首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
建立了微波辅助萃取–气相色谱法测定茶叶中甲胺磷、乐果、毒死蜱、水胺硫磷、三唑磷5种有机磷农药残留量的分析方法。样品用乙酸乙酯微波辅助提取,提取液经分散固相萃取法(DSPE)净化,用气相色谱配FPD检测器测定,外标法定量。结果表明农药混合标准溶液在0.01~0.5μg/mL范围内线性良好(r>0.999),方法的检出限为0.005~0.01 mg/L,在0.05,0.125,0.5μg/mL 3个水平添加平均回收率为63.3%~99.9%,测定结果的相对标准偏差为5.1%~8.2%(n=6)。该方法适合于茶叶中多种有机磷农药残留量的同时检测。  相似文献   

2.
建立了气相色谱-质谱快速测定水产品中禾草丹、溴氰菊酯及19种有机氯农药残留的方法.样品经乙腈提取后采用冷冻法去除提取溶液中的大量脂肪,再经氨基固相萃取柱进一步净化后用GC-MS测定.21种农药在0.1~2.0 mg/L范围内线性良好,相关系数r>0.999,样品添加量为0.02~0.1 mg/kg时回收率为79%~114%,相对标准偏差不大于13.5%,检出限为0.5~20 μg/kg(S/N=3).  相似文献   

3.
建立了同时测定食用菌中19种氨基甲酸酯类农药(NMCs)残留的超高效液相色谱-串联质谱法(UPLC-MS/MS)。通过丙酮和乙腈(85∶15,V/V)提取,GPC法和PSA固相萃取柱两种方法净化,UPLC-MS/MS同时测定蘑菇、香菇、木耳和牛肝菌中19种氨基甲酸酯类农药,同位素稀释法定量。以GPC法净化,回收率为74.0%~93.2%;以PSA固相萃取柱净化,回收率为70.2%~91.8%,两种方法的检出限均为0.01mg/kg。各种NMCs在确定的添加范围内线性关系良好,线性相关系数R均大于0.99。所建立的检测方法实用、准确、灵敏度高。  相似文献   

4.
建立了在线净化-液相色谱-串联质谱测定茶叶中吡虫啉、啶虫脒、噻虫啉、噻虫嗪和噻虫胺5种常见烟碱类农药残留量的方法。样品经水浸泡、乙腈提取和在线净化后,用液相色谱-串联质谱测定。结果表明,本方法对5种烟碱类农药的定量限均为0.01 mg/kg。5种烟碱类农药在1.0~10 μ g/L范围内具有良好的线性关系,相关系数均大于0.998。在0.01、0.02和0.05 mg/kg的添加水平下,回收率为68.0%~113.2%,相对标准偏差为3.2%~7.6%。本方法简便、快速、准确,适用于茶叶样品中烟碱类农药残留量的检测。  相似文献   

5.
建立了QuEChERS-气相色谱/三重四极杆串联质谱(GC-MS/MS)测定杨桃中37种农药残留量的方法.样品以1%乙酸乙腈为提取溶剂,采用QuEChERS净化,在质谱多反应监测(MRM)模式下进行定性,基质匹配标准曲线外标法定量.结果表明:在0.01~0.5 mg/L范围内,37种农药的线性关系良好,方法定量限均低于0.01 mg/kg;在低、中、高3个添加水平范围内平均回收率在72.9%~117%之间,相对标准偏差(RSD)≤9.6%.该方法简单、快速、溶剂用量少、灵敏度高,适用于分析杨桃样品中37种农药残留量的检测和确证.  相似文献   

6.
建立了以QuEChERS作为前处理方法,气相色谱/质谱联用法同时测定茶叶中33种农药残留的检测方法。样品经改进的QuEChERS法进行提取净化,采用DB-5MS(30m×0.25mm×0.25μm)毛细管色谱柱分离,选择离子模式下同时测定,外标法定量。33种农药残留在0.01~3.00mg/L范围内线性关系良好,相关系数均大于0.999。方法的检出限为4.0~35μg/kg,样品平均添加回收率为82.7%~103.8%,相对标准偏差为0.73%~6.8%。方法适用于茶叶中毒死蜱、联苯菊酯等33种不同类型农药残留的同时检测。  相似文献   

7.
建立固相萃取净化–气相色谱–串联质谱法同时测定茶叶中9种农药残留量的方法。茶叶样品用乙腈均质提取,提取液经固相萃取净化处理后,采用DB–5MS毛细管色谱柱分离,在多反应监测模式下测定,外标法定量。9种农药组分的质量浓度在0.01~0.50 mg/L范围内与其色谱峰面积呈良好线性,相关系数r~2大于0.998,方法测定下限(10 S/N)为0.002~0.01 mg/kg。以空白绿茶、红茶、普洱茶和乌龙茶为基体,在0.05,0.1,0.2 mg/kg 3个添加水平进行加标回收试验,加标回收率在73.6%~99.7%之间,相对标准偏差为4.2%~8.7%(n=6)。该法操作简便、快速,适用于茶叶中多种农药残留的测定。  相似文献   

8.
建立了气相色谱-串联质谱(GC-MS/MS)同时测定三七中212种农药残留的方法。样品以乙腈-乙酸乙酯(体积比1∶3)提取,经FaPEx-BKT50固相萃取柱净化,待测物采用GC-MS/MS测定,以保留时间和特征离子对定性,外标法定量。结果表明,212种农药在10~200μg/L范围内线性关系良好,相关系数(r2)均大于0.999,检出限(S/N=3)为0.003~0.02 mg/kg,定量下限(S/N=10)为0.01~0.05 mg/kg。在空白样品中进行0.02、0.04、0.1 mg/kg 3个水平的加标回收实验,212种农药的平均回收率为60.0%~121%,相对标准偏差(RSD)为0.90%~31%。该方法简单、灵敏、稳定,可有效去除复杂基体的干扰,各项技术指标均满足国内外农药残留的限量要求,适用于中药材三七中痕量农药的残留测定。  相似文献   

9.
建立了一种测定水环境中16种农药残留的反相高效液相色谱法。样品直接过C18固相萃取小柱富集浓缩,甲醇洗脱,采用高效液相色谱紫外检测器检测,外标法定量。16种农药质量浓度在0.25~10mg/L范围内呈线性关系,相关系数为0.9990~0.9999。在质量浓度0.05~0.3mg/L范围内,平均加标回收率在70.7%~112.2%之间,相对标准偏差为1.6%~12%。方法的检出限0.01~0.23mg/L。  相似文献   

10.
建立了高效液相色谱法同时测定大米样品中呋虫胺、噻虫胺、吡虫啉、吡虫清4种烟碱农药残留量的检测方法,对4种烟碱农药在ENVI-Florisil和Carb复合固相萃取柱上的保留行为进行了研究。样品用乙腈提取,固相萃取净化,HPLC-DAD分离检测,外标法定量。峰面积与标准溶液浓度在0.1~1.0 mg/L范围内呈良好的线性关系,相关系数大于0.9996。样品加标回收率为75.5%~96.0%,相对标准偏差为0.49%~4.36%(n=6),检出限达到0.004 mg/kg。  相似文献   

11.
搅拌棒吸附子萃取与GC-MS法测定水中20种有机氯农药   总被引:2,自引:0,他引:2  
建立了搅拌棒吸附子萃取/气相色谱-质谱法(SBSE/GC-MS)同时检测水中α-六六六、γ-六六六、β-六六六、七氯、δ-六六六、艾氏剂、环氧七氯、γ-氯丹、顺-氯丹、硫丹Ⅰ、p,p-滴滴伊、狄氏剂、异狄氏剂、p,p-滴滴滴、硫丹Ⅱ、p,p-滴滴涕、异狄氏剂醛、硫丹硫酸盐、甲氧滴滴涕、异狄氏剂酮20种有机氯农药含量的方法.样品在室温下经拌棒吸附子搅拌吸附,甲醇解吸附后,以J&W DB-35 MS(30 m×0.25 mm×0.25 μm)石英毛细管色谱柱为分析柱,气相色谱-质谱选择离子流模式检测.考察了萃取时间、氯化钠及甲醇加入量等对萃取的影响.实验结果表明:在2.5 ~20.0 μg/L 范围内,20种有机氯农药呈良好的线性关系,检出限(S/N=3)为0.008 ~0.118 μg/L,水样中分别添加2.5、20 μg/L的20种有机氯农药,回收率为 52% ~117%,相对标准偏差小于13%(n= 6).该方法操作简便、快速、灵敏度高,应用于实际样品检测,结果满意.  相似文献   

12.
建立了枇杷花中有机氯类农药残留量的固相萃取-毛细管气相色谱(SPE-CGC)分析方法。对采自福建蒲田等12地的枇杷花中六六六(4种异构体)、滴滴涕(4种异构体)、五氯硝基苯共9种有机氯农药的残留量进行了测定。样品采用丙酮超声波提取,浓缩后过Florisil固相萃取小柱净化,洗脱剂为V(正己烷)∶V(丙酮)100∶1。用DB-1701弹性石英毛细管气相色谱柱分离样品,微电子捕获检测器进行检测。9种有机氯农药的峰面积与其质量浓度均有良好的线性关系,相关系数均大于0.999,最低检测限为0.016~0.125μg/L,样品的加标回收率为85.4%~106.9%,相对标准偏差为1.8%~9.8%。该方法能够满足农药残留检测的要求。  相似文献   

13.
加压溶剂萃取-气相色谱法测定荞麦中残留的有机氯农药   总被引:2,自引:1,他引:1  
廉玫  许峰  观文娜  徐媛  关亚风 《色谱》2008,26(4):484-488
用所研制的24位全自动加压溶剂萃取仪(APLE),以丙酮-正己烷(体积比为1∶1)为溶剂,在100 ℃和10 MPa条件下,对荞麦样品中残留的7种有机氯农药进行了萃取,并通过气相色谱对萃取液进行定量分析。萃取的绝对回收率为68%~126%,相对标准偏差为1.2% ~14.7%,检测下限为0.051~0.18 ng/g。与索氏提取法对比,相对提取回收率为116%~148%,表明萃取收率高于索氏提取法。  相似文献   

14.
A coupled technique, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), was investigated for one-step in situ sample pretreatment for organochlorine pesticides (OCPs) prior to gas chromatographic determination. The OCPs, aldrin, o,p'-DDE, p,p'-DDE, o,p'-DDT, p,p'-DDT, dieldrin, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, endrin, delta-HCH, gamma-HCH, heptachlor, heptachlor epoxide, methoxychlor and trifluralin were collected by the proposed method and analyzed by gas chromatography with electron-capture detection (GC-ECD). To perform the MA-HS-SPME, six types of SPME fibers were examined and compared. The parameters affecting the efficiency in MA-HS-SPME process such as sampling time and temperature, microwave irradiation power, desorption temperature and time were studied to obtain the optimal conditions. The method was developed using spiked water samples such as field water and with 0.05% humic acid in a concentration range of 0.05-2.5 microg/l except endosulfan sulfate in 0.25-2.5 microg/l. The detection was linear over the studied concentration range with r2>0.9978. The detection limits varied from 0.002 to 0.070 microg/l based on S/N=3 and the relative standard deviations for repeatability were <15%. A certified reference sample of OCPs in aqueous solution was analyzed by the proposed method and compared with the conventional liquid-liquid extraction procedure. These results are in good agreement. The results indicate that the proposed method provides a very simple, fast, and solvent-free procedure to achieve sample pretreatment prior to the trace-level screening determination of organochloride pesticides by gas chromatography.  相似文献   

15.
Abstract

A semi-preparative (25 cm × 9.4 mm i.d.) HPLC ODS-bonded silica column was evaluated for the fractionation of pesticides from edible fats and oils of both animal and vegetable origin. Using acetonitrile as a mobile phase, organochlorine and organophosphorous pesticides with a wide range of polarity were eluted in the first 40 ml of eluate. Co-eluted lipid material ranged from 0 to 35 mg for 500 mg injections, depending on sample type. Excessively “dirty” samples (e.g., tallow) were further cleaned up on small Florisil columns. Recoveries of selected pesticides from fortified samples, which were determined by gas chromatography with electron capture and flame photometric detectors, ranged from 80 to 108%.  相似文献   

16.
An electron-capture detector (ECD) was used in packed column supercritical fluid chromatography (SFC) for the selective determination of chlorinated pesticides. The separation of chlorinated pesticides was conducted on an ODS-silica gel column using carbon dioxide as a mobile phase without a modifier. The detection temperature of ECD was set to 325°C according to the peak sensitivities. The SFC/ECD system was applied to the determination of γ-BHC and p, p′-DDD in carrots extracted by supercritical fluid extraction. The recoveries of γ-BHC and p, p′-DDD obtained by the SFC/ECD were 93.9 and 93.2%, respectively.  相似文献   

17.
袁宁  余彬彬  张茂升  曾景斌  陈曦 《色谱》2006,24(6):636-640
建立了微波辅助萃取-固相微萃取-气相色谱(MAE-SPME-GC)同时测定茶叶中六六六(α-BHC,β-BHC,γ-BHC,δ-BHC 4种异构体)、滴滴涕类(DDD,DDE,o,p′-DDT,p,p′-DDT)、氯氰菊酯(cypermethrin)和氰戊菊酯(fenvalerate)等10种农药残留的方法。采用外标法定量,除氰戊菊酯外,农药的质量浓度与其色谱峰面积在一定范围内有较好的线性关系,相关系数为0.9705~0.9984。10种组分的加标回收率为64%~121%,相对标准偏差为10.4%~22.9%,检测限为1~50 ng/L。应用该方法测定了市场上3种茶叶中上述农药残留的含量。  相似文献   

18.
侯靖  陈丹  涂凤琴  杨明  王梦颖  刘梦婷 《色谱》2021,39(11):1261-1272
建立了气相色谱-飞行时间质谱(GC-TOF-MS)同时测定食用植物油中197种农药残留的方法。样品经乙腈超声提取,冷冻除脂,C18和PSA吸附剂共同净化;目标物经HP-5MS UI毛细管柱(30 m×0.25 mm×0.25 μm)分离,电子轰击源电离,全扫描模式采集质谱信息;MassHunter软件对数据进行定性与定量分析,设置精确质量数偏差为±5×10-5,保留时间偏差为±0.1 min。实验考察了基质效应情况和方法学性能。结果表明,大多数农药表现出基质增强效应,需采用基质标准工作溶液进行定量。在优化的条件下,174种农药定量限可以达到0.01 mg/kg,占全部被测农药的88%,另外23种农药的定量限为0.025~0.1 mg/kg。除联苯的线性范围为2~100 μg/L外,其余农药的线性范围均为定量限~200 μg/L,相关系数(R2)均大于0.99。在3个添加水平(0.1、0.25和0.5 mg/kg)下,有156种农药的回收率为70%~120%,占全部被测农药的79%,有185种农药的相对标准偏差<10%,占全部被测农药的94%。应用该方法对23份市售植物油样品进行了检测,结果在12个样品中检出13种农药。该方法操作简便,一次进样即可实现近200种农药的同时检测,且检测结果的准确度和灵敏度良好,适用于食用植物油中197种农药残留的快速检测。  相似文献   

19.
建立了快速测定茶叶中八氯二丙醚(S-421)残留量的气相色谱方法。茶叶样品中的S-421经丙酮-石油醚混合液超声波辅助提取,用浓硫酸去除杂质,正己烷定容,用外标法定量,以气相色谱法(GC-μECD)进行测定。实验结果表明,样品中加入0.01~0.08 mg/kg浓度水平的八氯二丙醚,回收率为86.6%~106.5%,检出限为0.001 mg/kg,测定结果的相对标准偏差不大于8%(n=6)。  相似文献   

20.
张忠  王力春  鲁蕴甜 《色谱》2012,30(11):1113-1116
采用离子色谱法测定“地沟油”样品中钠离子和氯离子的含量,通过计算两者的比例关系确定样品中是否含有“地沟油”。使用去离子水提取“地沟油”样品中钠离子和氯离子。氯离子以20 nmol/L KOH溶液为淋洗液,AS19分离柱(250 mm×4 mm)分离,抑制器电流112 mA;钠离子以20 nmol/L甲基磺酸(MSA)为淋洗液,CS12分离柱(250 mm×4 mm)分离,抑制器电流59 mA;两者分离采用的其他相同色谱条件为: 柱温、检测器温度30 ℃,电导检测器检测,进样量25 μL,流量1 mL/min,峰面积定量。氯离子的检出限为0.005 mg/L,在0~5 mg/L范围内有良好的线性关系(r2=0.999988);钠离子的检出限为0.001 mg/L,在0~5 mg/L范围内有良好的线性关系(r2=0.999926)。氯离子平均加标回收率为94.2%,相对标准偏差(RSD)为2.4%;钠离子平均加标回收率为92.5%, RSD为2.7%。经测定、计算,正常食用油中钠离子和氯离子的物质的量比约为1,而“地沟油”中钠离子与氯离子的物质的量比高于4。“地沟油”中钠离子和氯离子的含量及其比例关系可作为判断“地沟油”的重要依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号