首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  免费   0篇
  国内免费   4篇
物理学   4篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Micromegas prototypes with thermo-bond film separators   总被引:1,自引:0,他引:1  
In this paper we report the results of Micromegas prototypes constructed by attaching micromesh to an anode using thermo-bond films. The excellent metal attaching ability and good dielectical property of this kind of film make it a promising material to be used as avalanche gap spacers. Several prototypes are successfully made. The electron transmission properties are first studied and then the gas gain is measured in argon-isobutane mixtures. The maximum gain of more than 104 is easily obtained. The energy resolutions for 55Fe 5.9 keV Kα ray can be better than 20% over one magnitude in gain for different operational gas mixtures and the best energy resolution of 13.7% (FWHM) can be achieved with the gas mixture of 94% argon concentration. The preliminary test results of the prototypes with sensitive area of 45 mm×45 mm without internal support show good uniformity across the sensitive area.  相似文献   
2.
The structure and working principle of Micromegas (MICRO Mesh Gaseous Structure) is discussed. Some radiation sources of α and X rays are used to test this detector. The optimized electric-field intensity of the conversion gap is obtained. The transmission of electrons and the uniformity of the amplification gap are also presented. The energy resolution of the 5.9 keV peak is better than 27%.  相似文献   
3.
We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm × 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module.  相似文献   
4.
Micromegas (MICRO MEsh GAseous Structure) is a position-sensitive gaseous detector. It is widely used in particle physics. We present the results of full 3D Monte Carlo simulations of Micromegas performance, taking into account all the processes from the primary ionization, the elctron collection efficiency, and the gain to the signal formation. The simulation results are in good agreement with experimental data.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号