首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
A method based on ultra‐high performance liquid chromatography was developed and validated to detect six thyreostatic compounds: tapazole, thiouracil, methylthiouracil, dimethylthiouracil, propylthiouracil, and phenylthiouracil in faeces of bovine. Thyreostats were extracted from the matrix with a mixture of methanol and buffer (pH = 8). Next step was derivatization of analytes with 3‐iodobenzylbromide. The liquid chromatographic separation of derivatives was obtained on a SB‐C18 column (50 × 2.1 mm; 1.8 μm, Agilent) with gradient elution using a mobile phase consisting of acetonitrile/0.1% acetic acid within 7.5 min. The analysis was performed on a Shimadzu NEXERA X2 ultra‐high performance liquid chromatograph with triple quadrupole MS 8050 instrument operating in positive electrospray ionization mode. Depending on the target compound, two or three diagnostic signals (selected reaction monitoring transitions) were monitored. The procedure was validated according to the Commission Decision 2002/657/EC. Recovery and repeatability met the performance criteria specified by this document for banned compounds. The recovery ranged from 97.5 to 110.5%, and repeatability did not exceed 14.1%. Decision limits and detection capabilities were below 10 μg/kg. The highest decision limits and detection capabilities concentrations were observed for phenylthiouracil of 3.48 and 6.96 μg/kg, respectively.  相似文献   

2.
《Electrophoresis》2017,38(16):2011-2017
The suitability of an analytical method to determine oxolinic acid, danofloxacin, ciprofloxacin and enrofloxacin in edible tissues, based on micellar liquid chromatography coupled with fluorescence detection, to be applied in chicken, turkey, duck, lamb, goat, rabbit and horse muscle, is described. The method was fully matrix‐matched in‐lab revalidated, for each antimicrobial drug and meat, following the guidelines of the EU Commission Decision 2002/657/EC. The permitted limits were the maximum residue limits stated by the EU Commission Regulation 37/2010. The results obtained for the studied validation parameters were in agreement with the guidelines: selectivity (the antibiotics were resolved), linearity (r2  > 0.995), limit of detection (0.004–0.02 mg/kg), limits of quantification (0.01–0.05 mg/kg), calibration range (up to 0.5 mg/kg), recovery (89.5–105.0%), precision (<8.3%), decision limit, detection capability, ruggedness, stability and application to incurred samples. The method was found to be able to provide reliable concentrations with low uncertainty within a large interval, including the maximum residue limits, and then was useful to find out prohibited contaminated samples. The method did not require to be adapted for these matrices, and then it maintained its interesting advantages: short‐time, eco‐friendly, safe, inexpensive, easy‐to‐conduct, minimal manipulation and useful for routine analysis.  相似文献   

3.
In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C18 column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1–2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography–tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.  相似文献   

4.
An analytical method using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization for the determination of polycyclic aromatic hydrocarbons in asphalt fractions has been developed. The 14 compounds determined, characterized by having two or more condensed aromatic rings, are expected to be present in asphalt and are considered carcinogenic and mutagenic. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection ranged from 0.5 to 346.5 μg/L and the limits of quantification ranged from 1.7 to 1550 μg/L. The method was validated against a diesel particulate extract standard reference material (NIST SRM 1975), and the obtained concentrations agreed with the certified values. The method was applied to asphalt samples after its fractionation according to ASTM D4124 and the method of Green. The concentrations of the seven polycyclic aromatic hydrocarbons quantified in the sample ranged from 0.86 mg/kg for benzo[ghi]perylene to 98.32 mg/kg for fluorene.  相似文献   

5.
This paper represents the first report of a liquid chromatography coupled to electrospray ionization mass spectrometry method for simultaneously analyzing resveratrol and piceid isomers (cis and trans) in beeswax. An efficient extraction procedure has been proposed (average analyte recoveries were between 89 and 95%); this involved a solid–liquid extraction using a mixture of ethanol and water (80:20, v/v) and a concentration step in a rotary evaporator. The separation of all the compounds was achieved using a C18 column and a mobile phase composed of ammonium formate 0.03 M in water and acetonitrile in gradient elution mode at a flow rate of 1 mL/min. The method was fully validated in terms of selectivity, limits of detection and quantification, linearity, precision, and accuracy. The limits of detection and quantification ranged from 1.0 to 1.7 and 3.5 to 5.5 μg/kg, respectively. Finally, the proposed method was applied to analyze beeswax samples collected from experimental and organic apiaries.  相似文献   

6.
An easy, effective and sensitive analytical method for the simultaneous determination of a novel fungicide pyrametostrobin and its two metabolites pyrametostrobin‐M1 and pyrametostrobin‐M2 in cucumber and soil was developed using a quick, easy, cheap, effective, rugged, and safe method with high‐performance liquid chromatography and tandem mass spectrometry. The extraction solvent was acetonitrile, and cleanup sorbents were primary secondary amine and graphitized carbon black for cucumber samples and primary secondary amine for soil samples. The three target compounds were successfully separated between 3.2 and 3.9 min using a Waters CORTECS™ C18 column connected to an electrospray ionization source. All the matrix‐matched samples at three fortified levels (10, 100 and 1000  μg/kg) provided satisfactory recoveries in the range of 78.8–93.8% with relative standard deviations below 6.9%. The limits of quantitation for the three compounds were below 0.183 μg/kg. The proposed method was validated by analyzing real samples.  相似文献   

7.
A rapid, specific and highly sensitive multi-residue method for the determination of anabolic steroid residues in bovine, pork and poultry muscle tissues was developed. The sample preparation involves enzymatic digestion followed by extraction with methanol. The crude extract was cleaned up by solid-phase extraction (SPE) combining C18 and NH2 columns. The detection was carried out by a highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method using both positive and negative ionization modes. Natural and synthetic steroids covering different polarities could be extracted, concentrated and purified using one single method. Mobile phase composition and additives were optimized to achieve the highest sensitivity. The linearity was not good enough for quantitative analysis but the method was well-suited for qualitative confirmation. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) and detection capabilities (CCbeta) were below 0.5 ng g(-1) for all the compounds in the three types of meat studied. The developed method is suitable for routine analysis in our laboratories.  相似文献   

8.
An analytical method for the simultaneous and reliable determination of 20 antigout and antiosteoporosis pharmaceutical compounds in adulterated health food products was developed using liquid chromatography with electrospray ionization tandem mass spectrometry and liquid chromatography with quadrupole‐time‐of‐flight mass spectrometry. The method was validated through the determination of specificity, linearity, limit of detection, and limit of quantification, method detection limit, method quantitation limit, precision, accuracy, recovery, and stability. The matrix effect was also determined. The validation results of the developed method are as follows: for solid and liquid blank samples, limits of detection ranged from 0.05 to 5.00 ng/mL and limits of quantification ranged from 0.15 to 15.00 ng/mL. Linearity was acceptable, and the correlation coefficients (R2) were ≥0.99 for all target compounds. Both intra and interday precision were less than 9.16% RSD, and accuracies ranged from 95.31 to 116.68%. Mean recoveries for different types of dietary supplements classified as powders, liquids, tablets, and capsules were found to be 80.81 to 117.62% with less than 15.00% relative standard deviation. The stability of the standard mixture solution was less than 11.72% relative standard deviation after 48 h. By the proposed method, the presence of dexamethasone was determined in seized herbal food products at concentrations that ranged from 126 to 215 µg/g.  相似文献   

9.
A rapid and new liquid chromatography-mass spectrometry with ion-trap detection method for the determination of meloxicam (MLX), flunixin meglumine (FLU), carprofen (CPF), and tolfenamic acid (TOLF) in animal tissue is described. MRLs between 10 and 500 microg kg(-1) in muscle and between 65 and 1000 microg kg(-1) in liver, from different animal species have been established in the EU for these compounds. After chemical hydrolysis, an organic extraction from homogenised tissue was performed. Final extract was injected in a liquid chromatograph with an ion-trap mass spectrometer with electrospray interface. Four identification points (one precursor and two product ions) and a minimum of one ion ratio was monitored for each compound. For quantitative purposes flunixin-D3 (FLU-D3) was used as internal standard. The method was validated using fortified blank muscle and liver from different animal species according to the 2002/657/EC European decision criteria. The decision limits (CCalpha) and detection capabilities (CCbeta) were determined and their values were at concentrations near the MRL for each substance.  相似文献   

10.
A rapid and reliable method for the detection of five carbapenems (biapenem, imipenem, doripenem, meropenem, and faropenem) in water was developed and validated. After acidification of water samples with acetic acid, carbapenems were isolated using a Bond Elut PPL cartridge. The target compounds were separated using ultra high performance liquid chromatography with a chromatographic run time of 5 min and detected on a triple quadrupole mass spectrometer operated in positive electrospray ionization and multiple reaction monitoring mode. Mean recoveries were in the range of 76.6–106.5%, with satisfactory intraday and interday relative standard deviations lower than 10.0 and 10.8%, respectively. The limits of detection and quantification were in the ranges of 0.05–0.2 µg/L and 0.1–0.5 µg/L, respectively, depending on the analyte. The proposed method was applied to the analysis of river samples and wastewater samples from swine farms, and no carbapenems were detected in the collected samples.  相似文献   

11.
建立了采用同位素稀释-超高效液相色谱-串联质谱同时快速测定精油中7种雌性激素(雌三醇、雌二醇、雌酮、炔雌醇、己二烯雌酚、己烷雌酚、己烯雌酚)的方法。样品中雌性激素用乙酸乙酯-正己烷(2:98, v/v)溶液提取后,经硅胶固相萃取小柱净化,通过ACQUITY UPLCTM BEH SHELD RP18色谱柱(100 mm×2.1 mm, 1.7 μm)、以水-乙腈作流动相梯度洗脱对7种雌性激素进行分离,采用串联质谱在负离子扫描方式下通过多反应监测(MRM)模式进行定性定量分析。以雌三醇-D3、雌二醇-D3、己烯雌酚-D6为内标,有效减少了样品基质的影响。该方法对精油中7种雌激素的检出限(LOD)为0.3~7 μg/kg,定量限(LOQ)为1~20 μg/kg。待测物与内标物定量离子的峰面积比值与待测物的质量浓度在20~500 μg/L范围内呈良好的线性关系,相关系数(r2)均大于0.997;在20~500 μg/kg范围内3个水平的加标平均回收率为88.5%~114.8%,日内精密度(以相对标准偏差计)(n=6)为4.8%~18.9%。应用该方法对浙江杭州地区不同超市或美容院随机采集的12份精油样品进行测定的结果显示,有1份样品含有雌二醇和雌酮,其余11份样品均未检出雌性激素。  相似文献   

12.
郭德华  时逸吟  李优  伊雄海  邓晓军  肖文清  王键  李霄  柳菡  沈伟健 《色谱》2017,35(12):1216-1223
建立了液相色谱-四极杆飞行时间质谱(LC-QTOF MS)测定禽蛋及蛋制品中氟虫腈及其代谢物的快速筛查方法。样品经酸性乙腈提取,PRiME HLB SPE柱净化,Poroshell 120 EC C18色谱柱(150 mm×3 mm,2.7μm)分离,以水-乙腈为流动相,梯度洗脱,负离子模式下测定,以乙虫腈为内标定量。实验中建立了一级精确质量和二级碎片离子质谱数据库,并且对4种禽蛋及蛋制品的基质效应进行了考察。结果表明,氟虫腈及其代谢物在0.1~5μg/L范围内线性关系良好,相关系数(r2)均大于0.99。方法的检出限(LOD,S/N3)和定量限(LOQ,S/N10)分别为0.2μg/kg和1μg/kg。在不同基质中,氟虫腈及其代谢物在1、2和5μg/kg的添加水平下平均加标回收率为82.6%~98.1%,相对标准偏差为3.8%~9.9%(n=6)。该方法有效消除了液相色谱-四极杆飞行时间质谱检测过程中的离子化抑制效应,灵敏度和准确度高,适用于鸡蛋、鸡蛋面、蛋糕和蛋黄酱中氟虫腈、氟虫腈砜、氟虫腈亚砜和氟甲腈的快速筛查。  相似文献   

13.
A high-performance liquid chromatographic method with diode-array detection, at 351 nm, was developed and validated for the determination of five tetracyclines (TCs): minocycline, tetracycline, oxytetracycline, chlortetracycline, and doxycycline in bovine muscle. Samples were macerated with a buffer solution, centrifuged, and purified using Abselut Nexus SPE cartridges. The separation of the examined TCs was achieved on an Inertsil ODS-3 5 microm, 250 x 4 mm analytical column, at ambient temperature. A multistep gradient elution was followed using 0.05 M oxalic acid and CH3CN, at a flow rate of 1.65 mL/min. The procedure was validated according to the European Union regulation 2002/657/EC determining selectivity, stability, decision limit, detection capability, accuracy, and precision. The results of the validation process demonstrate that the method can be readily applied to European Union statutory veterinary drug residue surveillance programmes. Mean recoveries of TCs from bovine muscle samples spiked at three concentrations (100, 250, and 400 ng/g) were in the range of 98.7-103.3%. Method's LOQ values achieved were 40 microg/kg for MNC, CTC, and DC and 25 microg/kg for OTC and TC. The decision limits (CCalpha) were in the range of 104.7-109.8 microg/kg, while the detection capability (CCbeta) was in the range of 108.4-116.7 microg/kg for all compounds.  相似文献   

14.
An isocratic LC method for the determination of melamine and its degradation products (ammelide, ammeline, and cyanuric acid), used to increase the apparent protein content of rice protein concentrate, has been developed. Method development involved optimization of different RP columns, aqueous mobile phases, pH, phosphate concentration, and temperature. The optimum separation of these compounds was achieved using a Luna CN column (30 °C), 5 mmol L−1 sodium phosphate (pH 5.0) as mobile phase, 1 mL min−1 flow-rate, UV absorbance-DAD detection at 220 nm, and resorcine as internal standard; this enabled separation of these compounds with baseline resolution (values in the 2.1–10.1 range) in about 8 min. Prior to HPLC, the developed sample preparation procedure consisted in a leaching process using the above mentioned mobile phase. Method validation was carried out in rice protein concentrates in accordance with the European Commission decision 2002/657/EC criteria. For this purpose, eight mandatory performance characteristics for the conventional validation approach were determined: calibration graphs, extraction efficiencies, decision limits, detection capabilities, precision (repeatability and within-laboratory reproducibility), accuracy, selectivity, and robustness. The extraction efficiencies for these compounds were in the range 99–100% and the within-laboratory reproducibility at 1.0, 1.5, and 2.0 detection capabilities concentration levels were smaller than 5, 4, and 3%, respectively. Finally, the proposed method was successfully applied to the analysis of other rice protein concentrates and several animal feed samples.  相似文献   

15.
A simple and efficient multiresidue method using dispersive solid phase extraction and liquid chromatography coupled with tandem mass spectrometry was developed for the targeted analysis of indaziflam and its five metabolites (indaziflam‐diaminotriazine, indaziflam‐carboxylic acid, indaziflam‐triazine indanone, indaziflam‐hydroxyethyl, and indaziflam‐olefin) in pitaya samples (including roots, plants, flowers, peels, pulp, and whole fruit). The analytes were extracted with acetonitrile, and the extracts were purified using multiwalled carbon nanotubes. The method was validated using pitaya samples spiked at 0.5, 5, and 50 µg/kg, and the average recoveries varied from 61.1 to 103.7% with relative standard deviations lower than 12.7% (= 5). This method exhibited sufficient linearity within the concentration range of 0.1–100 µg/L. The limits of detection and quantification were in the ranges of 0.001–0.1 and 0.003–0.3 µg/kg, respectively. The method was successfully applied to analyze pitaya samples in Nanning, and no indaziflam or its metabolites were detected in the samples analyzed.  相似文献   

16.
A novel effervescent tablet‐assisted demulsified dispersive liquid–liquid microextraction based on the solidification of floating organic droplet was developed to determine methadone prior to gas chromatography with flame ionization detection and gas chromatography with mass spectrometry. In this method, a tablet composed of citric acid, sodium carbonate, and 1‐undecanol was utilized. The resulting effervescent tablet generated carbon dioxide in situ to disperse 1‐undecanol in the sample. Thus, the dispersive and extraction processes were performed in one synchronous step. An aliquot of acetonitrile as the demulsifier solvent was used for the separation of two phases instead of centrifugation. Under optimal conditions, the developed method was linear up to 50 000 µg/L with correlation coefficients higher than 0.99. Moreover, limits of detection and limits of the quantification were in the range of 3‐10  and 7‐30 µg/L in water and biological samples, respectively. Intra‐ and interday precisions (n = 6) of the spiked methadone at a concentration level of 50 µg/L were over ranges of 5.1‐6.8% and 5.7‐7.1%, respectively. The preconcentration factors and recovery values were obtained in the range of 140‐145 and 98.1 to 101.6% in real samples, respectively.  相似文献   

17.
A highly selective molecularly imprinted polymer sorbent was synthesized and employed for the simultaneous determination of six sulfonamide antibiotic residues (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfamerazine, and sulfamethizole) in milk samples. Multi‐analyte imprinted particles were used as a sorbent in solid‐phase extraction. Sulfonamides were separated on a high‐performance liquid chromatography column (Merck–Lichrospher RP18e, 5 μm 250 × 4 mm) and further identified and quantified by diode array detection. Several parameters including required loading of the molecularly imprinted polymer sorbent, mass of milk, volume, and type of elution solvent, as well as time for absorption and elution were investigated to obtain optimal experimental conditions. For comparison purpose, a non‐imprinted polymer was applied under the optimum conditions. The validation study according to the European Union Decision 2002/657/EC was based on the investigation of linearity, selectivity, stability, limits of detection and quantitation, decision limit, detection capability, trueness, precision, and ruggedness according to Youden's approach. The decision limit and detection capability values in the milk were achieved from 101.9 to 113.5 μg/kg and from 114.4 to 135.4 μg/kg, respectively, depending on the target sulfonamide drug. Finally, the optimized protocol was successfully applied to commercial milk samples and human breast milk.  相似文献   

18.
A modified quick, easy, cheap, effective, rugged and safe method was established for simultaneous determination of atropine, anisodamine, and scopolamine in goji berries by using ultra‐high‐performance liquid chromatography with tandem mass spectrometry. The graphene/hexagonal boron nitride hybrids were prepared and first applied as a cleanup adsorbent. Compared to classical cleanup adsorbent (C18), the graphene/hexagonal boron nitride hybrids as adsorbent had better extraction efficiency for the detection of analytes. Under the optimal conditions, the proposed analytical method achieved satisfactory linearity (R> 0.995), and obtained desirable recoveries ranged from 77.4 to 94.0% with the relative standard deviation of 1.2–6.1% at the concentration levels of 3.2–13.4 µg/kg. The limits of quantitation of atropine, anisodamine, and scopolamine were, respectively, 3.2, 4.6, and 4.5 µg/kg with linearity ranged from 3.2 to 25.4 µg/kg. The modified quick, easy, cheap, effective, rugged, and safe sample preparation with ultra‐high‐performance liquid chromatography and tandem mass spectrometry method was successfully applied to evaluate the safety of goji berries collected from 30 plant areas in China, suggesting its applicability and suitability for the routine analysis of three tropane alkaloids in goji berries.  相似文献   

19.
A sensitive and effective method for the simultaneous determination of residues from a new fungicide, oxathiapiprolin, and its metabolites (IN‐E8S72 and IN‐WR791) in soil, water, and sediment, was developed using ultra high performance liquid chromatography with tandem mass spectrometry. Three compounds were extracted from water, soil, and sediment by using acetonitrile and different proportions of formic acid aqueous solution (1% v/v for water; 2% v/v for soil; and sediment), and were cleaned with octadecylsilane. The target compounds were determined within 5 min using an electrospray ionization source in the positive mode for oxathiapiprolin and in the negative mode for the two metabolites. The limits of quantification for all the three compounds were 0.1 μg/kg in water and 1 μg/kg in soil and sediment. Recovery studies were performed using three spiked levels (0.1, 1, and 10 μg/kg for water; 1, 10, and 50 μg/kg for soil and sediment). The overall average recoveries ranged from 64.8 to 112.7% with all intra‐ and interday relative standard deviation values below 19.4 and 19.1%, respectively. The method validation confirmed that the proposed method was convenient and reliable for determining residual oxathiapiprolin and its metabolites in soil, water, and sediments.  相似文献   

20.
《Analytical letters》2012,45(17):2673-2689
A high-performance liquid chromatography–UV/VIS detection–electrospray ionization single quadrupole mass spectrometry (HPLC–UV/VIS–ESI-MS) method was developed to separate oxidative and photolytic degradation products of aryldiamines, that is, para-phenylenediamine and para-toluenediamine. The separation was performed on a polar modified reversed phase-C18 column which provided superior chromatographic resolution compared to conventional columns. Gradient elution was used with the mobile phases of water and acetonitrile containing 10 mM ammonium acetate. Various compounds including aryldiamines, benzoquinones, aromatic nitro compounds, and azobenzenes were selected for an optimization of the ESI-MS operation and the chromatographic separation conditions. Highly linear calibrations (r2 > 0.999) were achieved for a subset of 5 standard substances. Using analyte-specific UV detection wavelengths, limits of detection and limits of quantitation of these substances ranged from 3.0 to 7.0 µg L?1 and from 10.0 to 23.3 µg L?1, respectively. The analysis of aqueous solutions of para-toluenediamine photolysis products confirmed the performance of the method. Up to 28 chromatographic signals were recorded and the change of their peak heights during the transformation process was monitored for 24 hours. The identities of the compounds were ascertained by means of MS detection correlations between molecular features and the chromatographic retention of the compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏