排序方式: 共有15条查询结果,搜索用时 31 毫秒
1.
There are two cooling systems to maintain the thermal stability of the CSNS H^- ion source during its operation: Air-cooling in the source body of the discharging chamber and water-cooling in the flange on which the discharging chamber is installed. The optimal cooling parameters to ensure the operation of the H^- ion source are determined through a thermal analysis. In addition, a transient analysis is also performed to know exactly the transient temperature variation during the whole 40 ms period of the pulsed mode operation of the ion source. 相似文献
2.
3.
Study on the pre-chopper in CSNS LEBT 总被引:2,自引:0,他引:2
Physical designing of the pre-chopper in CSNS LEBT is carried out, which includes the deflecting voltage, the length and the width of the deflecting plates, and the gap between the deflecting plates. The most outstanding feature of the design is that both the gap and the width vary with the beam envelope size. So both the requried deflecting voltage and the loaded capacitance are lowered. In order to avoid destruction of the space charge neutralization by the pre-chopper in the whole LEBT, an electron-trapping electrode is arranged to confine the electrostatic field of the pre-chopper to the local area. To examine the reliability of the pre-chopping design in CSNS LEBT, a similar pre-chopping design in ADS RFQ LEBT is set up and an experiment on the pre-chopper is prepared. 3-dimensional simulations are carried out to determine the loaded capacitance and the applied voltage of the electron-trapping electrode. 相似文献
4.
The permanent magnets of the discharge chamber in a multi-cusp proton source are studied and designed. The three electrode extraction system is adopted and simulated. A method to extract different amounts of current while keeping the beam emittance unchanged is proposed. 相似文献
5.
There are two cooling systems to maintain the thermal stability of the CSNS H- ion source during its operation:Air-cooling in the source body of the discharging chamber and water-cooling in the flange on which the discharging chamber is installed.The optimal cooling parameters to ensure the operation of the H- ion source are determined through a thermal analysis.In addition,a transient analysis is also performed to know exactly the transient temperature variation during the whole 40 ms period of the pulsed ... 相似文献
6.
PP/EPDM共混物热氧稳定性研究 总被引:2,自引:0,他引:2
通过热氧加速老化的方法研究了不同的EPDM含量和抗氧剂对聚丙烯和三元乙丙橡胶共混物(PP/EPDM)热氧稳定性的影响.通过对老化前后试样的力学性能变化分析,热失重(TG)分析和扫描电镜(SEM)分析,结果表明:在热氧加速老化的初期,PP/EPDM共混物的拉伸强度随着时间的增长呈逐渐上升的趋势;在老化中期,共混物的拉伸强度变化不大;在老化后期,共混物的拉伸强度逐渐下降.在整个老化过程中,断裂伸长率都呈逐渐下降的趋势.而随着EPDM含量的增加,相应共混物的拉伸强度和断裂伸长率的下降减缓;相应共混物的分解温度得到较大的提高;抗氧剂的加入,能进一步提高共混物的热氧稳定性. 相似文献
7.
8.
9.
10.