首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A novel dispersive liquid‐liquid microextraction that combines self‐induced acid‐base effervescent reaction and manual shaking, coupled with ultra high performance liquid chromatography with tandem mass spectrometry was developed for simultaneous determination of ten neonicotinoid insecticides and metabolites in orange juice. An innovative aspect of this method was the utilization of the acidity of the juice for a self‐reaction between acidic components contained in the juice sample and added sodium carbonate which generated carbon dioxide bubbles in situ, accelerating the analytes transfer to the extractant of 1‐undecanol. The total acid content of juice sample was measured to produce the maximum amount of bubbles with minimum usage of carbonate. Manual shaking was subsequently adopted and was proven to enhance the extraction efficiency. The factors affecting the performance, including the type and the amount of the carbon dioxide source and extractant, and ionic strength were optimized. Compared with conventional methods, this approach exhibited low limits of detection (0.001–0.1 µg/L), good recoveries (86.2–103.6%), high enrichment factors (25–50), and negligible matrix effects (?12.3–13.7%). The proposed method was demonstrated to provide a rapid, practical, and environmentally friendly procedure due to no acid reagent, toxic solvent, or external energy requirement, giving rise to potential application on other high acid‐content matrices.  相似文献   

2.
Resorcinol–formaldehyde aerogel coating was in situ prepared on the surface of basalt fibers. The aerogel coating is uniformly modified onto basalt fibers, and it is very porous according to the characterization by using scanning electron microscopy. An extraction tube was prepared for in‐tube solid‐phase microextraction by placing the aerogel‐coated basalt fibers into a polyetheretherketone tube. To evaluate the extraction performance toward five estrogenic compounds, the tube was connected with high performance liquid chromatography, the important extraction and desorption conditions were investigated. An online analytical method for detection of estrogens was developed and presented low limits of detection (0.005–0.030 µg/L), wide linear ranges (0.017–20, 0.033–20, and 0.099–20 µg/L), good linearity (r > 0.9990), and satisfactory repeatability (relative standard deviation < 2.7%). The method was successfully applied to detect trace estrogens in real water samples (bottled pure water and bottled mineral water), satisfactory recoveries were ranged from 80 to 125% with two spiking levels of 2 and 6 µg/L.  相似文献   

3.
Triazine‐based organic polymers@SiO2 nanospheres were prepared and applied as an extraction coating onto stainless steel wires and the wires were filled into polyetheretherketone tube for in‐tube solid‐phase microextraction. Taking polycyclic aromatic hydrocarbons as targets, main factors affecting extraction performance of the tube were investigated through coupling to high performance liquid chromatography. Under the optimum conditions, an online analytical method for polycyclic aromatic hydrocarbons was established with large linear ranges (0.010‐20 µg/L), low limits of detection (0.003‐0.010 µg/L), high enrichment factors (533‐2954), and good repeatability (relative standard deviations <1.7% for intraday test, <5.0% for interday test). The analysis method was successfully applied to the detection of trace targets in real water samples and the relative recoveries ranged from 82.9 to 119.9%, which demonstrated the applicability of extraction tube in sample preparation.  相似文献   

4.
A high‐performance liquid chromatography method was developed for simultaneous detection and quantitation of total cysteine, glutathione, homocysteine and cysteinylglycine in human plasma. The two key steps in the analysis are reduction of disulfides and treatment with 1‐benzyl‐2‐chloropyridinium bromide, which rapidly and quantitatively reacts with thiol groups to form stable S‐pyridinium derivatives with intense UV absorption. The derivatives are well separated on a Zorbax SB C18 column using reversed‐phase high‐performance liquid chromatography and monitored at 315 nm. The calibration graphs were linear over concentration ranges covering most experimental and clinical cases with a regression coefficients better than 0.999. The detection and quantitation limits for all analytes were 0.2 and 0.5 µmol/L, respectively. The recoveries were 99.25–101.68%. The intra‐ and interassay imprecisions were 0.88–4.24 and 1.68–5.14%, respectively. The method was applied for plasma samples donated by apparently healthy volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
Phthalate esters are easily released from plastics materials and migrate into the soil and water environment, causing serious pollution and posing a great threat to the health of human beings. A novel temperature‐sensitive extractant combined with liquid–liquid microextraction was developed to preconcentrate three phthalates in the water environment. To optimize the extraction efficiency for the three phthalate esters, various parameters, including polymer molecular weight, salt type, salt addition, adsorption time, desorption solvent, desorption volume, and desorption time have been studied. Under optimal conditions, limits of detection and limits of quantification were in the range of 0.007–0.120 and 0.021–0.350 µg/L, respectively. Linearities varied in the range of 5–1000 µg/L, with the correlation coefficients of 0.9867–0.9997. The preconcentration factors were in the range of 25–75. The relative recoveries of the three phthalate esters were in the range of 82.2–105.6% at the spiked levels. The relative standard deviations were in the range of 0.7–9.2% based on triplicate measurements. The results indicate that the temperature‐sensitive material is a good extractant for phthalate esters in water samples.  相似文献   

6.
A novel plate‐like nano‐sorbent based on copper/cobalt/chromium layered double hydroxide was synthesized by a simple coprecipitation method. The synthesized nanoparticels were introduced into a stainless steel cartridge using a dry packing method. Then, the packed cartridge was introduced as a novel on‐line “packed in‐tube” configuration and followed by high performance liquid chromatography for the determination of trace amounts of ?9‐tetrahydrocannabinol from biological samples and cannabis leaves. The as‐prepared sorbent exhibited long lifetime, good chemical stability, and high anion‐exchange capacity. Several important factors affecting the extraction efficiency, such as extraction and desorption times, pH of the sample solution and flow rates of the sample and eluent solutions, were investigated and optimized. Under optimized conditions, this method showed good linearity for ?9‐tetrahydrocannabinol in the ranges of 0.09–500, 0.3–500, and 0.4–500 µg/L with coefficients of determination of 0.9999, 0.9991, and 0.9994 in water, serum and plasma samples, respectively. The inter‐ and intra‐assay precisions (n = 3) were respectively in the ranges of 1.8–4.6% and 1.9–4.0% at three concentration levels of 10, 50, and 100 µg/L. The limits of detection were also in the range of 0.02–0.1 µg/L.  相似文献   

7.
Polypropylene hollow fibers as the adsorbent were directly filled into a polyetheretherketone tube for in‐tube solid‐phase microextraction. The surface properties of hollow fibers were characterized by a scanning electron microscope. Combined with high performance liquid chromatography, the extraction tube showed good extraction performance for five environmental estrogen hormones. To achieve high analytical sensitivity, four important factors containing sampling volume, sampling rate, content of organic solvent in sample, and desorption time were investigated. Under the optimum conditions, an online analysis method was established with wide linear range (0.03–20 µg/L), good correlation coefficients (≥0.9998), low limits of detection (0.01–0.05 µg/L), low limits of quantitation (0.03–0.16 µg/L), and high enrichment factors (1087–2738). Relative standard deviations (n = 3) for intraday (≤3.6%) and interday (≤5.1%) tests proved the stable extraction performance of the material. Durability and chemical stability of the extraction tube were also investigated, relative standard deviations of all analytes were less than 5.8% (n = 3), demonstrating the satisfactory stability. Finally, the method was successfully applied to detect estrogens in real samples.  相似文献   

8.
Detecting pesticide residues in human serum is a challenging process. In this study we developed and validated a method for the extraction and recovery of residues of multiple classes of pesticides from serum using one reagent. Salt‐assisted acetonitrile extraction and high‐performance liquid chromatography with quadrupole time of flight tandem mass spectrometry were used to quantitate 34 pesticides classified in nine groups of chemicals in human serum samples, which are frequently detected in food. The recoveries for 33 of analyzed pesticides ranged from 86 to 112% with relative standard deviations below 15%. The limits of quantitation and linearity of 31 of the pesticides were 1 µg/L and >0.990, respectively. The lower limit of quantitation has been reported in the literature particularly for multi‐classes pesticide mixtures in human serum. The salt–acetonitrile reagent was allowed to achieve good recoveries and detection limits, which could be attributed to salt altering the solvent polarity, preferentially collecting the organic phase in the solution, and promoting the extraction. The developed method was applied for two organophosphate pesticide metabolites, diethylphosphate and 3,5,6‐trichloro‐2‐pyridinol, in serum from rats that were fed a nonlethal quantity of chlorpyrifos. The concentrations of these two were 252.18 ± 15.47 and 0.63 ± 0.23 µg/L, respectively.  相似文献   

9.
In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption‐based dispersive liquid‐liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte‐containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5–500 µg/L with a coefficient of determination of R= 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84–120%) and acceptable relative standard deviation (1.8–14.9%, = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.  相似文献   

10.
The herbicides in naked oat (Avena nuda L.) samples were extracted, separated, and determined by using ionic‐liquid‐based matrix solid‐phase dispersion‐solvent flotation coupled with high‐performance liquid chromatography. The experimental parameters were optimized and evaluated by a univariate method and orthogonal experiment. A good linear relationship was obtained in the range of 5–5000 µg/kg, and the linear correlation coefficient are between 0.9989~0.9993. The quantification limits for alachlor, metazachlor, propanil, acetochlor, pretilachlor, metolachlor, and butachlor are 5.03, 2.62, 2.73, 4.58, 7.28, 5.05, 5.78 µg/kg, respectively. The average recoveries of the acetanilide herbicides at spiked concentrations of 10, 100, and 500 µg/kg ranged from 92.1 to 104.7%, and relative standard deviations were equal to or lower than 2.9%.  相似文献   

11.
A fluorescent nanoprobe based on sodium lignosulfonate derived carbon quantum dots (SLS-CQDs) was fabricated through a facile and sustainable one-step hydrothermal treatment. The obtained SLS-CQDs had excellent fluorescence properties and were applied to detect total Mn and ascorbic acid (AA). The fluorescence of SLS-CQDs could be effectively quenched by Mn based on a static quenching process and recovered by the addition of AA. An “on–off-on” fluorescent nanoprobe was established to determine total Mn and AA with the detection limits of 6.9 µg/L and 0.65 µM with the corresponding linear ranges of 0.25–2.25, 5–25 mg/L, and 5–110 µM, respectively. This nanoprobe could accurately detect total Mn in surface water and AA in Vitamin C effervescent tablet samples. The proposed method is simple and can be performed easily, indicating that SLS-CQDs might be used in environmental monitoring, food and drug testing.  相似文献   

12.
Electromembrane extraction was used with high‐performance liquid chromatography for preconcentration and determination of ampicillin residues in cow milk. Ampicillin is transferred from an aqueous solution through a thin layer containing octan‐1‐ol, silver nanoparticles, and reduced graphene oxide which serves as a supported liquid membrane. Inside the fiber impregnated with supported liquid membrane mixture was filled 10 µL of an acceptor phase. Experimental parameters were optimized for extraction efficiency of ampicillin. Under the optimized conditions, the proposed method provided acceptable linear range (2–100 µg/L), satisfactory repeatability (RSD% < 7.1), low limit of detection (0.6 µg/L), and a high enrichment factor (295) corresponding to extraction recovery of 37%. Consequently, the proposed method was successfully applied for the determination of ampicillin residues in different cow milks.  相似文献   

13.
A fast, green, sensitive, and accurate analytical method using high‐performance liquid chromatography couple with fluorescence detection was established and validated for the simultaneous determination of amlodipine besylate and celecoxib in their recently approved fixed‐dose combination tablets (1:20). Separation of the two drugs was achieved on C18 reversed‐phase column (Thermo ODS Hypersil, 4.6 × 250 mm, particle size 5 µm) using acetonitrile:potassium phosphate buffer (50 mM; pH 5.5, 60:40 v/v) as a mobile phase at 40°C, which eluted at a rate of 1 mL/min. Detection was carried out with excitation and emission wavelengths of 360 and 446 nm for amlodipine and 265 and 359 nm for celecoxib, respectively. The method was linear over a concentration range of 0.05‐2 and 0.05‐10 µg/mL and limit of detection reached to 0.017 and 0.0167 µg/mL for amlodipine and celecoxib, respectively. The developed method was successfully applied to assess the cited drugs in their newly FDA approved fixed‐dose combination tablet dosage form. Furthermore, the method was found to be sensitive and eco‐friendly green alternative to the reported methods as it was evaluated according to the green analytical procedure index tool guidelines and analytical Eco‐Scale.  相似文献   

14.
A simple and sensitive method based on the combination of solid‐phase microextraction (SPME) and high‐performance liquid chromatography with ultroviolet detection was developed for the simultaneous determination of clenbuterol, salbutamol and ractopamine in pig samples. Parameters of the SPME procedure affecting extraction efficiency, such as the type of fiber, extraction time, extraction temperature, ion strength, pH of sample and stirring rate, were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.5–50 µg/L for clenbuterol and ractopamine, and 0.2–20 µg/L for salbutamol. The limits of detection were 0.1 µg/L for clenbuterol, 0.05 µg/L for salbutamol and 0.1μg/L for ractopamine, respectively. The averages of intra‐ and inter‐day accuracy ranged from 79.8 to 92.4%. The intra‐day and inter‐day precision were below 9.6% for the three analytes. This method exhibited the advantages of simplicity, rapidity and low solvent consumption, and was suitable for the monitoring of β2‐agonists residue in pig samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
An on‐line, fast, simple, selective, and sensitive method has been developed for the determination of three herbicides belonging to the following families: triazines (atrazine), chloroacetamide (alachlor), and phenoxy (2,4‐dichlorophenoxyacetic acid) in water samples. The method involves an in‐syringe magnetic stirring‐assisted dispersive liquid–liquid microextraction along with simultaneous silylation prior to their determination by gas chromatography with mass spectrometry. Extraction, derivatization, and preconcentration have been simultaneously performed using acetone as dispersive solvent, N‐methyl‐Ntert‐butyldimethylsilyltrifluoroacetamide as derivatization agent and trichloroethylene as extraction solvent. After stirring for 180 s, the sedimented phase was transferred to a rotary micro‐volume injection valve (3 μL) and introduced by an air stream into gas chromatograph with mass spectrometry detector. Recovery and enrichment factors were 87.2–111.2% and 7.4–10.4, respectively. Relative standard deviations were in the ranges of 6.6–7.4 for intraday and 9.2–9.6 for interday precision. The detection limits were in the range of 0.045–0.03 μg/L, and good linearity was observed up to 200 μg/L, with R2 ranging between 0.9905 and 0.9964. The developed method was satisfactorily applied to assess the occurrence of the studied herbicides in groundwater samples. The recovery test was also performed with values between 77 and 117%.  相似文献   

16.
The present work describes a simple route to magnetize MIL‐53(Al)‐NH2 sorbent for rapid extraction of phenol residues from environmental samples. To extend the applications and performances of the metal‐organic frameworks in the field of adsorption materials, we combined the properties of metal‐organic frameworks and magnetite to decrease the extraction time and simplify the extraction process as well. In this study, a simple and quick vortex‐assisted dispersive magnetic solid phase extraction method for the extraction of ten United States Environmental Protection Agency's priority phenols from water samples prior to analysis by high‐performance liquid chromatography with photodiode array detection was proposed. The developed method exhibits a rapid enrichment of the target analytes within 10 s for extraction and 10 s for desorption. Low detection limits of 1.8‐41.7 µg/L and quantitation limits of 6.0‐139.0 µg/L with the relative standard deviations for intra‐ and interday analyses less than 12% were achieved. Satisfactory recoveries in the range of 80‐111% with the relative standard deviations less than 11% demonstrated that Fe3O4/MIL‐53(Al)‐NH2 is promising sorbent in the field of magnetic solid‐phase extraction for environmental samples.  相似文献   

17.
A new analytical method based on dispersive liquid–liquid microextraction with gas chromatography mass spectrometry has been optimized for the simultaneous determination of paclobutrazol and triflumizole in tap water and wastewater samples. A two‐level, full‐factorial design that allowed the study of main effects and factor interactions was applied to analyze the influence on microextraction process by chloroform, ethanol, potassium iodide and hand shaking period. The extraction conditions selected were 200 μL of chloroform, 3.0 mL of ethanol, 2.0 g of potassium iodide and 15 s of hand shaking. The limits of detection obtained for triflumizole and paclobutrazol under optimum conditions were 0.97 and 0.29 ng/mL, respectively. Calibration plots of both analytes were linear over a wide concentration range, and good precision was observed for replicate measurements. Applicability and accuracy of the method were determined by performing spiked recovery tests. Appreciable recovery results were obtained for municipal wastewater and matrix matching was used to obtain close to 100% recovery for tap water.  相似文献   

18.
Jin‐Mu‐Gan‐Mao tablet is a well‐known traditional Chinese medicinal preparation, which has been used to treat the common cold in China. In this study, a systematic method was established for the qualitative and quantitative analysis of the major constituents in Jin‐Mu‐Gan‐Mao tablet. First, a method of high‐performance liquid chromatography with diode‐array detection and quadrupole time‐of‐flight mass spectrometry was developed for identification of the multi‐constituents. Thirty‐one compounds including ten phenolic acids, 18 flavonoids, and three iridoid glycosides were clearly identified by comparison with the reference standards, and 11 compounds were deduced by comparison with the literature data. Second, a new quantitative analysis method of Jin‐Mu‐Gan‐Mao tablet was established by high‐performance liquid chromatography with diode‐array detection. Twelve compounds, either with high contents or strong bioactivities, were chosen as marker components. This analytical method was validated through intra‐ and interday precision, repeatability, and stability, with respective relative standard deviations less than 1.74, 2.54, 2.44, and 2.48%. The limits of detection and quantification were less than 0.327 and 0.881 μg/mL, respectively. The overall recoveries ranged from 97.04–102.76% (relative standard deviation ≤ 2.91%). Then this validated method was applied to determine ten batches of Jin‐Mu‐Gan‐Mao tablet. The results indicated that these new approaches can be applicable for the qualitative and quantitative analysis of Jin‐Mu‐Gan‐Mao tablet.  相似文献   

19.
We describe an optimization approach to determine simultaneously occurring chelating agents (glycine, malonic acid, citric acid, glycolic acid, lactic acid, DL‐malic acid, and ethylenediaminetetraacetic acid) in an electroplating effluent using high‐performance liquid chromatography. With chromatography signal area and overall resolution considered as responses, detection conditions were optimized via multiple functions combined with response surface methodology and Plackett–Burman design. Optimized detection conditions were as follows: 15 mmol/L ammonium phosphate buffer (pH 2.5), a 94:6 v/v ratio of ammonium phosphate buffer/acetonitrile, a column temperature of 23.3°C, and a mobile phase flow rate of 1 mL/min. The experimental values conformed to the predicted values and were repeatable (relative standard deviation < 6.4%) and linear (r> 0.991) over concentration ranges of 1–100 µmol/L. Moreover, the quantification limit (signal‐to‐noise ratio = 10) and the detection limit (signal‐to‐noise ratio = 3) ranged from 0.03 to 0.15 µmol/L and from 0.01 to 0.04 µmol/L, respectively. These results indicate that high‐performance liquid chromatography coupled with statistical design may be a simple and rapid method for simultaneously determining multiple chelating agents in electroplating wastewater effectively.  相似文献   

20.
An environmentally friendly ionic liquids dispersive liquid–liquid microextraction (IL‐DLLME) method coupled with high‐performance liquid chromatography (HPLC) for the determination of antihypertensive drugs irbesartan and valsartan in human urine samples was developed. The HPLC separations were accomplished in less than 10 min using a reversed‐phase C18 column (250 × 4.60 mm i.d., 5 µm) with a mobile phase containing 0.3 % formic acid solution and methanol (v/v, 3:7; flow rate, 1.0 mL/min). UV absorption responses at 236 nm were linear over a wide concentration range from 50 µg/mL to the detection limits of 3.3 µg/L for valsartan and 1.5 µg/L for irbesartan. The effective parameters on IL‐DLLME, such as ionic liquid types and their amounts, disperser solvent types and their volume, pH of the sample and extraction time were studied and optimized. The developed IL‐DLLME‐HPLC was successfully applied for evaluation of the urine irbesartan and valsartan profile following oral capsules administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号