排序方式: 共有8条查询结果,搜索用时 0 毫秒
1
1.
A pilot experiment for mass measurement at CSRe 总被引:2,自引:1,他引:1
A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u ^36Ar delivered by CSRm were injected into CSRe. The revolution periods of the stored ions,which depend on the mass-to-charge ratios of the stored ions,were measured with a time-of-flight detector system. The results show that the mass resolution around 8×10^-6 for △m/m is achieved. 相似文献
2.
范凤英 郑涛 叶沿林 江栋兴 华辉 李智焕 葛愉成 李湘庆 楼建玲 史帆 吕林辉 曹中鑫 聂鹏煊 李奇特 宋玉收 卢飞 徐瑚珊 胡正国 王猛 张雪荧 李琛 陈若富 唐彬 徐治国 岳珂 张亚鹏 臧永东 章学恒 姚向武 陈金达 涂小林 张洁 武大鹏 白真 《中国物理快报》2009,26(8):74-77
Differential cross sections for the quasi-elastic scattering of^16 C at 47.5 MeV/nucleon from ^12 C target are measured.Coupled-channels calculations are carried out and the optical potential parameters are obtained by fitting the experimental angular distribution. 相似文献
3.
臧永东 武军霞 赵铁成 张生虎 毛瑞士 徐瑚珊 孙志宇 马新文 涂小林 肖国青 F. Nolden P. Hülsmann Yu. A. Litvinov C. Peschke P. Petri M. S. Sanjari M. Steck 《中国物理 C》2011,35(12):1124-1129
A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 1072 and the shunt impedance is 76 kΩ. The measured results of the characteristics are in agreement with the MAFIA simulations. 相似文献
4.
吕林辉 叶沿林 江栋兴 华辉 郑涛 李智焕 葛愉成 李湘庆 楼建玲 曹中鑫 宋玉收 肖军 李奇特 乔锐 游海波 陈瑞久 徐瑚珊 王建松 郭忠言 张雪荧 李琛 胡正国 陈若富 王猛 徐治国 岳珂 唐彬 臧永东 章学恒 姚向武 陈金达 白真 《中国物理 C》2011,35(10):891-895
A knockout reaction induced by 6He at 61.2 MeV/u was carried out at the HIRFL-RIBLL radioactive beam line. The α core fragments at forward angles were detected in coincidence with the recoiled protons at large angles. From this coincident measurement the valence nucleon knockout mechanism and the core knockout mechanism can be separated according to the polar angle correlation between the core fragments and the recoiled protons. It is demonstrated that, when reconstructing the resonant state of a weakly bound nucleus, the contamination resulting from the core knockout mechanism should be eliminated in order to obtain the correct structure information. 相似文献
5.
6.
Secondary electron time detector for mass measurements at CSRe 总被引:1,自引:0,他引:1
The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deflected 180°by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10^-6 for Am/m was achieved by using this time detector in a pilot mass measurement experiment. 相似文献
7.
胡钧 何建军 # 许世伟 陈志强 张雪荧 王建松 于祥庆 苏俊 李二涛 王宏伟 田文栋 李龙 张立勇 杨彦云 马朋 章学恒 胡正国 郭忠言 徐星 袁小华 鲁皖 余玉洪 臧永东 唐述文 叶瑞平 陈金达 金仕纶 杜成名 王世陶 马军兵 刘龙祥 白真 雷祥国 孙志宇 李湘庆 张玉虎 周小红 徐瑚珊 《原子核物理评论》2011,28(4):428-432
实验通过17F+p共振弹性散射研究了复合核18Ne激发态中与天体核反应14O(α, p)17F相关的共振态性质。利用兰州放射性束流线(RIBLL)对弹核碎裂反应产生的放射性束17F进行了分离和提纯。经过降能后,能量为4.22 AMeV 的17F束流轰击在T2终端的厚氢靶(CH2)n上。 两套∆E-E Si探测器望远镜放置在两个不同的探测角度θlab≈2.3°和14°上,对反冲质子的角度和能量进行了测量。实验观测到了复合核18Ne的几条质子共振能级。通过R-Matrix理论程序对激发函数进行拟合,得到了共振态的能量、 自旋、 宇称和衰变宽度等共振参数。Resonant properties in18Ne relevant to the stellar reaction of 14O(α, p)17F have been investigated through a resonant elastic scattering of 17F+p. The 17F RI beam was produced via a projectile fragmentation reaction, and subsequently separated and purified by Radioactive Ion beam Line in Lanzhou(RIBLL). After a series of energy degradation,a 4.22 AMeV 17F beam bombarded a thick(CH2)ntarget at T2 terminal. Energy and angle of the recoiled protons were measured by two sets of ∆E-E silicon telescope at θlab≈2.3°,14° respectively. Several resonances in 18Ne were observed,and their resonant parametersincluding energy,spin parity and decay width have been determined by an R-Matrix analysis of the experimental excitation function. 相似文献
8.
A prototype of time-of-flight positron emission computed tomography (TOF-PET) has been developed for acquiring the coincident detection of 511 keV γ-rays produced from positron annihilation. It consists of two 80.5 mm×80.5 mm LYSO scintillator arrays (composed of 35×35 pixel finger crystals) with the position sensitive photomultiplier tubes R2487 as the readout. Each array is composed of 2 mm×2 mm×15 mm finger crystals and the average pixel pitch is 2.30 mm. The measured results indicate that the TOF information has the potential to significantly enhance the image quality by improving the noise variance in the image reconstruction. The best spatial resolution (FWHM) of the prototype for the pairs of 511 keV γ-rays is 1.98 mm and 2.16 mm in the x and y directions, respectively, which are smaller than the average pixel pitch of 2.30 mm. 相似文献
1