1.
Accurate attenuation correction is required in dedicated breast PET imaging systems for image artifact removal and quantitative studies. In this study, a method using only emission data based on consistency conditions is proposed for attenuation correction in breast PET imaging systems. The consistency conditions are exploited to evaluate the accuracy of the estimated attenuation distribution and find the appropriate parameters that yield the most consistent attenuation distribution with the measured emission data. We have proved the validity of the method with experimental investigations and single-patient studies using a dedicated breast PET. The results show that the method is capable of accurately estimating the attenuation distribution of a uniform attenuator from the experimental data with various relatively low activities. The results also show that in single-patient studies, the method is robust for the irregular boundary of breast tissue and provides a distinct improvement in image quality.  相似文献   
2.
为了实现基于X射线断层成像(CT)的逆向工程中具有参数识别的三维图像重构, 提出了一种分割轮廓序列的新算法. 首先通过一定角度的射线法来得到轮廓间的嵌套关系,然后采用扫描一次关系矩阵生成轮廓树的方法实现层内轮廓定位, 最后运用轮廓间定量、定性的属性判定来完成层间的轮廓匹配. 通过实例, 本文提供的算法可以准确、快速地分割CT零件中的轮廓序列.  相似文献   
3.
简要介绍了基于飞行时间(Time of Flight, 简称TOF)技术的正电子发射断层扫描成像(Positron Emission Tomography, 简称PET)的基本原理, 回顾了TOF-PET成像设备的发展历史, 讨论了影响TOF PET时间分辨率的主要因素, 并对TOF-PET给图像重建技术带来的挑战进行了分析。 最后, 重点介绍了TOF-PET技术所带来的优势, 使用TOF技术可以有效地改善图像质量, 并且为临床诊断和临床前研究带来便利。 The principle of time of flight (TOF) positron emission tomography (PET) and a brief review of the history of TOF-PET are introduced. The factors influencing the time resolution of a TOF-PET scanner are presented, especially focus on the intrinsic properties of scintillators and front end electronics. Challenges and achievements of the structure of data organization and image reconstruction are reviewed. Finally, the benefits of TOF-PET on image quality improvement and tumor detection are emphasized.  相似文献   
4.
We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm × 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module.  相似文献   
5.
叶婷  柴培  高娟  贠明凯  刘双全  单保慈  魏龙 《中国物理 C》2011,35(12):1166-1171
In fully three-dimensional (3D) positron emission tomography (PET) imaging, the scatter fraction (SF) is about 40%-60%, which may degrade the imaging quality severely. Scatter correction is important for high quality image reconstruction. Model-based scatter correction has been proved to be accurate and available in clinical PET. However, it does not correct the scatter from out of the field of view (OFOV) and multiple scatters. In this study, we demonstrate the radial and axial distribution of scatters from OFOV when the source is located in different radial positions. In order to apply the above conclusions to different PET systems, we characterize the scatters from OFOV as a function of the ratio of the scanner diameter to the length of the axial field of view (AFOV) by modeling several typical whole-body and micro PET systems. The proportions of true events (S0-0), single scatter of one photon (S1-0) , single scatter of both photons (S1-1) , double scatter of one photon (S2-0) and multiple scatter (Sm) are also calculated and compared. Here the 3D-PET Monte Carlo simulations are performed with the Geant4 Application for Tomography Emission (GATE). In summary, the scatters from OFOV tend to be recorded on the lines of response (LOR) far away from the source. They have a much more serious impact on whole-body PET than micro PET depending on the ratio of scanner diameter to the length of AFOV. In whole-body PET, twice scatters including single scatter of both photons (S1-1) and double scatter of one photon (S2-0) add up to about 12% so that twice scatter correction must be taken into account to acquire a high quality reconstruction image.  相似文献   
6.
A fully 3D OSEM reconstruction method for positron emission tomography (PET) based on symmetries and sparse matrix technique is described. Great savings in both storage space and computation time were achieved by exploiting the symmetries of scanner and sparseness of the system matrix. More reduction of storage requirement was obtained by introducing the approximation of system matrix. Iteration-filter was performed to restrict image noise in reconstruction. Performances of simulation data and phantom data got from Micro-PET (Type: Epuls-166) demonstrated that similar image quality was achieved using the approximation of the system matrix.  相似文献   
7.
8.
自从多巴胺D3受体亚型克隆成功[1]以来,对D3受体功能的研究引起了极大的兴趣.它主要分布于哺乳动物大脑中与认知和情感功能相关的边缘脑区,特别是嗅结节、马列加氏岛和前脑基质的侧坐核隔膜,而且与抗精神病药物具有很高的亲和性,具有特殊的神经药理学意义[2].  相似文献   
9.
This article introduces the design and performance of the data acquisition system used in an omnidi- rectional gamma-ray positioning system, along with a new method used in this system to obtain the position of radiation sources in a large field. This data acquisition system has various built-in interfaces collecting, in real time, information from the radiation detector, the video camera and the GPS positioning module. Experiments show that the data acquisition system is capable of carrying out the proposed quantitative analysis to derive the position of radioactive sources, which also satisfies the requirements of high stability and reliability.  相似文献   
10.