排序方式: 共有58条查询结果,搜索用时 31 毫秒
1.
High throughput N-modular redundancy for error correction design of memristive stateful logic 下载免费PDF全文
Memristive stateful logic is one of the most promising candidates to implement an in-memory computing system that computes within the storage unit. It can eliminate the costs for the data movement in the traditional von Neumann system. However, the instability in the memristors is inevitable due to the limitation of the current fabrication technology, which incurs a great challenge for the reliability of the memristive stateful logic. In this paper, the implication of device instability on the reliability of the logic event is simulated. The mathematical relationship between logic reliability and redundancy has been deduced. By combining the mathematical relationship with the vector-matrix multiplication in a memristive crossbar array, the logic error correction scheme with high throughput has been proposed. Moreover, a universal design paradigm has been put forward for complex logic. And the circuit schematic and the flow of the scheme have been raised. Finally, a 1-bit full adder (FA) based on the NOR logic and NOT logic is simulated and the mathematical evaluation is performed. It demonstrates the scheme can improve the reliability of the logic significantly. And compared with other four error corrections, the scheme which can be suitable for all kinds of R-R logics and V-R logics has the best universality and throughput. Compared with the other two approaches which also need additional complementary metal-oxide semiconductor (CMOS) circuits, it needs fewer transistors and cycles for the error correction. 相似文献
2.
A new complex K0.5[K(18-crown-6)]1.5Ge9·1.5en(1) which contains unprecedented "up" and "down" chain arrangement of unit [-(Ge-9-K-Ge9)3-] has been prepared by the reaction of K4Ge9 with HgS in ethylenediamine(en) in the presence of 18-crown-6(1,4,7,10,13,16-hexaoxacyclooctadecane), and characterized by X-ray structure analysis. The color of the title crystals(black), which is darker than that of the reported three compounds with chains of germanium clusters, may result from the naked K+ and their interactions with the chain. And the structure differences between 1 and the reported three compounds with chains of germanium have also been discussed. 相似文献
3.
4.
A new mixed-valence heterometal cluster Mo8VW2VIO26(C5H5N)8·2H2O has been synthesized under solvothermal conditions and characterized by X-ray single-crystal diffraction, IR, UV-vis and XPS spectroscopy. The title compound crystallizes in the triclinic system, space group P1 with a = 11.708(3), b = 12.018(4), c = 13.316(4) , a = 112.184(4), β = 97.844(4), r = 110.043(3)o, V = 1551.9(8) 3 and Z = 1 at 293(2) K. The final full-matrix least-squares refinement converged to R = 0.0414 for 4460 observed unique reflections with I 2σ(I) and w R = 0.1290 for all data(5352) and S = 1.015. In addition, its thermal stability and fluorescent property have also been investigated. 相似文献
5.
6.
用无火焰原子吸收光谱测定家兔从肝动脉注射顺氯氨铂前后的血药浓度及在体内分布情况。 相似文献
7.
采用有限元方法研究了球形弹丸对铝和碳酚醛平板靶冲击,给出了动态响应的理论计算和图形分析结果。 相似文献
8.
The variation in environmental scattering background is a major source of systematic errors in X- ray inspection and measurement systems. As the energy of these photons consisting of environmental scattering background is much lower generally, the Cerenkov detectors having the detection threshold are likely insensitive to them and able to exclude their influence. A thickness measurement experiment is designed to verify the idea by employing a Cerenkov detector and an ionizing chamber for comparison. Furthermore, it is also found that the application of the Cerenkov detectors is helpful to exclude another systematic error from the variation of low energy components in the spectrum incident on the detector volume. 相似文献
9.
Multi-gap Resistive Plate Chamber (MRPC) is a new generation of gas detector with good timing and spacial resolution, whose technique is widely applied in some recent high energy (nuclear) physics experiments. In this letter, we report a long-strip two-end readout MRPC and its test beam performance. The measurements show that the long-strip performs a transmission line characteristic and the impedance is independent of the length of strip. The MRPC module we developed is presented to gain a timing resolution of -80 ps and a spacial resolution of -6.4 mm. The possible application of the MRPC is also discussed. 相似文献
10.
Six-gap resistive plate chamber (MRPC) prototypes with semiconductive glass electrodes (bulk resistivity ~ 10^10Ω·cm) were studied for suitability in time-of-flight (TOF) applications at high rates. These studies were performed using a continuous electron beam of 800 MeV at IHEP and an X-ray machine. Time resolutions of about 100 ps and efficiencies larger than 90% were obtained for flux densities up to 28 kHz/cm^2. 相似文献