首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 156 毫秒
1.
基于微顺序注射-阀上实验室,采用磷钼蓝分光光度法测定了海水中总磷,对实验参数进行了优化,并选取了海水中主要成分离子进行了干扰实验。结果表明,海水中总磷质量浓度在0.009~1mg/L范围内与吸光度呈线性关系(r=0.9995),方法的检出限为0.003mg/L。该法测定秦皇岛黄金海岸表层海水中总磷浓度为0.090mg/L,与国标法测定结果0.088mg/L无显著性差异;测定含磷浓度为0.20mg/L的人工海水,相对标准偏差(RSD)为2.4%,样品加标回收率为94.4%~95.7%;海水中主要离子对本实验方法测定产生的干扰在5%以内。  相似文献   

2.
采用紫外消解–流动注射分光光度法测定海水养殖废水中总氮和总磷。总氮样品浓度在0.050~5.00mg/L范围内,总磷样品浓度在0.020~5.00 mg/L范围内均与峰高有良好的线性关系(r分别为0.999 90和0.999 94)。在盐度为35,进样时间为70 s,清洗时间为90 s的条件下,总氮和总磷的检出限分别为0.050mg/L和0.020 mg/L,测定结果的相对标准偏差分别为1.15%,0.60%(n=6),加标回收率分别为98.7%~101.2%和98.6%~102.5%。该方法能满足海水养殖废水中总氮和总磷的监测要求。  相似文献   

3.
采用流动注射在线分析法测定水源水中总氮的含量。研究了样品预处理过程中水样浊度干扰、实验用水、试剂纯度选择、试剂配制及存放、气泡的干扰、干扰物的消除、显色剂浓度优化等对实验结果的影响。在磺胺和盐酸萘乙二胺溶液的质量浓度分别为35、1 g/L的最优条件下,水源水中的总氮质量浓度在0.040~10.0 mg/L范围内与吸收峰面积具有良好的线性关系,相关系数为0.999 9。水源水中总氮的检出限为0.010 mg/L,加标回收率为92.5%~105%,测定结果的相对标准偏差为0.22%~1.10%(n=6)。该方法运行成本低,操作方便,分析速度快,稳定性和安全性好,适用于大批量水源水中总氮的测定,能够满足水源水监测的技术要求。  相似文献   

4.
采用离子交换色谱法同时定量分析脱硫海水中SO_4~(2-)和SO_3~(2-)。0.01 mol/L EDTA和0.10×10~(-3) mol/L NaOH混合溶液用于除去海水样品中Ca~(2+)、Mg~(2+)干扰,加入0.5%的甲醛溶液防止SO_3~(2-)氧化为SO_4~(2-)。实验采用DINOEX AS-9HC阴离子交换柱作分离柱,以9.00×10~(-3) mol/L Na_2CO_3溶液为淋洗液,电导检测器检测。方法线性范围为5.00~100.00 mg/L,加标回收率为97.85%~103.99%,相对标准偏差(RSD)为0.20%~2.07%。SO_3~(2-)的检出限为0.03mg/L,SO_4~(2-)的检出限为0.04mg/L。结果表明,本方法可以有效消除海水中Ca~(2+)、Mg~(2+)对低浓度SO_3~(2-)、SO_4~(2-)测定的干扰,可同时实现海水脱硫体系中SO_3~(2-)、SO_4~(2-)的定量分析。  相似文献   

5.
建立了大气和海水中挥发性硫化物的气相色谱分析方法,确定了最佳实验条件.为了适应不同的基质和保存方式,大气和海水样品采用了不同的分析方法.测定大气样品时,采用大气采样罐及三级冷阱预浓缩气相色谱-质谱联用技术,而海水样品采用吹扫捕集-气相色谱测定.本方法测定大气挥发性硫化物的线性范围较好,精密度为7.7%~15.1%,检出限为0.23~4.7 ng;海水中挥发性硫化物的精密度为3.5%~5.3%,检出限为2.5~3.5 ng.将本方法用于青岛近海海水和大气中硫化物的测定,测得海水中羰基硫、二甲基硫和二硫化碳的平均浓度分别为(268±58)pmol/L、(1264±0.2)pmol/L、(19±2)pmol/L,大气中的平均浓度为543±39、39±9和56±20(×10-12,V/V).本方法可准确测定海洋环境中的挥发性硫化物.  相似文献   

6.
以国家标准GB/T 12763.4-2007中的碱性过硫酸钾氧化法和GB/T 11894-1989中淡水总氮测定的紫外分光光度法为基础对海水总氮测定方法进行了改进。在改进的方法中减少了物质转化步骤,相应减少了样品转移次数与定量移取步骤。该方法测定总氮量的线性范围在57.74mg·L-1(以KNO3计)以内。该方法的有机氮物质氧化率为(99.1±5.6)%,加标氧化率为(100.4±4.2)%,以海水样品为基体的加标回收率为(107.3±15.3)%。对海水样品及20,40μmol·L-1硝酸钾标准溶液的测得结果与已知值无显著差异。  相似文献   

7.
基于苯胺与亚硝酸盐的重氮化反应及反应产物与甲萘酚的显色,借助流动分析技术,实现了海水中苯胺含量的分析测定。体系以30.9g/L的NaCl做载液、人工海水配制标准样品,对各个影响因素进行了优化。苯胺浓度在0.01~1.0mg/L范围内与相对峰高呈线性关系,线性方程ΔH(mV)=200.53ρ+1.0728(n=8,ρ为苯胺浓度mg/L),相关系数R2=0.9982。方法的检出限(3σ)为0.005mg/L,相对标准偏差(RSD)为4.8%(n=11)。考察了共存离子、不同盐度样品对分析测定的影响。用于实际海水样品的分析,回收率为95.8%~106.6%。  相似文献   

8.
通过高温燃烧法测定了水质总氮含量,与K2S2O8氧化-紫外分光光度法进行比较,高温燃烧法的测定结果准确可靠。方法的检出限为0.05 mg/L,测定下限为0.20 mg/L,样品测定的RSD为0.9%~4.6%,加标回收率为97.4%~103%。对于有悬浮物干扰的水样,可以超声粉碎后测定;Fe3+,Cr6+和卤素离子对高温燃烧法测定总氮无干扰。  相似文献   

9.
建立快速测定水中化学需氧量(COD)的重铬酸钾光度法。样品消解温度为165℃,消解时间为15 min。当水中含有氯离子时,可加入硫酸汞掩蔽剂消除氯离子影响,其加入量按每毫克氯离子加入20 mg硫酸汞计算。该方法检测范围为20~800 mg/L,当水中COD质量浓度大于800 mg/L时应先进行稀释,然后测定;当COD质量浓度小于20 mg/L时,可以采用真空蒸馏法浓缩,以提高COD质量浓度。采用该方法对COD质量浓度为300 mg/L的标准溶液进行测定,测定结果的相对标准偏差为0.7%(n=6),相对误差为-2.0%。分别采用所建方法和国家标准方法HJ 828—2017(重铬酸钾回流消解滴定法)测定两个不同水样,相对偏差分别为-1.6%和-1.1%。该方法适用于水中COD的快速测定。  相似文献   

10.
建立浓海水中氯酚的顶空固相微萃取气相色谱法检测方法。采用顶空固相微萃取对海水淡化排放的浓海水样品中2,4,6-三氯酚(2,4,6-TCP)和五氯酚(PCP)进行分离富集,气相色谱-电子捕获检测器(μECD)测定浓海水样品中2,4,6-TCP和PCP的含量。讨论了萃取时间、萃取温度、水样盐度等实验条件对富集效率的影响,确定了萃取时间为40 min,萃取温度为60℃。2,4,6-TCP,PCP的质量浓度在0.500~20.0μg/L范围内与其色谱峰面积呈良好的线性关系,线性相关系数均大于0.999,2,4,6-TCP和PCP的检出限(2S/N)分别为0.055,0.128μg/L,测定结果的相对标准偏差为3.65%~11.4%(n=6),加标回收率为73.5%~119.0%。该方法快速,灵敏度高,适合于浓海水中氯酚的分析。  相似文献   

11.
采用紫外光-臭氧氧化结合离子色谱法对氧化消解后的水样同时进行总磷和总氮的测定。配制Na2CO3/NaHCO3淋洗液,采用1 mL定量环,大体积直接进样。在优化工作条件下,总磷在0.05~5.00 mg/L,总氮在0.10~10.0 mg/L范围内线性良好,线性相关系数分别为0.9999和0.9998,总磷和总氮检出限为分别3.60和4.57μg/L;总磷和总氮的检测相对标准偏差(RSD)分别低于4.9%和4.1%,总磷加标回收率为95.0%~105.0%,总氮加标回收率为93.0%~103.0%。自然环境水样检测与真实值相对偏差小于4.2%。本方法选择性好,灵敏度高,精密度和准确度高,用于实际水样中总磷和总氮含量测定的结果与国标法(GB11894-89,GB11893-89)基本一致  相似文献   

12.
利用微波消解仪消解土壤样品,采用电感藕合等离子体发射光谱仪测定土壤中硫的含量。以浓王水为消解试剂,对土壤样品进行微波消解,优化了王水用量,考察了微波消解条件、谱线干扰情况和仪器参数对硫灵敏度的影响。硫的质量浓度在0~40 mg/L范围内与光谱强度具有良好的线性关系,线性相关系数为0.9997,硫的检出限为0.053 mg/L。土壤中硫测定结果的相对标准偏差为1.54%~7.84%(n=7)。对六种土壤国家一级标准物质进行了测定,测定结果与推荐值相符,无显著性差异。该方法简便、准确,分析效率高,能够满足日常批量样品分析的要求。  相似文献   

13.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

14.
微波消解-紫外分光光度法测定水中总氮   总被引:5,自引:0,他引:5  
研究了用微波消解-紫外分光光度法测定水样中的总氮,结果表明,所提出的消解方法具有操作简单、省时、消解完全的特点,精密度和准确度均令人满意.方法的线性范吲为0.0242~9.60mg/L,水样加标回收率为101%~103%,相对标准偏差为0.13%~0.44%。  相似文献   

15.
采用连续流动分析法测定污水中氨氮、总磷的含量。比较了污水样品不同的稀释倍数对测定结果的影响。实验结果表明:氨氮和总磷的质量浓度在0.1~8 mg/L范围内线性良好,线性相关系数均为0.99997;测量结果的相对标准偏差分别为2.01%,0.84%(n=7);方法检出限分别为0.012,0.009 mg/L;质控样测量值均在标示值范围内;样品加标回收率为93.4%~101.1%。污水的洁净程度对测定结果影响较大。洁净度高的污水,直接测定与稀释后测定,测定值无显著性差异;而洁净度低的污水,直接测定与稀释后测定结果差异比较大。该法采用全谱直读CCD检测方式,灵敏度高,稳定性好,无光谱干扰,且支持氨氮和总磷同时测定,方便快捷,适合污水中氨氮和总磷的测定。  相似文献   

16.
马剑  袁东星  官斌  杨荣  葛老伟 《色谱》2007,25(2):245-247
建立了循环冷却水中羟基-1,1-亚乙基二磷酸(HEDP)的离子色谱检测方法。色谱柱为IonPac AS14A阴离子交换柱,流动相为80 mmol/L NaOH水溶液,流速1.0 mL/min,抑制型电导检测器检测。方法的线性范围为0.25~25 mg/L,平均回收率为102%,检出限为0.1 mg/L;对0.25 mg/L和0.5 mg/L的HEDP标准溶液分别进行13次平行测定,相对标准偏差(RSD)分别为4.7%和3.5%。该方法具有简单、快速、灵敏、抗干扰等优点,用于循环冷却水中HEDP的检测,结果令人满意。  相似文献   

17.
建立火焰原子吸收光谱法测定锌合金中镁含量。选用10 mL盐酸溶液(1+1)溶解样品,加入5 mL质量浓度为100 g/L的LaCl3溶液,以消除铝对镁的化学干扰,在选定的仪器工作条件下进行测定。结果表明,镁的质量浓度在0~1.238 mg/L范围内与与吸光度具有良好的线性关系,相关系数为0.999 4,线性方程为Y=1.086 4X+0.018 5,方法测定下限为0.010 mg/L。样品测定结果的相对标准偏差为1.61%~3.45%(n=6),加标回收率为91.3%~94.7%。该方法准确度高,精密度好,满足锌合金中镁含量的日常检测要求。  相似文献   

18.
We have examined transient isotachophoresis (ITP) conditions, e.g. the nature of the terminating ion, its concentration, and the injection procedure, to improve the limit of detection (LOD) for determination of nitrite and nitrate in seawater by capillary zone electrophoresis (CZE). Artificial seawater containing 3.0 mmol L(-1) cetyltrimethylammonium chloride (CTAC) was used as background electrolyte (BGE). After sample injection 600 mmol L(-1) acetate was separately injected into the capillary as the terminating ion for transient ITP. The LOD for nitrite and nitrate, obtained at a signal-to-noise ratio (S/N) of 3, were 15 and 7.0 microg L(-1) (as nitrogen), respectively. Relative standard deviations (RSD) of peak area for nitrite and nitrate were 7.3 and 0.8%, respectively, and the RSD of peak height were 5.7 and 1.2%, respectively, when the concentrations of nitrite and nitrate were 0.05 and 0.25 mg L(-1). The RSD of migration time for these ions was 0.2%. The proposed method was applied to the determination of nitrite and nitrate in seawater samples. The results for nitrite were nearly in agreement with those obtained by naphthylethylenediamine spectrophotometric analysis (SPA; correlation coefficient 0.9041).  相似文献   

19.
建立水杨酸钠紫外分光光度法测定烟草中总氮含量的方法。烟草样品经硫酸铜–硫酸钾–浓硫酸消化,用水杨酸钠–二氯异氰尿酸钠显色后用紫外分光光度计检测,并对波长、显色剂用量和反应时间等实验条件进行了优化。总氮的质量浓度在5~60 mg/L范围内与其吸光度呈良好的线性关系,线性相关系数为0.998 8,方法的检出限为0.14 mg/L。样品分析结果的相对标准偏差为3.22%(n=6),样品加标回收率为99.30%~101.62%。该方法具有较高的精密度和准确度,尤其适用于样品量少时对烟草中总氮的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号