排序方式: 共有27条查询结果,搜索用时 15 毫秒
1.
We extend our previous analysis of the toy model that mimics the mode coupling theory of supercooled liquids and glass transitions to the out of equilibrium dynamics. We derive a self-consistent set of equations for correlation and response functions. 相似文献
2.
采用端视电感耦合等离子体原子发射光谱(ICP-AES)法同时测定玩具涂料中可溶性铅、镉、汞、砷、铬、锑、硒和钡.对仪器的工作参数和被测元素的分析谱线进行了优化和选择.铅、镉、汞、砷、铬、锑、硒和钡的检出限分别为0.006、0.0009、0.012、0.023、0.000 8、0.013、0.030和0.0006 mg/L.定量下限分别为0.99、0.15、2.0、3.8、0.14、2.2、5.0和0.10 mg/kg.相对标准偏差为0.76%~2.72%(n=8),加标回收率为96.0%~104.0%.该法适用于玩具涂料中铅、镉、汞、砷、铬、锑、硒和钡的快速测定. 相似文献
3.
4.
采用在线富集/高效液相色谱(HPLC)与电感耦合等离子体质谱(ICP-MS)联用技术,建立了玩具中超痕量可迁移六价铬的测定方法。以10 mmol/L硝酸铵为流动相,样品在Agilent BIO WAX NP5阴离子交换柱(4.6 mm×50 mm,5μm)中富集,再通过阀切换,以75 mmol/L硝酸铵将六价铬洗脱至Dionex AG7阴离子柱(4.0 mm×50 mm,10μm)中分离,最后经ICP-MS进行分析。优化得到在线富集时间为4 min,进样量为900μL,富集流速为0.4 mL/min,洗脱流速为0.6 mL/min。结果显示,六价铬在2~20 ng/L范围内线性良好,检出限为1.93 ng/L,相对标准偏差(RSD)为3.9%。与直接进样相比,浓缩因子约为8.1倍,富集效率约为90%。对欧盟玩具安全指令2009/48/EC规定的3类玩具材料在5、10 ng/L的浓度水平下进行加标回收,回收率为93.4%~111%。 相似文献
5.
We present interactive quantum chemistry simulation at the atom superposition and electron delocalization molecular orbital (ASED-MO) level of theory. Our method is based on the divide-and-conquer (D&C) approach, which we show is accurate and efficient for this non-self-consistent semiempirical theory. The method has a linear complexity in the number of atoms, scales well with the number of cores, and has a small prefactor. The time cost is completely controllable, as all steps are performed with direct algorithms, i.e., no iterative schemes are used. We discuss the errors induced by the D&C approach, first empirically on a few examples, and then via a theoretical study of two toy models that can be analytically solved for any number of atoms. Thanks to the precision and speed of the D&C approach, we are able to demonstrate interactive quantum chemistry simulations for systems up to a few hundred atoms on a current multicore desktop computer. When drawing and editing molecular systems, interactive simulations provide immediate, intuitive feedback on chemical structures. As the number of cores on personal computers increases, and larger and larger systems can be dealt with, we believe such interactive simulations-even at lower levels of theory-should thus prove most useful to effectively understand, design and prototype molecules, devices and materials. 相似文献
6.
7.
8.
高效液相色谱-电感耦合等离子体质谱联用测定儿童玩具中痕量铬(Ⅲ)与铬(Ⅵ) 总被引:1,自引:0,他引:1
建立了高效液相色谱-电感耦合等离子体质谱联用技术(HPLC-ICP-MS)测定玩具中痕量三价铬和六价铬的分析方法。考察了不同p H值、不同流动相、流速、质谱条件等影响因素对实验体系的影响,优化了HPLC-ICP-MS方法,使得三价铬和六价铬的检出限分别达到0.024 mg/kg和0.015 mg/kg,满足EN71-3第一类和第三类检出限的要求。将方法应用于玩具样品中三价铬和六价铬的分析,加标回收率为85.4%~119%,相对标准偏差为3.0%~5.0%。该方法简单、灵敏、准确,可用于塑料、毛绒面料、纸类玩具等玩具样品的测定。 相似文献
9.
该文以欧盟新玩具指令中限用或禁用的15种致敏芳香化合物为研究目标,研究了超临界二氧化碳萃取压力、温度、夹带剂等条件对萃取效率的影响,建立了超临界流体萃取/气相色谱-质谱联用仪测定玩具中15种致敏芳香化合物的分析方法。最佳萃取条件为:萃取温度50 ℃,压力300 bar,二氧化碳流速30 g/min,夹带剂甲醇含量3%,动态萃取30 min,静态萃取30 min。萃取物经DB-17MS色谱柱分离后,采用质谱仪进行检测,内标法定量。15种化合物在0.02~60 μg/mL范围呈良好线性,相关系数为0.993 2~0.999 9,检出限(S/N=10) 为0.02~0.09 μg/mL。该法检测聚丙烯(PP)、聚乙烯(PE)、丙烯腈-丁二烯-苯乙烯(ABS)塑料的回收率分别为79.6%~114.5%、75.0%~118.9%、72.7%~114.9%,相对标准偏差为3.2%~11.0%、0.6%~11.6%、3.5%~11.0%。建立的方法灵敏、环保,可用于玩具中致敏芳香化合物的检测。 相似文献
10.
选择塑料、纺织品和油漆涂层三类常见玩具材料,采用模拟胃液、酸性汗液、碱性汗液和唾液浸泡提取样品,使用ICP-AES法测试提取液中17种欧盟玩具新指令限制元素(铝、锑、砷、钡、硼、镉、铬、钴、铜、铅、锰、汞、镍、硒、锶、锡、锌)迁移量,试验了前处理过程中不同振荡频率对金属元素迁移量的影响。试验结果表明:胃液对金属元素溶出能力最大,汗液溶出能力最弱,样品提取过程中,恒温水浴振荡器振荡频率在80-160U/min范围内时,特定元素溶出量基本不受振荡频率的影响。 相似文献