排序方式: 共有30条查询结果,搜索用时 15 毫秒
21.
22.
A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mm×200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector. 相似文献
23.
To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the CEM pream- plification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas. 相似文献
24.
为研发能够满足北京同步辐射(BSRF)实验要求的二维探测器,研制了基于读出条读出的二维位置灵敏X射线气体电子倍增器(GEM).实验过程中通过改进读出条的周期,并基于中科院高能所实验物理中心电子学组研制的多路电荷放大器系统与VME存储-ADC系统,对软X射线源的位置分辨率进行了精密测量且得到了优异的二维位置分辨:X方向约为84μm,Y方向约为75μm.研究了三级GEM压差之和对位置分辨的影响,并测试了探测器的位置准确度与线性.对基于阳极读出的GEM用于模拟读出测试系统得到了一定的理论认识,侧重研究了GEM探测器基于模拟读出的系统特性,给出了相关的分析与讨论. 相似文献
25.
26.
27.
小单元漂移室用放射源模拟老化的实验研究 总被引:2,自引:0,他引:2
BESⅢ 漂移室(DC)模型用1.85X109 Bq 55Fe 5.9keV X射线放射源作加速老化实验研究.测量了阳极丝电流I和55Fe 5.9keV X射线全能光电峰位随累积电荷量Q的变化,由此得到累积相当BESⅢ DC 5年全天候运行的电荷量(0.07 C/cm)后,漂移室小单元的阳极电流降为初始值的87%;老化率为R=-0.19%/(mC/cm) 相似文献
28.
29.
30.
A method to determine precisely three-dimensional wire positions in the BESⅢ drift chamber using physics events is introduced. In part the proposed technique takes advantage of the possibility that the magnetic field can be turned off, thereby providing a huge sample of straight tracks for which effects due to multiple scattering, energy loss and non-uniformity of the magnetic field are minimized during the calibration process. A toy Monte Carlo study is performed to demonstrate the viability of the method. As a result of the calibration process, the rms of the distribution of wire position deviation is reduced from 35μm to 10μm. 相似文献