Incubator services noise levels were consistent with those reported in previous surveys but the noise produced by the infants has been found to increase levels by approximately 8 dB(A) on average. Statistical distribution analysis of the noise levels has shown that energy content of the infant generated noise has maximum values between 90 dB(A) and 100 dB(A) and peak levels of 107 dB(A) have been recorded. The possibility of the measured sound pressure levels inducing cochlear damage is discussed and an assessment is made of incubator services noise which suggest a design level of 45 dB(A) for new incubators and a limiting sound level of 55 dB(A) during normal usage.  相似文献   

7.
The sound power of a number of test objects was determined from spatially averaged intensity measurements. The results show that the influence of room acoustics is insignificant even for rooms of widely different room constants, if the measuring surfaces are exactly defined and if a good space-averaging technique is used. The intensity integrated over a closed surface defining a source-free space compared to the sound pressure integrated over the same surface gives a measure of the capability of a specific intensity measuring system to suppress external noise. For the test arrangements measured with broad band noise, this suppression was found to be 14–18 dB(A). A similar value of 15 dB was found from sound power measurements on a source with high external sound and an analysis of the results in one-third octave bands. From these measurements an analytical function was derived which describes the average error of the spatially averaged intensity as a function of the difference between the external sound level and the source sound level. For practical measurement situations a further analytical function was derived which gives this intensity error as a function of the difference between the measured (spatially averaged) pressure and intensity levels. Thus it is possible to estimate the error of intensity measurements directly from measured intensity and pressure data.  相似文献   

8.
In order to further define in the literature the characteristics for different noise environments existing in industry over 2000 work stations in eleven different industries were investigated. The data measured included dB(A) sound levels and octave band sound pressure levels. These data are analyzed with respect to mean slope, mean slope as related to dB(A) sound level, flatness, bands of concentrated acoustic energy (or pure tones) and the correlation between the measured dB(A) sound level and that predicted by using the measured octave band sound pressure levels.  相似文献   

9.
People increase their vocal output in noisy environments. This is known as the Lombard effect. The aim of the present study was to measure the effect as a function of the absorption coefficient. The noise source was generated by using other talkers in the room. A-weighted sound levels were measured in a 108 m(3) test room. The number of talkers varied from one to four and the absorption coefficients from 0.12 to 0.64. A model was introduced based on the logarithmic sum of the level found in an anechoic room plus the increasing portion of noise levels up to 80 dB. Results show that the model fits the measurements when a maximum slope of 0.5 dB per 1.0 dB increase in background level is used. Hence Lombard slopes vary from 0.2 dBdB at 50 dB background level to 0.5 dBdB at 80 dB. In addition, both measurements and the model predict a decrease of 5.5 dB per doubling of absorbing area in a room when the number of talkers is constant. Sound pressure levels increase for a doubling of talkers from 3 dB for low densities to 6 dB for dense crowds. Finally, there was correspondence between the model estimation and previous measurements reported in the literature.  相似文献   

10.
Today, analyzing of sound pressure level and frequency is considered as an important index in human society. Sound experts believe that analyzing of these parameters can help us to better understanding of work environments. Sound measurements and frequency analysis did to fix the harmful frequency in all sections in Shiraz gas power plant with sound analyzer model BSWA 308. The sound pressure levels (LP) and the one and one-third octave band were continuously measured in A and C weighting networks and slow mode for time response. Excel 2013 and Minitab 18.1 software used for statistical calculations. Results analyzed by Minitab 18.1 software. The highest harmful frequency in Shiraz Gas Power Plant (SGPP) was 50 Hz with 115 dB. The sound pressure level (SPL) ranged from 45 dB to 120 dB in one-third octave band and weighting network C. The maximum sound pressure level was in Craft electricity generator with 105.3 dB and 67 Hz. Sound pressure level in surrounded environment was 120 dB. According to the results, in this industry the sound pressure level exceeded the Occupational Exposure Level of Iran (OEL). The value of sound pressure level were higher than the Standard of occupational health. SGPP consumes 47000 cubic meters of natural gas per hour to produce 100 MW (Mega Watt) of electricity. It is very high and it is not economical and cost effective. These numbers indicate that the power plant’s efficiency is low. It could be concluded that the noise pollution is an important issue in these industries. Moreover, SGPP produce noise with loss energy. Frequencies rotation at high sound pressure levels toward low frequencies were happened.  相似文献   

11.
Patients and staff in hospitals are exposed to a complex sound environment with rather high noise levels. In intensive care units, the main noise sources are hospital staff on duty and medical equipment, which generates both operating noise and acoustic alarms. Although noise in most cases is produced during activities for the purpose of saving life, noise can induce significant changes in the depth and quality of sleep and negatively affect health in general. Results of a survey of hospital staff are presented, as well as measurements in two German hospital wards: a standard two-bed room and a special intermediate care unit (IMC-Unit), each in a different intensive care unit (ICU). Sound pressure data were collected over a 48 hour period and converted into different levels (L(AFeq), L(AFmax) L(AFmin), L(AF 5%)), as well as a rating level L(Ar), which is used to take tonality and impulsiveness into account. An analysis of the survey and the measured data, together with a comparison of thresholds of national and international regulations and standards describe the acoustic situation and its likely noise effects on staff and patients.  相似文献   

12.
The dB(A) sound level of a noise is accepted as a measure of the damage risk to unprotected ears but often it is not a reliable guide to the risk to ears fitted with hearing protectors. For any dB(A) level inside a protector, normally there will be substantially higher sound levels outside that protector. This paper shows how, from sequential frequency attenuation bands of the protector, and sound level weightings, external sound levels can be calculated, below which the noise inside the protector does not exceed a chosen dB(A) level. Further valuable information may be obtained by mapping external dB(A) and dB(C) levels to cover all possible noise spectra that give the chosen dB(A) level inside the protector. Thus, from a pair of measured sound levels, use of the method indicates whether the protector is sufficient or not, or whether more detailed measurment of the noise is required. This knowledge enhances the scope of the sound level meter and reduces the need for frequency analysis of industrial noise. Its application should be a helpful addition to the data provided by suppliers of hearing protectors.  相似文献   

13.
14.
Underwater and in-air noise evaluations were completed in performance pool systems at Georgia Aquarium under normal operating conditions and with performance sound tracks playing. Ambient sound pressure levels at in-pool locations, with corresponding vibration measures from life support system (LSS) pumps, were measured in operating configurations, from shut down to full operation. Results indicate noise levels in the low frequency ranges below 100?Hz were the highest produced by the LSS relative to species hearing thresholds. The LSS had an acoustic impact of about 10?dB at frequencies up to 700?Hz, with a 20?dB re 1?μPa impact above 1000?Hz.  相似文献   

15.
针对船用PN10DN32三通调节阀噪声声压频谱、声指向性等声学特性规律不明确,噪声声压级是否满足使用要求的问题,基于流-固耦合理论,同时考虑流-固耦合面及流体域内的脉动声学激励源,开展阀门噪声数值模拟研究。分别对三通调节阀在80%及60%开度阀外1 m处的噪声进行数值模拟,分析研究噪声声压频谱特性及声指向性规律。结果表明:80%及60%开度下的噪声声压级分别为49.14 dB(A)、50.79 dB(A),均小于60 d B(A)的噪声限制,满足使用要求。该文为船用三通调节阀噪声数值模拟提供了理论及方法参考。  相似文献   

16.
A new simple prediction model has been derived for the average A-weighted noise level due to many people speaking in a room with assumed diffuse sound field. Due to the feed-back influence of noise on the speech level (the Lombard effect), the speech level increases in noisy environments, and the suggested prediction model gives a 6 dB reduction of the noise level by doubling the equivalent absorption area of the room. This is in contrast to the lowering by 3 dB by doubling of the absorption area for a constant power sound source. The prediction model is verified by experimental data found in the literature. In order to achieve acceptable conditions for speech communication within a small group of people, a guide for the recommended minimum absorption area per person in eating establishments is provided.  相似文献   

17.
Sound pressure level measurements in cars travelling at motorway speeds have shown that, in many cases, the overall level is very high in relation to the dB(A) and octave band levels, suggesting that much of the sound energy is in the low frequency and infrasonic regions. A technique has been developed to extend accurate octave band measurements down to the octave centred on 2 Hz. The system uses a calibrated sound level meter feeding a frequency modulation tape-recorder to record noise below 64 Hz, and an octave band analysis system to analyse the resultant tape recordings. Typical results are presented for a number of vehicles and it is found that sound pressure levels as high as 120 dB can be found in the octave bands between 2 and 16 Hz.  相似文献   

18.
Using an audiometer,the effect of the noise level upon temporarythreshold shift(TTS)for five trained normal subjects(left ear only)was studied.The measurements were carried out after 6 min exposure(in third octave band)for different sound pressure levels ranging between 75-105 dB at three test fre-quencies 2,3,and 4 kHz.The results indicated that at exposure to noise of soundpressure level(SPL)above 85 dB,TTS increases linearly with ths SPL for all thetest frequencies.The work had extended to study the recovery curves for the sameears.The results indicated that the reduction in TTS on doubling the recoverytimes,for the two sound pressure levels 95 dB and 105 dB,occurs at a rate of near-ly 3 dB.The comparison of the recovery curve at 3 kHz with that calculated usingWard's general equation for recovery was made.Finally,to study the values ofTTS produced by exposure to certain noise at different test frequencies,distribu-tion curves for two recovery times were plotted representing TTS values,for anexposure  相似文献   

19.
The overall slope of long-term-average spectrum (LTAS) decreases if vocal loudness increases. Therefore, changes of vocal loudness also affects the alpha measure, defined as the ratio of spectrum intensity above and below 1000 Hz. The effect on alpha of loudness variation was analyzed in 15 male and 16 female voices reading a text at different degrees of vocal loudness. The mean range of equivalent sound level (L(eq)) amounted to about 28 dB and the mean range of alpha to 19.0 and 11.7 dB for the female and male subjects. The L(eq) vs. alpha relationship could be approximated with a quadratic function, or by a linear equation, if softest phonation was excluded. Using such equations alpha was computed for all values of L(eq) observed for each subject and compared with observed values. The maximum and the mean absolute errors were 2.4 dB and between 0.1 and 0.6 dB. When softest phonation was disregarded and linear equations were used, the maximum error was less than 2 dB and the mean absolute errors were between 0.2 and 0.7 dB. The strong correlation between L(eq) and alpha indicates that for a voice L(eq) can be used for predicting alpha.  相似文献   

20.
Pure-tone sound detection thresholds were obtained in water for one harbor seal (Phoca vitulina), two California sea lions (Zalophus californianus), and one northern elephant seal (Mirounga angustirostris) before and immediately following exposure to octave-band noise. Additional thresholds were obtained following a 24-h recovery period. Test frequencies ranged from 100 Hz to 2000 Hz and octave-band exposure levels were approximately 60-75 dB SL (sensation level at center frequency). Each subject was trained to dive into a noise field and remain stationed underwater during a noise-exposure period that lasted a total of 20-22 min. Following exposure, three of the subjects showed threshold shifts averaging 4.8 dB (Phoca), 4.9 dB (Zalophus), and 4.6 dB (Mirounga). Recovery to baseline threshold levels was observed in test sessions conducted within 24 h of noise exposure. Control sessions in which the subjects completed a simulated noise exposure produced shifts that were significantly smaller than those observed following noise exposure. These results indicate that noise of moderate intensity and duration is sufficient to induce TTS under water in these pinniped species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号