首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 323 毫秒
1.
Today, analyzing of sound pressure level and frequency is considered as an important index in human society. Sound experts believe that analyzing of these parameters can help us to better understanding of work environments. Sound measurements and frequency analysis did to fix the harmful frequency in all sections in Shiraz gas power plant with sound analyzer model BSWA 308. The sound pressure levels (LP) and the one and one-third octave band were continuously measured in A and C weighting networks and slow mode for time response. Excel 2013 and Minitab 18.1 software used for statistical calculations. Results analyzed by Minitab 18.1 software. The highest harmful frequency in Shiraz Gas Power Plant (SGPP) was 50 Hz with 115 dB. The sound pressure level (SPL) ranged from 45 dB to 120 dB in one-third octave band and weighting network C. The maximum sound pressure level was in Craft electricity generator with 105.3 dB and 67 Hz. Sound pressure level in surrounded environment was 120 dB. According to the results, in this industry the sound pressure level exceeded the Occupational Exposure Level of Iran (OEL). The value of sound pressure level were higher than the Standard of occupational health. SGPP consumes 47000 cubic meters of natural gas per hour to produce 100 MW (Mega Watt) of electricity. It is very high and it is not economical and cost effective. These numbers indicate that the power plant’s efficiency is low. It could be concluded that the noise pollution is an important issue in these industries. Moreover, SGPP produce noise with loss energy. Frequencies rotation at high sound pressure levels toward low frequencies were happened.  相似文献   

2.
Sound pressure level measurements in cars travelling at motorway speeds have shown that in many cases the overall level is very high in relation to the dB(A) and octave band levels, suggesting that much of the sound energy is in the low frequency and infrasonic regions. These levels have been measured down to the octave centred on 2 Hz. Experiments to investigate the effects of infrasound on balance and psychological awareness are described. The results show that levels of infrasound measured in moving vehicles can produce symptoms of balance disturbance, including vertical nystagmus, in normal observers, and also have profound effects on psychological awareness of normal human observers. Possible mechanisms for these effects are discussed.  相似文献   

3.
In order to further define in the literature the characteristics for different noise environments existing in industry over 2000 work stations in eleven different industries were investigated. The data measured included dB(A) sound levels and octave band sound pressure levels. These data are analyzed with respect to mean slope, mean slope as related to dB(A) sound level, flatness, bands of concentrated acoustic energy (or pure tones) and the correlation between the measured dB(A) sound level and that predicted by using the measured octave band sound pressure levels.  相似文献   

4.
The sound power of a number of test objects was determined from spatially averaged intensity measurements. The results show that the influence of room acoustics is insignificant even for rooms of widely different room constants, if the measuring surfaces are exactly defined and if a good space-averaging technique is used. The intensity integrated over a closed surface defining a source-free space compared to the sound pressure integrated over the same surface gives a measure of the capability of a specific intensity measuring system to suppress external noise. For the test arrangements measured with broad band noise, this suppression was found to be 14–18 dB(A). A similar value of 15 dB was found from sound power measurements on a source with high external sound and an analysis of the results in one-third octave bands. From these measurements an analytical function was derived which describes the average error of the spatially averaged intensity as a function of the difference between the external sound level and the source sound level. For practical measurement situations a further analytical function was derived which gives this intensity error as a function of the difference between the measured (spatially averaged) pressure and intensity levels. Thus it is possible to estimate the error of intensity measurements directly from measured intensity and pressure data.  相似文献   

5.
Using an audiometer,the effect of the noise level upon temporarythreshold shift(TTS)for five trained normal subjects(left ear only)was studied.The measurements were carried out after 6 min exposure(in third octave band)for different sound pressure levels ranging between 75-105 dB at three test fre-quencies 2,3,and 4 kHz.The results indicated that at exposure to noise of soundpressure level(SPL)above 85 dB,TTS increases linearly with ths SPL for all thetest frequencies.The work had extended to study the recovery curves for the sameears.The results indicated that the reduction in TTS on doubling the recoverytimes,for the two sound pressure levels 95 dB and 105 dB,occurs at a rate of near-ly 3 dB.The comparison of the recovery curve at 3 kHz with that calculated usingWard's general equation for recovery was made.Finally,to study the values ofTTS produced by exposure to certain noise at different test frequencies,distribu-tion curves for two recovery times were plotted representing TTS values,for anexposure  相似文献   

6.
A new method to reduce traffic noise by means of an ‘invisible’ wall has been investigated both theoretically and experimentally. A formula was derived for the frequency dependent impedance of an infinite structure of parallel ribs on an impedance boundary. From the definition of surface waves it followed that these waves can only exist for certain combinations of frequencies, heights of ribs and phases of the complex reflection coefficient of the underlying surface. Upon making this surface softer, more low frequency sound is absorbed. Outdoor experiments above an array of 16 or 21 low brick walls showed a considerable absorption of sound. Attenuations occurred up to 20 dB in the one-third octave bands from 125 to 400 Hz and amplifications up to 12 dB in the range of 400–1000 Hz. It was possible to explain these measurements qualitatively by the theory of surface waves. The wall structure caused an insertion loss of approximately 4 dB(A) in the total sound pressure level of the A-weighted one-third octave bands from 100 to 12,500 Hz.  相似文献   

7.
During the mid-1980s, calibrated measurements of ambient noise and wind speed were made in the Tongue of the Ocean in the Bahamas to quantify the spectra and statistics of wind-generated noise. This deep basin is topographically isolated from the Atlantic Ocean and, therefore, largely acoustically decoupled from the Atlantic Ocean deep sound channel. The quantitative effects of contaminating (non-surface wind-generated) noise sources within the basin were eliminated by careful measurement and robust statistical analysis methodologies. Above 500 Hz, the spectral slopes are approximately -5 dB per octave and independent of wind speed. Below 500 Hz, the ambient noise is no longer a linear function of wind speed. Below 100 Hz and for wind speeds greater than 18.5 knots (kt), the ambient noise is independent of frequency. The minimum observed ambient noise level falls 13 dB below Urick's "light shipping" level at 30 Hz and 2-5 dB below Wenz's sea state zero level through the wind-dominated portion of the spectrum. The basin's geographical isolation and the rigorous measurement and analysis methodologies employed make this two-decade-old data set a reasonable and justified proxy for pre-industrial era ocean noise levels in the 20 Hz to 20 kHz frequency band.  相似文献   

8.
The noise-excluding properties of a standard supra-aural audiometric earphone, a widely used circumaural-supra-aural combination, and an insert earphone sealed to the ear with a vinyl foam eartip were measured in a diffuse-field room complying with ANSI S12.6-1984. Data on attenuation were obtained monaurally with the nontest ear plugged and muffed. Results for the supra-aural earphones generally agreed well with previously reported measurements. A broadband masking noise was used to directly test the ANSI S3.1-1977 permissible background noise levels for measuring to audiometric zero using standard audiometric earphones. This "ANSI noise" raised the average thresholds of 15 normal-hearing test subjects by 3 to 5 dB at the octave frequencies from 500 to 4000 Hz. With a noise conforming to the less stringent OSHA-1983 regulation, average thresholds were elevated 9 to 17 dB. An "ENT office noise" with an overall sound level of 54 dBA raised average thresholds even further, by as much as 29 dB at 500 Hz. Use of the circumaural system in the office noise limited the threshold elevation to 11, 5, 2, and 0 dB at the four octave frequencies tested. With the fully ("deeply") inserted foam eartips, the threshold elevation in the simulated office noise was 2 dB or less at all test frequencies. Actual threshold elevations agreed closely with predictions based on a critical ratio calculation utilizing measured sound field noise levels and measured earphone attenuation values.  相似文献   

9.
Contours of equal loudness and threshold of hearing under binaural free-field conditions for the frequency range 20–15 000 Hz were standardized internationally in 1961. This paper describes an extension of the data in the low-frequency range down to 3·15 Hz, at l levels from threshold to 70 phon. The latter corresponds to nearly 140 dB sound pressure level at the lowest frequency. Direct loudness comparisons were made between tones at intervals of an octave, and the resulting contours were checked by numerical loudness estimation.  相似文献   

10.
11.
This paper describes a hybrid technique that combines Statistical Energy Analysis (SEA) predictions for structural vibration with acoustic modal summation techniques to predict interior noise levels in rotorcraft. The method was applied for predicting the sound field inside a mock-up of the interior panel system of the Sikorsky S-92 helicopter. The vibration amplitudes of the frame and panel systems were predicted using a detailed SEA model and these were used as inputs to the model of the interior acoustic space. The spatial distribution of the vibration field on individual panels, and their coupling to the acoustic space were modeled using stochastic techniques. Leakage and nonresonant transmission components were accounted for using space-averaged values obtained from a SEA model of the complete structural-acoustic system. Since the cabin geometry was quite simple, the modeling of the interior acoustic space was performed using a standard modal summation technique. Sound pressure levels predicted by this approach at specific microphone locations were compared with measured data. Agreement within 3 dB in one-third octave bands above 40 Hz was observed. A large discrepancy in the one-third octave band in which the first acoustic mode is resonant (31.5 Hz) was observed. Reasons for such a discrepancy are discussed in the paper. The developed technique provides a method for modeling helicopter cabin interior noise in the frequency mid-range where neither FEA nor SEA is individually effective or accurate.  相似文献   

12.
Previously it has been found through a series of psychoacoustical experiments that the arithmetic average of sound pressure level calculated in octave bands is a good estimator of loudness for various kinds of environmental noise. Remarkably, the arithmetic average of sound pressure level in octave bands from 63 Hz to 4 kHz, Lm,1/1(63-4k), strongly correlates with the loudness level specified in ISO 532B, LL(Z), as well as with loudness assessment. To investigate this relationship further, a numerical study has been carried out based on Zwicker’s loudness model. As a result, practical expressions to estimate the loudness levels of general environmental noises from the sound pressure levels in octave bands from 63 Hz or 125 Hz to 4 kHz are proposed.  相似文献   

13.
Bone conduction (BC) relative to air conduction (AC) sound field sensitivity is here defined as the perceived difference between a sound field transmitted to the ear by BC and by AC. Previous investigations of BC-AC sound field sensitivity have used different estimation methods and report estimates that vary by up to 20 dB at some frequencies. In this study, the BC-AC sound field sensitivity was investigated by hearing threshold shifts, ear canal sound pressure measurements, and skull bone vibrations measured with an accelerometer. The vibration measurement produced valid estimates at 400 Hz and below, the threshold shifts produced valid estimates at 500 Hz and above, while the ear canal sound pressure measurements were found erroneous for estimating the BC-AC sound field sensitivity. The BC-AC sound field sensitivity is proposed, by combining the present result with others, as frequency independent at 50 to 60 dB at frequencies up to 900 Hz. At higher frequencies, it is frequency dependent with minima of 40 to 50 dB at 2 and 8 kHz, and a maximum of 50 to 60 dB at 4 kHz. The BC-AC sound field sensitivity is the theoretical limit of maximum attenuation achievable with ordinary hearing protection devices.  相似文献   

14.
Maximum sound pressure levels are commonly used for environmental noise and building acoustics measurements. This paper investigates the signal processing errors due to Fast or Slow time-weighting detectors when combined with octave band filters, one-third octave band filters or an A-weighting filter. For 6th order Butterworth CPB filters the inherent time delay caused by the phase response of filters is quantified using three different approaches to establish the following rules-of-thumb: (1) time-to-gradient/amplitude matching occurs when Bt  1, (2) time-to-peak matching occurs when Bt  2 and (3) time-to-settle matching occurs when Bt  4 for octave band filters, and when Bt  3 for one-third octave band filters. Four different commercially-available sound level meters are used to quantify the variation in measured maximum levels using tone bursts, half-sine pulses, ramped noise and recorded transients. Tone bursts indicate that Slow time-weighting is inappropriate for maximum level measurements due to the large bias error. The results also show that there is more variation between sound level meters when considering Fast time-weighted maximum levels in octave bands or one-third octave bands than with A-weighted levels. To reduce the variation between measurements with different sound level meters, it is proposed that limits could be prescribed on the phase response for CPB filters and A-weighting filters.  相似文献   

15.
This article presents the results of a noise survey at Johns Hopkins Hospital in Baltimore, MD. Results include equivalent sound pressure levels (L(eq)) as a function of location, frequency, and time of day. At all locations and all times of day, the L(eq) indicate that a serious problem exists. No location is in compliance with current World Health Organization Guidelines, and a review of objective data indicates that this is true of hospitals throughout the world. Average equivalent sound levels are in the 50-60 dB(A) range for 1 min, 1/2, and 24 h averaging time periods. The spectra are generally flat over the 63-2000 Hz octave bands, with higher sound levels at lower frequencies, and a gradual roll off above 2000 Hz. Many units exhibit little if any reduction of sound levels in the nighttime. Data gathered at various hospitals over the last 45 years indicate a trend of increasing noise levels during daytime and nighttime hours. The implications of these results are significant for patients, visitors, and hospital staff.  相似文献   

16.
C. Hopkins  P. Turner 《Applied Acoustics》2005,66(12):1339-1382
Procedures for the field measurement of airborne sound insulation between rooms with diffuse fields are described in International Standard ISO 140-4. However, many dwellings contain rooms with volumes less than 50 m3, where low frequency measurements are less reliable; hence there is a need for a measurement procedure to improve the reliability of field measurements in rooms with non-diffuse fields. Procedures are proposed for sound pressure level and reverberation time measurements for the 50, 63 and 80 Hz third octave bands. The sound pressure level measurement combines corner microphone positions with positions in the central region of each room. This provides a good estimate of the room average sound pressure level with significantly improved repeatability.  相似文献   

17.
"Overshoot" is a simultaneous masking phenomenon: Thresholds for short high-frequency tone bursts presented shortly after the onset of a broadband masker are raised compared to thresholds in the presence of a continuous masker. Overshoot for 2-ms bursts of a 5000-Hz test tone is described for four subjects as a function of the spectral composition and level of the masker. First, it was verified that overshoot is largely independent of masker duration. Second, overshoot was determined for a variety of 10-ms masker bursts composed of differently filtered uniform masking noise with an overall level of 60 dB SPL: unfiltered, high-pass (cutoff at 3700 Hz), low-pass (cutoff at 5700 Hz), and third-octave-band-(centered at 5000 Hz) filtered uniform masking noises presented separately or combined with different bandpass maskers (5700-16000 Hz, 5700-9500 Hz, 8400-16000 Hz) were used. Third, masked thresholds were measured for maskers composed of an upper or lower octave band adjacent to the third-octave-band masker as a function of the level of the octave band. All maskers containing components above the critical band of the test tone led to overshoot; no additional overshoot was produced by masker components below it. Typical values of overshoot were on the order of 12 dB. Overshoot saturated when masker levels were above 60 dB SPL for the upper octave-band masker. The standard neurophysiological explanation of overshoot accounts only partially for these data. Details that must be accommodated by any full explanation of overshoot are discussed.  相似文献   

18.
A computer was programmed to model the distributions of dB(A) levels reaching the ears of an imaginary workforce wearing hearing protectors selected on the basis of either octave band attenuation values or various simplified ratings in use in Australia, Germany, Poland, Spain or the U.S.A. Both multi-valued and single-valued versions of dB(A) reduction and sound level conversion ratings were considered. Ratings were compared in terms of precision and protection rate and the comparisons were replicated for different samples of noise spectra (N = 400) and hearing protectors (N = 70) to establish the generality of the conclusions. Different countries adopt different approaches to the measurement of octave band attenuation values and the consequences of these differences were investigated. All rating systems have built-in correction factors to account for hearing protector performance variability and the merits of these were determined in the light of their ultimate effects on the distribution of dB(A) levels reaching wearers' ears. It was concluded that the optimum rating is one that enables the dB(A) level reaching wearers to be estimated by subtracting a single rating value from the dB(C) level of the noise environment, the rating value to be determined for a pink noise spectrum from mean minus one standard deviation octave band attenuation values with further protection rate adjustments being achieved by the use of a constant correction factor.  相似文献   

19.
This paper describes a semi-empiric model and measurements of air-borne sound generated by breaking sea waves. Measurements have been performed at the Baltic Sea. Shores with different slopes and sediment types have been investigated. Results showed that the sound pressure level increased from 60 dB at 0.4 m wave height to 78 dB at 2.0 m wave height. The 1/3 octave spectrum was dependent on the surf type. A scaling model based on the dissipated wave power and a surf similarity parameter is proposed and compared to measurements. The predictions show satisfactory agreement to the measurements.  相似文献   

20.
针对频率为500 Hz~3000 Hz和声压级为110 d B~133 d B的声场作用对铜球在空气中自然冷却的传热特性的影响,通过热电偶测温的方法,分析铜球温度梯度的分布与声场声压级、频率以及铜球直径的关系。结果表面,当频率f一定时,随着声压级的增加,铜球的传热效果得到明显增强,对于直径为5 mm的铜球,在133 d B声场中传热系数最大增加了25%。当声压级一定时,在频率范围中存在某一频率,此时铜球的传热系数最大,此特殊频率随着声压级的增大而增大。当铜球的直径为5 mm时,可以在低频段观测到声流效应的影响,而当铜球的直径为10 mm、15mm时,很难在低频段辨别出声流效应的影响。所得结论为声波应用于电站锅炉中,强化煤颗粒燃烧提供了依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号